This variable identifies the number of seconds
between successive Status Enquiry messages.
This timer is referred to as T391 in the ANSI
standard.
This variable is applicable only if this interface
is configured to be the sender of PVC management
polls (see the attCNMefrPollDirection object).
Parsed from file att_efr.mib.txt
Company: None
Module: ATT-CNM-ENHANCED-FRAME-RELAY-MIB
This variable identifies the number of seconds
between successive Status Enquiry messages.
This timer is referred to as T391 in the ANSI
standard.
This variable is applicable only if this interface
is configured to be the sender of PVC management
polls (see the attCNMefrPollDirection object).
Parsed from file ATT-CNM-ENHANCED-FRAME-RELAY-MIB.mib
Module: ATT-CNM-ENHANCED-FRAME-RELAY-MIB
Vendor: AT&T
Module: ATT-CNM-ENHANCED-FRAME-RELAY-MIB
[Automatically extracted from oidview.com]
attCNMefrIntegrityTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable identifies the number of seconds between successive Status Enquiry messages. This timer is referred to as T391 in the ANSI standard. This variable is applicable only if this interface is configured to be the sender of PVC management polls (see the attCNMefrPollDirection object)." ::= { attCNMefrConfigEntry 7 }
attCNMefrIntegrityTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable identifies the number of seconds between successive Status Enquiry messages. This timer is referred to as T391 in the ANSI standard. This variable is applicable only if this interface is configured to be the sender of PVC management polls (see the attCNMefrPollDirection object)." ::= { attCNMefrConfigEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.74.2.15.8.1.1.1 | attCNMefrConfigIndex | 0 | 0 | A unique value for each Frame Relay interface. The interface identified by a particular value of this index is the same interface… |
1.3.6.1.4.1.74.2.15.8.1.1.2 | attCNMefrMgmtType | 0 | 0 | This variable identifies the PVC management scheme being used to manage this Frame Relay interface. A value of auto-set(1) indica… |
1.3.6.1.4.1.74.2.15.8.1.1.3 | attCNMefrPollDirection | 0 | 0 | This variable specifies the role the Frame Relay interface performs in a bi-directional PVC management scheme. A value of receive… |
1.3.6.1.4.1.74.2.15.8.1.1.4 | attCNMefrFullStatusPoll | 0 | 0 | This variable identifies the maximum number of Status Enquiry intervals that pass before issuance of a Full Status Enquiry messag… |
1.3.6.1.4.1.74.2.15.8.1.1.5 | attCNMefrErrorThreshold | 0 | 0 | This variable identifies the maximum number of errored events that can occur before declaring the Frame Relay interface down. An … |
1.3.6.1.4.1.74.2.15.8.1.1.6 | attCNMefrMonitoredEvents | 0 | 0 | This variable specifies a value 'm', that is used with the Error Threshold (attCNMefrErrorThreshold) to determine link problems. … |
1.3.6.1.4.1.74.2.15.8.1.1.8 | attCNMefrPollVerifyTimer | 0 | 0 | This variable specifies the maximum number of seconds the Frame Relay interface allows between the receipt of Status Enquiries. T… |
1.3.6.1.4.1.74.2.15.8.1.1.9 | attCNMefrLMIFlowControl | 0 | 0 | If the PVC management scheme being used is LMI, then this variable indicates whether this Frame Relay interface uses XON/XOFF as … |
1.3.6.1.4.1.74.2.15.8.1.1.10 | attCNMefrSupportedPVCs | 0 | 0 | This variable specifies the number of DLCIs currently supported on this Frame Relay interface. |
1.3.6.1.4.1.74.2.15.8.1.1.11 | attCNMefrMeasMaxIntervals | 0 | 0 | This variable identifies the maximum number of measurement intervals supported for the measurements maintained by this Frame Rela… |
1.3.6.1.4.1.74.2.15.8.1.1.12 | attCNMefrMeasIntervalLen | 0 | 0 | This variable identifies the number of seconds that make up one complete measurement interval for for the measurements maintained… |