Status and quit of alarm relay 2.
(2) relay is switched because of an alarm
(3) relay is not switched, no alarm
(4) (set) will quit relay 2 in case of alarm
        
            
            Parsed from file CPQCMC.MIB.txt
            
            Company: None
            
            Module: CPQCMC-MIB
        
        
Status and quit of alarm relay 2.
(2) relay is switched because of an alarm
(3) relay is not switched, no alarm
(4) (set) will quit relay 2 in case of alarm
        
            
            Parsed from file CPQCMC-MIB.mib
            
            Module: CPQCMC-MIB
        
        
cpqCmcSetQuitRelay2 OBJECT-TYPE SYNTAX INTEGER { other (1), switched (2), notSwitched (3), quit (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Status and quit of alarm relay 2. (2) relay is switched because of an alarm (3) relay is not switched, no alarm (4) (set) will quit relay 2 in case of alarm" ::= { cpqCmcControl 12 }
Vendor: Compaq
Module: CPQCMC-MIB
[Automatically extracted from oidview.com]
cpqCmcSetQuitRelay2 OBJECT-TYPE SYNTAX INTEGER { other (1), switched (2), notSwitched (3), quit (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Status and quit of alarm relay 2. (2) relay is switched because of an alarm (3) relay is not switched, no alarm (4) (set) will quit relay 2 in case of alarm" ::= { cpqCmcControl 12 }
| OID | Name | Sub children | Sub Nodes Total | Description | 
|---|---|---|---|---|
| 1.3.6.1.4.1.232.153.2.2.5.12.0 | cpqCmcSetQuitRelay2 | 0 | 0 | None | 
| OID | Name | Sub children | Sub Nodes Total | Description | 
|---|---|---|---|---|
| 1.3.6.1.4.1.232.153.2.2.5.1 | cpqCmcStatusAccess | 1 | 1 | Status access, for future use | 
| 1.3.6.1.4.1.232.153.2.2.5.2 | cpqCmcSetLock1Lock | 1 | 1 | Set door locking device 1, see table With this command the management-station can set the conditions for the door locking device (… | 
| 1.3.6.1.4.1.232.153.2.2.5.3 | cpqCmcSetLock1Key | 1 | 1 | Enable or disable unlocking of the rack-door with external components like keypad or remote input. With this command the manageme… | 
| 1.3.6.1.4.1.232.153.2.2.5.4 | cpqCmcSetLock2Lock | 1 | 1 | Set door locking device 2, see table With this command the management-station can set the conditions for the door locking device (… | 
| 1.3.6.1.4.1.232.153.2.2.5.5 | cpqCmcSetLock2Key | 1 | 1 | Enable or disable unlocking of the rack-door with external components like keypad or remote input. With this command the manageme… | 
| 1.3.6.1.4.1.232.153.2.2.5.6 | cpqCmcSetMessage | 1 | 1 | Set message to CMC, for future use | 
| 1.3.6.1.4.1.232.153.2.2.5.7 | cpqCmcSetAlarm1 | 1 | 1 | Is used to set an alarm in the CMC from the management-station. With this command the management-station can i.e. switch on an al… | 
| 1.3.6.1.4.1.232.153.2.2.5.8 | cpqCmcSetAlarm2 | 1 | 1 | Is used to set an alarm in the CMC from the management-station. With this command the management-station can i.e. switch on an al… | 
| 1.3.6.1.4.1.232.153.2.2.5.9 | cpqCmcSetFan1 | 1 | 1 | Is used for run and stop control of fan1. (2) fan will run and stop according to temperature of sensor 1 and threshold of fan1 (3)… | 
| 1.3.6.1.4.1.232.153.2.2.5.10 | cpqCmcSetFan2 | 1 | 1 | Is used for run and stop control of fan2. (2) fan will run and stop according to temperature of sensor 2 and threshold of fan2 (3)… | 
| 1.3.6.1.4.1.232.153.2.2.5.11 | cpqCmcSetQuitRelay1 | 1 | 1 | Status and quit of alarm relay 1. (2) relay is switched because of an alarm (3) relay is not switched, no alarm (4) (set) will qui… |