Reference record for OID 1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.2



parent
1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1 (scesPhyEntry)
node code
2
node name
scesPhyCurrentLineType
dot oid
1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mariposaTech(2426) mariposaProducts(1) mariposaAtx50Atx150Objs(2) voiceInterfaces(6) sces(7) scesPhy(1) scesPhyPar(1) scesPhyTable(1) scesPhyEntry(1) scesPhyCurrentLineType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) mariposaTech(2426) mariposaProducts(1) mariposaAtx50Atx150Objs(2) voiceInterfaces(6) sces(7) scesPhy(1) scesPhyPar(1) scesPhyTable(1) scesPhyEntry(1) scesPhyCurrentLineType(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) mariposaTech(2426) mariposaProducts(1) mariposaAtx50Atx150Objs(2) voiceInterfaces(6) sces(7) scesPhy(1) scesPhyPar(1) scesPhyTable(1) scesPhyEntry(1) scesPhyCurrentLineType(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) mariposaTech(2426) mariposaProducts(1) mariposaAtx50Atx150Objs(2) voiceInterfaces(6) sces(7) scesPhy(1) scesPhyPar(1) scesPhyTable(1) scesPhyEntry(1) scesPhyCurrentLineType(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mariposaTech(2426) mariposaProducts(1) mariposaAtx50Atx150Objs(2) voiceInterfaces(6) sces(7) scesPhy(1) scesPhyPar(1) scesPhyTable(1) scesPhyEntry(1) scesPhyCurrentLineType(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) mariposaTech(2426) mariposaProducts(1) mariposaAtx50Atx150Objs(2) voiceInterfaces(6) sces(7) scesPhy(1) scesPhyPar(1) scesPhyTable(1) scesPhyEntry(1) scesPhyCurrentLineType(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/mariposaTech/mariposaProducts/mariposaAtx50Atx150Objs/voiceInterfaces/sces/scesPhy/scesPhyPar/scesPhyTable/scesPhyEntry/scesPhyCurrentLineType
  • /iso/identified-organization/dod/internet/private/enterprises/mariposaTech/mariposaProducts/mariposaAtx50Atx150Objs/voiceInterfaces/sces/scesPhy/scesPhyPar/scesPhyTable/scesPhyEntry/scesPhyCurrentLineType
  • /iso/org/dod/internet/private/enterprise/mariposaTech/mariposaProducts/mariposaAtx50Atx150Objs/voiceInterfaces/sces/scesPhy/scesPhyPar/scesPhyTable/scesPhyEntry/scesPhyCurrentLineType
  • /iso/org/dod/internet/private/enterprises/mariposaTech/mariposaProducts/mariposaAtx50Atx150Objs/voiceInterfaces/sces/scesPhy/scesPhyPar/scesPhyTable/scesPhyEntry/scesPhyCurrentLineType
  • /iso/iso-identified-organization/dod/internet/private/enterprise/mariposaTech/mariposaProducts/mariposaAtx50Atx150Objs/voiceInterfaces/sces/scesPhy/scesPhyPar/scesPhyTable/scesPhyEntry/scesPhyCurrentLineType
  • /iso/iso-identified-organization/dod/internet/private/enterprises/mariposaTech/mariposaProducts/mariposaAtx50Atx150Objs/voiceInterfaces/sces/scesPhy/scesPhyPar/scesPhyTable/scesPhyEntry/scesPhyCurrentLineType
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/2426/1/2/6/7/1/1/1/1/2

    Description by mibdepot

    This object indicates the type of the line
    implementing this circuit. It defines the link type
    that is currently active in the system. The link
    type should be changed through scesPhyStoredLineType
    object which changes the link type that is stored in
    the flash and it will become active (will become the
    current link type) only after rebooting the system.
    The type of circuit affects the number of bits per
    second that the circuit can reasonably carry, as well
    as the interpretation of the usage and error
    statistics. The values, in sequence, describe:

    TITLE: SPECIFICATION:
    t1 ANSI T1 Standard
    e1 ITU-T Recommendation G.704 (Table 4a)

    Parsed from file mariposa.mib.txt
    Company: marconi
    Module: MARIPOSA-MIB

    Information by oid_info

    Vendor: Marconi
    Module: MARIPOSA-MIB (mariposa.mib)
    Type: TABULAR
    Access: read-write
    Syntax: INTEGER

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    scesPhyCurrentLineType OBJECT-TYPE SYNTAX INTEGER { t1 (1), e1 (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the type of the line implementing this circuit. It defines the link type that is currently active in the system. The link type should be changed through scesPhyStoredLineType object which changes the link type that is stored in the flash and it will become active (will become the current link type) only after rebooting the system. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: t1 ANSI T1 Standard e1 ITU-T Recommendation G.704 (Table 4a)" ::= { scesPhyEntry 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.2426)

    Osanitsch John

    Brothers (20)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.1 scesPhyIfIndex 0 0 This value for this object is equal to the value
    of ifIndex from the Interfaces table of MIB II
    (RFC 1213).
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.3 scesPhyStoredLineType 0 0 This object indicates the type of the line
    implementing this circuit that is saved in the flash.
    When the value of this object …
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.4 scesPhyCurrentFraming 0 0 This object indicates the framing type that is
    used for this circuit. It defines the framing type
    that is currently active in the…
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.5 scesPhyStoredFraming 0 0 This object indicates the framing type that is
    used for this circuit. It defines the framing
    type.


    The values, in sequence, desc…
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.6 scesPhyCurrentLineCoding 0 0 This variable describes the variety of Zero Code
    Suppression that is currently used on this interface,
    which in turn affects a nu…
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.7 scesPhyStoredLineCoding 0 0 This variable describes the variety of Zero Code
    Suppression of this interface that is saved in the flash.
    When the value of this…
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.8 scesPhyLineLength 0 0 The length of the ds1 line in meters. This
    objects provides information for line build out
    circuitry if it exists and can use thi…
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.9 scesPhyTxClockSource 0 0 The source of Transmit Clock.
    'loopTiming' indicates that the recovered receive
    clock is used as the transmit clock.
    'SystemTiming…
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.10 scesPhyLoopbackMode 0 0 This variable represents the desired loopback
    configuration of the interface. Agents
    supporting read/write access should return
    b…
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.11 scesPhySignalingMode 0 0 This object specifies signaling mode for SCES link.
    This can have CCS mode, CAS mode, CES Basic mode or
    CES with CAS, CAS Without…
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.12 scesPhyAlarmReporting 0 0 This object identifies the Alarm Reporting
    of the sces voice.
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.13 scesPhyVoiceCompanding 0 0 This object specifies the channel the
    voice companding technique - either A-law or mode.
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.14 scesPhySystemClockSource 0 0 This object identifies the System Clock Source.
    It can be 1.Internal
    2.ATM
    3.CBR
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.15 scesPhySystemClockSourceStatus 0 0 This objects specifies whether the clock source defined by
    'systemClockSource' is refering to a valid resource or not.
    If the spe…
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.16 scesPhyLossOfSignalState 0 0 Near end Loss Of Signal. When cells are continuously
    lost the value is set to loss (2). When cells are no
    longer lost, the value …
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.17 scesPhyLossOfFrameState 0 0 Near end LOF (a.k.a., Red Alarm). For DS1 links, the
    Loss Of Frame failure is declared when an OOF or LOS
    defect has persisted fo…
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.18 scesPhyXmtFarEndLOFFState 0 0 Near End is sending the LOF indication.
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.19 scesPhyRcvFarEndLOFFState 0 0 The Far End LOF failure Alarm is also known as Yellow
    Alarm in the DS1 case, and Distant Alarm in the E1
    case.
    For D4 links, the F…
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.20 scesPhyAISFState 0 0 Far end sending Alarm Indication Signal(AIS) a.k.a Remote
    Alarm Indication (RAI).
    For D4 and ESF links, the 'all ones' condition …
    1.3.6.1.4.1.2426.1.2.6.7.1.1.1.1.21 scesPhyXmtAISFState 0 0 Near end sending Alarm Indication Signal(AIS).
    For D4 and ESF links, the 'all ones' condition is detected at
    a DS1 line interface…