Enable or disable low total output current alarm generation.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
Enable or disable low total output current alarm generation.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
isxModularDistSysCurrentAlarmLowEnable OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable low total output current alarm generation." ::= { isxModularDistSysCurrent 8 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
isxModularDistSysCurrentAlarmLowEnable OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable low total output current alarm generation." ::= { isxModularDistSysCurrent 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.22.4.2.8.0 | isxModularDistSysCurrentAlarmLowEnable | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.22.4.2.1 | isxModularDistSysCurrentRating | 1 | 1 | The 100 percent current rating of the distribution panel. |
1.3.6.1.4.1.318.1.1.22.4.2.2 | isxModularDistSysCurrentMonitoring | 1 | 1 | Indicates whether or not total output current measurements and alarm generation are present. |
1.3.6.1.4.1.318.1.1.22.4.2.3 | isxModularDistSysCurrentThresholdMin | 1 | 1 | When total system current in any phase drops below this value a critical alarm will exist. Specified as a percent of the panel r… |
1.3.6.1.4.1.318.1.1.22.4.2.4 | isxModularDistSysCurrentThresholdLow | 1 | 1 | When total system current in any phase drops below this value a warning alarm will exist. Specified as a percent of the panel ra… |
1.3.6.1.4.1.318.1.1.22.4.2.5 | isxModularDistSysCurrentThresholdHigh | 1 | 1 | When total system current in any phase exceeds this value a warning alarm will exist. Specified as a percent of the panel rating… |
1.3.6.1.4.1.318.1.1.22.4.2.6 | isxModularDistSysCurrentThresholdMax | 1 | 1 | When total system current in any phase exceeds this value a critical alarm will exist. Specified as a percent of the panel ratin… |
1.3.6.1.4.1.318.1.1.22.4.2.7 | isxModularDistSysCurrentAlarmMinEnable | 1 | 1 | Enable or disable minimum total output current alarm generation. |
1.3.6.1.4.1.318.1.1.22.4.2.9 | isxModularDistSysCurrentAlarmHighEnable | 1 | 1 | Enable or disable high total output current alarm generation. |
1.3.6.1.4.1.318.1.1.22.4.2.10 | isxModularDistSysCurrentAlarmMaxEnable | 1 | 1 | Enable or disable maximum total output current alarm generation. |
1.3.6.1.4.1.318.1.1.22.4.2.11 | isxModularDistSysCurrentTable | 1 | 5 | Allows for getting the total system phase current information. |