The UPS is at low condition status.
Parsed from file mg-ups.mib.txt
Company: None
Module: MG-SNMP-UPS-MIB
The UPS is at low condition status.
Parsed from file MG-SNMP-UPS-MIB.mib
Module: MG-SNMP-UPS-MIB
Vendor: Merlin Gerin
Module: MG-SNMP-UPS-MIB
[Automatically extracted from oidview.com]
upsBatteryLowCondition OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The UPS is at low condition status." ::= { upsBattery 16 }
upsmgBatteryLowCondition OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The UPS is at low condition status." ::= { upsmgBattery 16 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.705.1.5.16.0 | upsBatteryLowCondition | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.705.1.5.1 | upsmgBatteryRemainingTime, upsBatteryRemainingTime | 1 | 1 | The time remaining actual charge vs actual load (dynamic). |
1.3.6.1.4.1.705.1.5.2 | upsmgBatteryLevel, upsBatteryLevel | 1 | 1 | The battery level as a percentage of charge. |
1.3.6.1.4.1.705.1.5.3 | upsmgBatteryRechargeTime, upsBatteryRechargeTime | 1 | 1 | The actual operational battery recharge time to set point equal to upsConfigRechargeLevel. This value is computed from upsConfigR… |
1.3.6.1.4.1.705.1.5.4 | upsmgBatteryRechargeLevel, upsBatteryRechargeLevel | 1 | 1 | The actual value of the battery recharge level that will be reached during the time delay necessary to restart after power return… |
1.3.6.1.4.1.705.1.5.5 | upsmgBatteryVoltage, upsBatteryVoltage | 1 | 1 | The actual battery voltage. |
1.3.6.1.4.1.705.1.5.6 | upsmgBatteryCurrent, upsBatteryCurrent | 1 | 1 | The actual battery current. |
1.3.6.1.4.1.705.1.5.7 | upsmgBatteryTemperature, upsBatteryTemperature | 1 | 1 | The battery temperature. |
1.3.6.1.4.1.705.1.5.8 | upsmgBatteryFullRechargeTime, upsBatteryFullRechargeTime | 1 | 1 | The battery full recharge time (from 0 to 100 percent) at current load. |
1.3.6.1.4.1.705.1.5.9 | upsmgBatteryFaultBattery, upsBatteryFaultBattery | 1 | 1 | The battery fault status. |
1.3.6.1.4.1.705.1.5.10 | upsmgBatteryNoBattery, upsBatteryNoBattery | 1 | 1 | The UPS has no Battery status. |
1.3.6.1.4.1.705.1.5.11 | upsmgBatteryReplacement, upsBatteryReplacement | 1 | 1 | The UPS Battery to be replaced status. |
1.3.6.1.4.1.705.1.5.12 | upsmgBatteryUnavailableBattery, upsBatteryUnavailableBattery | 1 | 1 | The UPS Battery is unavailable status. |
1.3.6.1.4.1.705.1.5.13 | upsmgBatteryNotHighCharge, upsBatteryNotHighCharge | 1 | 1 | The UPS Battery quit high condition status. |
1.3.6.1.4.1.705.1.5.14 | upsmgBatteryLowBattery, upsBatteryLowBattery | 1 | 1 | The battery low status. |
1.3.6.1.4.1.705.1.5.15 | upsmgBatteryChargerFault, upsBatteryChargerFault | 1 | 1 | The UPS Battery is not charging status. |
1.3.6.1.4.1.705.1.5.17 | upsmgBatteryLowRecharge, upsBatteryLowRecharge | 1 | 1 | The UPS Battery is not recharged status. |