The configuration information for each Super ELAN Bridge instance
Parsed from file armlanex.txt
Company: marconi
Module: ARM-LAN-EMULATION-EXTENSION-MIB
Vendor: Marconi
Module: ARM-LAN-EMULATION-EXTENSION-MIB (armlanex.mib)
Type: ENTRY
Access: not-accessible
Syntax: ArmSEBridgeConfigEntry
Automatically extracted from www.mibdepot.com
armSEBridgeConfigEntry OBJECT-TYPE SYNTAX ArmSEBridgeConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The configuration information for each Super ELAN Bridge instance" INDEX { armSEBridgeId } ::= { armSEBridgeConfigTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.1 | armSEAtmIfNumber | 0 | 0 | The ATM interface number the Super ELAN (SE) bridging function is associated with. This number is used to determine the NETWORK … |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.2 | armSEEnabled | 0 | 0 | When enabled(1) the SE Bridge (SEB) will bridge frames to the ports defined in its bridging domain. When disabled(2) the SEB wi… |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.3 | armSEName | 0 | 0 | This is a user provided name to associate with the SEB. The SEB name is independent of the ELANs names of the constituent ELANs o… |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.4 | armSEFrameSize | 0 | 0 | Indicates the maximum SuperElan frame size. All ELANs in a single SEB must be set to the same maximum frame size. Valid Values 15… |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.5 | armSEMacCacheAge | 0 | 0 | The number of seconds a learned MAC address remains in the data frame forwarding cache without revalidation. |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.6 | armSERDCacheAge | 0 | 0 | The number of seconds a learned route descriptor remains in the data frame forwarding cache without revalidation. |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.7 | armSEPriority | 0 | 0 | The SuperElan Bridge spanning tree priority. A lower value will increase the likelihood of a SuperElan bridge becoming the root. … |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.8 | armSEMaxAge | 0 | 0 | The age at which the current Spanning Tree configuration is deemed too old. A value to small may cause the spanning tree to unnec… |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.9 | armSEBridgeHelloTime | 0 | 0 | The interval of time in seconds between the generation of Spanning Tree configuration messages generate by the root. Lower values… |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.10 | armSEBridgeForwardDelay | 0 | 0 | The delay in seconds that the SEB waits before transitioning to the next port state. The forward delay should be large enough to … |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.11 | armSEBridgeAddress | 0 | 0 | The Bridge MAC Address identifies the SuperELAN for the purposes of maintaining the SEB Spanning tree. If no value is configured… |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.12 | armSEType | 0 | 0 | This object indicates the type of SEB. sebEN(1) specifies a type of Ethernet, sebTR(2) specific's a type of Token Ring. |
1.3.6.1.4.1.326.2.8.2.6.118.4.5.118.4.1.2.1.13 | armSEConfigRowStatus | 0 | 0 | This object is used to create or delete entries (rows) in the SuperElan Bridge Configuration Table. |