Defines the X.3 parameter 19, Editing PAD service signals. This parameter
provides the start-stop mode DTE (user) with the ability to decide whether or
not editing PAD service signals are transmitted and which format should be used.
Range of Values:
0 = No editing PAD service signals
1: Editing PAD service signals for printing terminals
2: Editing PAD service signals for display terminals
8, 32 to 126: Editing PAD service signals using one character from the range of IA5
Default Value: 0
Configuration Changed: Operative
Parsed from file CXASYNC.MIB.txt
Company: None
Module: CXAsync-MIB
Defines the X.3 parameter 19, Editing PAD service signals. This parameter
provides the start-stop mode DTE (user) with the ability to decide whether or
not editing PAD service signals are transmitted and which format should be used.
Range of Values:
0 = No editing PAD service signals
1: Editing PAD service signals for printing terminals
2: Editing PAD service signals for display terminals
8, 32 to 126: Editing PAD service signals using one character from the range of IA5
Default Value: 0
Configuration Changed: Operative
Parsed from file CXAsync-MIB.mib
Module: CXAsync-MIB
Vendor: Memotec Communications
Module: CXAsync-MIB
[Automatically extracted from oidview.com]
asySapProfParameter19 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the X.3 parameter 19, Editing PAD service signals. This parameter provides the start-stop mode DTE (user) with the ability to decide whether or not editing PAD service signals are transmitted and which format should be used. Range of Values: 0 = No editing PAD service signals 1: Editing PAD service signals for printing terminals 2: Editing PAD service signals for display terminals 8, 32 to 126: Editing PAD service signals using one character from the range of IA5 Default Value: 0 Configuration Changed: Operative" REFERENCE "CCITT X.3 Table 1" DEFVAL { 0 } ::= { asySapProfEntry 23 }
asySapProfParameter19 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the X.3 parameter 19, Editing PAD service signals. This parameter provides the start-stop mode DTE (user) with the ability to decide whether or not editing PAD service signals are transmitted and which format should be used. Range of Values: 0 = No editing PAD service signals 1: Editing PAD service signals for printing terminals 2: Editing PAD service signals for display terminals 8, 32 to 126: Editing PAD service signals using one character from the range of IA5 Default Value: 0 Configuration Changed: Operative" REFERENCE "CCITT X.3 Table 1" DEFVAL { 0 } ::= { asySapProfEntry 23 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.495.2.1.6.30.22.1.1 | asySapProfSapNumber | 0 | 0 | Identifies the SAP (service access point) using a unique numerical value. |
1.3.6.1.4.1.495.2.1.6.30.22.1.5 | asySapProfParameter1 | 0 | 0 | Defines the X.3 parameter 1, PAD recall using a character. This parameter allows the start-stop mode DTE (user) to initiate an … |
1.3.6.1.4.1.495.2.1.6.30.22.1.6 | asySapProfParameter2 | 0 | 0 | Defines the X.3 parameter 2, Echo. This parameter provides for characters received from the start-stop mode DTE (user) to be tra… |
1.3.6.1.4.1.495.2.1.6.30.22.1.7 | asySapProfParameter3 | 0 | 0 | Defines the X.3 parameter 3, Selection of data forwarding character(s). This parameter allows the selection of defined sets of … |
1.3.6.1.4.1.495.2.1.6.30.22.1.8 | asySapProfParameter4 | 0 | 0 | Defines the X.3 parameter 4, Selection of idle timer delay, in tenths of a second. This parameter allows the selection of the d… |
1.3.6.1.4.1.495.2.1.6.30.22.1.9 | asySapProfParameter5 | 0 | 0 | Defines the X.3 parameter 5, Ancillary device control. This parameter allows for flow control between the PAD and the start-sto… |
1.3.6.1.4.1.495.2.1.6.30.22.1.10 | asySapProfParameter6 | 0 | 0 | Defines the X.3 parameter 6, Control of PAD service signals and PAD command signals. This parameter provides the start-stop mod… |
1.3.6.1.4.1.495.2.1.6.30.22.1.11 | asySapProfParameter7 | 0 | 0 | Defines the X.3 parameter 7, Selection of operation of the PAD on receipt of a break signal from the start-stop mode DTE. This … |
1.3.6.1.4.1.495.2.1.6.30.22.1.12 | asySapProfParameter8 | 0 | 0 | Defines the X.3 parameter 8, Discard output. This parameter provides for a PAD to discard the content of user sequences in pack… |
1.3.6.1.4.1.495.2.1.6.30.22.1.13 | asySapProfParameter9 | 0 | 0 | Defines the X.3 parameter 9, Padding after carriage return (CR). This parameter provides for the automatic insertion of padding… |
1.3.6.1.4.1.495.2.1.6.30.22.1.14 | asySapProfParameter10 | 0 | 0 | Defines the X.3 parameter 10, Line folding. This parameter provides for the automatic insertion of graphic characters by the PA… |
1.3.6.1.4.1.495.2.1.6.30.22.1.15 | asySapProfParameter11 | 0 | 0 | Defines the X.3 parameter 11, Binary speed of start-stop mode DTE. Options: 0: 110 bit/s 1: 134.5 bit/s 2: 300 bit/s 3: 1200 bit/s 4:… |
1.3.6.1.4.1.495.2.1.6.30.22.1.16 | asySapProfParameter12 | 0 | 0 | Defines the X.3 parameter 12, Flow control of the PAD. This parameter allows for flow control between the start-stop mode DTE (… |
1.3.6.1.4.1.495.2.1.6.30.22.1.17 | asySapProfParameter13 | 0 | 0 | Defines the X.3 parameter 13, Linefeed insertion after carriage return. This parameter allows for the automatic insertion of a … |
1.3.6.1.4.1.495.2.1.6.30.22.1.18 | asySapProfParameter14 | 0 | 0 | Defines the X.3 parameter 14, Padding after linefeed. This parameter provides for the automatic insertion of padding characters… |
1.3.6.1.4.1.495.2.1.6.30.22.1.19 | asySapProfParameter15 | 0 | 0 | Defines the X.3 parameter 15, Editing. This parameter provides for character size delete, line delete and line display editing c… |
1.3.6.1.4.1.495.2.1.6.30.22.1.20 | asySapProfParameter16 | 0 | 0 | Defines the X.3 parameter 16, Character delete. Range of Values: 0 to 127 0 to126: One character from IA5 127: Character 7/15 (DEL… |
1.3.6.1.4.1.495.2.1.6.30.22.1.21 | asySapProfParameter17 | 0 | 0 | Defines the X.3 parameter 17, Line delete. Range of Values: 0 to 127 0 to 23: One character from the range of IA5 24: Character 1… |
1.3.6.1.4.1.495.2.1.6.30.22.1.22 | asySapProfParameter18 | 0 | 0 | Defines the X.3 parameter 18, Line display. Range of Values: 0 to 127 0 to 17: One character from the range of IA5 18: Character 1… |
1.3.6.1.4.1.495.2.1.6.30.22.1.24 | asySapProfParameter20 | 0 | 0 | Defines the X.3 parameter 20, Echo mask. This parameter allows selected defined sets of characters received from the start-stop… |
1.3.6.1.4.1.495.2.1.6.30.22.1.25 | asySapProfParameter21 | 0 | 0 | Defines the X.3 parameter 21, Parity treatment. This parameter allows the PAD to check parity in the data stream from the start… |
1.3.6.1.4.1.495.2.1.6.30.22.1.26 | asySapProfParameter22 | 0 | 0 | Defines the X.3 parameter 22, Page wait. This parameter allows the PAD to suspend transmission of additional characters to the … |
1.3.6.1.4.1.495.2.1.6.30.22.1.27 | asySapProfParameter23 | 0 | 0 | Defines parameter 23 (extension to X.3), Receive parity type. Options: 0: Parity disable 1: Even parity 2: Odd parity 3: Space parit… |
1.3.6.1.4.1.495.2.1.6.30.22.1.28 | asySapProfParameter24 | 0 | 0 | Defines parameter 24 (extension to X.3), Transmit parity type. Options: 0: Parity disable 1: Even parity 2: Odd parity 3: Space pari… |
1.3.6.1.4.1.495.2.1.6.30.22.1.29 | asySapProfParameter25 | 0 | 0 | Defines parameter 25 (extension to X.3), Flow control on character to PAD. Range of Values: 0 to 127 0 to 18: One character from … |
1.3.6.1.4.1.495.2.1.6.30.22.1.30 | asySapProfParameter26 | 0 | 0 | Defines parameter 26 (extension to X.3), Flow control off character to PAD. Range of Values: 0 to 127 0 to 16: One character from… |
1.3.6.1.4.1.495.2.1.6.30.22.1.31 | asySapProfParameter27 | 0 | 0 | Defines parameter 27 (extension to X.3), Flow control on character to ancillary device. Range of Values: 0 to 127 Note: 0 to 18: On… |
1.3.6.1.4.1.495.2.1.6.30.22.1.32 | asySapProfParameter28 | 0 | 0 | Defines parameter 28 (extension to X.3), Flow control off character to ancillary device. Range of Values: 0 to 127 0 to 16: One ch… |