Reference record for OID 1.3.6.1.4.1.855.2.4.1.3.3



parent
1.3.6.1.4.1.855.2.4.1.3 (upsControl)
node code
3
node name
upsControlUPSOffSignalHighDuration
dot oid
1.3.6.1.4.1.855.2.4.1.3.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsControl(3) upsControlUPSOffSignalHighDuration(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsControl(3) upsControlUPSOffSignalHighDuration(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsControl(3) upsControlUPSOffSignalHighDuration(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsControl(3) upsControlUPSOffSignalHighDuration(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsControl(3) upsControlUPSOffSignalHighDuration(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsControl(3) upsControlUPSOffSignalHighDuration(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/sec/powermon/powermonUPS4/ups/upsControl/upsControlUPSOffSignalHighDuration
  • /iso/identified-organization/dod/internet/private/enterprises/sec/powermon/powermonUPS4/ups/upsControl/upsControlUPSOffSignalHighDuration
  • /iso/org/dod/internet/private/enterprise/sec/powermon/powermonUPS4/ups/upsControl/upsControlUPSOffSignalHighDuration
  • /iso/org/dod/internet/private/enterprises/sec/powermon/powermonUPS4/ups/upsControl/upsControlUPSOffSignalHighDuration
  • /iso/iso-identified-organization/dod/internet/private/enterprise/sec/powermon/powermonUPS4/ups/upsControl/upsControlUPSOffSignalHighDuration
  • /iso/iso-identified-organization/dod/internet/private/enterprises/sec/powermon/powermonUPS4/ups/upsControl/upsControlUPSOffSignalHighDuration
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/855/2/4/1/3/3

    Description by mibdepot

    PowerMon Sends a series of pulses to the UPS to switch it off.
    These pulses are timed to take care of most of the Contact
    Closure UPS's. The pulse train is 750msec high, 1000msec low,
    2000msec high, 1000msec low, 6000msec high, then set to low.
    This object, together with upsControlUPSOffSignalLowDuration,
    enables the User to insert an extra pulse at the beginning of the
    pulse train.sent to the UPS to switch it Off. This object defines
    the duration (in milliseconds) of the High signal sent to the UPS.
    It is sent before upsControlUPSOffSignalLowDuration. Default is 0.

    Parsed from file POWERMN4.MIB.txt
    Company: cai
    Module: POWERMON4-MIB

    Information by oid_info

    Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.

    Information by mibdepot

    upsControlUPSOffSignalHighDuration OBJECT-TYPE SYNTAX INTEGER (0..30000) ACCESS read-write STATUS mandatory DESCRIPTION "PowerMon Sends a series of pulses to the UPS to switch it off. These pulses are timed to take care of most of the Contact Closure UPS's. The pulse train is 750msec high, 1000msec low, 2000msec high, 1000msec low, 6000msec high, then set to low. This object, together with upsControlUPSOffSignalLowDuration, enables the User to insert an extra pulse at the beginning of the pulse train.sent to the UPS to switch it Off. This object defines the duration (in milliseconds) of the High signal sent to the UPS. It is sent before upsControlUPSOffSignalLowDuration. Default is 0." ::= { upsControl 3 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.855)

    Held Steve

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.855.2.4.1.3.3.0 upsControlUPSOffSignalHighDuration 0 0 None

    Brothers (3)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.855.2.4.1.3.1 upsControlUPSOff 1 1 Setting this variable to turnUpsOff (2) causes the UPS to shut off.
    When in this state, the UPS will not provide output power re…
    1.3.6.1.4.1.855.2.4.1.3.2 upsControlUPSOffDelay 1 1 Number of seconds from demand for UPS Off until UPS goes Off .
    1.3.6.1.4.1.855.2.4.1.3.4 upsControlUPSOffSignalLowDuration 1 1 PowerMon Sends a series of pulses to the UPS to switch it off.
    These pulses are timed to take care of most of the Contact Closur…