This is the Demodulator status, during the alarm acceptance . This field
is for internal use
internal debugging
Parsed from file CERAGON-MIB.mib
Module: CERAGON-MIB
Vendor: Giganet Ltd
Module: CERAGON-MIB
[Automatically extracted from oidview.com]
gnAgnLogFileDemodStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the Demodulator status, during the alarm acceptance . This field is for internal use internal debugging " ::= {gnAgnLogFileEntry 20 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2281.2.2.2.4.1.1 | gnAgnLogFileId | 0 | 0 | This value indicates the index of an alarm logfile entry. Entry 1 is the most recent logfile event |
1.3.6.1.4.1.2281.2.2.2.4.1.2 | gnAgnLogFileValid | 0 | 0 | This value indicates the validity of the indexed alarm logfile entry. a VALID log entry is (2) and an INVALID entry is (3). |
1.3.6.1.4.1.2281.2.2.2.4.1.3 | gnAgnLogFileDate | 0 | 0 | This field is the date the alarm occurred, formatted as YYYY-MM-DD. YYYY represents the year, MM the month and DD -the day. |
1.3.6.1.4.1.2281.2.2.2.4.1.4 | gnAgnLogFileTime | 0 | 0 | This field is the hour the alarm occurred - format HH:MM. HH - Hour, MM - minute |
1.3.6.1.4.1.2281.2.2.2.4.1.5 | gnAgnLogFileSeverity | 0 | 0 | This value indicates the severity of the alarm, 31 for CRITICAL, 15 for MAJOR, 7 for MINOR, 3 for WARNING and 1 for EVENT. |
1.3.6.1.4.1.2281.2.2.2.4.1.6 | gnAgnLogFileText | 0 | 0 | This field describes the alarm that occurred. Max length 40 characters. |
1.3.6.1.4.1.2281.2.2.2.4.1.7 | gnAgnLogFileDeviceCelsiusTemp | 0 | 0 | This is the temperature of the IDU in degrees Celsius, during the alarm acceptance. |
1.3.6.1.4.1.2281.2.2.2.4.1.8 | gnAgnLogFileDevicePowerSupply | 0 | 0 | This is the Power supply status of the IDU, during the alarm acceptance bit 1 on = 3.3V faulty bit 2 on = -5V faulty bit 3 on = 5V … |
1.3.6.1.4.1.2281.2.2.2.4.1.9 | gnAgnLogFileInternalCommunication | 0 | 0 | This is the internal communication status of the IDU, during the alarm acceptance bit 1 = 1: between main CPU and ODU CPU. bit 2 =… |
1.3.6.1.4.1.2281.2.2.2.4.1.10 | gnAgnLogFileDeviceFanStatus | 0 | 0 | This is the Fan status of the IDU, during the alarm acceptance bit 1 = Fan1 is faulty. bit 2 = Fan 2 is faulty. |
1.3.6.1.4.1.2281.2.2.2.4.1.11 | gnAgnLogFileDeviceODUStatus | 0 | 0 | This is the ODU status during the alarm acceptance bit 1 MSB bit 1 = Power Supply status bit 2 = Synthesizer lock status bit 3 = Tx… |
1.3.6.1.4.1.2281.2.2.2.4.1.12 | gnAgnLogFileDeviceIDUStatus | 0 | 0 | This is the IDU status during the alarm acceptance bit 1 MSB bit 1 = Power status - bit 2 = Cable open status - bit 3 = Cable sh… |
1.3.6.1.4.1.2281.2.2.2.4.1.13 | gnAgnLogFileOduCelsiusTemp | 0 | 0 | This is the temperature of the ODU in degrees Celsius, during the alarm acceptance. |
1.3.6.1.4.1.2281.2.2.2.4.1.14 | gnAgnLogFileOduReceiveLevel | 0 | 0 | This is the received signal level in DBM, during the alarm acceptance |
1.3.6.1.4.1.2281.2.2.2.4.1.15 | gnAgnLogFileOduSynthesizerVCOLock | 0 | 0 | This is the Synthesizer status, during the alarm acceptance bit 1 on = TX IF synthesizer fault bit 2 on = RX IF synthesizer fault… |
1.3.6.1.4.1.2281.2.2.2.4.1.16 | gnAgnLogFileOduPowerSupply | 0 | 0 | This is the ODU power supply status, during the alarm acceptance bit 1 on = +5V faulty bit 2 on = +8V faulty bit 3 on = +12V fault… |
1.3.6.1.4.1.2281.2.2.2.4.1.17 | gnAgnLogFileLineBERCur | 0 | 0 | This is the Line BER (Bit Error Rate), during the alarm acceptance. Included for future development, not currently supported. |
1.3.6.1.4.1.2281.2.2.2.4.1.18 | gnAgnLogFileRadioBERCur | 0 | 0 | This is the Radio BER (Bit Error Rate), during the alarm acceptance. Included for future development, not currently supported. |
1.3.6.1.4.1.2281.2.2.2.4.1.19 | gnAgnLogFileModStatus | 0 | 0 | This is the Modulator status, during the alarm acceptance ok(2), modulatorFault(3) |
1.3.6.1.4.1.2281.2.2.2.4.1.21 | gnAgnLogFileLastDemodDefectBlocks | 0 | 0 | This is the number of the Defected blocks (blocks that couldn't be corrected) by the FEC, during the alarm acceptance last second. |
1.3.6.1.4.1.2281.2.2.2.4.1.22 | gnAgnLogFileLastDemodBytesCorrected | 0 | 0 | This is the number of the bytes that were corrected by the FEC, during the alarm acceptance last second. |
1.3.6.1.4.1.2281.2.2.2.4.1.23 | gnAgnLogFileLastDemodBlocksCorrected | 0 | 0 | This is the number of the blocks that were corrected by the FEC , during the alarm acceptance last second. |
1.3.6.1.4.1.2281.2.2.2.4.1.24 | gnAgnLogFileUniqueId | 0 | 0 | Unique Id for each log from 1 to 2,147,483,647 ( = 0x7FFFFFFF). |
1.3.6.1.4.1.2281.2.2.2.4.1.25 | gnAgnLogFileSource | 0 | 0 | The soure drawer of the alarm. |
1.3.6.1.4.1.2281.2.2.2.4.1.26 | gnAgnLogFileTimeT | 0 | 0 | The time of the alarm represented by the number of seconds from 1.1.1970. |