The requested operating frequency for the blower.
Measured in tenths of hertz.
A value of -2147483648 indicates that this OID does
not apply to this device due to its configuration.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The requested operating frequency for the blower.
Measured in tenths of hertz.
A value of -2147483648 indicates that this OID does
not apply to this device due to its configuration.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
airFMModBlwr2CmdFreq OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The requested operating frequency for the blower. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration." ::= { airFMModBlwr2Entry 3 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
airFMModBlwr2CmdFreq OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The requested operating frequency for the blower. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration." ::= { airFMModBlwr2Entry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.1 | airFMModBlwr2ModuleIndex | 0 | 0 | The index of the module. |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.2 | airFMModBlwr2CtrlType | 0 | 0 | The type of blower controller. A value of notApplicable indicates that this OID does not apply to this device due to its configur… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.4 | airFMModBlwr2ActFreq | 0 | 0 | The frequency at which the blower controller is operating. Measured in tenths of hertz. A value of -2147483648 indicates that th… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.5 | airFMModBlwr2Poles | 0 | 0 | The number of poles of the blower motor that the blower controller is controlling. A value of -2147483648 indicates that this OID… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.6 | airFMModBlwr2RatedHorsePower | 0 | 0 | The power rating of the blower motor. Measured in hundredths of horsepower. A value of -2147483648 indicates that this OID does n… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.7 | airFMModBlwr2RatedCurrent | 0 | 0 | The current rating of the blower motor. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not a… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.8 | airFMModBlwr2ActTorq | 0 | 0 | The actual torque of the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.9 | airFMModBlwr2Current | 0 | 0 | The percent of rated current drawn by the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.10 | airFMModBlwr2Vlt | 0 | 0 | The voltage supplied to the blower motor. Measured in tenths of volts RMS. A value of -2147483648 indicates that this OID does no… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.11 | airFMModBlwr2DCLinkVlt | 0 | 0 | The voltage of the blower controller's DC bus. Measured in volts DC. A value of -2147483648 indicates that this OID does not apply… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.12 | airFMModBlwr2AccTime | 0 | 0 | The time to accelerate the blower to the specified frequency. Measured in tenths of seconds. A value of -2147483648 indicates th… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.13 | airFMModBlwr2DecTime | 0 | 0 | The time to decelerate the blower frequency to zero. Measured in tenths of seconds. A value of -2147483648 indicates that this OI… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.14 | airFMModBlwr2CapLife | 0 | 0 | The remaining life of the main circuit capacitor. Measured in tenths of percent. A value of -2147483648 indicates that this OID d… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.15 | airFMModBlwr2CtrlCoolFanLife | 0 | 0 | The total operation time of the blower controller cooling fan. Measured in hours. A value of -2147483648 indicates that this OID… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.16 | airFMModBlwr2ElOvMode | 0 | 0 | Enables or disables the electronic overload relay. A value of notApplicable indicates that this OID does not apply to this device… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.17 | airFMModBlwr2ElOvSetting | 0 | 0 | The electronic overload relay is activated when the current exceeds this threshold. Measured in hundredths of amps. A value of -2… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.18 | airFMModBlwr2ElOvTimeConst | 0 | 0 | The delay between the current exceeding the overload threshold and the activation of the electronic overload relay. Measured in … |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.19 | airFMModBlwr2FanPower | 0 | 0 | The actual power of the blower motor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not appl… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.20 | airFMModBlwr2HeatsinkTempC | 0 | 0 | The temperature of the heatsink on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that thi… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.21 | airFMModBlwr2HeatsinkTempF | 0 | 0 | The temperature of the heatsink on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that … |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.22 | airFMModBlwr2ChokeTempC | 0 | 0 | The temperature of the choke on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this O… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.23 | airFMModBlwr2ChokeTempF | 0 | 0 | The temperature of the choke on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that thi… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.24 | airFMModBlwr2InverterTempC | 0 | 0 | The temperature of the inverter on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that thi… |
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.25 | airFMModBlwr2InverterTempF | 0 | 0 | The temperature of the inverter on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that … |