Reference record for OID 1.3.6.1.4.1.476.1.42.3.2.1.85



parent
1.3.6.1.4.1.476.1.42.3.2.1 (lgpConditionsWellKnown)
node code
85
node name
lgpConditionEmergencyTransferToInverter
dot oid
1.3.6.1.4.1.476.1.42.3.2.1.85
type
OBJECT-IDENTITY
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpConditions(2) lgpConditionsWellKnown(1) lgpConditionEmergencyTransferToInverter(85)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpConditions(2) lgpConditionsWellKnown(1) lgpConditionEmergencyTransferToInverter(85)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpConditions(2) lgpConditionsWellKnown(1) lgpConditionEmergencyTransferToInverter(85)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpConditions(2) lgpConditionsWellKnown(1) lgpConditionEmergencyTransferToInverter(85)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpConditions(2) lgpConditionsWellKnown(1) lgpConditionEmergencyTransferToInverter(85)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpConditions(2) lgpConditionsWellKnown(1) lgpConditionEmergencyTransferToInverter(85)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpConditions/lgpConditionsWellKnown/lgpConditionEmergencyTransferToInverter
  • /iso/identified-organization/dod/internet/private/enterprises/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpConditions/lgpConditionsWellKnown/lgpConditionEmergencyTransferToInverter
  • /iso/org/dod/internet/private/enterprise/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpConditions/lgpConditionsWellKnown/lgpConditionEmergencyTransferToInverter
  • /iso/org/dod/internet/private/enterprises/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpConditions/lgpConditionsWellKnown/lgpConditionEmergencyTransferToInverter
  • /iso/iso-identified-organization/dod/internet/private/enterprise/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpConditions/lgpConditionsWellKnown/lgpConditionEmergencyTransferToInverter
  • /iso/iso-identified-organization/dod/internet/private/enterprises/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpConditions/lgpConditionsWellKnown/lgpConditionEmergencyTransferToInverter
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/476/1/42/3/2/1/85

    Description by mibdepot

    The system has detected an emergency transfer of the load to
    inverter.

    Parsed from file LIEBERT_GP_COND.MIB.txt
    Company: None
    Module: LIEBERT-GP-CONDITIONS-MIB

    Description by circitor

    The system has detected an emergency transfer of the load to
    inverter.

    Parsed from file LIEBERT-GP-CONDITIONS-MIB.mib
    Module: LIEBERT-GP-CONDITIONS-MIB

    Information by oid_info

    Vendor: Emerson Computer PowerRoger Draper
    Module: LIEBERT-GP-CONDITIONS-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    lgpConditionEmergencyTransferToInverter OBJECT-IDENTITY STATUS current DESCRIPTION "The system has detected an emergency transfer of the load to inverter." ::= { lgpConditionsWellKnown 85 }

    Information by circitor

    lgpConditionEmergencyTransferToInverter OBJECT-IDENTITY STATUS current DESCRIPTION "The system has detected an emergency transfer of the load to inverter." ::= { lgpConditionsWellKnown 85 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.476)

    [email protected]

    Brothers (219)

    To many brothers! Only 100 nearest brothers are shown.

    OIDNameSub childrenSub Nodes TotalDescription
    ...
    1.3.6.1.4.1.476.1.42.3.2.1.35 lgpConditionLogicFailure 0 0 The system has detected a control logic failure.
    1.3.6.1.4.1.476.1.42.3.2.1.36 lgpConditionPowerSupplyFault 2 2 This system had detected a power supply fault condition.
    1.3.6.1.4.1.476.1.42.3.2.1.37 lgpConditionPowerSupplyFailure 6 6 This system has detected a power supply failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.38 lgpConditionOverVoltage 8 12 This system has detected an over voltage condition.
    1.3.6.1.4.1.476.1.42.3.2.1.39 lgpConditionUnderVoltage 10 14 This system has detected an under voltage condition.
    1.3.6.1.4.1.476.1.42.3.2.1.40 lgpConditionOverload 8 11 This system has detected an overload condition.
    1.3.6.1.4.1.476.1.42.3.2.1.41 lgpConditionScrShort 4 4 This system has detected a Silicon Controlled Rectifier (SCR)
    short condition.
    1.3.6.1.4.1.476.1.42.3.2.1.42 lgpConditionScrOpen 3 3 This system has detected a Silicon Controlled Rectifier (SCR)
    open condition.
    1.3.6.1.4.1.476.1.42.3.2.1.43 lgpConditionFanFailure 3 3 This system has detected a fan failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.44 lgpConditionTransferInhibited 0 0 The system is preventing a transfer of the load to the alternate
    source.
    1.3.6.1.4.1.476.1.42.3.2.1.45 lgpConditionAutoReTransferPrimed 0 0 The system is capable to retransfer to the preferred source.
    1.3.6.1.4.1.476.1.42.3.2.1.46 lgpConditionSourcesOutOfSync 0 0 The system has detected that the input sources are not within the
    specified phase difference (synchronization window).
    1.3.6.1.4.1.476.1.42.3.2.1.47 lgpConditionSourceFailure 2 2 This system has detected an input source failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.48 lgpConditionAutoReTransferInhibited 0 0 The system is preventing a transfer of the load back to the prefered
    source.
    1.3.6.1.4.1.476.1.42.3.2.1.49 lgpConditionAutoReTransferFailed 0 0 The system is failing to automatically retransfer the load back to the
    preferred source.
    1.3.6.1.4.1.476.1.42.3.2.1.50 lgpConditionFuseOpen 6 6 This system has detected an open fuse condition.
    1.3.6.1.4.1.476.1.42.3.2.1.51 lgpConditionDisconnect 16 24 The system has detected a disconnect condition.
    1.3.6.1.4.1.476.1.42.3.2.1.52 lgpConditionFrequencyDeviation 5 5 This system has detected a frequency deviation condition.
    The frequency of a source is outside of the pre-determined thresholds
    f…
    1.3.6.1.4.1.476.1.42.3.2.1.53 lgpConditionOverCurrent 10 16 This system has detected an current condition. The current of a
    source has risen above a pre-determined threshold for a device,…
    1.3.6.1.4.1.476.1.42.3.2.1.54 lgpConditionSensorFailure 17 17 This system has detected a sensor failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.55 lgpConditionInternalCommunicationFailure 0 0 This system has detected an internal communication failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.56 lgpConditionExternalCommunicationFailure 0 0 This system has detected an external communication failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.57 lgpConditionSourceGateDriveFailure 2 2 This system has detected a source gate drive failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.58 lgpConditionDisconnectFailure 5 5 This system has detected a disconnect failure condition.
    A disconnect is a device which disconnects a conductor of a circuit
    from…
    1.3.6.1.4.1.476.1.42.3.2.1.59 lgpConditionOverTemperature 16 16 This system has detected an over temperature condition.
    1.3.6.1.4.1.476.1.42.3.2.1.60 lgpConditionLoadOnAlternateSource 0 0 The system has detected that the load is being supplied by the
    alternate source.
    1.3.6.1.4.1.476.1.42.3.2.1.61 lgpConditionPhaseRotationError 4 4 This system has detected a phase rotation error condition.
    1.3.6.1.4.1.476.1.42.3.2.1.62 lgpConditionControlModuleFailure 1 1 This system has detected a control module failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.63 lgpConditionHistoryLogFull 0 0 The system has detected the history log is full.
    1.3.6.1.4.1.476.1.42.3.2.1.64 lgpConditionConfigurationModified 0 0 The system has detected the configuration has been modified.
    1.3.6.1.4.1.476.1.42.3.2.1.65 lgpConditionPasswordModified 0 0 The system has detected the password has been modified.
    1.3.6.1.4.1.476.1.42.3.2.1.66 lgpConditionTimeModified 0 0 The system has detected the time has been modified.
    1.3.6.1.4.1.476.1.42.3.2.1.67 lgpConditionDateModified 0 0 The system has detected the date has been modified.
    1.3.6.1.4.1.476.1.42.3.2.1.68 lgpConditionEventLogCleared 0 0 The system has detected the event log has been cleared.
    1.3.6.1.4.1.476.1.42.3.2.1.69 lgpConditionHistoryLogCleared 0 0 The system has detected the history log has been cleared.
    1.3.6.1.4.1.476.1.42.3.2.1.70 lgpConditionUtilityFailure 0 0 The system has detected a utility failure.
    1.3.6.1.4.1.476.1.42.3.2.1.71 lgpConditionBatteryTestInProgress 0 0 The system is performing a battery test at this time.
    1.3.6.1.4.1.476.1.42.3.2.1.72 lgpConditionLoadOnBattery 0 0 The system load is being supported by the battery.
    1.3.6.1.4.1.476.1.42.3.2.1.74 lgpConditionReplaceBattery 0 0 The system has detected the batteries are due to be replaced.
    1.3.6.1.4.1.476.1.42.3.2.1.75 lgpConditionUpsShutdownPending 0 0 The system is in a shutdown pending condition.
    1.3.6.1.4.1.476.1.42.3.2.1.76 lgpConditionBatteryChargerFailed 0 0 The system has detected the battery charger has failed.
    1.3.6.1.4.1.476.1.42.3.2.1.77 lgpConditionBypassVoltageUnqualified 0 0 The system has detected the bypass voltage is unqualified.
    The voltage measurement is outside a pre-determined threshold range f…
    1.3.6.1.4.1.476.1.42.3.2.1.78 lgpConditionCheckAirFilter 0 0 The system has detected it is time to check the air filter.
    1.3.6.1.4.1.476.1.42.3.2.1.79 lgpConditionBrownOut 0 0 The system has detected a brown out condition.
    1.3.6.1.4.1.476.1.42.3.2.1.80 lgpConditionMultipleTransferLockout 0 0 The system has locked out transfers to bypass. Too many transfers
    have occured over a specified amount of time.
    1.3.6.1.4.1.476.1.42.3.2.1.81 lgpConditionBypassPhaseLost 0 0 The system has detected one or more bypass phases are missing.
    1.3.6.1.4.1.476.1.42.3.2.1.82 lgpConditionMaintenceBypassInhibited 0 0 The system is preventing a transfer of the load to maintence bypass.
    1.3.6.1.4.1.476.1.42.3.2.1.83 lgpConditionLoadLockedOnBypass 0 0 The system has detected an error and been put locked on bypass.
    1.3.6.1.4.1.476.1.42.3.2.1.84 lgpConditionOutputToLoadShort 0 0 The system has detected an output to load short circuit condition.
    1.3.6.1.4.1.476.1.42.3.2.1.86 lgpConditonEmergencyPowerOff 0 0 The system has detected an Emergency Power Off (EPO) condition.
    An external EPO switch has cut off the power source to the syste…
    1.3.6.1.4.1.476.1.42.3.2.1.87 lgpConditionInverterBackFeed 0 0 The system has detected an inverter backfeed condition. The inverter
    is feeding power through the bypass back to the input.
    1.3.6.1.4.1.476.1.42.3.2.1.88 lgpConditionDcGroundFault 2 2 The system has detected a DC ground fault.
    1.3.6.1.4.1.476.1.42.3.2.1.89 lgpConditionStaticTransferSwitchInhibited 0 0 None
    1.3.6.1.4.1.476.1.42.3.2.1.90 lgpConditionBatteryLogFullWarning 0 0 None
    1.3.6.1.4.1.476.1.42.3.2.1.91 lgpConditionInputCurrentUnbalanced 0 0 None
    1.3.6.1.4.1.476.1.42.3.2.1.92 lgpConditionSelfTestFailed 0 0 lgpConditionSelftestFailed
    1.3.6.1.4.1.476.1.42.3.2.1.93 lgpConditionInverterOutOfSynchronization 0 0 None
    1.3.6.1.4.1.476.1.42.3.2.1.94 lgpConditionModuleAlarm 8 8 This system has detected an alarm within the multi-module system.
    1.3.6.1.4.1.476.1.42.3.2.1.95 lgpConditionActiveModuleAlarm 0 0 The system has detected an active alarm in one, or more, of the
    sub-modules of the multi-module system.
    1.3.6.1.4.1.476.1.42.3.2.1.96 lgpConditionControlFailure 4 4 This system has detected a control failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.97 lgpConditionControlWarning 2 2 This system has detected a control warning conditions.
    1.3.6.1.4.1.476.1.42.3.2.1.98 lgpConditionUserInterfaceFailure 0 0 The system has detected a user interface control failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.99 lgpConditionLostPowerRedundancy 0 0 The system has detected the number of redundant power modules has
    fallen below the minimum redundant power module setting.
    1.3.6.1.4.1.476.1.42.3.2.1.100 lgpConditionPowerModuleFailure 0 0 The system has detected a power module failure condition in the
    system.
    1.3.6.1.4.1.476.1.42.3.2.1.101 lgpConditionBatteryModuleFailure 0 0 The system has detected a battery module failure condition in the
    system.
    1.3.6.1.4.1.476.1.42.3.2.1.102 lgpConditionOutputToLoadOff 0 0 The system has detected that there is no power being supplied to the
    load.
    1.3.6.1.4.1.476.1.42.3.2.1.103 lgpConditionSystemOff 0 0 The system is off.
    1.3.6.1.4.1.476.1.42.3.2.1.104 lgpConditionRectifierStartupFailure 0 0 The system has detected a rectifier under voltage start-up failure
    condition.
    1.3.6.1.4.1.476.1.42.3.2.1.105 lgpConditionRectifierFault 0 0 The system has detected a rectifier fault condition.
    1.3.6.1.4.1.476.1.42.3.2.1.106 lgpConditionInverterShutdownLowDc 0 0 The system has shutdown the inverter due to a DC bus under voltage.
    1.3.6.1.4.1.476.1.42.3.2.1.107 lgpConditionInverterFault 0 0 The system has detected an inverter fault condition.
    1.3.6.1.4.1.476.1.42.3.2.1.108 lgpConditionInverterDcOffsetOverrun 0 0 The system has detected an over run of the inverter DC offset
    voltage.
    1.3.6.1.4.1.476.1.42.3.2.1.109 lgpConditionParallelSysLowBatteryWarning 0 0 The parallel system has detected a low battery warning condition.
    1.3.6.1.4.1.476.1.42.3.2.1.110 lgpConditionParallelSysLoadShareFault 0 0 The parallel system has detected a load share fault condition.
    1.3.6.1.4.1.476.1.42.3.2.1.111 lgpConditionBatteryFault 0 0 The system has detected a battery fault condition. The battery
    conductors are either reversed or disconnected.
    1.3.6.1.4.1.476.1.42.3.2.1.112 lgpConditionBatteryConverterFailure 0 0 The system has detected a battery converter failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.113 lgpConditionBatteryBalancerFault 0 0 The system has detected a battery balancer fault condition.
    1.3.6.1.4.1.476.1.42.3.2.1.114 lgpConditionpsUpsOperationFault 0 0 The system has detected an operation fault. The UPS attempted to
    transfer to maintenance bypass without following the proper se…
    1.3.6.1.4.1.476.1.42.3.2.1.115 lgpConditionOutputToLoadOnJointMode 0 0 The system load is being supported by both the battery and rectifier.
    1.3.6.1.4.1.476.1.42.3.2.1.116 lgpConditionInputNeutralLost 0 0 The system had detected the main input neutral is disconnected.
    1.3.6.1.4.1.476.1.42.3.2.1.117 lgpConditionLowBatteryWarning 0 0 The battery's remaining charge is less than or equal to the
    configured low threshold.
    1.3.6.1.4.1.476.1.42.3.2.1.118 lgpConditionInternalFault 0 0 The system has detected an internal fault.
    1.3.6.1.4.1.476.1.42.3.2.1.119 lgpConditionBatteryTestFailed 0 0 The system has detected a battery self-test failure.
    1.3.6.1.4.1.476.1.42.3.2.1.120 lgpConditionPowerModuleWarning 0 0 The system has detected an alarm condition on one, or more,
    power modules.
    1.3.6.1.4.1.476.1.42.3.2.1.121 lgpConditionBatteryModuleWarning 0 0 The system has detected an alarm condition on one, or more,
    battery modules.
    1.3.6.1.4.1.476.1.42.3.2.1.122 lgpConditionControlModuleWarning 0 0 The system has detected a control module warning.
    1.3.6.1.4.1.476.1.42.3.2.1.123 lgpConditionUpsOperationFault 0 0 The system has detected an operation fault. The UPS attempted to
    transfer to maintenance bypass without following the proper se…
    1.3.6.1.4.1.476.1.42.3.2.1.124 lgpConditionActiveAlarm 0 0 The system has detected an alarm condition.
    1.3.6.1.4.1.476.1.42.3.2.1.125 lgpConditionRectifierCommunicationFailure 0 0 The system has detected an internal communication failure
    condition with the rectifier.
    1.3.6.1.4.1.476.1.42.3.2.1.126 lgpConditionInverterCommunicationFailure 0 0 The system has detected an internal communication failure
    condition with the inverter.
    1.3.6.1.4.1.476.1.42.3.2.1.127 lgpConditionParallelSysConnectionFault 0 0 The parallel system has detected a connection fault.
    One or more of the devices are not properly connected.
    1.3.6.1.4.1.476.1.42.3.2.1.128 lgpConditionParallelSysCommunicationFailure 0 0 The parallel system has detected a communication failure.
    1.3.6.1.4.1.476.1.42.3.2.1.129 lgpConditionLostBatteryRedundancy 0 0 The system has detected the number of redundant battery modules has
    fallen below the configured redundant battery module thresho…
    1.3.6.1.4.1.476.1.42.3.2.1.130 lgpConditionCompPumpDownFailure 2 2 The system has detected that a compressor has failed to pump down.
    1.3.6.1.4.1.476.1.42.3.2.1.131 lgpConditionChilledWaterLowWaterFlow 0 0 The system has detected a chilled water low water flow condition.
    1.3.6.1.4.1.476.1.42.3.2.1.132 lgpConditionAirFilterClogged 0 0 The system has detected a air filter clogged condition.
    1.3.6.1.4.1.476.1.42.3.2.1.133 lgpConditionHumidifierFailure 0 0 The system has detected a humidifier failure condition.
    1.3.6.1.4.1.476.1.42.3.2.1.134 lgpConditionRunHoursExceeded 11 11 The system has detected a pre-determined run hours threshold has been
    exceeded.
    1.3.6.1.4.1.476.1.42.3.2.1.135 lgpConditionCommWarning 16 16 The system has detected a loss of communications with another
    module.
    ...