Status door, open/closed/locked
Identification
{1 3 6 1 4 1 2606 1 2 17}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.2606.1.2.17.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
table OBJECT IDENTIFIER ::= { status 17 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Source file: Download Cmc32.mib.txt
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: unspecified.
Names: table
{
"smi_kind": "OBJECT IDENTIFIER",
"definition": [
"table",
"OBJECT",
"IDENTIFIER",
"::=",
"{",
"status",
"17",
"}"
]
}Module: CMC-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Source data warning: MIB copy distributed by Fujitsu in its ServerView package. The original vendor distribution and applicability to a particular device or firmware have not been independently confirmed; consult the named file and IANA enterprise registration.
· Download ServerView MIB copy — CMC32.MIB (saved edition 1)Historical records
statusDoor2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status door, open/closed/locked"
::= { status 17 }
statusDoor2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status door, open/closed/locked"
::= { status 17 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2606.1.2.17.0 | statusDoor2 | 0 | 0 | |
| 1.3.6.1.4.1.2606.1.2.17.1 | statusNumber | 0 | 0 | |
| 1.3.6.1.4.1.2606.1.2.17.2 | statusTable | 1 | 4 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2606.1.2.1 | statusTemperature1 | 1 | 1 | Status temperature 1, OK/ too low/ too high (see setpoints of temperature 1) |
| 1.3.6.1.4.1.2606.1.2.2 | statusTemperature2 | 1 | 1 | Status temperature 2, OK/ too low/ too high (see setpoints of temperature 2) |
| 1.3.6.1.4.1.2606.1.2.3 | statusFan1 | 1 | 1 | Status fan 1, Stop/ running/ fault |
| 1.3.6.1.4.1.2606.1.2.4 | statusFan2 | 1 | 1 | Status fan 2, Stop/ running/ fault |
| 1.3.6.1.4.1.2606.1.2.5 | statusHeating | 1 | 1 | Status heating, On/Off |
| 1.3.6.1.4.1.2606.1.2.6 | statusPowerSupply | 1 | 1 | Status power supply, OK/ too low/ too high (see setpoints of power supply) |
| 1.3.6.1.4.1.2606.1.2.7 | statusAnalogAux1 | 1 | 1 | Status aux analog input 1, OK/ too low/ too high |
| 1.3.6.1.4.1.2606.1.2.8 | statusAnalogAux2 | 1 | 1 | Status aux analog input 2, OK/ too low/ too high |
| 1.3.6.1.4.1.2606.1.2.9 | statusDoor1, statusDoor | 1 | 1 | Status door, open/closed/locked |
| 1.3.6.1.4.1.2606.1.2.10 | statusUps1 | 1 | 1 | Status UPS 1, OK/ fault |
| 1.3.6.1.4.1.2606.1.2.11 | statusUps2 | 1 | 1 | Status UPS 2, OK/ fault |
| 1.3.6.1.4.1.2606.1.2.12 | statusSmokeSensor | 1 | 1 | Status smoke-sensor, OK/ smoke |
| 1.3.6.1.4.1.2606.1.2.13 | statusVibrationSensor | 1 | 1 | Status vibration sensor, OK/ vibration |
| 1.3.6.1.4.1.2606.1.2.14 | statusMessage | 1 | 1 | Message from CMC |
| 1.3.6.1.4.1.2606.1.2.15 | valueOperatingTime | 1 | 1 | Operating time CMC-unit |
| 1.3.6.1.4.1.2606.1.2.16 | statusUnit | 1 | 1 | Unit of temperature-values, Celsius or Fahrenheit |
| 1.3.6.1.4.1.2606.1.2.18 | table | 2 | 7 |