Reference record for OID 1.3.6.1.4.1.2947.1.8.4.27


parent
1.3.6.1.4.1.2947.1.8.4 (upsWellKnownAlarms)
node code
27
node name
upsAlarmCheckMOV
dot oid
1.3.6.1.4.1.2947.1.8.4.27
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) bestPower(2947) bestLink(1) upsAlarm(8) upsWellKnownAlarms(4) upsAlarmCheckMOV(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) bestPower(2947) bestLink(1) upsAlarm(8) upsWellKnownAlarms(4) upsAlarmCheckMOV(27)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) bestPower(2947) bestLink(1) upsAlarm(8) upsWellKnownAlarms(4) upsAlarmCheckMOV(27)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) bestPower(2947) bestLink(1) upsAlarm(8) upsWellKnownAlarms(4) upsAlarmCheckMOV(27)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) bestPower(2947) bestLink(1) upsAlarm(8) upsWellKnownAlarms(4) upsAlarmCheckMOV(27)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) bestPower(2947) bestLink(1) upsAlarm(8) upsWellKnownAlarms(4) upsAlarmCheckMOV(27)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/bestPower/bestLink/upsAlarm/upsWellKnownAlarms/upsAlarmCheckMOV
  • /iso/identified-organization/dod/internet/private/enterprises/bestPower/bestLink/upsAlarm/upsWellKnownAlarms/upsAlarmCheckMOV
  • /iso/org/dod/internet/private/enterprise/bestPower/bestLink/upsAlarm/upsWellKnownAlarms/upsAlarmCheckMOV
  • /iso/org/dod/internet/private/enterprises/bestPower/bestLink/upsAlarm/upsWellKnownAlarms/upsAlarmCheckMOV
  • /iso/iso-identified-organization/dod/internet/private/enterprise/bestPower/bestLink/upsAlarm/upsWellKnownAlarms/upsAlarmCheckMOV
  • /iso/iso-identified-organization/dod/internet/private/enterprises/bestPower/bestLink/upsAlarm/upsWellKnownAlarms/upsAlarmCheckMOV
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/2947/1/8/4/27

    Description by mibdepot

    One or more MOVs have failed due to a voltage surge.

    Parsed from file bestpwr.mib.txt
    Company: None
    Module: BESTPOWER-MIB

    Description by circitor

    One or more MOVs have failed due to a voltage surge.

    Parsed from file BESTPOWER-MIB.mib
    Module: BESTPOWER-MIB

    Information by oid_info

    Vendor: Best Power - A Division of General Signal Power Systems
    Module: BESTPOWER-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    upsAlarmCheckMOV OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "One or more MOVs have failed due to a voltage surge." ::= { upsWellKnownAlarms 27 }

    Information by circitor

    upsAlarmCheckMOV OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "One or more MOVs have failed due to a voltage surge." ::= { upsWellKnownAlarms 27 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.2947)

    Young Brian

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2947.1.8.4.27.0 upsAlarmCheckMOV 0 0 None

    Brothers (35)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.2947.1.8.4.1 upsAlarmOnBattery 1 1 The UPS is drawing power from the batteries.
    1.3.6.1.4.1.2947.1.8.4.2 upsAlarmLowRuntime 1 1 The remaining battery runtime is less than or equal
    to the upsConfigLowRuntimeSetpoint.
    1.3.6.1.4.1.2947.1.8.4.3 upsAlarmNearLowBattery 1 1 The battery voltage on the UPS has reached a value where the inverter will
    not be able to function very much longer.
    1.3.6.1.4.1.2947.1.8.4.4 upsAlarmLowBattery 1 1 The battery voltage on the UPS has reached a value where the inverter
    has stopped providing output power to the connected load e…
    1.3.6.1.4.1.2947.1.8.4.5 upsAlarmHighBattery 1 1 The battery charger voltage on the UPS has reached a value that
    is too high for safe battery maintenance.
    1.3.6.1.4.1.2947.1.8.4.6 upsAlarmCheckBattery 1 1 The periodic battery test has failed. A manual test of the batteries
    needs to be performed to determine which battery\batteries…
    1.3.6.1.4.1.2947.1.8.4.7 upsAlarmReplaceBattery 1 1 One or more batteries have been determined to require
    replacement. Compatibility: Fortress II
    1.3.6.1.4.1.2947.1.8.4.8 upsAlarmCheckInverter 1 1 The inverter has failed the automatic system test.
    1.3.6.1.4.1.2947.1.8.4.9 upsAlarmBatteriesDisconnected 1 1 The UPS has detected that the DC voltage needed to start up is too
    low or missing.
    1.3.6.1.4.1.2947.1.8.4.10 upsAlarmOutputOverload 1 1 The output load exceeds the UPS output capacity.
    1.3.6.1.4.1.2947.1.8.4.11 upsAlarmLowAcOut 1 1 The output load has exceeded the UPS output capacity, and the UPS has shut down.
    1.3.6.1.4.1.2947.1.8.4.12 upsAlarmCircuitBreakerWarning 1 1 To much load equipment has been connected to the UPS and has has caused excess
    current draw from the output.
    1.3.6.1.4.1.2947.1.8.4.13 upsAlarmCircuitBreakerShdn 1 1 The UPS has shut down due to an extended excess of current draw
    from the output.
    1.3.6.1.4.1.2947.1.8.4.14 upsAlarmBypassOn 1 1 The Bypass is presently engaged on the UPS.
    1.3.6.1.4.1.2947.1.8.4.15 upsAlarmAutoBypass 1 1 The UPS has gone into the Auto Bypass mode to redirect power around
    the UPS circuitry.
    1.3.6.1.4.1.2947.1.8.4.16 upsAlarmSiteWiringFault 1 1 The UPS has found a problem in your wall outlet.
    1.3.6.1.4.1.2947.1.8.4.17 upsAlarmCheckFan 1 1 The fan on the UPS has stopped
    1.3.6.1.4.1.2947.1.8.4.18 upsAlarmHighAmbTemp 1 1 The internal temperature inside the UPS is too hot.
    1.3.6.1.4.1.2947.1.8.4.19 upsAlarmHighHSTemp 1 1 The Inverter heatsink assembly inside the UPS is to hot .
    1.3.6.1.4.1.2947.1.8.4.20 upsAlarmHighXFMRTemp 1 1 The temperature of the main transformer inside the UPS is too hot .
    1.3.6.1.4.1.2947.1.8.4.21 upsAlarmHighPFMTemp 1 1 The temperature of the PFM module inside the UPS is too hot .
    1.3.6.1.4.1.2947.1.8.4.22 upsAlarmProbeMissing 1 1 One or all of the sense probes has been disconnected on the UPS.
    1.3.6.1.4.1.2947.1.8.4.23 upsAlarmCheckPowerSupply 1 1 The internal DC supply voltages are attenuated or missing.
    1.3.6.1.4.1.2947.1.8.4.24 upsAlarmTapRegulator 1 1 The UPS detected a possible failure in the tap changer (open or
    welded relay, etc.)
    1.3.6.1.4.1.2947.1.8.4.25 upsAlarmRelayFailure 1 1 There is a hardware problem inside the UPS.
    1.3.6.1.4.1.2947.1.8.4.26 upsAlarmCheckFuse 1 1 The failure of one or more fuses has been detected.
    1.3.6.1.4.1.2947.1.8.4.28 upsAlarmMemoryError 1 1 The UPS has lost the programmed settings in the memory of the logic
    board.
    1.3.6.1.4.1.2947.1.8.4.29 upsAlarmCallService 1 1 A hardware malfunction has occurred inside the UPS. Please consult a
    factory authorized service representative for assistance.
    1.3.6.1.4.1.2947.1.8.4.30 upsAlarmupsFailed 1 1 A general fault in the UPS has been detected.
    1.3.6.1.4.1.2947.1.8.4.31 upsAlarmUserTest 1 1 A user test of the alarm beeper is in progress.
    1.3.6.1.4.1.2947.1.8.4.32 upsAlarmTestInProgress 1 1 A test is in progress.
    1.3.6.1.4.1.2947.1.8.4.33 upsAlarmDiagnosticTestFailed 1 1 The result of the last diagnostic test indicates a failure.
    1.3.6.1.4.1.2947.1.8.4.34 upsAlarmEPO 1 1 The Emergency Power OFF feature has been activiated at the RS-232
    port on the UPS.
    1.3.6.1.4.1.2947.1.8.4.35 upsAlarmUpsOff 1 1 The output of the UPS is in the off state.
    1.3.6.1.4.1.2947.1.8.4.36 upsAlarmCommunicationsLost 1 1 A problem has been encountered in the
    communications between the agent and the UPS.