Switch module power on or power off. If powering on a currently
powered off switch module, then the switch module will execute a POST.
The results of this POST will need to be retrieved using the 'Post Results'
command. Note: When powering off a currently powered on switch module,
a minimum of 1 second is needed to allow the switch to power off
before powering back on the switch.
Parsed from file BLADE-MIB.mib
Module: BLADE-MIB
Vendor: IBM
Module: BLADE-MIB
[Automatically extracted from oidview.com]
switchModulePowerOnOff OBJECT-TYPE SYNTAX INTEGER { poweroff(0), poweron(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Switch module power on or power off. If powering on a currently powered off switch module, then the switch module will execute a POST. The results of this POST will need to be retrieved using the 'Post Results' command. Note: When powering off a currently powered on switch module, a minimum of 1 second is needed to allow the switch to power off before powering back on the switch." ::= { smPowerRestartEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.1 | smPowerRestartIndex | 0 | 0 | Switch module power restart index. |
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.2 | smPowerRestartId | 0 | 0 | The switch module numeric identifier. |
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.3 | smSwitchExists | 0 | 0 | Indicates whether the switch module specified exists or not. |
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.4 | smSwitchType | 0 | 0 | smSwitchtype |
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.5 | smMACAddress | 0 | 0 | Switch module MAC address. |
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.6 | smIPAddress | 0 | 0 | The switch module current IP address. |
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.8 | smReset | 0 | 0 | For the case where the switch module is currently powered on, this command will effectively power off and then power on the swit… |
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.9 | smResetToDefault | 0 | 0 | For the case where the switch module is currently powered on, this command will effectively power off and then power on the swit… |
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.10 | smRestartAndRunStdDiag | 0 | 0 | To power cycle the selected module(s) and then run the standard diagnostic test package. NOTE: Value returned for the GET commna… |
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.11 | smRestartAndRunExtDiag | 0 | 0 | To power cycle the selected module(s) and then run the extended diagnostic test package. This option is not supported on all I/O… |
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12 | smRestartAndRunFullDiag | 0 | 0 | To power cycle the selected module(s) and then run the full diagnostic test package. The full diagnostic test package may take o… |