This object specifies the number of bits
transmitted for each actual data bit. The value
twoForOne(1) means that two bits are transmitted
for each data bit, whereas fourForThree(2) means
that four bits are transmitted for each three
data bits. The extra bits transmitted are used
for error detection and correction at the
receiving station.
This object interacts with the objects
actFpModPhaseModulation and actFpModBitRate in that
the value fourForThree(2) cannot be SET if either the
PhaseModulation maintains a value of bpsk(2) or the
BitRate maintains a value of kbps32(1).
Thus, the set of allowable configurations are as
follows:
BitRate FecRatio PhaseModulation
kbps32(1) twoForOne(1) qpsk(1)
kbps32(1) twoForOne(1) bpsk(2)
kbps64(2) twoForOne(1) qpsk(1)
kbps64(2) twoForOne(1) bpsk(2)
kbps64(2) fourForThree(2) qpsk(1)
kbps128(3) twoForOne(1) qpsk(1)
kbps128(3) twoForOne(1) bpsk(2)
kbps128(3) fourForThree(2) qpsk(1)
kbps256(4) twoForOne(1) qpsk(1)
kbps256(4) fourForThree(2) qpsk(1)
Parsed from file act.mib.txt
Company: cai
Module: ACT-FP-MOD-DEMOD
Vendor: Computer Associates
Module: ACT-CONSTANTS (act.mib)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
actFpModFecRatio OBJECT-TYPE SYNTAX INTEGER { twoForOne(1), fourForThree(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the number of bits transmitted for each actual data bit. The value twoForOne(1) means that two bits are transmitted for each data bit, whereas fourForThree(2) means that four bits are transmitted for each three data bits. The extra bits transmitted are used for error detection and correction at the receiving station. This object interacts with the objects actFpModPhaseModulation and actFpModBitRate in that the value fourForThree(2) cannot be SET if either the PhaseModulation maintains a value of bpsk(2) or the BitRate maintains a value of kbps32(1). Thus, the set of allowable configurations are as follows: BitRate FecRatio PhaseModulation kbps32(1) twoForOne(1) qpsk(1) kbps32(1) twoForOne(1) bpsk(2) kbps64(2) twoForOne(1) qpsk(1) kbps64(2) twoForOne(1) bpsk(2) kbps64(2) fourForThree(2) qpsk(1) kbps128(3) twoForOne(1) qpsk(1) kbps128(3) twoForOne(1) bpsk(2) kbps128(3) fourForThree(2) qpsk(1) kbps256(4) twoForOne(1) qpsk(1) kbps256(4) fourForThree(2) qpsk(1)
continuousWave(3) sin(4)" ::= { actFpModulatorConfigEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1186.2.2.1.9.1.1.1.1.1 | actFpModulatorSlot | 0 | 0 | This object represents the unique identifier for a row in the Modulator Config table. The value of this object corresponds to th… |
1.3.6.1.4.1.1186.2.2.1.9.1.1.1.1.2 | actFpModIfFrequency | 0 | 0 | This object specifies the intermediate transmission frequency in kiloHertz (kHz). Supported values are in increments of 5kHz, ma… |
1.3.6.1.4.1.1186.2.2.1.9.1.1.1.1.3 | actFpModIfLevel | 0 | 0 | This object specifies the IF Transmission Level in -dB. The units are in increments of -0.5 dB, making the actual valid range bet… |
1.3.6.1.4.1.1186.2.2.1.9.1.1.1.1.4 | actFpModCarrierId | 0 | 0 | This object represents the physical port within the satellite system. It is used to uniquely identify this station. |
1.3.6.1.4.1.1186.2.2.1.9.1.1.1.1.5 | actFpModBitRate | 0 | 0 | This object specifies the Transmission Data Rate. This object interacts with the objects actFpModFecRatio and actFpModPhaseModula… |
1.3.6.1.4.1.1186.2.2.1.9.1.1.1.1.7 | actFpModPhaseModulation | 0 | 0 | This object specifies the type of phase modulation used when transmitting the signal. continuousWave(3) and sin(4) do not use any… |
1.3.6.1.4.1.1186.2.2.1.9.1.1.1.1.8 | actFpModV35Scrambler | 0 | 0 | This object specifies the type of V.35 Scrambler used prior to transmitting the signal. |
1.3.6.1.4.1.1186.2.2.1.9.1.1.1.1.9 | actFpModTransmitterState | 0 | 0 | This object controls the state of the transmitter. When this object maintains the value off(1), the transmission level is guarant… |
1.3.6.1.4.1.1186.2.2.1.9.1.1.1.1.10 | actFpModRfType | 0 | 0 | actFpModRftype |