The initial timeout value, in seconds, before the SMT
proxy attempts to backoff and retry. Since the SMT proxy
will attempt three retries before determining that the
proxied station is not answering, with the timeout
doubling for each retry, the total time for a request to
time out is equal to seven times the base timeout value.
Parsed from file linkb.mib.txt
Company: None
Module: LB3GH-1-0-7
The initial timeout value, in seconds, before the SMT
proxy attempts to backoff and retry. Since the SMT proxy
will attempt three retries before determining that the
proxied station is not answering, with the timeout
doubling for each retry, the total time for a request to
time out is equal to seven times the base timeout value.
Parsed from file LB3GH-1-0-7.mib
Module: LB3GH-1-0-7
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
lbSystemSmtProxyTimeoutBase OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "The initial timeout value, in seconds, before the SMT proxy attempts to backoff and retry. Since the SMT proxy will attempt three retries before determining that the proxied station is not answering, with the timeout doubling for each retry, the total time for a request to time out is equal to seven times the base timeout value." ::= { lbSystem 26 }
lbSystemSmtProxyTimeoutBase OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "The initial timeout value, in seconds, before the SMT proxy attempts to backoff and retry. Since the SMT proxy will attempt three retries before determining that the proxied station is not answering, with the timeout doubling for each retry, the total time for a request to time out is equal to seven times the base timeout value." ::= { lbSystem 26 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.43.7.1.11.26.0 | lbSystemSmtProxyTimeoutBase | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.43.7.1.11.1 | lbSystemId | 1 | 1 | The unique identifier assigned to this system during manufacturing. |
1.3.6.1.4.1.43.7.1.11.2 | lbSystemType | 1 | 1 | The type of the LinkBuilder system. |
1.3.6.1.4.1.43.7.1.11.3 | lbSystemName | 1 | 1 | The text string describing this system. |
1.3.6.1.4.1.43.7.1.11.4 | lbSystemManufacturer | 1 | 1 | The text string describing the manufacturer of this system. |
1.3.6.1.4.1.43.7.1.11.5 | lbSystemBackplaneRevision | 1 | 1 | The revision level of the system backplane. Bits 6 and 7 indicate the artwork revision. Bits 0 through 5 indicate the rework leve… |
1.3.6.1.4.1.43.7.1.11.6 | lbSystemSlotCount | 1 | 1 | The number of slots in the system. |
1.3.6.1.4.1.43.7.1.11.7 | lbSystemMemorySize | 1 | 1 | The amount of memory (RAM), in bytes, present on the system processor board. |
1.3.6.1.4.1.43.7.1.11.8 | lbSystemFlashMemorySize | 1 | 1 | The amount of flash memory, in bytes, present on the system processor board. |
1.3.6.1.4.1.43.7.1.11.9 | lbSystemNvMemorySize | 1 | 1 | The amount of non-volatile memory, in bytes, present on the system processor board. |
1.3.6.1.4.1.43.7.1.11.10 | lbSystemSoftwareRevision | 1 | 1 | The revision number of the LinkBuilder system software. Each byte indicates the following: byte 0: major release number. byte 1: m… |
1.3.6.1.4.1.43.7.1.11.11 | lbSystemBuildTime | 1 | 1 | The build time of the system software. |
1.3.6.1.4.1.43.7.1.11.12 | lbSystemControlPanelHardwareRevision | 1 | 1 | An 8-bit value specifying the revision level of the control panel hardware. |
1.3.6.1.4.1.43.7.1.11.13 | lbSystemControlPanelSoftwareRevision | 1 | 1 | An 8-bit value specifying the revision level of the control panel software. |
1.3.6.1.4.1.43.7.1.11.14 | lbSystemControlPanelLines | 1 | 1 | The number of lines in the control panel display. |
1.3.6.1.4.1.43.7.1.11.15 | lbSystemControlPanelColumns | 1 | 1 | The number of columns in the control panel display. |
1.3.6.1.4.1.43.7.1.11.16 | lbSystemControlPanelText | 1 | 1 | The currently displayed text in the control panel display. |
1.3.6.1.4.1.43.7.1.11.17 | lbSystemFddiMacCount | 1 | 1 | The number of FDDI MAC's present in the system. |
1.3.6.1.4.1.43.7.1.11.18 | lbSystemFddiPortCount | 1 | 1 | The number of FDDI ports present in the system. |
1.3.6.1.4.1.43.7.1.11.19 | lbSystemEthernetPortCount | 1 | 1 | The number of ethernet ports present in the system. |
1.3.6.1.4.1.43.7.1.11.20 | lbSystemExpressFunctionCount | 1 | 1 | The number of Ethernet Express functions present in the system. Curently this value is equal to the number of Express boards pres… |
1.3.6.1.4.1.43.7.1.11.21 | lbSystemExpressFddiPortCount | 1 | 1 | The number of Ethernet Express FDDI ports present in the system. |
1.3.6.1.4.1.43.7.1.11.22 | lbSystemExpressEthernetPortCount | 1 | 1 | The number of Ethernet Express ethernet ports present in the system. |
1.3.6.1.4.1.43.7.1.11.23 | lbSystemPowerSupplyCount | 1 | 1 | The number of power supply units present in the system. |
1.3.6.1.4.1.43.7.1.11.24 | lbSystemAction | 1 | 1 | This object, when read, always returns the value other (1). The behavior of setting this object to each of the acceptable values … |
1.3.6.1.4.1.43.7.1.11.25 | lbSystemBridgeFunctionCount | 1 | 1 | The number of bridge functions present in the system. Curently this value is equal to the sum of the number of Express and Switch… |
1.3.6.1.4.1.43.7.1.11.27 | lbSystemSmtProxyEvents | 1 | 1 | This object determines if the SMT proxy will generate traps for SMT events occuring at other stations. If enabled, the SMT proxy… |