Descriptions may differ between sources. The primary description is shown first.
Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniEthernetSubIfRowStatus
juniEthernetSubIfLowerIfIndex
In addition, when creating an entry the following conditions must hold:
A value for juniEthernetSubIfIndex must have been determined
previously, by reading juniEthernetSubIfNextIfIndex.
The interface identified by juniEthernetSubIfLowerIfIndex must
exist, and must be a Ethernet interface.
A positive value configured for juniEthernetSubIfId must not already
be assigned to another subinterface layered onto the same underlying
Ethernet interface.
A corresponding entry in ifTable/ifXTable/juniIfTable is
created/destroyed as a result of creating/destroying an entry in this
table.
Parsed from file
Juniper-ETHERNET-MIB.mib
Module: Juniper-ETHERNET-MIB
Source file: Download Juniper-ETHERNET-MIB
· Publisher's file
Copy from Observium Community; File: junose/Juniper-ETHERNET-MIB; 43,264 bytes
Vendor MIB copy from the Observium Community archive.
Related source files and packages:
Source file: Download Juniper-ETHERNET-MIB
· Publisher's file
Copy from LibreNMS; File: juniper/junose/Juniper-ETHERNET-MIB; 42,177 bytes
Vendor MIB copy from the LibreNMS archive.
Related source files and packages:
Source file: Download Juniper-ETHERNET-MIB.mib
Publisher path: Mibs; 43,264 bytes
Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniEthernetSubIfRowStatus
juniEthernetSubIfLowerIfIndex
In addition, when creating an entry the following conditions must hold:
A value for juniEthernetSubIfIndex must have been determined
previously, by reading juniEthernetSubIfNextIfIndex.
The interface identified by juniEthernetSubIfLowerIfIndex must
exist, and must be a Ethernet interface.
A positive value configured for juniEthernetSubIfId must not already
be assigned to another subinterface layered onto the same underlying
Ethernet interface.
A corresponding entry in ifTable/ifXTable/juniIfTable is
created/destroyed as a result of creating/destroying an entry in this
table.
Source file: Download juniEthernet.mi2.txt
File: juniper/juniEthernet.mi2.txt; 43,242 bytes
usdEthernetSubIfRowStatus — Circitor, MIBdepot
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: usdEthernetSubIfRowStatus usdEthernetSubIfLowerIfIndex In addition, when creating an entry the following conditions must hold: A value for usdEthernetSubIfIndex must have been determined previously, by reading usdEthernetSubIfNextIfIndex. The interface identified by usdEthernetSubIfLowerIfIndex must exist, and must be a Ethernet interface. A positive value configured for usdEthernetSubIfId must not already be assigned to another subinterface layered onto the same underlying Ethernet interface. A corresponding entry in ifTable/ifXTable/usdIfTable is created/destroyed as a result of creating/destroying an entry in this table.