Reference record for OID 1.3.6.1.4.1.23.2.2.2.2.1.3



parent
1.3.6.1.4.1.23.2.2.2.2.1 (rptrMonitorPortEntry, nrptrMonitorPortEntry)
node code
3
node name
rptrMonPortID
dot oid
1.3.6.1.4.1.23.2.2.2.2.1.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) novell(23) mibDoc(2) snmpDot3RptrMgt(2) rptrMonitorGroup(2) rptrMonitorPortTable(2) rptrMonitorPortEntry(1) rptrMonPortID(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) novell(23) mibDoc(2) snmpDot3RptrMgt(2) rptrMonitorGroup(2) rptrMonitorPortTable(2) nrptrMonitorPortEntry(1) rptrMonPortID(3)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) Excelan(23) gateways(2) nsnmpDot3RptrMgt(2) rptrMonitorGroup(2) nrptrMonitorPortTable(2) rptrMonitorPortEntry(1) rptrMonPortID(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) Excelan(23) gateways(2) nsnmpDot3RptrMgt(2) rptrMonitorGroup(2) nrptrMonitorPortTable(2) nrptrMonitorPortEntry(1) rptrMonPortID(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) novell(23) mibDoc(2) snmpDot3RptrMgt(2) rptrMonitorGroup(2) rptrMonitorPortTable(2) rptrMonitorPortEntry(1) rptrMonPortID(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) novell(23) mibDoc(2) snmpDot3RptrMgt(2) rptrMonitorGroup(2) rptrMonitorPortTable(2) nrptrMonitorPortEntry(1) rptrMonPortID(3)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) Excelan(23) gateways(2) nsnmpDot3RptrMgt(2) rptrMonitorGroup(2) nrptrMonitorPortTable(2) rptrMonitorPortEntry(1) rptrMonPortID(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) Excelan(23) gateways(2) nsnmpDot3RptrMgt(2) rptrMonitorGroup(2) nrptrMonitorPortTable(2) nrptrMonitorPortEntry(1) rptrMonPortID(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/novell/mibDoc/snmpDot3RptrMgt/rptrMonitorGroup/rptrMonitorPortTable/rptrMonitorPortEntry/rptrMonPortID
  • /iso/identified-organization/dod/internet/private/enterprise/novell/mibDoc/snmpDot3RptrMgt/rptrMonitorGroup/rptrMonitorPortTable/nrptrMonitorPortEntry/rptrMonPortID
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/Excelan/gateways/nsnmpDot3RptrMgt/rptrMonitorGroup/nrptrMonitorPortTable/rptrMonitorPortEntry/rptrMonPortID
  • /iso/org/dod/internet/private/enterprise/Excelan/gateways/nsnmpDot3RptrMgt/rptrMonitorGroup/nrptrMonitorPortTable/nrptrMonitorPortEntry/rptrMonPortID
  • /iso/org/dod/internet/private/enterprises/novell/mibDoc/snmpDot3RptrMgt/rptrMonitorGroup/rptrMonitorPortTable/rptrMonitorPortEntry/rptrMonPortID
  • /iso/org/dod/internet/private/enterprises/novell/mibDoc/snmpDot3RptrMgt/rptrMonitorGroup/rptrMonitorPortTable/nrptrMonitorPortEntry/rptrMonPortID
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/Excelan/gateways/nsnmpDot3RptrMgt/rptrMonitorGroup/nrptrMonitorPortTable/rptrMonitorPortEntry/rptrMonPortID
  • /iso/iso-identified-organization/dod/internet/private/enterprises/Excelan/gateways/nsnmpDot3RptrMgt/rptrMonitorGroup/nrptrMonitorPortTable/nrptrMonitorPortEntry/rptrMonPortID
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/23/2/2/2/2/1/3

    Description by oid_info

    rptrMonPortID OBJECT-TYPE
    SYNTAX INTEGER (1..1024)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
    "Port ID for identifying the port."
    REFERENCE
    "Reference [12] 19.2.6.2, portID."

    View at oid-info.com

    Description by mibdepot

    Port ID for identifying the port.

    Parsed from file Compaq-Mdb.mib.txt
    Company: compaq
    Module: NETWORTH-TriSegment-MIB

    Information by oid_info

    Automatically extracted from nwhub.mib

    Information by mibdepot

    rptrMonPortID OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "Port ID for identifying the port." REFERENCE "Reference [12] 19.2.6.2, portID." ::= { nrptrMonitorPortEntry 3 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.23)

    Bostock Steve

    Brothers (14)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.23.2.2.2.2.1.1 rptrMonPortRptrID 0 0 Repeater ID for identifying the port.
    1.3.6.1.4.1.23.2.2.2.2.1.2 rptrMonPortGroupID 0 0 Group ID for identifying the port.
    1.3.6.1.4.1.23.2.2.2.2.1.4 rptrMonPortReadableFrames 0 0 A representation of the total frames of valid
    frame length. This counter is incremented by one
    for each frame whose OctetCount is…
    1.3.6.1.4.1.23.2.2.2.2.1.5 rptrMonPortReadableOctets 0 0 Increment counter by OctetCount for each frame
    which which has been determined to be a readable
    frame.

    Note: The approximate mini…
    1.3.6.1.4.1.23.2.2.2.2.1.6 rptrMonPortFrameCheckSequenceErrs 0 0 Increment counter by one for each frame with
    FCSError and without FramingError and whose
    OctetCount is greater than or equal to
    mi…
    1.3.6.1.4.1.23.2.2.2.2.1.7 rptrMonPortAlignmentErrors 0 0 Increment counter by one for each frame with
    FCSError and FramingError and whose octetCount is
    greater than or equal to minFrameS…
    1.3.6.1.4.1.23.2.2.2.2.1.8 rptrMonPortFrameTooLongs 0 0 Increment counter by one for each frame whose
    OctetCount is greater than maxFrameSize (Ref:
    4.4.2.1 [11]).

    Note: The approximate …
    1.3.6.1.4.1.23.2.2.2.2.1.9 rptrMonPortShortEvents 0 0 Increment counter by one for each carrier event
    whose ActivityDuration is greater than
    ShortEventMinTime and less than ShortEvent…
    1.3.6.1.4.1.23.2.2.2.2.1.10 rptrMonPortRunts 0 0 Increment counter by one for each carrier event
    whose ActivityDuration is greater than
    ShortEventMaxTime and less than RuntMaxTi…
    1.3.6.1.4.1.23.2.2.2.2.1.11 rptrMonPortCollisions 0 0 Increment counter by one for each carrier event
    in which the CIPresent(X) variable has the value
    SQE (see 9.6.6.2 [11]).

    Note: …
    1.3.6.1.4.1.23.2.2.2.2.1.12 rptrMonPortLateCollisions 0 0 Increment counter by one for each carrier event
    in which the CIPresent(X) variable has the value
    SQE (see 9.6.6.2 [11]) at any ti…
    1.3.6.1.4.1.23.2.2.2.2.1.13 rptrMonPortDataRateMismatches 0 0 The dataRateMismatches object counts the number
    of times that a packet has been received by this
    port with the transmission frequ…
    1.3.6.1.4.1.23.2.2.2.2.1.14 rptrMonPortAutoPartitions 0 0 The autoPartitions object counts the number of
    times that the repeater has automatically
    partitioned this port. The conditions th…
    1.3.6.1.4.1.23.2.2.2.2.1.15 rptrMonPortVeryLongEvents 0 0 The veryLongEvents object counts the number of
    times a packet has been received by this port
    that was so long that the repeater w…