This variable identifies the maximum number
of errored events that can occur before declaring
the Frame Relay interface down. An errored event
is the non-receipt of a Status Enquiry, or the
receipt of a Status Enquiry with an invalid sequence
number.
This counter is referred to as N392 in the ANSI
standard.
The value for this counter cannot exceed the
value of the monitored events counter (see the
attCNMefrMonitoredEvents object).
Parsed from file att_efr.mib.txt
Company: None
Module: ATT-CNM-ENHANCED-FRAME-RELAY-MIB
This variable identifies the maximum number
of errored events that can occur before declaring
the Frame Relay interface down. An errored event
is the non-receipt of a Status Enquiry, or the
receipt of a Status Enquiry with an invalid sequence
number.
This counter is referred to as N392 in the ANSI
standard.
The value for this counter cannot exceed the
value of the monitored events counter (see the
attCNMefrMonitoredEvents object).
Parsed from file ATT-CNM-ENHANCED-FRAME-RELAY-MIB.mib
Module: ATT-CNM-ENHANCED-FRAME-RELAY-MIB
Vendor: AT&T
Module: ATT-CNM-ENHANCED-FRAME-RELAY-MIB
[Automatically extracted from oidview.com]
attCNMefrErrorThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable identifies the maximum number of errored events that can occur before declaring the Frame Relay interface down. An errored event is the non-receipt of a Status Enquiry, or the receipt of a Status Enquiry with an invalid sequence number. This counter is referred to as N392 in the ANSI standard. The value for this counter cannot exceed the value of the monitored events counter (see the attCNMefrMonitoredEvents object)." ::= { attCNMefrConfigEntry 5 }
attCNMefrErrorThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable identifies the maximum number of errored events that can occur before declaring the Frame Relay interface down. An errored event is the non-receipt of a Status Enquiry, or the receipt of a Status Enquiry with an invalid sequence number. This counter is referred to as N392 in the ANSI standard. The value for this counter cannot exceed the value of the monitored events counter (see the attCNMefrMonitoredEvents object)." ::= { attCNMefrConfigEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.74.2.15.8.1.1.1 | attCNMefrConfigIndex | 0 | 0 | A unique value for each Frame Relay interface. The interface identified by a particular value of this index is the same interface… |
1.3.6.1.4.1.74.2.15.8.1.1.2 | attCNMefrMgmtType | 0 | 0 | This variable identifies the PVC management scheme being used to manage this Frame Relay interface. A value of auto-set(1) indica… |
1.3.6.1.4.1.74.2.15.8.1.1.3 | attCNMefrPollDirection | 0 | 0 | This variable specifies the role the Frame Relay interface performs in a bi-directional PVC management scheme. A value of receive… |
1.3.6.1.4.1.74.2.15.8.1.1.4 | attCNMefrFullStatusPoll | 0 | 0 | This variable identifies the maximum number of Status Enquiry intervals that pass before issuance of a Full Status Enquiry messag… |
1.3.6.1.4.1.74.2.15.8.1.1.6 | attCNMefrMonitoredEvents | 0 | 0 | This variable specifies a value 'm', that is used with the Error Threshold (attCNMefrErrorThreshold) to determine link problems. … |
1.3.6.1.4.1.74.2.15.8.1.1.7 | attCNMefrIntegrityTimer | 0 | 0 | This variable identifies the number of seconds between successive Status Enquiry messages. This timer is referred to as T391 in t… |
1.3.6.1.4.1.74.2.15.8.1.1.8 | attCNMefrPollVerifyTimer | 0 | 0 | This variable specifies the maximum number of seconds the Frame Relay interface allows between the receipt of Status Enquiries. T… |
1.3.6.1.4.1.74.2.15.8.1.1.9 | attCNMefrLMIFlowControl | 0 | 0 | If the PVC management scheme being used is LMI, then this variable indicates whether this Frame Relay interface uses XON/XOFF as … |
1.3.6.1.4.1.74.2.15.8.1.1.10 | attCNMefrSupportedPVCs | 0 | 0 | This variable specifies the number of DLCIs currently supported on this Frame Relay interface. |
1.3.6.1.4.1.74.2.15.8.1.1.11 | attCNMefrMeasMaxIntervals | 0 | 0 | This variable identifies the maximum number of measurement intervals supported for the measurements maintained by this Frame Rela… |
1.3.6.1.4.1.74.2.15.8.1.1.12 | attCNMefrMeasIntervalLen | 0 | 0 | This variable identifies the number of seconds that make up one complete measurement interval for for the measurements maintained… |