The threshold for degraded minutes on the interface.
A trap is sent to the manager when this set threshold
is exceeded. Degraded minutes are determined by collecting
all of the available seconds, after removing any severely
errored seconds. The resulting seconds is grouped into
60 second intervals and if the cumulative errors during
the seconds present in the group exceeds 1E-6.
Parsed from file lucent_pm.mib.txt
Company: None
Module: LIVINGSTON-PM4-MIB
The threshold for degraded minutes on the interface.
A trap is sent to the manager when this set threshold
is exceeded. Degraded minutes are determined by collecting
all of the available seconds, after removing any severely
errored seconds. The resulting seconds is grouped into
60 second intervals and if the cumulative errors during
the seconds present in the group exceeds 1E-6.
Parsed from file LIVINGSTON-PM4-MIB.mib
Module: LIVINGSTON-PM4-MIB
Vendor: Livingston Enterprises, Inc.
Module: LIVINGSTON-PM4-MIB
[Automatically extracted from oidview.com]
lucentPM4FMT1E1ThreshDMs OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for degraded minutes on the interface. A trap is sent to the manager when this set threshold is exceeded. Degraded minutes are determined by collecting all of the available seconds, after removing any severely errored seconds. The resulting seconds is grouped into 60 second intervals and if the cumulative errors during the seconds present in the group exceeds 1E-6." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 11 }
lucentPM4FMT1E1ThreshDMs OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for degraded minutes on the interface. A trap is sent to the manager when this set threshold is exceeded. Degraded minutes are determined by collecting all of the available seconds, after removing any severely errored seconds. The resulting seconds is grouped into 60 second intervals and if the cumulative errors during the seconds present in the group exceeds 1E-6." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 11 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.1 | lucentPM4FMT1E1ThreshBoardIndex | 0 | 0 | Board ID for which the Trap threshold configuration must apply. It includes boards 1 - 10 and other devices such as power supplie… |
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.2 | lucentPM4FMT1E1ThreshUnitType | 0 | 0 | Unit type for which the Trap threshold configuration must be applied. |
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.3 | lucentPM4FMT1E1ThreshESs | 0 | 0 | The threshold for errored seconds on the interface. A trap is issued when this set limit is exceeded. When this threshold exceeds… |
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.4 | lucentPM4FMT1E1ThreshSESs | 0 | 0 | The threshold for severely errored seconds on the interface. A trap is issued when this limit is exceeded. A severely errored sec… |
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.5 | lucentPM4FMT1E1ThreshSEFSs | 0 | 0 | The threshold for severely errored framing seconds. A trap is issued when this threshold is exceeded. A severely errored framing … |
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.6 | lucentPM4FMT1E1ThreshUASs | 0 | 0 | The threshold for unavailable seconds. A trap is issued when this set threshold is exceeded. Unavailable seconds are calculated b… |
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.7 | lucentPM4FMT1E1ThreshCSSs | 0 | 0 | The threshold for controlled slip seconds on the interface. A trap is issued when this set threshold is exceeded. A controlled sl… |
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.8 | lucentPM4FMT1E1ThreshPCVs | 0 | 0 | The threshold for path code violations on the interface. A trap is issued when this set threshold is exceeded. PCV is a frame syn… |
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.9 | lucentPM4FMT1E1ThreshLESs | 0 | 0 | The threshold for line errored seconds on the interface. A trap is sent to the manager when this set threshold is exceeded. A lin… |
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.10 | lucentPM4FMT1E1ThreshBESs | 0 | 0 | The threshold for bursty errored seconds on the interface. A trap is sent to the manager when this set threshold is exceeded. A b… |
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.12 | lucentPM4FMT1E1ThreshRepTimer | 0 | 0 | If the trap is to be repeated, this object specifies the time in seconds. When this object value is set to 0, it indicates the tr… |
1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.13 | lucentPM4FMT1E1ThreshTrapAck | 0 | 0 | lucentPM4FMT1E1ThreshtrapAck |