-- Version 2.15.1.5, modified 2002-02-22 13:18:15-05 CDX-6500-COMMON-MIB DEFINITIONS ::= BEGIN IMPORTS mgmt, NetworkAddress, IpAddress, Counter, Gauge, TimeTicks, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Codex MIB Group definitions codex OBJECT IDENTIFIER ::= { enterprises 449 } cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 } cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 } cdx6500NodeMgmt OBJECT IDENTIFIER ::= { cdx6500 1 } cdx6500NMSNMPGroup OBJECT IDENTIFIER ::= { cdx6500NodeMgmt 1 } cdx6500NMNodeParametersGroup OBJECT IDENTIFIER ::= { cdx6500NodeMgmt 2 } cdx6500NMDiagnosticsGroup OBJECT IDENTIFIER ::= { cdx6500NodeMgmt 3 } cdx6500NMControlsGroup OBJECT IDENTIFIER ::= { cdx6500NodeMgmt 4 } cdx6500NMDLSVGroup OBJECT IDENTIFIER ::= { cdx6500NodeMgmt 5 } cdx6500Configuration OBJECT IDENTIFIER ::= { cdx6500 2 } cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 } cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 } cdx6500CfgGeneralGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 2 } cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 } cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 } cdx6500StatOtherStatsGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 2 } cdx6500StatTFTPGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 3 } cdx6500StatNetworkSvcsGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 4 } cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 } cdx6500PSTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 3 } cdx6500PSTLANConnectionGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 6 } cdx6500Controls OBJECT IDENTIFIER ::= { cdx6500 4 } cdx6500ContTFTP OBJECT IDENTIFIER ::= { cdx6500Controls 2 } cdx6500statControls OBJECT IDENTIFIER ::= { cdx6500Controls 4 } cdx6500ContFlash OBJECT IDENTIFIER ::= { cdx6500Controls 21 } -- Textual conventions Counter16 ::= INTEGER (0..65535) DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having SIZE (0..255) -- The purpose of this MIB file is to provide SNMP access to -- the Motorola/Codex 6500 database -- the SNMP Agent group -- This group acts as an extension of the MIB-II snmp group. It -- describes managed objects used by the Pegasus SNMP agent that -- are not included in the snmp group. cdx6500SNMPPrimUDPChan OBJECT-TYPE SYNTAX DisplayString (SIZE(0..3)) ACCESS read-write STATUS mandatory DESCRIPTION "The primary UDP port used by the SNMP Agent has a default value of 161." ::= { cdx6500NMSNMPGroup 1 } cdx6500SNMPSecUDPChan OBJECT-TYPE SYNTAX DisplayString (SIZE(0..3)) ACCESS read-write STATUS mandatory DESCRIPTION "The secondary UDP port used by the SNMP Agent has a default value of 162." ::= { cdx6500NMSNMPGroup 2 } cdx6500SNMPAgentTimer OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "An internal timer used by the SNMP agent, unit is a 20 ms tick." ::= { cdx6500NMSNMPGroup 3 } cdx6500SNMPTrapEnable OBJECT-TYPE SYNTAX INTEGER { disable (0), enable (1), newvalDisable (50) } ACCESS read-write STATUS mandatory DESCRIPTION "A control object to disable or enable the SNMP agent's trap send capability. newvalDisable : same functionality as 'disable', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMSNMPGroup 4 } cdx6500SNMPBootAgent OBJECT-TYPE SYNTAX INTEGER { boot (1), noBoot (2) } ACCESS write-only STATUS mandatory DESCRIPTION "A control object. Setting to value `boot' will cause the SNMP agent to boot." ::= { cdx6500NMSNMPGroup 5 } cdx6500SNMPResetStats OBJECT-TYPE SYNTAX INTEGER { reset (1), noReset (2) } ACCESS write-only STATUS mandatory DESCRIPTION "A control object, which when set to value `reset', will cause the SNMP agent to reset all its statistics." ::= { cdx6500NMSNMPGroup 6 } cdx6500SNMPLastTrap OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "The interesting information portion of the last trap PDU issued by the SNMP Agent." ::= { cdx6500NMSNMPGroup 7 } cdx6500SNMPGenTrapsType OBJECT-TYPE SYNTAX INTEGER { rfc (1), enterpriseSpecific (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Choice between generic traps as defined in RFC or correponding enterprise specific traps to be generated by the node. This attribute is applicable only when generic traps are being generated and there exists a corresponding enterprise specific trap." ::= { cdx6500NMSNMPGroup 8 } cdx6500SNMPTrapThrottleTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SNMPTrapThrottleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Throttling table." ::= { cdx6500NMSNMPGroup 9 } cdx6500SNMPTrapThrottleEntry OBJECT-TYPE SYNTAX Cdx6500SNMPTrapThrottleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry representing throttling parameters." INDEX {cdx6500SNMPTrapNumber} ::= { cdx6500SNMPTrapThrottleTable 1 } Cdx6500SNMPTrapThrottleEntry ::= SEQUENCE { cdx6500SNMPTrapNumber INTEGER, cdx6500SNMPMaxNumOfTraps INTEGER, cdx6500SNMPThrottlingPeriod INTEGER, cdx6500SNMPNewTrapLevel INTEGER, cdx6500SNMPEntryStatus INTEGER } cdx6500SNMPTrapNumber OBJECT-TYPE SYNTAX INTEGER(1000..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Trap number to be throttled." ::= { cdx6500SNMPTrapThrottleEntry 1 } cdx6500SNMPMaxNumOfTraps OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Number of traps allowed to be generated in the throttling period." DEFVAL {5} ::= { cdx6500SNMPTrapThrottleEntry 2 } cdx6500SNMPThrottlingPeriod OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Throttling time period in seconds. Value 0 means trap is not throttled." DEFVAL {60} ::= { cdx6500SNMPTrapThrottleEntry 3 } cdx6500SNMPNewTrapLevel OBJECT-TYPE SYNTAX INTEGER {unchanged(1), high (2), medium(3), low(5)} ACCESS read-write STATUS mandatory DESCRIPTION "New severity level for the trap." DEFVAL {unchanged} ::= { cdx6500SNMPTrapThrottleEntry 4 } cdx6500SNMPEntryStatus OBJECT-TYPE SYNTAX INTEGER {active(1), deleted(2)} ACCESS read-write STATUS mandatory DESCRIPTION "Table row status. Setting the value to deleted removes the entry from the table." DEFVAL {active} ::= { cdx6500SNMPTrapThrottleEntry 5 } cdx6500SNMPSetControl OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Snmp Set operation control off : snmp set operation is not allowed on : snmp set operation is allowed." ::= { cdx6500NMSNMPGroup 10 } cdx6500SNMPIpAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "IP address for this node." ::= { cdx6500NMSNMPGroup 11 } -- The Node Parameters Group -- contains configuration, inventory, and statistics -- on a node-wide basis. cdx6500NMNPconfig OBJECT IDENTIFIER ::= { cdx6500NMNodeParametersGroup 1 } cdx6500NMNPinvent OBJECT IDENTIFIER ::= { cdx6500NMNodeParametersGroup 2 } cdx6500NMNPstats OBJECT IDENTIFIER ::= { cdx6500NMNodeParametersGroup 3 } -- Node Management Configuration Group cdx6500NMNPCnodeName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter identifies the node with a name, which appears at the top of control terminal menus and reports. Range is 0 to 8 alphanumeric characters." ::= { cdx6500NMNPconfig 1 } cdx6500NMNPCnodeNum OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The node number identifies the node for X.25 routing purposes to prevent routing loops." ::= { cdx6500NMNPconfig 2 } cdx6500NMNPCnodeAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..13)) ACCESS read-only STATUS mandatory DESCRIPTION "The node address specifies the main part of the network address for calls destined within this node: PAD port or node resource (for example, control port) calls. Individual subaddresses specify exact destination." ::= { cdx6500NMNPconfig 3 } cdx6500NMNPCchassis OBJECT-TYPE SYNTAX INTEGER { standalone (0), modulus8 (1), modulus18 (2), modulus9 (3), modulus19 (4), chassis6520 (5), chassis6560 (6), newvalStandalone (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameters identifies the type of chassis that this node is residing in. This is necessary in order to correctly interpret the fan and power supply status signals. newvalStandalone : same functionality as 'standalone', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMNPconfig 4 } cdx6500NMNPCdate OBJECT-TYPE SYNTAX DisplayString (SIZE(9)) ACCESS read-only STATUS mandatory DESCRIPTION "The node date used for date stamps of events and traps. The format of the string is yyyymmmdd, year: four digits, month: first three letters of the month, day: 01..31." ::= { cdx6500NMNPconfig 5 } cdx6500NMNPCtime OBJECT-TYPE SYNTAX DisplayString (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The node time used for time stamps of events and traps. The format of the string is hhmmss, hour: 00..23, minute 00..59, second: 00..59." ::= { cdx6500NMNPconfig 6 } cdx6500NMNPCportUtil OBJECT-TYPE SYNTAX INTEGER (10..99) ACCESS read-only STATUS mandatory DESCRIPTION "Port Utilization Threshold (%). This parameter sets the alarm level for traffic on every port in a node. The traffic is checked over a 64-second interval to give an average (in characters per second). This is compared to the port's clock rate and a utilization factor is produced. If the percent of utiliaztion exceeds the setting, an alarm is generated. Port utilization records are kept for each port and the port in question is noted in the report." ::= { cdx6500NMNPconfig 7 } cdx6500NMNPCbuffUtil OBJECT-TYPE SYNTAX INTEGER (10..99) ACCESS read-only STATUS mandatory DESCRIPTION "Buffer Utilization Threshold (%). This parameter sets the alarm level for data buffers. When data passes through a node, buffers provide temporary storage. If the number of buffers used exceeds the specified percentage of available storage, an alarm is generated." ::= { cdx6500NMNPconfig 8 } cdx6500NMNPCcpuUtil OBJECT-TYPE SYNTAX INTEGER (10..99) ACCESS read-only STATUS mandatory DESCRIPTION "CPU Utilization Threshold (%). If the CPU is not processing data, it is running diagnostic checks. It is never idle. This parameter specifies the amount of time spent performing non-diagnostic functions as a percentage of the total time. If this percentage exceeds the threshold, an alarm is generated." ::= { cdx6500NMNPconfig 9 } cdx6500NMNPCportErr OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Port Error Threshold. This threshold specifies the number of port errors (such as parity or framing errors) that can be detected before a medium severity alarm is generated. For example, if this parameter is set to 10, an alarm is sent when 10 errors are detected, another alarm is sent when the 20th error is detected, etc." ::= { cdx6500NMNPconfig 10 } cdx6500NMNPCalarmTmr OBJECT-TYPE SYNTAX INTEGER (15..255) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Threshold Timer. This parameter prevents a node from sending threshold alarms too frequently. If a node generates an alarm the threshold alarm timer is started and the node is not allowed to generate the same alarm until the timer has expired. This controls the frequency of alarm reporting." ::= { cdx6500NMNPconfig 11 } cdx6500NMNPCmaxRoutHops OBJECT-TYPE SYNTAX INTEGER (2..15) ACCESS read-only STATUS mandatory DESCRIPTION "Maximum Routing Hops.This parameter specifies the maximum number of nodes a call may pass through before reaching its destination." ::= { cdx6500NMNPconfig 12 } cdx6500NMNPCctpSubAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..3)) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the Control Port (CTP) Subaddress. Calls with network address composed of the node address and this subaddress will be routed to the control port in this node. No routing table entry is needed." ::= { cdx6500NMNPconfig 13 } cdx6500NMNPCctpIdleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Control Port Idle Disconnect Time (minutes). This specifies how many minutes of inactivity can occur before the control terminal is automatically disconnected" ::= { cdx6500NMNPconfig 14 } cdx6500NMNPCalmDist OBJECT-TYPE SYNTAX INTEGER { deprecatedObj (1) } ACCESS read-only STATUS deprecated DESCRIPTION "This object has been replaced by cdx6500NMNPCalmDistrib." ::= { cdx6500NMNPconfig 15 } cdx6500NMNPCalmMmem OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Printer Mnemonic. This specifies the mnemonic name for the destination of alarms sent by the node (if Alarm Distribution = PRIN). This destination is usually a printer or a personal computer. To prevent any alarms from being sent, set this to blank." ::= { cdx6500NMNPconfig 16 } cdx6500NMNPCalmSelect OBJECT-TYPE SYNTAX INTEGER { deprecatedObj (1) } ACCESS read-only STATUS deprecated DESCRIPTION "This object has been replaced by cdx6500NMNPCalmSelection." ::= { cdx6500NMNPconfig 17 } cdx6500NMNPCbroadPortSubad OBJECT-TYPE SYNTAX DisplayString (SIZE (0..3)) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the broadcast port subaddress for this node. Calls with network address composed of the node address and this subaddress will be routed to the broadcast port in this node. No routing table entry is needed." ::= { cdx6500NMNPconfig 18 } cdx6500NMNPCnoBroadNets OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Number of Broadcast Nets. This specifies the number of Broadcast Networks to which this node can send broadcast messages. A value of 0 will disable broadcast functions." ::= { cdx6500NMNPconfig 19 } cdx6500NMNPCnoBroadInCh OBJECT-TYPE SYNTAX INTEGER (0..10) ACCESS read-only STATUS mandatory DESCRIPTION "Number of Broadcast Input Channels. This specifies the number of simultaneous broadcast messages that can be received." ::= { cdx6500NMNPconfig 20 } cdx6500NMNPCbillMnem OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "When billing records need to be printed, the node will use this mnemonic to call and send the records to this destination. This location is usually a printer used to print billing records." ::= { cdx6500NMNPconfig 21 } cdx6500NMNPCbillThresh OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "When the number of billing records queued up equals this threshold, a call will be placed to the logging device to dump the billing records." ::= { cdx6500NMNPconfig 22 } cdx6500NMNPCmaxBill OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "This is the maximum number of billing records the node will be allowed to store to be printed. Billing records created after this maximum is reached will be lost." ::= { cdx6500NMNPconfig 23 } cdx6500NMNPCbillTimer OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "If billing records have been stored for printing for this amount of time (in minutes) without reaching the threshold, a call will be made so that they can be printed." ::= { cdx6500NMNPconfig 24 } cdx6500NMNPCpvcBill OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "At this interval the billing records will be gathered and printed for all of the PVC's in the node that have billing turned on." ::= { cdx6500NMNPconfig 25 } cdx6500NMNPCmaxCalls OBJECT-TYPE SYNTAX INTEGER (1..2000) ACCESS read-only STATUS mandatory DESCRIPTION "Limiting the number of calls allowed in the node will eliminate data loss in extreme traffic conditions." ::= { cdx6500NMNPconfig 26 } cdx6500NMNPCpadBulletin OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "PAD Bulletin Message. Specifies the message that appears when a terminal connects to PAD port and enters Command Mode. To have no message appear, select blank." ::= { cdx6500NMNPconfig 27 } cdx6500NMNPCpadBanner OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "PAD Banner Message. Specifies the message PAD ports send to attached terminals when they enter Command Mode. These special characters can be used to display certain information in the PAD Banner Message. A Node address C Channel Number G Group sub-address N Node Name P Port Number S Sub-address T Time V Software revision If the character following the % symbol is not one of the above, both the % and following character are discarded. The caret (^) is used as an escape character to tell the PAD to send control characters. The character following the caret is converted to a control character and is sent to the PAD port for output. The caret is discarded unless it is entered twice (^^)." ::= { cdx6500NMNPconfig 28 } cdx6500NMNPCdcpFac OBJECT-TYPE SYNTAX INTEGER (201..254) ACCESS read-only STATUS mandatory DESCRIPTION "This defines the facility used to carry DCP information at call setup and reconnection time in Call Request and Call Accept packets through the 6500 network. Change the value only if it interferes with some other private network facility." ::= { cdx6500NMNPconfig 29 } cdx6500NMNPCtrafficPri OBJECT-TYPE SYNTAX INTEGER { low (0), med (1), high (2), exp (3), newvalLow (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Traffic Priority. This is the default traffic priority to be used on the node. newvalLow : same functionality as 'low', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMNPconfig 30 } cdx6500NMNPCtrafficStep OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Traffic Priority Step. This specifies the number of packets to be transmitted for each lower priority packet transmitted." ::= { cdx6500NMNPconfig 31 } cdx6500NMNPCpropProtId OBJECT-TYPE SYNTAX INTEGER (192..255) ACCESS read-only STATUS mandatory DESCRIPTION "This is the Codex Proprietary Protocol ID. Its value is put in the first byte of the Protocol Identifier field of the CUD in the Call Request packets for protocols that have not been assigned a standardized value by the CCITT." ::= { cdx6500NMNPconfig 32 } cdx6500NMNPClanSubAddr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..3)) ACCESS read-only STATUS mandatory DESCRIPTION "Calls with network address composed of the node address and this subaddress will be routed to a LAN Connection in this node." ::= { cdx6500NMNPconfig 33 } cdx6500NMNPCMaxFrameSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The largest datalink level frame that will ever be received on any link. On WAN links this does not include space that is reserved internally for trailers." ::= { cdx6500NMNPconfig 34 } cdx6500NMNPCCodexGroupFacility OBJECT-TYPE SYNTAX INTEGER (202..254) ACCESS read-only STATUS mandatory DESCRIPTION "This is the facility used in call packets on Codex 6500 links for passing CODEX PRIVATE facilities other than Hop Count and DCP facilities between 4.xx nodes. This should be the SAME on all nodes in the network. It need only be changed if it interferes with some other private network facility." -- DEFVAL { 202 } ::= { cdx6500NMNPconfig 35 } cdx6500NMNPCalmDistrib OBJECT-TYPE SYNTAX DisplayString (SIZE(3..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Distribution of alarms is controlled by specifying: NONE - no alarm is sent\r\n\ CTP - send alarms to Control Port Terminal\r\n\ PRIN - send alarms to Printer Destination\r\n\ Any combination of above specified by summing (e.g. CTP+PRIN)." ::= { cdx6500NMNPconfig 36 } cdx6500NMNPCalmSelection OBJECT-TYPE SYNTAX DisplayString (SIZE(3..27)) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm type reporting by the node: NONE - no alarms reported. HIGH - high severity alarms reported. MED - medium severity alarms reported. LOW - low severity alarms reported. CONN - connection events reported. CODE - alarms from Codex 6000 communication processors reported. Any combination of above specified by summing (e.g. HIGH+CONN+. . .)." ::= { cdx6500NMNPconfig 37 } cdx6500NMNPChopFacility OBJECT-TYPE SYNTAX INTEGER (200..254) ACCESS read-only STATUS mandatory DESCRIPTION "Hop Count Facility. This is the facility used in call packets on X.25 links with the INL option for network routing. This should be the SAME in all nodes in the network. It need only be changed if it interferes with some other private network facility." ::= { cdx6500NMNPconfig 38 } cdx6500NMNPCnumNccpDevices OBJECT-TYPE SYNTAX INTEGER (1..2000) ACCESS read-only STATUS mandatory DESCRIPTION "This is the number of NCCP devices." ::= { cdx6500NMNPconfig 39 } cdx6500NMNPCmaxCallid OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "This is the maximum number of Call id numbers that go in the Calling Identifier table. This table can have a maximum of 512 entries. Each entry of 30 digits." ::= { cdx6500NMNPconfig 40 } -- Node Inventory Group cdx6500NMNPIproductType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Identifies a general class of feature set for the product, e.g. 6504PLUS Asynchronous PAD or 6520 Branch Node" ::= { cdx6500NMNPinvent 1 } cdx6500NMNPIsoftwareSrc OBJECT-TYPE SYNTAX INTEGER { prom (0), download (1), promLoadingRAM (2), newvalProm (50) } ACCESS read-only STATUS mandatory DESCRIPTION "The source of software currently running on the node. prom - CPU running from code in PROM. download - CPU downloading code into RAM. promLoadingRAM - CPU running from code in RAM. newvalProm - same functionality as 'prom', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMNPinvent 2 } cdx6500NMNPIserialNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of the motherboard." ::= { cdx6500NMNPinvent 3 } cdx6500NMNPIpromRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The PROM software revision." ::= { cdx6500NMNPinvent 4 } cdx6500NMNPIdlCodeRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "The downloaded software revision. Applicable to 6500 platforms." ::= { cdx6500NMNPinvent 5 } cdx6500NMNPIdlCodeSource OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "The source of downloaded software. Applicable to 6500 platforms." ::= { cdx6500NMNPinvent 6 } cdx6500NMNPIdlCodeSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The size of downloaded software in bytes. Applicable to 6500 platforms." ::= { cdx6500NMNPinvent 7 } cdx6500NMNPIflashStatus OBJECT-TYPE SYNTAX INTEGER { enabled (0), disabled (1), newvalEnabled (50) } ACCESS read-only STATUS optional DESCRIPTION "The status of use of flash memory. Applicable only to 6500 platforms. newvalEnabled : same functionality as 'enabled', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMNPinvent 8 } cdx6500NMNPIflashIdCur OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Name and version of software stored in flash. This refers to the currently selected bank of flash when there is an alternate bank of flash installed." ::= { cdx6500NMNPinvent 9 } cdx6500NMNPIflashIdAlt OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Name and version of software contained by the alternate bank of flash (if installed). Applicable to 6520 platforms." ::= { cdx6500NMNPinvent 10 } cdx6500NMNPIflashSizeCur OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size of software stored in flash. This refers to the currently selected bank of flash when there is an alternate bank of flash installed." ::= { cdx6500NMNPinvent 11 } cdx6500NMNPIflashSizeAlt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Size of software in the alternate bank of flash (bytes). Applicable to 6520 platforms." ::= { cdx6500NMNPinvent 12 } cdx6500NMNPIinventTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500NMNPIinventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of the node's boards." ::= { cdx6500NMNPinvent 13 } cdx6500NMNPIinventEntry OBJECT-TYPE SYNTAX Cdx6500NMNPIinventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains a board number, board type, number of ports, status, and serial number." INDEX { cdx6500NMNPIinventBoard } ::= { cdx6500NMNPIinventTable 1} Cdx6500NMNPIinventEntry ::= SEQUENCE { cdx6500NMNPIinventBoard INTEGER, cdx6500NMNPIinventType DisplayString, cdx6500NMNPIinventPorts INTEGER, cdx6500NMNPIinventStatus DisplayString, cdx6500NMNPIinventSerial DisplayString, cdx6500NMNPIinventAssy DisplayString, cdx6500NMNPIinventRev DisplayString, cdx6500NMNPIinventDIM1 DisplayString, cdx6500NMNPIinventDIM2 DisplayString } cdx6500NMNPIinventBoard OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The board number. This is used to index the boards in a node." ::= { cdx6500NMNPIinventEntry 1 } cdx6500NMNPIinventType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The board type. A description of the type of board." ::= { cdx6500NMNPIinventEntry 2 } cdx6500NMNPIinventPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of I/O ports for this board." ::= { cdx6500NMNPIinventEntry 3 } cdx6500NMNPIinventStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The status of the board" ::= { cdx6500NMNPIinventEntry 4 } cdx6500NMNPIinventSerial OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of the board" ::= { cdx6500NMNPIinventEntry 5 } cdx6500NMNPIinventAssy OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The assembly number of the board" ::= { cdx6500NMNPIinventEntry 6 } cdx6500NMNPIinventRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The revision level of the board" ::= { cdx6500NMNPIinventEntry 7 } cdx6500NMNPIinventDIM1 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface specified by DIM 1." ::= { cdx6500NMNPIinventEntry 8 } cdx6500NMNPIinventDIM2 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface specified by DIM 2." ::= { cdx6500NMNPIinventEntry 9 } cdx6500NMNPIinventPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500NMNPIinventPortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of the node's Port Configuration." ::= { cdx6500NMNPinvent 14 } cdx6500NMNPIinventPortConfigEntry OBJECT-TYPE SYNTAX Cdx6500NMNPIinventPortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains a port configuration." INDEX { cdx6500NMNPIinventPortNum } ::= { cdx6500NMNPIinventPortConfigTable 1} Cdx6500NMNPIinventPortConfigEntry ::= SEQUENCE { cdx6500NMNPIinventPortNum INTEGER, cdx6500NMNPIinventPortConfig DisplayString } cdx6500NMNPIinventPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number. This is used to index the ports in a node." ::= { cdx6500NMNPIinventPortConfigEntry 1 } cdx6500NMNPIinventPortConfig OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The port configuration on each board." ::= { cdx6500NMNPIinventPortConfigEntry 2 } -- Node Management Statistics Group cdx6500NMNPSevLastOccPower OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The last time the node was turned on." ::= { cdx6500NMNPstats 1 } cdx6500NMNPSevLastOccReset OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The last time the reset button was pressed." ::= { cdx6500NMNPstats 2 } cdx6500NMNPSevLastOccReboot OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The last time the node was rebooted." ::= { cdx6500NMNPstats 3 } cdx6500NMNPSevLastOccWDTimer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The last time the watch dog timer expired." ::= { cdx6500NMNPstats 4 } cdx6500NMNPSevLastOccConfig OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The last time the configuration memory was changed or downloaded." ::= { cdx6500NMNPstats 5 } cdx6500NMNPSstatusFan OBJECT-TYPE SYNTAX INTEGER { notMonitored (0), operational (1), impaired (2), newvalNotMonitored (50) } ACCESS read-only STATUS mandatory DESCRIPTION "The operational status of the cooling fan. newvalNotMonitored : same functionality as 'notMonitored', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMNPstats 6 } cdx6500NMNPSstatusPwrSy OBJECT-TYPE SYNTAX INTEGER { notMonitored (0), operational (1), impaired (2), newvalNotMonitored (50), notAvailable (100) } ACCESS read-only STATUS deprecated DESCRIPTION "The operational status of the power supply. This object is being replaced by cdx6500NMNPSstatusPowerSy. newvalNotMonitored : same functionality as 'notMonitored', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMNPstats 7 } cdx6500NMNPScmemSizeComp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size of compressed configuration memory available (free) in bytes." ::= { cdx6500NMNPstats 8 } cdx6500NMNPScmemUseComp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size of compressed configuration memory in use in bytes." ::= { cdx6500NMNPstats 9 } cdx6500NMNPScmemSizeUncomp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size of uncompressed configuration memory available (free) in bytes." ::= { cdx6500NMNPstats 10 } cdx6500NMNPScmemUseUnComp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size of uncompressed configuration memory in use in bytes." ::= { cdx6500NMNPstats 11 } cdx6500NMNPScallsInPlaceCur OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of X.25 calls. The number of calls currently in place." ::= { cdx6500NMNPstats 12 } cdx6500NMNPScallsInPlaceMax OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Number of X.25 calls gauge. The maximum number of calls since the last reset." ::= { cdx6500NMNPstats 13 } cdx6500NMNPScallsPerSecCur OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Rate of X.25 calls. The number of calls/sec. currently in place." ::= { cdx6500NMNPstats 14 } cdx6500NMNPScallsPerSecMax OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Rate of X.25 calls gauge. The maximum number of calls/sec. since the last reset." ::= { cdx6500NMNPstats 15 } cdx6500NMNPSpvcConnectCur OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Permanent virtual circuit connections. The number currently in place." ::= { cdx6500NMNPstats 16 } cdx6500NMNPSPVCConnectMax OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Permanent virtual circuit connections. The maximum since the last reset." ::= { cdx6500NMNPstats 17 } cdx6500NMNPSbuffDataAvail OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The number of data buffers available. Applicable to all platforms." ::= { cdx6500NMNPstats 18 } cdx6500NMNPSbuffDataUse OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The number of data buffers in use. Applicable to all platforms." ::= { cdx6500NMNPstats 19 } cdx6500NMNPSbuffDataGauge OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS optional DESCRIPTION "The maximum number of data buffers in use since last reset Applicable to all platforms." ::= { cdx6500NMNPstats 20 } cdx6500NMNPSbuffPacketAvail OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The number of packet buffers available. Applicable to all platforms except VG100 ." ::= { cdx6500NMNPstats 21 } cdx6500NMNPSbuffPacketUse OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The number of packet buffers in use. Applicable to all platforms except VG100." ::= { cdx6500NMNPstats 22 } cdx6500NMNPSbuffPacketExhaust OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS optional DESCRIPTION "The number of times the packet buffer pool has been exhausted since last reset. Applicable to all platforms except VG100." ::= { cdx6500NMNPstats 23 } cdx6500NMNPSbuffMgtAvail OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The number of management buffers available. Applicable to all platforms except VG100." ::= { cdx6500NMNPstats 24 } cdx6500NMNPSbuffMgtUse OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The number of management buffers in use. Applicable to all platforms except VG100." ::= { cdx6500NMNPstats 25 } cdx6500NMNPSbuffMgtExhaust OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS optional DESCRIPTION "The number of times the management buffer pool has been exhausted since last reset. Applicable to all platforms except VG100." ::= { cdx6500NMNPstats 26 } cdx6500NMNPSrateCurChar OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Node throughput, number of current chararacters/second for the node." ::= { cdx6500NMNPstats 27 } cdx6500NMNPSrateCurPkt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Node throughput, number of current packets/second for the node." ::= { cdx6500NMNPstats 28 } cdx6500NMNPSrateMaxChar OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Node throughput gauge, Number of maximum characters/second for the node since last reset" ::= { cdx6500NMNPstats 29 } cdx6500NMNPSrateMaxPkt OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Node throughput gauge, Number of maximum packets/second for the node since last reset" ::= { cdx6500NMNPstats 30 } cdx6500NMNPSmemEprom OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Amount of memory available on the processor card in bytes. Applicable to 6520 platforms." ::= { cdx6500NMNPstats 31 } cdx6500NMNPSmemDram OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Amount of memory used for data buffers in bytes. Applicable to 6520 platforms." ::= { cdx6500NMNPstats 32 } cdx6500NMNPSmemFlashCur OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The size of the flash module in bytes. This refers to the currently selected bank of flash when there is an alternate bank of flash installed. Applicable to 6520 platforms." ::= { cdx6500NMNPstats 33 } cdx6500NMNPSmemFlashAlt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The size of the alternate flash module in bytes. Applicable to 6520 platforms." ::= { cdx6500NMNPstats 34 } cdx6500NMNPScpuUtil OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Percentage of time the CPU processed traffic data (as opposed performing diagnositic tests or processing node control data) to in the last 64 seconds. Applicable to 6520 platforms." ::= { cdx6500NMNPstats 35 } cdx6500NMNPSDisplayNumImage OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Front panel numeric display. Applicable to 6520 platforms." ::= { cdx6500NMNPstats 36 } cdx6500NMNPSDisplayLEDstatus OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), blinking (2), newvalOff (50), notSupported (100) } ACCESS read-only STATUS optional DESCRIPTION "Front panel status LED. Applicable to 6520 platforms. newvalOff : same functionality as 'off', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMNPstats 37 } cdx6500NMNPSDisplayLEDdiag OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), blinking (2), newvalOff (50), notSupported (100) } ACCESS read-only STATUS optional DESCRIPTION "Front panel fault (or service) LED. Applicable to 6520 platforms. newvalOff : same functionality as 'off', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMNPstats 38 } cdx6500NMNPSdefaultNode OBJECT-TYPE SYNTAX INTEGER { default (1), noDefault (2) } ACCESS not-accessible STATUS mandatory DESCRIPTION "A control object. Setting to value default will cause the current configuration of the entire node to change back to the default settings. CAUTION: If you implement the Default Node control, communications are disrupted and data could be lost after a boot. In addition, configuration settings are lost unless they had been saved to an external device." ::= { cdx6500NMNPstats 39 } cdx6500NMNPSresetStatTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500NMNPSresetStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Port Statistic Reset entries." ::= { cdx6500NMNPstats 40 } cdx6500NMNPSresetStatAll OBJECT-TYPE SYNTAX INTEGER { reset (1), noReset (2) } ACCESS write-only STATUS mandatory DESCRIPTION "A value of reset will cause statistics to be reset on all ports. A value of noReset has no effect." ::= { cdx6500NMNPstats 41 } cdx6500NMNPSstatusPowerSy OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "The operational status of the power supply. This object replaces cdx6500NMNPSstatusPwrSy." ::= { cdx6500NMNPstats 42 } cdx6500NMNPSresetStatEntry OBJECT-TYPE SYNTAX Cdx6500NMNPSresetStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains a port number and a control to reset statistics for that port." INDEX { cdx6500NMNPSresetStatPort } ::= { cdx6500NMNPSresetStatTable 1 } Cdx6500NMNPSresetStatEntry ::= SEQUENCE { cdx6500NMNPSresetStatPort INTEGER, cdx6500NMNPSresetStatStatus INTEGER } cdx6500NMNPSresetStatPort OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS not-accessible STATUS mandatory DESCRIPTION "The port number value for this object directs the statistics reset command to that port." ::= { cdx6500NMNPSresetStatEntry 1 } cdx6500NMNPSresetStatStatus OBJECT-TYPE SYNTAX INTEGER { reset (1), noReset (2) } ACCESS write-only STATUS mandatory DESCRIPTION "A value of reset will cause a port's statistics to be reset. A value of noReset has no effect." ::= { cdx6500NMNPSresetStatEntry 2 } cdx6500NMNPSstatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500NMNPSstatsEntry ACCESS not-accessible STATUS optional DESCRIPTION "Board specific statistics. Applicable to 6500 platforms." ::= { cdx6500NMNPstats 43 } cdx6500NMNPSstatsEntry OBJECT-TYPE SYNTAX Cdx6500NMNPSstatsEntry ACCESS not-accessible STATUS optional DESCRIPTION "A Board statistics Table entry. Each entry contains statistics parameters for a single board. Applicable to 6500 platforms." INDEX { cdx6500NMNPSstatsBoard } ::= { cdx6500NMNPSstatsTable 1 } Cdx6500NMNPSstatsEntry ::= SEQUENCE{ cdx6500NMNPSstatsBoard INTEGER, cdx6500NMNPSstatsbuffDataAvail INTEGER, cdx6500NMNPSstatsbuffDataUse INTEGER, cdx6500NMNPSstatsbuffDataGauge Gauge, cdx6500NMNPSstatsmemEprom INTEGER, cdx6500NMNPSstatsmemDram INTEGER, cdx6500NMNPSstatsmemFlash INTEGER, cdx6500NMNPSstatscpuUtil INTEGER, cdx6500NMNPSstatsMaxcpuUtil INTEGER, cdx6500NMNPSstatsMaxcpuUtilTime DisplayString } cdx6500NMNPSstatsBoard OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Board number. Applicable to 6500 platforms." ::= { cdx6500NMNPSstatsEntry 1 } cdx6500NMNPSstatsbuffDataAvail OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The number of data buffers available. Applicable to 6500 platforms." ::= { cdx6500NMNPSstatsEntry 2 } cdx6500NMNPSstatsbuffDataUse OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The number of data buffers in use. Applicable to 6500 platforms." ::= { cdx6500NMNPSstatsEntry 3 } cdx6500NMNPSstatsbuffDataGauge OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS optional DESCRIPTION "The maximum number of data buffers in use since last reset Applicable to 6500 platforms." ::= { cdx6500NMNPSstatsEntry 4 } cdx6500NMNPSstatsmemEprom OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Amount of memory available on the processor card in bytes. Applicable to 6500 platforms." ::= { cdx6500NMNPSstatsEntry 5 } cdx6500NMNPSstatsmemDram OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Amount of memory used for data buffers in bytes. Applicable to 6500 platforms." ::= { cdx6500NMNPSstatsEntry 6 } cdx6500NMNPSstatsmemFlash OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The size of the flash module in bytes. This refers to the currently selected bank of flash when there is an alternate bank of flash installed. Applicable to 6500 platforms." ::= { cdx6500NMNPSstatsEntry 7 } cdx6500NMNPSstatscpuUtil OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Percentage of time the CPU processed traffic data (as opposed performing diagnositic tests or processing node control data) to in the last 64 seconds. Applicable to 6500 platforms." ::= { cdx6500NMNPSstatsEntry 8 } cdx6500NMNPSstatsMaxcpuUtil OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Peak CPU Utilization since last node or statistics reset. Applicable to 6500 platforms." ::= { cdx6500NMNPSstatsEntry 9 } cdx6500NMNPSstatsMaxcpuUtilTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Time stamp of Peak CPU Utilization since last node or statistics reset. Applicable to 6500 platforms." ::= { cdx6500NMNPSstatsEntry 10 } cdx6500NMNPScallsInPlaceMaxTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of Max number of calls since the last reset." ::= { cdx6500NMNPstats 44 } cdx6500NMNPSPVCConnectMaxTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of Max number of PVC connections since the last reset." ::= { cdx6500NMNPstats 45 } cdx6500NMNPScallsPerSecMaxTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of Max number of calls/sec since the last reset." ::= { cdx6500NMNPstats 46 } cdx6500NMNPSbuffDataGaugeTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Time stamp of Max number of data buffers in use since the last reset. Applicable to all platforms." ::= { cdx6500NMNPstats 47 } cdx6500NMNPSbuffPacketGauge OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS optional DESCRIPTION "The maximum number of packet buffers in use since the last reset. Applicable to all platforms except VG100." ::= { cdx6500NMNPstats 48 } cdx6500NMNPSbuffPacketGaugeTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Time stamp of Max number of packet buffers in use since the last reset. Applicable to all platforms except VG100." ::= { cdx6500NMNPstats 49 } cdx6500NMNPSbuffMgtGauge OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS optional DESCRIPTION "The maximum number of management buffers in use since the last reset. Applicable to all platforms except VG100." ::= { cdx6500NMNPstats 50 } cdx6500NMNPSbuffMgtGaugeTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Time stamp of Max number of management buffers in use since the last reset. Applicable to all platforms except VG100." ::= { cdx6500NMNPstats 51 } cdx6500NMNPSrateMaxCharTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of Max node throughput (chars/sec) since the last reset." ::= { cdx6500NMNPstats 52 } cdx6500NMNPSrateMaxPktTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of Max node throughput (packets/sec) since the last reset." ::= { cdx6500NMNPstats 53 } cdx6500NMNPSMaxcpuUtil OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Peak CPU Utilization since last node or statistics reset. Applicable to 6520 platforms." ::= { cdx6500NMNPstats 54 } cdx6500NMNPSMaxcpuUtilTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Time stamp of Peak CPU Utilization since last node or statistics reset. Applicable to 6520 platforms." ::= { cdx6500NMNPstats 55 } -- The Report Statistics Table -- This table contains statistics paramaters -- for the Report Operator event log table. cdx6500NMReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500NMReportEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the statistics parameters relevant to the Report event log table." ::= { cdx6500NMDiagnosticsGroup 1 } cdx6500NMReportEntry OBJECT-TYPE SYNTAX Cdx6500NMReportEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Report Statistics parameters." INDEX { cdx6500reptIndex } ::= { cdx6500NMReportTable 1 } Cdx6500NMReportEntry ::= SEQUENCE { cdx6500reptIndex INTEGER, cdx6500reptEvent DisplayString } cdx6500reptIndex OBJECT-TYPE SYNTAX INTEGER (1..512) ACCESS not-accessible STATUS mandatory DESCRIPTION "Report Log Index" ::= { cdx6500NMReportEntry 1 } cdx6500reptEvent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..152)) ACCESS read-only STATUS mandatory DESCRIPTION "Report Log Alarm Text" ::= { cdx6500NMReportEntry 2 } cdx6500NMreptClearLog OBJECT-TYPE SYNTAX INTEGER { clearLog (1), noClearLog (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Clears the Operator log. clearLog - Clear the Log noClearLog - Do not clear the Log." ::= { cdx6500NMDiagnosticsGroup 2 } -- The V54 Loopback group, part of Pegasus Diagnostics -- This Group contains controls, configurables, and statistics -- parameters related to invoking and monitoring loopback tests. cdx6500NMV54Loopback OBJECT IDENTIFIER ::= { cdx6500NMDiagnosticsGroup 3 } cdx6500NMV54LocalLoop OBJECT-TYPE SYNTAX INTEGER { startTest (1), noTest (2) } ACCESS write-only STATUS obsolete DESCRIPTION "Local loop test; The test will start when set to value 'startTest'." ::= { cdx6500NMV54Loopback 1 } cdx6500NMV54Loop2 OBJECT-TYPE SYNTAX INTEGER { startTest (1), noTest (2) } ACCESS write-only STATUS obsolete DESCRIPTION "Loopback test 2 : Loop at remote modem digital side." ::= { cdx6500NMV54Loopback 2 } cdx6500NMV54Loop3 OBJECT-TYPE SYNTAX INTEGER { startTest (1), noTest (2) } ACCESS write-only STATUS obsolete DESCRIPTION "Loopback test 3: Loop at local modem analog side." ::= { cdx6500NMV54Loopback 3 } cdx6500NMV54turnLoopbackOff OBJECT-TYPE SYNTAX INTEGER { loopbackOff(1) } ACCESS write-only STATUS obsolete DESCRIPTION "A control to turn any loopback test off" ::= { cdx6500NMV54Loopback 4 } cdx6500NMV54LoopbackDuration OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Duration of loopback in seconds." ::= { cdx6500NMV54Loopback 5 } cdx6500NMV54TestType OBJECT-TYPE SYNTAX INTEGER { v54LocalLoop (1), v54Loop2 (2), v54Loop3 (3) } ACCESS read-only STATUS obsolete DESCRIPTION "Loopback test type." ::= { cdx6500NMV54Loopback 6 } cdx6500NMV54LoopbackStatus OBJECT-TYPE SYNTAX INTEGER { v54Starting (1), v54Running (2), v54Stopping (3), v54Clearing (4), v54Stopped (5), v54AbortPortDisabled (6), v54AbortIsRunning (7), v54AbortPortNull (8), v54AbortEiaDisc (9), v54AbortCpuNotRunning (10), v54AbortNotSupported (11), v54AbortWrongParams (12), v54AbortWrongPort (13), v54NotRun (14) } ACCESS read-only STATUS mandatory DESCRIPTION "Loopback Status. v54Starting - test is being prepared to start. v54Running - test in progress. v54Stopping - test is being stopped. v54Clearing - system is clearing resources used for the test. v54Stopped - test has been completed. v54AbortPortDisabled - selected port is disabled. v54AbortIsRunning - test is already running on the specified port. v54AbortPortNull - selected port is of NULL type. v54AbortEiaDisc - interface has been disconnected during the test. v54AbortCpuNotRunning - CPU is not running on the specified port. v54AbortNotSupported - specified test is not supported by the selected port. v54AbortWrongParams - specified test params are incorrect. Check port number. v54AbortWrongPort - specified port is incorrect. v54NotRun - test has not been run yet." ::= { cdx6500NMV54Loopback 7 } cdx6500NMV54MessagesSent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Number of messages sent" ::= { cdx6500NMV54Loopback 9} cdx6500NMV54GoodMsgsReceived OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Number of good messages received" ::= { cdx6500NMV54Loopback 10 } cdx6500NMV54BadMsgsReceived OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "Number of bad messages received" ::= { cdx6500NMV54Loopback 11 } cdx6500NMV54LastPortTested OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS obsolete DESCRIPTION "Last port to be put in loopback." ::= { cdx6500NMV54Loopback 12 } cdx6500NMV54CurrentTestPort OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-write STATUS obsolete DESCRIPTION "Current test port." ::= { cdx6500NMV54Loopback 13 } cdx6500NMV54LoopbackTest OBJECT-TYPE SYNTAX INTEGER {testing (1), notTesting (2)} ACCESS read-write STATUS mandatory DESCRIPTION "Starts and stops loopback test." ::= { cdx6500NMV54Loopback 14 } cdx6500NMV54LoopbackTestType OBJECT-TYPE SYNTAX INTEGER { v54LocalLoop (1), v54Loop2 (2), v54Loop3 (3), dsuInternal (4), dsuInternalExternal (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Loopback test type. v54LocalLoop - creates a loop on the selected port. v54Loop2 - creates a loop on the remote modem digital side. v54Loop3 - creates a loop on the local modem analog side. dsuInternal - creates a loop on the internal interface. dsuInternalExternal - creates a loop on the internal and the external interfaces." ::= { cdx6500NMV54Loopback 15 } cdx6500NMV54LoopbackLastPortTested OBJECT-TYPE SYNTAX INTEGER (0..54) ACCESS read-only STATUS mandatory DESCRIPTION "Last port put in loopback." ::= { cdx6500NMV54Loopback 16 } cdx6500NMV54LoopbackCurrentTestPort OBJECT-TYPE SYNTAX INTEGER (0..54) ACCESS read-write STATUS mandatory DESCRIPTION "Current test port. Value zero means that no port has been specified. When test completes, this object is defaulted to zero." ::= { cdx6500NMV54Loopback 17 } cdx6500NMV54LoopbackMessagesSent OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of messages sent" ::= { cdx6500NMV54Loopback 18} cdx6500NMV54LoopbackGoodMsgsReceived OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of good messages received" ::= { cdx6500NMV54Loopback 19} cdx6500NMV54LoopbackBadMsgsReceived OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bad messages received" ::= { cdx6500NMV54Loopback 20} -- Node Management Controls Group cdx6500NMCBootNode OBJECT-TYPE SYNTAX INTEGER { bootCold (0), bootWarm (1), newvalBootCold (50) } ACCESS write-only STATUS mandatory DESCRIPTION "Setting this object will cuase the node to perform either a cold or a warm Node boot : bootCold - perform a cold Node Boot; run diagnostic tests, reload operational software, request software download if neccessary, reload configuration and start the node. bootWarm - perform a warm Node Boot; reload configuration and start the node. newvalBootCold - same functionality as 'bootCold', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMControlsGroup 1 } cdx6500NMCBootTableNodeRec OBJECT-TYPE SYNTAX INTEGER { bootrec (1) } ACCESS write-only STATUS mandatory DESCRIPTION "Setting to bootrec will cause the running configuration to be updated using new configuration tables from CMEM." ::= { cdx6500NMControlsGroup 2 } -- DLSV Group cdx6500DLSVDLstate OBJECT-TYPE SYNTAX INTEGER { dlStart (1), dlCall (2), dlReq (3), dlLoad (4), dlGss (8), dlLgs (16), dlDone (32), dlBoot (64), dlIdle (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Statistic - state of the download dlStart : Setup phase. dlCall : Setup phase. dlReq : Setup phase. dlLoad : Downloading phase. dlGss : Setup phase. dlLgs : Downloading phase. dlDone : Download Complete. dlBoot : Download Complete. dlIdle : No download." ::= { cdx6500NMDLSVGroup 1 } cdx6500DLSVPercentComplete OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Statistic - amount of download that has completed." ::= { cdx6500NMDLSVGroup 2 } cdx6500DLSVTimestamp OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Statistic - time of last download." ::= { cdx6500NMDLSVGroup 3 } cdx6500DLSVLastServer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Statistic - Last server node to send software." ::= { cdx6500NMDLSVGroup 4 } cdx6500DLSVTransferType OBJECT-TYPE SYNTAX INTEGER { idle (1), ramToram (2), flashToflash (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Statistic - type of transfer - i.e. which bank to which bank at what throughput." ::= { cdx6500NMDLSVGroup 5 } cdx6500DLSVInitiateTransfer OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Type of transfer - i.e. which bank to which bank at what throughput setting this initiates the flash to flash transfer." ::= { cdx6500NMDLSVGroup 6 } cdx6500DLSVAgntSegmentSize OBJECT-TYPE SYNTAX INTEGER { segmentSizeDisable (0), segmentSize16 (4), segmentSize32 (5), segmentSize64 (6), segmentSize128 (7), segmentSize256 (8), segmentSize512 (9), segmentSize1024 (10), newvalSegmentSizeDisable (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the segment size used for accounting purposes with data packets. segmentSizeDisable - segment counting disabled. segmentSize16 - 16 byte segments. segmentSize32 - 32 byte segments. segmentSize64 - 64 byte segments. segmentSize128 - 128 byte segments. segmentSize256 - 256 byte segments. segmentSize512 - 512 byte segments. segmentSize1024 - 1024 byte segments newvalSegmentSizeDisable - same as 'segmentSizeDisable', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMDLSVGroup 7 } cdx6500DLSVAgntnmServAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the mnemonic name of the download server assigned to load this node with operational software." ::= { cdx6500NMDLSVGroup 8 } cdx6500DLSVagntloaderSubaddress OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the subaddress of the download module in this node." ::= { cdx6500NMDLSVGroup 9 } cdx6500DLSVagntdlServSubaddress OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Calls with network address composed of the node address (configured in the Node record) and this subaddress will be routed to the module in this node which sends code to a remote node. No routing table entry is needed." ::= { cdx6500NMDLSVGroup 10 } -- The Statistics Tables -- The allPorts Statistics Table -- This table contains statistic parameters -- for the allPorts table. cdx6500PPSTallPortsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTallPortsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the statistics parameters relevant to the allPorts table." ::= { cdx6500PSTPortProtocolGroup 18 } cdx6500PPSTallPortsEntry OBJECT-TYPE SYNTAX Cdx6500PPSTallPortsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of allPorts statistics parameters." INDEX { cdx6500allportsPortNum } ::= { cdx6500PPSTallPortsTable 1 } Cdx6500PPSTallPortsEntry ::= SEQUENCE { cdx6500allportsPortNum INTEGER, cdx6500allportsPortType INTEGER, cdx6500allportsPortStatus INTEGER, cdx6500allportsPortState DisplayString, cdx6500allportsPortSpeed INTEGER, cdx6500allportsUtilizationIn INTEGER, cdx6500allportsUtilizationOut INTEGER, cdx6500allportsCharInTot Counter, cdx6500allportsCharOutTot Counter, cdx6500allportsPktInTot Counter, cdx6500allportsPktOutTot Counter, cdx6500allportsFrameInTot Counter, cdx6500allportsFrameOutTot Counter, cdx6500allportsPktsQueued INTEGER, cdx6500allportsCharsInPerSec INTEGER, cdx6500allportsCharsOutPerSec INTEGER, cdx6500allportsPktsInPerSec INTEGER, cdx6500allportsPktsOutPerSec INTEGER, cdx6500allportsFramesInPerSec INTEGER, cdx6500allportsFramesOutPerSec INTEGER, cdx6500allportsOverrunErrors Counter16, cdx6500allportsUnderrunErrors Counter16, cdx6500allportsCRCErrors Counter16, cdx6500allportsParityErrors Counter16, cdx6500allportsFramingErrors Counter16, cdx6500allportsBootPort INTEGER, cdx6500allportsPortControlStatus INTEGER } cdx6500allportsPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the port" ::= { cdx6500PPSTallPortsEntry 1 } cdx6500allportsPortType OBJECT-TYPE SYNTAX INTEGER { null (1), pad (2), x25 (3), mux (4), mx25 (9), bsc2780 (11), bsc3270 (12), vip (13), pos (14), sdlc (15), ncrbsc (16), fri (17), xdlc (18), bstd (19), rs366 (20), ibm2260 (23), vap (24), tbop (25), n270 (26), tcop (27), tr (28), eth (29), alc (31), sl (32), fra (33), t3pos (34), atpad (35), tnpp (36), slip (37), hub (39), bri (40), x32pcm (41), ppp (42), voice (43), t1 (44), e1 (45), tdlc (48), ptype3201 (50), gsc (51), spp (52), t1e1 (54), t3e3 (55), atm (56) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of port." ::= { cdx6500PPSTallPortsEntry 2 } cdx6500allportsPortStatus OBJECT-TYPE SYNTAX INTEGER { disabled (0), enabled (1), busyOut (2), up (3), down (4), newvalDisabled (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the port. disabled - Port is disabled. enabled - Port is enabled. busyOut - Port is busyOuted. up - Port is up. down - Port is down. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility." ::= { cdx6500PPSTallPortsEntry 3 } cdx6500allportsPortState OBJECT-TYPE SYNTAX DisplayString (SIZE(1..25)) ACCESS read-only STATUS mandatory DESCRIPTION "Current Port state." ::= { cdx6500PPSTallPortsEntry 4 } cdx6500allportsPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the speed of the port when Clock=Int; this is detected clock speed if Clock=Ext. If Port Speed is 0, Clock=Ext then clocking is not being received from attached device." ::= { cdx6500PPSTallPortsEntry 5 } cdx6500allportsUtilizationIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Percentage of port bandwidth in use." ::= { cdx6500PPSTallPortsEntry 6 } cdx6500allportsUtilizationOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Percentage of port bandwidth in use." ::= { cdx6500PPSTallPortsEntry 7 } cdx6500allportsCharInTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters received by the port since the last node, port or statistics reset." ::= { cdx6500PPSTallPortsEntry 8 } cdx6500allportsCharOutTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters sent by the port since the last node, port or statistics reset." ::= { cdx6500PPSTallPortsEntry 9 } cdx6500allportsPktInTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets received by the port since the last node, port or statistics reset." ::= { cdx6500PPSTallPortsEntry 10 } cdx6500allportsPktOutTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets sent by the port since the last node, port or statistics reset." ::= { cdx6500PPSTallPortsEntry 11 } cdx6500allportsFrameInTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received by the port since the last node, port or statistics reset." ::= { cdx6500PPSTallPortsEntry 12 } cdx6500allportsFrameOutTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent by the port since the last node, port or statistics reset." ::= { cdx6500PPSTallPortsEntry 13 } cdx6500allportsPktsQueued OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets currently queued." ::= { cdx6500PPSTallPortsEntry 14} cdx6500allportsCharsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the characters being received over the port." ::= { cdx6500PPSTallPortsEntry 15 } cdx6500allportsCharsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the characters being sent over the port." ::= { cdx6500PPSTallPortsEntry 16 } cdx6500allportsPktsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the packets being received over the port." ::= { cdx6500PPSTallPortsEntry 17 } cdx6500allportsPktsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the packets being sent over the port." ::= { cdx6500PPSTallPortsEntry 18 } cdx6500allportsFramesInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the frames being received over the port." ::= { cdx6500PPSTallPortsEntry 19 } cdx6500allportsFramesOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the frames being sent over the port." ::= { cdx6500PPSTallPortsEntry 20 } cdx6500allportsOverrunErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of Overrun errors since the last node or statistics reset. Overrun Errors: Received data was lost because it could not be processed by the CPU." ::= { cdx6500PPSTallPortsEntry 21 } cdx6500allportsUnderrunErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of Underrun errors since the last node or statistics reset. UnderrunErrors: Transmission of a frame could not be completed because all the data had not been sent to port." ::= { cdx6500PPSTallPortsEntry 22 } cdx6500allportsCRCErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of CRC errors since the last node or statistics reset. CRC Errors: Cyclical Redundancy failure because of noise on the line." ::= { cdx6500PPSTallPortsEntry 23 } cdx6500allportsParityErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of Parity errors since the last reset" ::= { cdx6500PPSTallPortsEntry 24 } cdx6500allportsFramingErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of Framing errors since the last reset." ::= { cdx6500PPSTallPortsEntry 25 } cdx6500allportsBootPort OBJECT-TYPE SYNTAX INTEGER { bootPort (1) } ACCESS write-only STATUS mandatory DESCRIPTION "Boots the specified Port. bootPort - Boot the Port." ::= { cdx6500PPSTallPortsEntry 26 } cdx6500allportsPortControlStatus OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2), busyout (3) } ACCESS write-only STATUS mandatory DESCRIPTION "Change the Port Control Status. enable - Enable the Port. disable - Disable the Port. busyout - BusyOut the Port." ::= { cdx6500PPSTallPortsEntry 27 } -- The allStations Statistics Table -- This table contains statistic paramaters -- for the allStations table. cdx6500SPSTallStationsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPSTallStationsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the statistics parameters relevant to the allStations table." ::= { cdx6500PSTStationProtocolGroup 8 } cdx6500SPSTallStationsEntry OBJECT-TYPE SYNTAX Cdx6500SPSTallStationsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of allStations statistics parameters." INDEX { cdx6500allstationsPortNum, cdx6500allstationsStnNum } ::= { cdx6500SPSTallStationsTable 1 } Cdx6500SPSTallStationsEntry ::= SEQUENCE { cdx6500allstationsPortNum INTEGER, cdx6500allstationsStnNum INTEGER, cdx6500allstationsStnType DisplayString, cdx6500allstationsStnStatus INTEGER, cdx6500allstationsStnState DisplayString, cdx6500allstationsUtilizationIn INTEGER, cdx6500allstationsUtilizationOut INTEGER, cdx6500allstationsCharInTot Counter, cdx6500allstationsCharOutTot Counter, cdx6500allstationsPktInTot Counter, cdx6500allstationsPktOutTot Counter, cdx6500allstationsFrameInTot Counter, cdx6500allstationsFrameOutTot Counter, cdx6500allstationsPktsQueued INTEGER, cdx6500allstationsCharsInPerSec INTEGER, cdx6500allstationsCharsOutPerSec INTEGER, cdx6500allstationsPktsInPerSec INTEGER, cdx6500allstationsPktsOutPerSec INTEGER, cdx6500allstationsFramesInPerSec INTEGER, cdx6500allstationsFramesOutPerSec INTEGER, cdx6500allstationsBootStation INTEGER, cdx6500allstationsDisableStation INTEGER, cdx6500allstationsEnableStation INTEGER, cdx6500allstationsBusyOutStation INTEGER } cdx6500allstationsPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the port." ::= { cdx6500SPSTallStationsEntry 1 } cdx6500allstationsStnNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of the station." ::= { cdx6500SPSTallStationsEntry 2 } cdx6500allstationsStnType OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "Type of station." ::= { cdx6500SPSTallStationsEntry 3 } cdx6500allstationsStnStatus OBJECT-TYPE SYNTAX INTEGER { disabled (0), enabled (1), busyOut (2), up (3), down (4), newvalDisabled (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the station. disabled - Station is disabled. enabled - Station is enabled. busyOut - Station is busyOuted. up - Station is up. down - Station is down. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility." ::= { cdx6500SPSTallStationsEntry 4 } cdx6500allstationsStnState OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "Current Station state." ::= { cdx6500SPSTallStationsEntry 5 } cdx6500allstationsUtilizationIn OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Percentage of station bandwidth in use." ::= { cdx6500SPSTallStationsEntry 6 } cdx6500allstationsUtilizationOut OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Percentage of station bandwidth in use." ::= { cdx6500SPSTallStationsEntry 7 } cdx6500allstationsCharInTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters received by the station since the last node, port, station or statistics reset." ::= { cdx6500SPSTallStationsEntry 8 } cdx6500allstationsCharOutTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters sent by the station since the last node, port, station or statistics reset." ::= { cdx6500SPSTallStationsEntry 9 } cdx6500allstationsPktInTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets received by the station since the last node, port, station or statistics reset." ::= { cdx6500SPSTallStationsEntry 10 } cdx6500allstationsPktOutTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets sent by the port since the last node, port, station or statistics reset." ::= { cdx6500SPSTallStationsEntry 11 } cdx6500allstationsFrameInTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received by the port since the last node, port, station or statistics reset." ::= { cdx6500SPSTallStationsEntry 12 } cdx6500allstationsFrameOutTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent by the port since the last node, port, station or statistics reset." ::= { cdx6500SPSTallStationsEntry 13 } cdx6500allstationsPktsQueued OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets currently queued." ::= { cdx6500SPSTallStationsEntry 14} cdx6500allstationsCharsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the characters being received over the station." ::= { cdx6500SPSTallStationsEntry 15 } cdx6500allstationsCharsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the characters being sent over the station." ::= { cdx6500SPSTallStationsEntry 16 } cdx6500allstationsPktsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the packets being received over the station." ::= { cdx6500SPSTallStationsEntry 17 } cdx6500allstationsPktsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the packets being sent over the station." ::= { cdx6500SPSTallStationsEntry 18 } cdx6500allstationsFramesInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the frames being received over the station." ::= { cdx6500SPSTallStationsEntry 19 } cdx6500allstationsFramesOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the frames being sent over the station." ::= { cdx6500SPSTallStationsEntry 20 } cdx6500allstationsBootStation OBJECT-TYPE SYNTAX INTEGER { bootStn (1), noBootStn (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Boots the specified station. bootStn - Boot Station noBootStn - Do not boot Station." ::= { cdx6500SPSTallStationsEntry 21 } cdx6500allstationsDisableStation OBJECT-TYPE SYNTAX INTEGER { disableStn (1), noDisableStn (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Disables the specified station. disableStn - Disable Station. noDisableStn - Do not disable Station." ::= { cdx6500SPSTallStationsEntry 22 } cdx6500allstationsEnableStation OBJECT-TYPE SYNTAX INTEGER { enableStn (1), noEnableStn (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Enables the specified station. enableStn - Enable Station. noEnableStn - Not not enable Station." ::= { cdx6500SPSTallStationsEntry 23 } cdx6500allstationsBusyOutStation OBJECT-TYPE SYNTAX INTEGER { busyoutStn (1), noBusyoutStn (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Busy out the specified station. busyoutStn - Busyout Station. noBusyoutStn - Do not busyout Station." ::= { cdx6500SPSTallStationsEntry 24 } -- General Objects -- The ROUT selection configuration table -- Implementation of the ROUT group is mandatory for Pegasus BN. -- It is also available on the other 65xx and VGxxx platforms. cdx6500GCTRouteSelectionTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500GCTRouteSelectionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Configuration Parameters that select the links over which calls are routed." ::= { cdx6500CfgGeneralGroup 1 } cdx6500GCTRouteSelectionEntry OBJECT-TYPE SYNTAX Cdx6500GCTRouteSelectionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains a list of parameters that makeup the Route Selection Table." INDEX { cdx6500RoutSVCEntryNumber } ::= { cdx6500GCTRouteSelectionTable 1 } Cdx6500GCTRouteSelectionEntry ::= SEQUENCE { cdx6500RoutSVCEntryNumber INTEGER, cdx6500RoutSVCAddress INTEGER, cdx6500RoutSVCDestination1 DisplayString, cdx6500RoutSVCPriority1 INTEGER, cdx6500RoutSVCDestination2 DisplayString, cdx6500RoutSVCPriority2 INTEGER, cdx6500RoutSVCDestination3 DisplayString, cdx6500RoutSVCPriority3 INTEGER, cdx6500RoutSVCDestination4 DisplayString, cdx6500RoutSVCPriority4 INTEGER, cdx6500RoutSVCDestination5 DisplayString, cdx6500RoutSVCPriority5 INTEGER, cdx6500RoutSVCDestination6 DisplayString, cdx6500RoutSVCPriority6 INTEGER, cdx6500RoutSVCDestination7 DisplayString, cdx6500RoutSVCPriority7 INTEGER, cdx6500RoutSVCDestination8 DisplayString, cdx6500RoutSVCPriority8 INTEGER, cdx6500RoutSVCAddress1 DisplayString } cdx6500RoutSVCEntryNumber OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configurable parameter. This identifies the particular Route Selection Table entry being configured by the other parameters in the record." ::= { cdx6500GCTRouteSelectionEntry 1 } cdx6500RoutSVCAddress OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "This is a non-supported object. It has been replaced by cdx6500RoutSVCAddress1." ::= { cdx6500GCTRouteSelectionEntry 2 } cdx6500RoutSVCDestination1 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource." ::= { cdx6500GCTRouteSelectionEntry 3 } cdx6500RoutSVCPriority1 OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest." ::= { cdx6500GCTRouteSelectionEntry 4 } cdx6500RoutSVCDestination2 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource." ::= { cdx6500GCTRouteSelectionEntry 5 } cdx6500RoutSVCPriority2 OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest." ::= { cdx6500GCTRouteSelectionEntry 6 } cdx6500RoutSVCDestination3 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource." ::= { cdx6500GCTRouteSelectionEntry 7 } cdx6500RoutSVCPriority3 OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest." ::= { cdx6500GCTRouteSelectionEntry 8 } cdx6500RoutSVCDestination4 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource." ::= { cdx6500GCTRouteSelectionEntry 9 } cdx6500RoutSVCPriority4 OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest." ::= { cdx6500GCTRouteSelectionEntry 10 } cdx6500RoutSVCDestination5 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource." ::= { cdx6500GCTRouteSelectionEntry 11 } cdx6500RoutSVCPriority5 OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest." ::= { cdx6500GCTRouteSelectionEntry 12 } cdx6500RoutSVCDestination6 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource." ::= { cdx6500GCTRouteSelectionEntry 13 } cdx6500RoutSVCPriority6 OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest." ::= { cdx6500GCTRouteSelectionEntry 14 } cdx6500RoutSVCDestination7 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource." ::= { cdx6500GCTRouteSelectionEntry 15 } cdx6500RoutSVCPriority7 OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest." ::= { cdx6500GCTRouteSelectionEntry 16 } cdx6500RoutSVCDestination8 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource." ::= { cdx6500GCTRouteSelectionEntry 17 } cdx6500RoutSVCPriority8 OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest." ::= { cdx6500GCTRouteSelectionEntry 18 } cdx6500RoutSVCAddress1 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Network address for calls routed beyond this node. A route selection entry is not needed for calls destined within this node: PAD port or node resource (for example, control port) calls. The wild card(match anything) character is * and can also be part of the entry. When set to (blank), this parameter is ignored." ::= { cdx6500GCTRouteSelectionEntry 19 } -- The PVC Setup configuration table cdx6500GCTPVCSetupTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500GCTPVCSetupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Configuration Parameters for PVCs." ::= { cdx6500CfgGeneralGroup 5 } cdx6500GCTPVCSetupEntry OBJECT-TYPE SYNTAX Cdx6500GCTPVCSetupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains a PVC source and PVC destination." INDEX { cdx6500PVCSetupEntryNumber } ::= { cdx6500GCTPVCSetupTable 1 } Cdx6500GCTPVCSetupEntry ::= SEQUENCE { cdx6500PVCSetupEntryNumber INTEGER, cdx6500PVCSetupSource DisplayString, cdx6500PVCSetupDestination DisplayString } cdx6500PVCSetupEntryNumber OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configurable parameter. This identifies the particular PVC Table entry being configured by the other parameters in the record." ::= { cdx6500GCTPVCSetupEntry 1 } cdx6500PVCSetupSource OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This is the PVC source channel identifier. Entries are not case sensitive. For example: BCST route calls to the broadcast module. MX25-2s3(2) route calls to MX25 port 2, station 3, channel 2. PAD-5 route calls to PAD port 5. P54S9(22) route calls to port 54, station 9, channel 22. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1(5) route calls to X25 port 1, channel 5." ::= { cdx6500GCTPVCSetupEntry 2 } cdx6500PVCSetupDestination OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This is the PVC destination channel identifier. Entries are not case sensitive. For example: BCST route calls to the broadcast module. MX25-2s3(2) route calls to MX25 port 2, station 3, channel 2. PAD-5 route calls to PAD port 5. P54S9(22) route calls to port 54, station 9, channel 22. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1(5) route calls to X25 port 1, channel 5." ::= { cdx6500GCTPVCSetupEntry 3 } -- The Mnemonic Configuration Table -- This table contains Configuration paramaters -- for the Mnemonic table. cdx6500CfgMnemonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500CfgMnemonicEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the Mnemonic table." ::= { cdx6500CfgGeneralGroup 6 } cdx6500CfgMnemonicEntry OBJECT-TYPE SYNTAX Cdx6500CfgMnemonicEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of mnemonic configuration parameters." INDEX { cdx6500mnemEntryNum } ::= { cdx6500CfgMnemonicTable 1 } Cdx6500CfgMnemonicEntry ::= SEQUENCE { cdx6500mnemEntryNum INTEGER, cdx6500mnemName DisplayString, cdx6500mnemx28Cmd DisplayString } cdx6500mnemEntryNum OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configuration parameter. Instead, it identifies the particular Mnemonic Table entry being configured by the other parameters in the record. NOTE: You can have up to 256 entries for the 6507Plus and 6525Plus, but only 64 entries for the 6505Plus." ::= { cdx6500CfgMnemonicEntry 1 } cdx6500mnemName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This is an mnemonic name available to PAD port users for abbreviated calling or autocalling. The following parameter will specify call details. The mnemonic CTP is reserved and specifies a call to the control port." ::= { cdx6500CfgMnemonicEntry 2 } cdx6500mnemx28Cmd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies call details for the mnemonic configured in the previous parameter. Use the format of an X.28 call command, but leave out the command specifier (the c or call)." ::= { cdx6500CfgMnemonicEntry 3 } -- The CSIS NUI Password Table cdx6500GCTNUIPasswordTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500GCTNUIPasswordEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of NUI/Password configuration entries." ::= { cdx6500CfgGeneralGroup 7 } cdx6500GCTNUIPasswordEntry OBJECT-TYPE SYNTAX Cdx6500GCTNUIPasswordEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Network User Identification (NUI)/Password Table." INDEX { cdx6500NUITEntryNumber } ::= { cdx6500GCTNUIPasswordTable 1 } Cdx6500GCTNUIPasswordEntry ::= SEQUENCE { cdx6500NUITEntryNumber INTEGER, cdx6500NUITAcctName DisplayString, cdx6500NUITPasswd DisplayString, cdx6500NUITPADPromptNum INTEGER } cdx6500NUITEntryNumber OBJECT-TYPE SYNTAX INTEGER (1..400) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configurable parameter. Instead, it identifies the particular NUI/Password Table entry being configured by the other parameters in the record." ::= { cdx6500GCTNUIPasswordEntry 1 } cdx6500NUITAcctName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the account name for billing records." ::= { cdx6500GCTNUIPasswordEntry 2 } cdx6500NUITPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the password for the account name." ::= { cdx6500GCTNUIPasswordEntry 3 } cdx6500NUITPADPromptNum OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies which entry in the PAD Prompt Table is used as a PAD prompt after the user has entered a valid password. Use 0 for standard asterisk prompt." ::= { cdx6500GCTNUIPasswordEntry 4 } -- The CSIS Software Key Table cdx6500GCTSoftwareKeyTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500GCTSoftwareKeyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Software Key configuration entries." ::= { cdx6500CfgGeneralGroup 12 } cdx6500GCTSoftwareKeyEntry OBJECT-TYPE SYNTAX Cdx6500GCTSoftwareKeyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Software Key for a specific optional software product code." INDEX { cdx6500CSISSoftKeyEntryNumber } ::= { cdx6500GCTSoftwareKeyTable 1 } Cdx6500GCTSoftwareKeyEntry ::= SEQUENCE { cdx6500CSISSoftKeyEntryNumber INTEGER, cdx6500CSISSoftKeyValue DisplayString } cdx6500CSISSoftKeyEntryNumber OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configurable parameter. It is the reference number for the individual software option that is being enabled. You must configure a separate entry for each software option enabled at the node. A node may have up to 20 options enabled at one time." ::= { cdx6500GCTSoftwareKeyEntry 1 } cdx6500CSISSoftKeyValue OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "This is a software key supplied by Codex Corporation for this node." ::= { cdx6500GCTSoftwareKeyEntry 2 } -- Other Statistics -- CSIS Option and Port Authorization cdx6500OSTCSISOptionStatTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500OSTCSISOptionStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table describing the Software Options that have been purchased and enabled for this node." ::= { cdx6500StatOtherStatsGroup 5 } cdx6500OSTCSISOptionStatEntry OBJECT-TYPE SYNTAX Cdx6500OSTCSISOptionStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of objects describing a single Software Option." INDEX { cdx6500CSISOptionNumber } ::= { cdx6500OSTCSISOptionStatTable 1 } Cdx6500OSTCSISOptionStatEntry ::= SEQUENCE { cdx6500CSISOptionNumber INTEGER, cdx6500CSISMaxAllowed INTEGER, cdx6500CSISNumUsed INTEGER, cdx6500CSISOptionAuth INTEGER } cdx6500CSISOptionNumber OBJECT-TYPE SYNTAX INTEGER (1..55) ACCESS read-only STATUS mandatory DESCRIPTION "Table index, which is code for the software option. Following are the various software options and their codes. 1 - MX25 2 - SDLC 3 - BSC3270 4 - BSC2780 5 - VIP 6 - VIDEOTEX 7 - Data/Connection Protect 8 - INL backup 9 - FR DTE Interface 10 - 6600 ETM 11 - NCRBSC 12 - TRANSPARENT POLLED ASYNC 13 - INTERNAL DSD 14 - 801 AUTODIALER 15 - BSTD 16 - FLASH Enable 17 - NCCP Pad 18 - TBOP 19 - Source Routing Bridge 22 - IBM2260 23 - XDLC 24 - Transparent Bridge 25 - Local Termination 26 - SR/TB Bridge 29 - IP Routing 31 - FR DCE Interface 32 - 6520 Model ID RN 33 - 6520 Model ID SN 34 - 6520 Model ID BN 40 - TCOP 42 - FrameRelay LLC Conversion 43 - IP stack on CPU+ 44 - TNPP-PAD Enable 45 - Token Ring LLC Conversion 46 - Ethernet LLC Conversion 50 - Dial-Out Routing Manager 51 - Dial-Out Routing Agent 52 - Chinapac Billing Feature 53 - Chinapac NUIC Interface 54 - X32 Port 55 - Chinapac NUI Concentrator." ::= { cdx6500OSTCSISOptionStatEntry 1 } cdx6500CSISMaxAllowed OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Number of ports that this option can support. Options can be purchased to support different numbers of ports. Value of 65535 indicates no limit." ::= { cdx6500OSTCSISOptionStatEntry 2 } cdx6500CSISNumUsed OBJECT-TYPE SYNTAX INTEGER (0..54) ACCESS read-only STATUS mandatory DESCRIPTION "The number of ports actually being used with this option." ::= { cdx6500OSTCSISOptionStatEntry 3 } cdx6500CSISOptionAuth OBJECT-TYPE SYNTAX INTEGER { unauthorized (1), authorized (2) } ACCESS read-only STATUS mandatory DESCRIPTION "unauthorized - an attempt was made to use an option that has not been purchased or enabled. authorized - all attempts to use the option were authorized." ::= { cdx6500OSTCSISOptionStatEntry 4 } -- CSIS Port Authorization Statistics cdx6500OSTCSISPortUsageTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500OSTCSISPortUsageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table providing statistics on unauthorized port usage." ::= { cdx6500StatOtherStatsGroup 6 } cdx6500OSTCSISPortUsageEntry OBJECT-TYPE SYNTAX Cdx6500OSTCSISPortUsageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of authorization statistics for a single port." INDEX { cdx6500CSISPortNumber } ::= { cdx6500OSTCSISPortUsageTable 1 } Cdx6500OSTCSISPortUsageEntry ::= SEQUENCE { cdx6500CSISPortNumber INTEGER, cdx6500CSISPortAuth INTEGER } cdx6500CSISPortNumber OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "The port's number." ::= { cdx6500OSTCSISPortUsageEntry 1 } cdx6500CSISPortAuth OBJECT-TYPE SYNTAX INTEGER { unauthorized (1), authorized (2) } ACCESS read-only STATUS mandatory DESCRIPTION "unauthorized - an attempt was made to use this port to exceed an option port limit. authorized - the port was not used in an unauthorized fashion." ::= { cdx6500OSTCSISPortUsageEntry 2 } -- SVC calls table cdx6500StatSVCTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500StatSVCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of currently active switched virtual circuits (SVC). The table is dynamic i.e. changing as queries are being performed on the table." ::= { cdx6500StatNetworkSvcsGroup 1} cdx6500StatSVCEntry OBJECT-TYPE SYNTAX Cdx6500StatSVCEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of objects describing a single SVC." INDEX { cdx6500StatSVCIndex} ::= { cdx6500StatSVCTable 1} Cdx6500StatSVCEntry ::= SEQUENCE { cdx6500StatSVCIndex INTEGER, cdx6500StatSVCCallingChannel DisplayString, cdx6500StatSVCCalledChannel DisplayString, cdx6500StatSVCReverseCharge INTEGER, cdx6500StatSVCFastSelect INTEGER, cdx6500StatSVCNetUserIdentification INTEGER, cdx6500StatSVCClosedUserGroup INTEGER, cdx6500StatSVCConnectionUPTime DisplayString } cdx6500StatSVCIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "It is position in the list of SVC's." ::= { cdx6500StatSVCEntry 1 } cdx6500StatSVCCallingChannel OBJECT-TYPE SYNTAX DisplayString (SIZE(0..17)) ACCESS read-only STATUS mandatory DESCRIPTION "Calling channel of SVC." ::= { cdx6500StatSVCEntry 2 } cdx6500StatSVCCalledChannel OBJECT-TYPE SYNTAX DisplayString (SIZE(0..17)) ACCESS read-only STATUS mandatory DESCRIPTION "Called channel of SVC." ::= { cdx6500StatSVCEntry 3 } cdx6500StatSVCReverseCharge OBJECT-TYPE SYNTAX INTEGER { refuse (0), accept (1), newvalRefuse (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Reverse charge facility condition. refuse - Refused the condition. accept - Accepted the condition. newvalRefuse - same functionality as 'refuse', new enumeration added for RFC1155 compatibility." ::= { cdx6500StatSVCEntry 4 } cdx6500StatSVCFastSelect OBJECT-TYPE SYNTAX INTEGER { noFastSelect (0), fastSelect (1), newvalNoFastSelect (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Fast select facility condition. noFastSelect - Fast select facility is not selected. fastSelect - Fast select facility is selected. newvalNoFastSelect - same functionality as 'noFastSelect', new enumeration added for RFC1155 compatibility." ::= { cdx6500StatSVCEntry 5} cdx6500StatSVCNetUserIdentification OBJECT-TYPE SYNTAX INTEGER { notRequested (0), requested (1), newvalNotRequested (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Net user identifiaction facility condition. notRequested - Net user identifiaction facility not requested. requested - Net user identifiaction facility requested. newvalNotRequested - same functionality as 'notRequested', new enumeration added for RFC1155 compatibility." ::= { cdx6500StatSVCEntry 6} cdx6500StatSVCClosedUserGroup OBJECT-TYPE SYNTAX INTEGER { notRequested (0), requested (1), newvalNotRequested (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Closed user group facility on/off. notRequested - Closed user group facility off. requested - Closed user group facility on. newvalNotRequested - same functionality as 'notRequested', new enumeration added for RFC1155 compatibility." ::= { cdx6500StatSVCEntry 7} cdx6500StatSVCConnectionUPTime OBJECT-TYPE SYNTAX DisplayString (SIZE(0..21)) ACCESS read-only STATUS mandatory DESCRIPTION "Time at which connection was up." ::= { cdx6500StatSVCEntry 8} -- STAT module control parameter cdx6500statResetAllStats OBJECT-TYPE SYNTAX INTEGER { reset (1), noReset (2) } ACCESS write-only STATUS mandatory DESCRIPTION "A control object that when set to reset will cause the node to reset ALL its statistics. reset - reset ALL node statistics. noReset - Do not reset the statistics." ::= { cdx6500statControls 1 } -- Flash Control Group cdx6500ContFlashCopyImage OBJECT-TYPE SYNTAX INTEGER { currentToalternate (1), alternateTocurrent (2), noOperation (100) } ACCESS write-only STATUS mandatory DESCRIPTION "Copy image from current to alternate or alternate to current." ::= { cdx6500ContFlash 1 } cdx6500ContFlashCopyCmem OBJECT-TYPE SYNTAX INTEGER { currentToalternate (1), alternateTocurrent (2), noOperation (100) } ACCESS write-only STATUS mandatory DESCRIPTION "Copy cmem from current to alternate or alternate to current." ::= { cdx6500ContFlash 2 } cdx6500ContFlashActiveImage OBJECT-TYPE SYNTAX INTEGER { setcurrentImage (1), setalternateImage (2), noOperation (100) } ACCESS write-only STATUS mandatory DESCRIPTION "Activate image in flash memory." ::= { cdx6500ContFlash 3 } cdx6500ContFlashActiveCmem OBJECT-TYPE SYNTAX INTEGER { setcurrentCmem (1), setalternateCmem (2), noOperation (100) } ACCESS write-only STATUS mandatory DESCRIPTION "Activate cmem in flash memory." ::= { cdx6500ContFlash 4 } cdx6500ContFlashDeleteImage OBJECT-TYPE SYNTAX INTEGER { deleteImage (1), noOperation (100) } ACCESS write-only STATUS mandatory DESCRIPTION "Delete all images in flash memory." ::= { cdx6500ContFlash 5 } -- Control creating and station cdx6500CreatePortAndStationTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500CreatePortAndStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Create Port and Station table." ::= { cdx6500CfgProtocolGroup 9 } cdx6500CreatePortAndStationEntry OBJECT-TYPE SYNTAX Cdx6500CreatePortAndStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry for representing Creating Port and Station Record." INDEX {cdx6500PortNumber} ::= { cdx6500CreatePortAndStationTable 1 } Cdx6500CreatePortAndStationEntry ::= SEQUENCE { cdx6500PortNumber INTEGER, cdx6500CreatePortType INTEGER, cdx6500CreateStation INTEGER } cdx6500PortNumber OBJECT-TYPE SYNTAX INTEGER(1..256) ACCESS read-only STATUS mandatory DESCRIPTION "Port Number which is installed." ::= { cdx6500CreatePortAndStationEntry 1 } cdx6500CreatePortType OBJECT-TYPE SYNTAX INTEGER { pad (2), x25 (3), mx25 (9), sdlc (15), fri (17), xdlc (18), tr (28), eth (29), fra (33) } ACCESS write-only STATUS mandatory DESCRIPTION "port type to be created. pad : PAD port x25 : X25 port mx25 : Multipoint X25 port sdlc : Synchronous Data Link Control Port xdlc : X25 Data Link Control Port fri : Frame Relay Interface Port tr : Token Ring Port eth : Ethernet Port fra : Frame Relay Access Port." ::= { cdx6500CreatePortAndStationEntry 2 } cdx6500CreateStation OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "station number to be created. The instance should be existing port number. Station Range : 1 - Max Station Number." ::= { cdx6500CreatePortAndStationEntry 3 } -- The T3E3 Port Control Table cdx6500ContT3E3Table OBJECT IDENTIFIER ::= { cdx6500Controls 23 } cdx6500T3E3ContEntry OBJECT-TYPE SYNTAX Cdx6500T3E3ContEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each control applies to a single T3E3 port." INDEX { t3e3ContPortNumber } ::= { cdx6500ContT3E3Table 1 } Cdx6500T3E3ContEntry ::= SEQUENCE { t3e3ContPortNumber INTEGER, t3e3ContPortControl INTEGER } t3e3ContPortNumber OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "Port number of the T3E3 port." ::= { cdx6500T3E3ContEntry 1 } t3e3ContPortControl OBJECT-TYPE SYNTAX INTEGER { boot (1), enable (2), disable (3), resetstats (4) } ACCESS write-only STATUS mandatory DESCRIPTION "Control operations for the specified T3E3 port. boot - Boots the T3E3 port enable - Enables the T3E3 port disable - Disables the T3E3 port resetstats - Resets the T3E3 port statistics." ::= { cdx6500T3E3ContEntry 2 } END