The numeric blade ID.
Parsed from file BLADE-MIB.mib
Module: BLADE-MIB
Vendor: IBM
Module: BLADE-MIB
[Automatically extracted from oidview.com]
temperatureThresholdBladeId OBJECT-TYPE SYNTAX INTEGER { blade1(1), blade2(2), blade3(3), blade4(4), blade5(5), blade6(6), blade7(7), blade8(8), blade9(9), blade10(10), blade11(11), blade12(12), blade13(13), blade14(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The numeric blade ID." ::= { bladeTemperatureThresholdsEntry 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.1 | temperatureThresholdIndex | 0 | 0 | Blade temperature threshold table index. |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.3 | temperatureThresholdBladeExists | 0 | 0 | Indicates whether the server blade specified exists or not. |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.4 | temperatureThresholdBladePowerState | 0 | 0 | Indicates whether the server blade specified is powered on or not. |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.5 | temperatureThresholdBladeName | 0 | 0 | The name of the blade as a null terminated string. |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.6 | temperatureCPU1HardShutdown | 0 | 0 | The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the syst… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.7 | temperatureCPU1Warning | 0 | 0 | The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if en… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.8 | temperatureCPU1WarningReset | 0 | 0 | The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning ale… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.9 | temperatureCPU2HardShutdown | 0 | 0 | The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the syst… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.10 | temperatureCPU2Warning | 0 | 0 | The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if en… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.11 | temperatureCPU2WarningReset | 0 | 0 | The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning ale… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.12 | temperatureCPU3HardShutdown | 0 | 0 | The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the syst… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.13 | temperatureCPU3Warning | 0 | 0 | The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if en… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.14 | temperatureCPU3WarningReset | 0 | 0 | The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning ale… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.15 | temperatureCPU4HardShutdown | 0 | 0 | The blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the syst… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.16 | temperatureCPU4Warning | 0 | 0 | The blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if en… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.17 | temperatureCPU4WarningReset | 0 | 0 | The blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning ale… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.18 | temperatureDASD1HardShutdown | 0 | 0 | The blade DASD hard shutdown temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.19 | temperatureDASD1Warning | 0 | 0 | The blade DASD warning temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the si… |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.20 | temperatureDASD1WarningReset | 0 | 0 | The blade DASD warning reset temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.21 | bladeTempThresholdSensorCapability | 0 | 0 | Indicates whether the server blade is IPMI capable or not. |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.22 | temperatureSensor1HardShutdown | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.23 | temperatureSensor1Warning | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.24 | temperatureSensor1WarningReset | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.25 | temperatureSensor2HardShutdown | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.26 | temperatureSensor2Warning | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.27 | temperatureSensor2WarningReset | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.28 | temperatureSensor3HardShutdown | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.29 | temperatureSensor3Warning | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.30 | temperatureSensor3WarningReset | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.31 | temperatureSensor4HardShutdown | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.32 | temperatureSensor4Warning | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.33 | temperatureSensor4WarningReset | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.34 | temperatureSensor5HardShutdown | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.35 | temperatureSensor5Warning | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.36 | temperatureSensor5WarningReset | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.37 | temperatureSensor6HardShutdown | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.38 | temperatureSensor6Warning | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.39 | temperatureSensor6WarningReset | 0 | 0 | The blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' … |