This sub-tree registers well known Liebert Power Measurement
Types. The object identifier names usually encompass units of
measure, lines of reference, and device location. The OID's
name usually implies a measurement type such as 'voltsAC',
'current', 'voltsDc', 'VoltsLL', etc.
Parsed from file LIEBERT_GP_POWER.MIB.txt
Company: None
Module: LIEBERT-GP-POWER-MIB
This sub-tree registers well known Liebert Power Measurement
Types. The object identifier names usually encompass units of
measure, lines of reference, and device location. The OID's
name usually implies a measurement type such as 'voltsAC',
'current', 'voltsDc', 'VoltsLL', etc.
Parsed from file LIEBERT-GP-POWER-MIB.mib
Module: LIEBERT-GP-POWER-MIB
Vendor: Emerson Computer PowerRoger Draper
Module: LIEBERT-GP-POWER-MIB
[Automatically extracted from oidview.com]
lgpPwrWellKnownMeasurementTypes OBJECT-IDENTITY STATUS current DESCRIPTION "This sub-tree registers well known Liebert Power Measurement Types. The object identifier names usually encompass units of measure, lines of reference, and device location. The OID's name usually implies a measurement type such as 'voltsAC', 'current', 'voltsDc', 'VoltsLL', etc." ::= { lgpPwrMeasurements 5 }
lgpPwrWellKnownMeasurementTypes OBJECT-IDENTITY STATUS current DESCRIPTION "This sub-tree registers well known Liebert Power Measurement Types. The object identifier names usually encompass units of measure, lines of reference, and device location. The OID's name usually implies a measurement type such as 'voltsAC', 'current', 'voltsDc', 'VoltsLL', etc." ::= { lgpPwrMeasurements 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.2.5.1 | lgpPwrVoltsAc | 0 | 0 | This identifier represents an AC voltage. |
1.3.6.1.4.1.476.1.42.3.5.2.5.2 | lgpPwrVoltsDc | 0 | 0 | This identifier represents a DC voltage. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.2.1 | lgpPwrWellKnownMeasurementPoints | 10 | 10 | This sub-tree registers well known Liebert Power Measurement Points. The object identifier names usually imply locations where t… |
1.3.6.1.4.1.476.1.42.3.5.2.2 | lgpPwrMeasurementPointTable | 1 | 19 | This table contains a list of AC power measurement point entries. The table contains zero, one, or many rows, depending upon the… |
1.3.6.1.4.1.476.1.42.3.5.2.3 | lgpPwrLineMeasurementTable | 1 | 22 | A list of power measurements for each phase/line for a given power measurement point/location in the 'lgpPwrMeasurementPointTabl… |
1.3.6.1.4.1.476.1.42.3.5.2.4 | lgpPwrDcMeasurementPointTable | 1 | 8 | This table contains a list of DC power measurement point entries. The table contains zero, one, or many rows, depending upon the… |