The current state of a switch:
waiting - Waiting for a limited time on other
switches in the stack to come online.
progressing - Master election or mismatch checks in
progress.
added - The switch is added to the stack.
ready - The switch is operational.
sdmMismatch - The SDM template configured on the master
is not supported by the new member.
verMismatch - The operating system version running on the
master is different from the operating
system version running on this member.
featureMismatch - Some of the features configured on the
master are not supported on this member.
newMasterInit - Waiting for the new master to finish
initialization after master switchover
(Master Re-Init).
provisioned - The switch is not an active member of the
stack.
invalid - The switch's state machine is in an
invalid state.
removed - The switch is removed from the stack.
Parsed from file CISCO-STACKWISE-MIB.mib
Module: CISCO-STACKWISE-MIB
The current state of a switch:
waiting - Waiting for a limited time on other
switches in the stack to come online.
progressing - Master election or mismatch checks in
progress.
added - The switch is added to the stack.
ready - The switch is operational.
sdmMismatch - The SDM template configured on the master
is not supported by the new member.
verMismatch - The operating system version running on the
master is different from the operating
system version running on this member.
featureMismatch - Some of the features configured on the
master are not supported on this member.
newMasterInit - Waiting for the new master to finish
initialization after master switchover
(Master Re-Init).
provisioned - The switch is not an active member of the
stack.
invalid - The switch's state machine is in an
invalid state.
removed - The switch is removed from the stack.
The current state of a switch:
waiting - Waiting for a limited time on other
switches in the stack to come online.
progressing - Master election or mismatch checks in
progress.
added - The switch is added to the stack.
ready - The switch is operational.
sdmMismatch - The SDM template configured on the master
is not supported by the new member.
verMismatch - The operating system version running on the
master is different from the operating
system version running on this member.
featureMismatch - Some of the features configured on the
master are not supported on this member.
newMasterInit - Waiting for the new master to finish
initialization after master switchover
(Master Re-Init).
provisioned - The switch is not an active member of the
stack.
invalid - The switch's state machine is in an
invalid state.
removed - The switch is removed from the stack.
Parsed from file CISCO-STACKWISE-MIB.my.txt
Company: None
Module: CISCO-STACKWISE-MIB
The current state of a switch:
waiting - Waiting for a limited time on other
switches in the stack to come online.
progressing - Master election or mismatch checks in
progress.
added - The switch is added to the stack.
ready - The switch is operational.
sdmMismatch - The SDM template configured on the master
is not supported by the new member.
verMismatch - The operating system version running on the
master is different from the operating
system version running on this member.
featureMismatch - Some of the features configured on the
master are not supported on this member.
newMasterInit - Waiting for the new master to finish
initialization after master switchover
(Master Re-Init).
provisioned - The switch is not an active member of the
stack.
invalid - The switch's state machine is in an
invalid state.
removed - The switch is removed from the stack.
cswSwitchState OBJECT-TYPE SYNTAX INTEGER { waiting(1), progressing(2), added(3), ready(4), sdmMismatch(5), verMismatch(6), featureMismatch(7), newMasterInit(8), provisioned(9), invalid(10), removed(11) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of a switch: waiting - Waiting for a limited time on other switches in the stack to come online. progressing - Master election or mismatch checks in progress. added - The switch is added to the stack. ready - The switch is operational. sdmMismatch - The SDM template configured on the master is not supported by the new member. verMismatch - The operating system version running on the master is different from the operating system version running on this member. featureMismatch - Some of the features configured on the master are not supported on this member. newMasterInit - Waiting for the new master to finish initialization after master switchover (Master Re-Init). provisioned - The switch is not an active member of the stack. invalid - The switch's state machine is in an invalid state. removed - The switch is removed from the stack." ::= { cswSwitchInfoEntry 6 }
cswSwitchState OBJECT-TYPE SYNTAX INTEGER { waiting(1), progressing(2), added(3), ready(4), sdmMismatch(5), verMismatch(6), featureMismatch(7), newMasterInit(8), provisioned(9), invalid(10), removed(11) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of a switch: waiting - Waiting for a limited time on other switches in the stack to come online. progressing - Master election or mismatch checks in progress. added - The switch is added to the stack. ready - The switch is operational. sdmMismatch - The SDM template configured on the master is not supported by the new member. verMismatch - The operating system version running on the master is different from the operating system version running on this member. featureMismatch - Some of the features configured on the master are not supported on this member. newMasterInit - Waiting for the new master to finish initialization after master switchover (Master Re-Init). provisioned - The switch is not an active member of the stack. invalid - The switch's state machine is in an invalid state. removed - The switch is removed from the stack." ::= { cswSwitchInfoEntry 6 }
Vendor: Cisco
Module: CISCO-STACKWISE-MIB
[Automatically extracted from oidview.com]
cswSwitchState OBJECT-TYPE SYNTAX INTEGER { waiting(1), progressing(2), added(3), ready(4), sdmMismatch(5), verMismatch(6), featureMismatch(7), newMasterInit(8), provisioned(9), invalid(10), removed(11) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of a switch: waiting - Waiting for a limited time on other switches in the stack to come online. progressing - Master election or mismatch checks in progress. added - The switch is added to the stack. ready - The switch is operational. sdmMismatch - The SDM template configured on the master is not supported by the new member. verMismatch - The operating system version running on the master is different from the operating system version running on this member. featureMismatch - Some of the features configured on the master are not supported on this member. newMasterInit - Waiting for the new master to finish initialization after master switchover (Master Re-Init). provisioned - The switch is not an active member of the stack. invalid - The switch's state machine is in an invalid state. removed - The switch is removed from the stack." ::= { cswSwitchInfoEntry 6 }
cswSwitchState OBJECT-TYPE SYNTAX INTEGER { waiting(1), progressing(2), added(3), ready(4), sdmMismatch(5), verMismatch(6), featureMismatch(7), newMasterInit(8), provisioned(9), invalid(10), removed(11) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of a switch: waiting - Waiting for a limited time on other switches in the stack to come online. progressing - Master election or mismatch checks in progress. added - The switch is added to the stack. ready - The switch is operational. sdmMismatch - The SDM template configured on the master is not supported by the new member. verMismatch - The operating system version running on the master is different from the operating system version running on this member. featureMismatch - Some of the features configured on the master are not supported on this member. newMasterInit - Waiting for the new master to finish initialization after master switchover (Master Re-Init). provisioned - The switch is not an active member of the stack. invalid - The switch's state machine is in an invalid state. removed - The switch is removed from the stack." ::= { cswSwitchInfoEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.9.500.1.2.1.1.1 | cswSwitchNumCurrent | 0 | 0 | This object contains the current switch identification number. This number should match any logical labeling on the switch. For e… |
1.3.6.1.4.1.9.9.500.1.2.1.1.2 | cswSwitchNumNextReload | 0 | 0 | This object contains the cswSwitchNumCurrent to be used at next reload. The maximum value for this object is defined by the cswM… |
1.3.6.1.4.1.9.9.500.1.2.1.1.3 | cswSwitchRole | 0 | 0 | This object describes the function of the switch: master - stack master. member - active member of the stack. notMember - no… |
1.3.6.1.4.1.9.9.500.1.2.1.1.4 | cswSwitchSwPriority | 0 | 0 | A number containing the priority of a switch. The switch with the highest priority will become the master. The maximum value fo… |
1.3.6.1.4.1.9.9.500.1.2.1.1.5 | cswSwitchHwPriority | 0 | 0 | This object contains the hardware priority of a switch. If two or more entries in this table have the same cswSwitchSwPriority v… |
1.3.6.1.4.1.9.9.500.1.2.1.1.7 | cswSwitchMacAddress | 0 | 0 | The MAC address of the switch. Note: This object will contain the value of 0000:0000:0000 if the cswSwitchState value is other th… |
1.3.6.1.4.1.9.9.500.1.2.1.1.8 | cswSwitchSoftwareImage | 0 | 0 | The software image type running on the switch. Note: This object will contain an empty string if the cswSwitchState value is othe… |
1.3.6.1.4.1.9.9.500.1.2.1.1.9 | cswSwitchPowerBudget | 0 | 0 | This object indicates the power budget of the switch. |
1.3.6.1.4.1.9.9.500.1.2.1.1.10 | cswSwitchPowerCommited | 0 | 0 | This object indicates the power committed to the POE devices connected to the switch. |
1.3.6.1.4.1.9.9.500.1.2.1.1.11 | cswSwitchSystemPowerPriority | 0 | 0 | This specifies the system's power priority. In case of a power failure then the system with the highest system priority will be b… |
1.3.6.1.4.1.9.9.500.1.2.1.1.12 | cswSwitchPoeDevicesLowPriority | 0 | 0 | This object specifies the priority of the system's low priority POE devices. |
1.3.6.1.4.1.9.9.500.1.2.1.1.13 | cswSwitchPoeDevicesHighPriority | 0 | 0 | This object specifies the priority of the system's high priority POE devices. In order to avoid losing the high priority POE devi… |
1.3.6.1.4.1.9.9.500.1.2.1.1.14 | cswSwitchPowerAllocated | 0 | 0 | This object indicates the power committed to the POE devices connected to the switch. |