Reference record for OID 1.3.6.1.4.1.11.2.14.11.4.5.3



parent
1.3.6.1.4.1.11.2.14.11.4.5 (hpicfGRpSwitchConfig)
node code
3
node name
hpicfGRpCurrentPrimarySwitch
dot oid
1.3.6.1.4.1.11.2.14.11.4.5.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(11) nm(2) icf(14) hpicfObjects(11) hpicfGenericRepeater(4) hpicfGRpSwitchConfig(5) hpicfGRpCurrentPrimarySwitch(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) IMPORTS(11) nm(2) icf(14) hpicfObjects(11) hpicfGenericRepeater(4) hpicfGRpSwitchConfig(5) hpicfGRpCurrentPrimarySwitch(3)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(11) nm(2) icf(14) hpicfObjects(11) hpicfGenericRepeater(4) hpicfGRpSwitchConfig(5) hpicfGRpCurrentPrimarySwitch(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) IMPORTS(11) nm(2) icf(14) hpicfObjects(11) hpicfGenericRepeater(4) hpicfGRpSwitchConfig(5) hpicfGRpCurrentPrimarySwitch(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(11) nm(2) icf(14) hpicfObjects(11) hpicfGenericRepeater(4) hpicfGRpSwitchConfig(5) hpicfGRpCurrentPrimarySwitch(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) IMPORTS(11) nm(2) icf(14) hpicfObjects(11) hpicfGenericRepeater(4) hpicfGRpSwitchConfig(5) hpicfGRpCurrentPrimarySwitch(3)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(11) nm(2) icf(14) hpicfObjects(11) hpicfGenericRepeater(4) hpicfGRpSwitchConfig(5) hpicfGRpCurrentPrimarySwitch(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) IMPORTS(11) nm(2) icf(14) hpicfObjects(11) hpicfGenericRepeater(4) hpicfGRpSwitchConfig(5) hpicfGRpCurrentPrimarySwitch(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/hp/nm/icf/hpicfObjects/hpicfGenericRepeater/hpicfGRpSwitchConfig/hpicfGRpCurrentPrimarySwitch
  • /iso/identified-organization/dod/internet/private/enterprise/IMPORTS/nm/icf/hpicfObjects/hpicfGenericRepeater/hpicfGRpSwitchConfig/hpicfGRpCurrentPrimarySwitch
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/hp/nm/icf/hpicfObjects/hpicfGenericRepeater/hpicfGRpSwitchConfig/hpicfGRpCurrentPrimarySwitch
  • /iso/org/dod/internet/private/enterprise/IMPORTS/nm/icf/hpicfObjects/hpicfGenericRepeater/hpicfGRpSwitchConfig/hpicfGRpCurrentPrimarySwitch
  • /iso/org/dod/internet/private/enterprises/hp/nm/icf/hpicfObjects/hpicfGenericRepeater/hpicfGRpSwitchConfig/hpicfGRpCurrentPrimarySwitch
  • /iso/org/dod/internet/private/enterprises/IMPORTS/nm/icf/hpicfObjects/hpicfGenericRepeater/hpicfGRpSwitchConfig/hpicfGRpCurrentPrimarySwitch
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/nm/icf/hpicfObjects/hpicfGenericRepeater/hpicfGRpSwitchConfig/hpicfGRpCurrentPrimarySwitch
  • /iso/iso-identified-organization/dod/internet/private/enterprises/IMPORTS/nm/icf/hpicfObjects/hpicfGenericRepeater/hpicfGRpSwitchConfig/hpicfGRpCurrentPrimarySwitch
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/11/2/14/11/4/5/3

    Description by mibdepot

    The hpicfGRpSwitchIndex of the switch that is
    currently the primary switch for this stack. The
    automatic port-to-segment distribution feature will
    make decisions based on which switch is the primary
    switch. A value of 0 indicates that there are no
    internal switches in the system, and no external
    switches have been configured.

    Parsed from file hpicfGenRptr.mib.txt
    Company: None
    Module: HP-ICF-GENERIC-RPTR

    Description by circitor

    The hpicfGRpSwitchIndex of the switch that is
    currently the primary switch for this stack. The
    automatic port-to-segment distribution feature will
    make decisions based on which switch is the primary
    switch. A value of 0 indicates that there are no
    internal switches in the system, and no external
    switches have been configured.

    Parsed from file HP-ICF-GENERIC-RPTR.mib
    Module: HP-ICF-GENERIC-RPTR

    Information by oid_info

    Vendor: Hewlett-Packard
    Module: HP-ICF-GENERIC-RPTR

    [Automatically extracted from oidview.com]

    Information by mibdepot

    hpicfGRpCurrentPrimarySwitch OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-only STATUS current DESCRIPTION "The hpicfGRpSwitchIndex of the switch that is currently the primary switch for this stack. The automatic port-to-segment distribution feature will make decisions based on which switch is the primary switch. A value of 0 indicates that there are no internal switches in the system, and no external switches have been configured." ::= { hpicfGRpSwitchConfig 3 }

    Information by circitor

    hpicfGRpCurrentPrimarySwitch OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-only STATUS current DESCRIPTION "The hpicfGRpSwitchIndex of the switch that is currently the primary switch for this stack. The automatic port-to-segment distribution feature will make decisions based on which switch is the primary switch. A value of 0 indicates that there are no internal switches in the system, and no external switches have been configured." ::= { hpicfGRpSwitchConfig 3 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.11)

    Peterson Tyler

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.11.2.14.11.4.5.3.0 hpicfGRpCurrentPrimarySwitch 0 0 None

    Brothers (3)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.11.2.14.11.4.5.1 hpicfGRpSwitchTable 1 6 hpicfGRpSwitchtable
    1.3.6.1.4.1.11.2.14.11.4.5.2 hpicfGRpSwitchLinkTable 1 5 A table of links to switch ports for both internal
    and external switches that are connected to repeater
    ports in this repeater sy…
    1.3.6.1.4.1.11.2.14.11.4.5.4 hpicfGRpDesiredPrimarySwitch 1 1 The hpicfGRpSwitchIndex of the switch that the
    network administrator wants to be the primary switch