Reference record for OID 1.3.6.1.4.1.850.1.1.8.1


parent
1.3.6.1.4.1.850.1.1.8 (upsTest)
node code
1
node name
upsTestId
dot oid
1.3.6.1.4.1.850.1.1.8.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) tripplite(850) trippUPS1(1) ups(1) upsTest(8) upsTestId(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) tripplite(850) trippUPS1(1) ups(1) upsTest(8) upsTestId(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) tripplite(850) trippUPS1(1) ups(1) upsTest(8) upsTestId(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) tripplite(850) trippUPS1(1) ups(1) upsTest(8) upsTestId(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) tripplite(850) trippUPS1(1) ups(1) upsTest(8) upsTestId(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) tripplite(850) trippUPS1(1) ups(1) upsTest(8) upsTestId(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/tripplite/trippUPS1/ups/upsTest/upsTestId
  • /iso/identified-organization/dod/internet/private/enterprises/tripplite/trippUPS1/ups/upsTest/upsTestId
  • /iso/org/dod/internet/private/enterprise/tripplite/trippUPS1/ups/upsTest/upsTestId
  • /iso/org/dod/internet/private/enterprises/tripplite/trippUPS1/ups/upsTest/upsTestId
  • /iso/iso-identified-organization/dod/internet/private/enterprise/tripplite/trippUPS1/ups/upsTest/upsTestId
  • /iso/iso-identified-organization/dod/internet/private/enterprises/tripplite/trippUPS1/ups/upsTest/upsTestId
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/850/1/1/8/1

    Description by mibdepot

    The test named by an OBJECT IDENTIFIER which
    allows a standard mechanism for the initiation of
    test, including the well known tests identified in
    this document as well as those introduced by a
    particular implementation, i.e., as
    documented in the private enterprise MIB definition
    for the device.

    Setting this variable initiates the named test. Sets
    to this variable require the presence of
    upsTestSpinLock in the same SNMP message.

    The set request will be rejected with an appropriate
    error message if the requested test cannot be
    performed, including attempts to start a test when
    another test is already in progress. Tests in
    progress may be aborted by setting this variable to
    upsTestAbortTestInProgress.

    Read operations return the value of the name of the
    test in progress if a test is in progress or the name
    of the last test performed if no test is in progress,
    unless no test has bee run, in which case the well
    known value upsTestNoTestsInitiated is returned.

    Parsed from file tripplite_ups.mib.txt
    Company: None
    Module: TRIPPUPS1-MIB

    Description by circitor

    The test named by an OBJECT IDENTIFIER which
    allows a standard mechanism for the initiation of
    test, including the well known tests identified in
    this document as well as those introduced by a
    particular implementation, i.e., as
    documented in the private enterprise MIB definition
    for the device.

    Setting this variable initiates the named test. Sets
    to this variable require the presence of
    upsTestSpinLock in the same SNMP message.

    The set request will be rejected with an appropriate
    error message if the requested test cannot be
    performed, including attempts to start a test when
    another test is already in progress. Tests in
    progress may be aborted by setting this variable to
    upsTestAbortTestInProgress.

    Read operations return the value of the name of the
    test in progress if a test is in progress or the name
    of the last test performed if no test is in progress,
    unless no test has bee run, in which case the well
    known value upsTestNoTestsInitiated is returned.

    Parsed from file TRIPPUPS1-MIB.mib
    Module: TRIPPUPS1-MIB

    Information by oid_info

    Vendor: Tripp Lite
    Module: TRIPPUPS1-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    upsTestId OBJECT-TYPE SYNTAX INTEGER { noTestsInitiated(1), abortTestInProgress(2), generalSystemsTest(3), checkBatteryTest(4), deepBatteryCalibration(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The test named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of test, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. Tests in progress may be aborted by setting this variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has bee run, in which case the well known value upsTestNoTestsInitiated is returned." ::= { upsTest 1 }

    Information by circitor

    upsTestId OBJECT-TYPE SYNTAX INTEGER { noTestsInitiated(1), abortTestInProgress(2), generalSystemsTest(3), checkBatteryTest(4), deepBatteryCalibration(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The test named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of test, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. Tests in progress may be aborted by setting this variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has bee run, in which case the well known value upsTestNoTestsInitiated is returned." ::= { upsTest 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.850)

    Markle Lawren

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.850.1.1.8.1.0 upsTestId 0 0 None

    Brothers (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.850.1.1.8.2 upsTestResultsSummary 1 1 The results of the mandatory or last UPS diagnostics
    test performed. The values for donePass(1),
    doneWarning(2), and doneError(3…