A temperature inside the chassis on the sending device has returned
to normal operating temperature. The sysHwTemperature
object identifies the current status.
Parsed from file ctron-ssr-trap.txt
Company: None
Module: CTRON-SSR-TRAP-MIB
A temperature inside the chassis on the sending device has returned
to normal operating temperature. The sysHwTemperature
object identifies the current status.
Parsed from file CTRON-SSR-TRAP-MIB.mib
Module: CTRON-SSR-TRAP-MIB
envTempNormal NOTIFICATION-TYPE OBJECTS { sysHwTemperature } STATUS current DESCRIPTION "A temperature inside the chassis on the sending device has returned to normal operating temperature. The sysHwTemperature object identifies the current status." ::= { envTrapGroup 6 }
Vendor: Enterasys Networks Inc.
Module: CTRON-SSR-TRAP-MIB
[Automatically extracted from oidview.com]
envTempNormal NOTIFICATION-TYPE OBJECTS { sysHwTemperature } STATUS current DESCRIPTION "A temperature inside the chassis on the sending device has returned to normal operating temperature. The sysHwTemperature object identifies the current status." ::= { envTrapGroup 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.52.2501.10.2.1 | envPowerSupplyFailed | 0 | 0 | A power supply on the sending device has failed. The sysHwPowerSupply object identifies the failed supply. |
1.3.6.1.4.1.52.2501.10.2.2 | envPowerSupplyRecovered | 0 | 0 | A power supply on the sending device has recovered after failure. The sysHwPowerSupply object identifies the recovered supply. |
1.3.6.1.4.1.52.2501.10.2.3 | envFanFailed | 0 | 0 | A Fan tray on the sending device has failed. The sysHwFan object identifies the failed fan tray. |
1.3.6.1.4.1.52.2501.10.2.4 | envFanRecovered | 0 | 0 | A Fan tray on the sending device has recovered after failure. The sysHwFan object identifies the recovered Fan tray. |
1.3.6.1.4.1.52.2501.10.2.5 | envTempExceeded | 0 | 0 | A temperature inside the chassis on the sending device has exceeded normal operating temperature. The sysHwTemperature object ide… |
1.3.6.1.4.1.52.2501.10.2.7 | envHotSwapIn | 0 | 0 | A module has been inserted into the chassis. sysHwModuleSlotNumber identifies the slot the module was inserted into. |
1.3.6.1.4.1.52.2501.10.2.8 | envHotSwapOut | 0 | 0 | A module has been turned off or removed from the chassis. sysHwModuleSlotNumber identifies the slot the module was removed from. |
1.3.6.1.4.1.52.2501.10.2.9 | envBackupControlModuleOnline | 0 | 0 | A backup control module that was in standby mode has taken over for a failed primary control module. Poll sysHwControlModuleBack… |
1.3.6.1.4.1.52.2501.10.2.10 | envBackupControlModuleFailure | 0 | 0 | A backup control module that was in standby mode has changed to inactive or notInstalled. Poll sysHwControlModuleBackupState for … |
1.3.6.1.4.1.52.2501.10.2.11 | envLineModuleFailure | 0 | 0 | A line card module which was in the online state changed to the offline state indicating an error condition. |
1.3.6.1.4.1.52.2501.10.2.12 | envCPUThresholdExceeded | 0 | 0 | The CPU utilization has exceeded the value of capCPUMaxThreshold after having been below the value of capCPUMinThreshold. Once th… |