SIEMENS-HP4KHIM-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Counter32, Integer32, IpAddress, Unsigned32 FROM SNMPv2-SMI MacAddress, DisplayString, TEXTUAL-CONVENTION FROM SNMPv2-TC OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF; siemens OBJECT IDENTIFIER ::= { enterprises 4329 } iandcAdmin OBJECT IDENTIFIER ::= { siemens 2 } hp4khim MODULE-IDENTITY LAST-UPDATED "200611100000Z" ORGANIZATION "Siemens" CONTACT-INFO "David Nemeskey" DESCRIPTION "" REVISION "200606070747Z" DESCRIPTION "Initial version." ::= { iandcAdmin 51 } HimPEN ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Octet String for storing PEN numbers. The format is The PEN is displayed in the following format: [LTG]-[LTU]-[EBT]. LTG: Line/Trunk Group: always 1 LTU: Line/Trunk Unit: a number between 1 and 99 EBT: a three-digit number." SYNTAX OCTET STRING (SIZE (0..9)) HimPabxId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Textual convention for the Pabx Id." SYNTAX Integer32 (1..2147483647) HimSwitchNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Data type of the switch number." SYNTAX OCTET STRING (SIZE (0..17)) HimYesNo ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Boolean data type: 1. no 2. yes The order is set like this to comply with the definition of data leaves in the hicom MIB that use this convention implicitly." SYNTAX INTEGER { yes(1), no(2), other(0) } DiscoveryStates ::= INTEGER { done(1), error(2), busy(3), finok(4), finerr(5), kill(6) } DiscoveryModes ::= INTEGER { man(1), auto(2), undef(9) } HimPhoneNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Convention that represents phone numbers in a HiPath system." SYNTAX OCTET STRING (SIZE (0..22)) HimShelfNWType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Network type of the shelf." SYNTAX INTEGER { flex(1), local(2), apnw(3), apdl(4), other(0) } -- Corresponds to the HIM Welcome Page himWelcomePage OBJECT IDENTIFIER ::= { hp4khim 1 } himWelPgTable OBJECT-TYPE SYNTAX SEQUENCE OF HimWelPgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himWelcomePage 1 } himWelPgEntry OBJECT-TYPE SYNTAX HimWelPgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himWelPgPabxId } ::= { himWelPgTable 1 } HimWelPgEntry ::= SEQUENCE { himWelPgPabxId HimPabxId, himWelPgSysNo HimSwitchNumber, himHP4KVersion OCTET STRING, himSystemRelease OCTET STRING, himRevisionLevel OCTET STRING, himHWArchitecture OCTET STRING, himHWArchitectureType OCTET STRING, himOperationMode OCTET STRING, himSWUProc1 OCTET STRING, himSWUMemory1 OCTET STRING, himSWUProc2 OCTET STRING, himSWUMemory2 OCTET STRING } himWelPgPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himWelPgEntry 1 } himWelPgSysNo OBJECT-TYPE SYNTAX HimSwitchNumber MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the system number (max. 17 characters)." ::= { himWelPgEntry 2 } himHP4KVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the Hicom/HiPath version number of the system (max. 4 characters)." ::= { himWelPgEntry 3 } himSystemRelease OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the system release number of the system (max. 2 characters)." ::= { himWelPgEntry 4 } himRevisionLevel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the revision number of the system software (max. 2 characters)." ::= { himWelPgEntry 5 } himHWArchitecture OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..25)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the information on hardware architecture in the format [hw-architecture][system-variant][hw-design] [hw-architecture] Abbreviation describing hardware architecture. F.i '4300', '350E', etc. [system-variant] H40: SYSTEM VARIANT 40 H80: SYSTEM VARIANT 80 H600: SYSTEM VARIANT 600 [hw-design] ECX: HARDWARE DESIGN EXTENDED COMPACT EXTENDED ECDSC: HARDWARE DESIGN EXTENDED COMPACT DSC CXE: HARDWARE DESIGN EXTENDED COMPACT CXE" ::= { himWelPgEntry 6 } himHWArchitectureType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains abbreviation describing hardware architecture type (max. 3 characters)." ::= { himWelPgEntry 7 } himOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..7)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the operating mode of the system. Possible Values: SIMPLEX: OPERATING MODE SIMPLEX DUPLEX: OPERATING MODE DUPLEX REDUNDANCY" ::= { himWelPgEntry 8 } himSWUProc1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "These fields contains the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-B" ::= { himWelPgEntry 9 } himSWUMemory1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "These fields contain the size of the SWU memory for each processor card. SWU = Switching Unit" ::= { himWelPgEntry 10 } himSWUProc2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "These fields contains the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-B" ::= { himWelPgEntry 11 } himSWUMemory2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "These fields contain the size of the SWU memory for each processor card. SWU = Switching Unit" ::= { himWelPgEntry 12 } himSwitchData OBJECT IDENTIFIER ::= { hp4khim 2 } himTechInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HimTechInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himSwitchData 1 } himTechInfoEntry OBJECT-TYPE SYNTAX HimTechInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himTechInfoPabxId, himTechInfoInfoNo } ::= { himTechInfoTable 1 } HimTechInfoEntry ::= SEQUENCE { himTechInfoPabxId HimPabxId, himTechInfoInfoNo OCTET STRING, himTechInfoDate OCTET STRING, himTechInfoTechnicalData OCTET STRING, himTechInfoNumber OCTET STRING, himTechInfoExtraText OCTET STRING } himTechInfoPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himTechInfoEntry 1 } himTechInfoInfoNo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..7)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of the subsystem. This number can be assigned as required when configuring the subsystem." ::= { himTechInfoEntry 2 } himTechInfoDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the date on which the subsystem was configured." ::= { himTechInfoEntry 3 } himTechInfoTechnicalData OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the technical data of the subsystem." ::= { himTechInfoEntry 4 } himTechInfoNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of each subsystem configured." ::= { himTechInfoEntry 5 } himTechInfoExtraText OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains additional text." ::= { himTechInfoEntry 6 } himNotepadDataTable OBJECT-TYPE SYNTAX SEQUENCE OF HimNotepadDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This node contains the system data entered in a notepad. The table for notepad entries holds a maximum of 30 data records." ::= { himSwitchData 2 } himNotepadDataEntry OBJECT-TYPE SYNTAX HimNotepadDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himNotepadDataPabxId, himNotepadDataInfoNo } ::= { himNotepadDataTable 1 } HimNotepadDataEntry ::= SEQUENCE { himNotepadDataPabxId HimPabxId, himNotepadDataInfoNo Unsigned32, himNotepadDataDate OCTET STRING, himNotepadDataText OCTET STRING } himNotepadDataPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himNotepadDataEntry 1 } himNotepadDataInfoNo OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of the subsystem. This number is assigned permanently when configuring the subsystem." ::= { himNotepadDataEntry 2 } himNotepadDataDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the date on which the subsystem was configured." ::= { himNotepadDataEntry 3 } himNotepadDataText OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..77)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the technical data of the subsystem." ::= { himNotepadDataEntry 4 } himProjPlanInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HimProjPlanInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This screen makes it possible to generate a file with project planning data." ::= { himSwitchData 3 } himProjPlanInfoEntry OBJECT-TYPE SYNTAX HimProjPlanInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himProjPlanPabxId } ::= { himProjPlanInfoTable 1 } HimProjPlanInfoEntry ::= SEQUENCE { himProjPlanPabxId HimPabxId, himProjPlanInfoFile OCTET STRING, himProjPlanInfoCreationDate OCTET STRING, himProjPlanInfoCreationTime OCTET STRING } himProjPlanPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himProjPlanInfoEntry 1 } himProjPlanInfoFile OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..12)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the project planning file." DEFVAL { "ProjPlan.txt" } ::= { himProjPlanInfoEntry 2 } himProjPlanInfoCreationDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the date on which the project planning file was generated." ::= { himProjPlanInfoEntry 3 } himProjPlanInfoCreationTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the time at which the project planning file was generated." ::= { himProjPlanInfoEntry 4 } himSpecSwitchData OBJECT IDENTIFIER ::= { hp4khim 3 } himSpecShelfDataTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSpecShelfDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All subscriber and trunk-related lines are grouped within LTU (Line/Trunk Unit) frames. Each frame has several slots for modules. The frame is connected to the system via the LTUC control board. This table contains the frame configuration." ::= { himSpecSwitchData 1 } himSpecShelfDataEntry OBJECT-TYPE SYNTAX HimSpecShelfDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSpecShelfDataPabxId, himSpecShelfDataAddress } ::= { himSpecShelfDataTable 1 } HimSpecShelfDataEntry ::= SEQUENCE { himSpecShelfDataPabxId HimPabxId, himSpecShelfDataAddress OCTET STRING, himSpecShelfDataFrameType OCTET STRING, himSpecShelfDataLTU INTEGER, himSpecShelfDataNetworkType HimShelfNWType, himSpecShelfDataNetworkAddress IpAddress, himSpecShelfDataRemote OCTET STRING, himSpecShelfDataLocation OCTET STRING, himSpecShelfDataLTUC OCTET STRING } himSpecShelfDataPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSpecShelfDataEntry 1 } himSpecShelfDataAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..9)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the address of the shelf in format LTG.LTU. LTG:Line/Trunk Group LTU: Line/Trunk Unit" ::= { himSpecShelfDataEntry 2 } himSpecShelfDataFrameType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the part number of the frame." ::= { himSpecShelfDataEntry 3 } himSpecShelfDataLTU OBJECT-TYPE SYNTAX INTEGER { preatl(1), cc40f(2), cc80w(3), cc80f(4), l80xf(5), l80xw(6), ltuw(7), inch19(8), ap37009(9), ap370013(10), ext-comp-x(11), other(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains type of LTU (Line/Trunk Unit) frame. Possible values for LTU frame type: - PREATL - frametype for Preatlantic Hicom Types - CC40F - basisframe for 40CMX - CC80W - basisframe for 80CMX - CC80F - basisframe for 80CMX/DSC and CXE - L80XF - for 80CMX/DSC, CXE, 600ECS and AP shelves - L80XW - extension frame for 80CMX/DSC - LTUW - frame for 600ECX and AP shelves Possible values for AP shelf type: - L80XF - for 80CMX/DSC, CXE, 600ECS and AP shelves - LTUW - frame for 600ECX and AP shelves - INCH19 - 19 inch frame for AP shelves" ::= { himSpecShelfDataEntry 4 } himSpecShelfDataNetworkType OBJECT-TYPE SYNTAX HimShelfNWType MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains connection type of LTU frame / AP shelf." ::= { himSpecShelfDataEntry 5 } himSpecShelfDataNetworkAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains network IP address." ::= { himSpecShelfDataEntry 6 } himSpecShelfDataRemote OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field shows if frame is remote. Possible values: - yes - frame is remote - no - frame is not remote" ::= { himSpecShelfDataEntry 7 } himSpecShelfDataLocation OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..48)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains postal address (city, street, building, ..) , where a FLEX LTU or an AP shelf is located." ::= { himSpecShelfDataEntry 8 } himSpecShelfDataLTUC OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..14)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains part number adding LTUC module. LTUC: Line/Trunk Unit Control." ::= { himSpecShelfDataEntry 9 } himSWUBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSWUBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the configuration of the peripheral boards. Periphery Assemblies Peripheral and ring generator assemblies as well as SIU are configured in the LTU. The board is entered in the SWU database. LTU = Line/Trunk Unit SIU = Signaling Interface Unit SWU = Switching Unit" ::= { himSpecSwitchData 2 } himSWUBoardEntry OBJECT-TYPE SYNTAX HimSWUBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSWUBoardPabxId, himSWUBoardPEN } ::= { himSWUBoardTable 1 } HimSWUBoardEntry ::= SEQUENCE { himSWUBoardPabxId HimPabxId, himSWUBoardPEN HimPEN, himSWUBoardOverlayLTU OCTET STRING, himSWUBoardType OCTET STRING, himSWUBoardNominal OCTET STRING, himSWUBoardActual OCTET STRING, hhimSWUBoardFirmware OCTET STRING, himSWUBoardRev OCTET STRING, himSWUBoardFunctId OCTET STRING, himSWUBoardMode OCTET STRING, himSWUBoardLWNo OCTET STRING, himSWUBoardLWInterVer OCTET STRING, himSWUBoardLWName OCTET STRING, himSWUBoardLWDate OCTET STRING } himSWUBoardPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSWUBoardEntry 1 } himSWUBoardPEN OBJECT-TYPE SYNTAX HimPEN MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the board PEN. PEN: Port Equipment Number The PEN is displayed in the following format: [LTG]-[LTU]-[EBT]. LTG: Line/Trunk Group LTU: Line/Trunk Unit EBT: Slot" ::= { himSWUBoardEntry 2 } himSWUBoardOverlayLTU OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the overlay LTU (Line/Trunk Unit)." ::= { himSWUBoardEntry 3 } himSWUBoardType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the configured board." ::= { himSWUBoardEntry 4 } himSWUBoardNominal OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the nominal board." ::= { himSWUBoardEntry 5 } himSWUBoardActual OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains part number of the board that is plugged in." ::= { himSWUBoardEntry 6 } hhimSWUBoardFirmware OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the firmware." ::= { himSWUBoardEntry 7 } himSWUBoardRev OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the revision of the board." ::= { himSWUBoardEntry 8 } himSWUBoardFunctId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "Function identification number for boards with more than one functions (e.g. SIUX, STMA, SLMO24)." ::= { himSWUBoardEntry 9 } himSWUBoardMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the mode of the board. The mode is only displayed for the RG/ACGEN board." ::= { himSWUBoardEntry 10 } himSWUBoardLWNo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of the loadware." ::= { himSWUBoardEntry 11 } himSWUBoardLWInterVer OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the interface version of the board." ::= { himSWUBoardEntry 12 } himSWUBoardLWName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the file name of the loadware file or of the initialization file." ::= { himSWUBoardEntry 13 } himSWUBoardLWDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the date on which the loadware or the initialization file was generated." ::= { himSWUBoardEntry 14 } himSWUPeriphery OBJECT IDENTIFIER ::= { hp4khim 4 } himPSIOAssTable OBJECT-TYPE SYNTAX SEQUENCE OF HimPSIOAssEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the PSIO assemblies data." ::= { himSWUPeriphery 1 } himPSIOAssEntry OBJECT-TYPE SYNTAX HimPSIOAssEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himPSIOAssPabxId, himPSIOAssPEN } ::= { himPSIOAssTable 1 } HimPSIOAssEntry ::= SEQUENCE { himPSIOAssPabxId HimPabxId, himPSIOAssPEN HimPEN, himPSIOAssAssembly OCTET STRING, himPSIOAssActual OCTET STRING, himPSIOAssFirmware OCTET STRING } himPSIOAssPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himPSIOAssEntry 1 } himPSIOAssAssembly OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the PSIO board. PSIO: Peripheral Serial Input Output" ::= { himPSIOAssEntry 3 } himPSIOAssPEN OBJECT-TYPE SYNTAX HimPEN MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the board PEN. PEN: Port Equipment Number The PEN is displayed in the following format: [LTG]-[LTU]-[EBT]. LTG: Line/Trunk Group LTU: Line/Trunk Unit EBT: Slot" ::= { himPSIOAssEntry 2 } himPSIOAssActual OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the part number of the PSIO board." ::= { himPSIOAssEntry 4 } himPSIOAssFirmware OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the firmware name of the PSIO board." ::= { himPSIOAssEntry 5 } himSerialLineTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSerialLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the serial interfaces data." ::= { himSWUPeriphery 2 } himSerialLineEntry OBJECT-TYPE SYNTAX HimSerialLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSerialLinePabxId, himSerialLineNumber } ::= { himSerialLineTable 1 } HimSerialLineEntry ::= SEQUENCE { himSerialLinePabxId HimPabxId, himSerialLineNumber Unsigned32, himSerialLineBoardType OCTET STRING, himSerialLineSpeed Unsigned32, himSerialLineLogDevName OCTET STRING, himSerialLineDevType OCTET STRING, himSerialLineType INTEGER } himSerialLinePabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSerialLineEntry 1 } himSerialLineBoardType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains abbreviation name of the board type." ::= { himSerialLineEntry 3 } himSerialLineNumber OBJECT-TYPE SYNTAX Unsigned32 (8..63) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the physical line number of the interface. Possible Values: numeric, 8-63" ::= { himSerialLineEntry 2 } himSerialLineSpeed OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains standardized transmission speed (baud rate). Possible Values: 50, 100, 200, 300, 600, 1200, 2400, 4800, 9600, 19200." ::= { himSerialLineEntry 4 } himSerialLineLogDevName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the logical device name of the line. Possible Values: Value - Description CON1 - LOGICAL DEVICE CONNECTION,TERMINAL 1 CON2 - LOGICAL DEVICE CONNECTION,TERMINAL 2 CON3 - LOGICAL DEVICE CONNECTION,TERMINAL 3 CON4 - LOGICAL DEVICE CONNECTION,TERMINAL 4 CON5 - LOGICAL DEVICE CONNECTION 5 CON6 - LOGICAL DEVICE CONNECTION 6 PR1 - LOGICAL DEVICE:LINE PRINTER 1 PR2 - LOGICAL DEVICE:LINE PRINTER 2 PR3 - LOGICAL DEVICE:LINE PRINTER 3 PR4 - LOGICAL DEVICE:LINE PRINTER 4" ::= { himSerialLineEntry 5 } himSerialLineDevType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..18)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the device type of the line. Possible Values: Value - Description PT88 - DEVICE TYPE QUOSC - QUME-ONLY-SCREEN QUOPT - QUME-ONLY-PT88 QUSCAPT - QUME-SCREEN-AND-PT88 PCOSC - PC-D-ONLY-SCREEN PCOPT - PC-D-ONLY-PT88 PCSCAPT - PC-D-SCREEN-AND-PT88 ASC - ASCII-CODE EBC - EBCDIC CODE RSV1 - RESERVED DEVICE TYPE 1 RSV2 - RESERVED DEVICE TYPE 2 RSV3 - RESERVED DEVICE TYPE 3" ::= { himSerialLineEntry 6 } himSerialLineType OBJECT-TYPE SYNTAX INTEGER { asy(1), v24(2), other(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the line type (operation of synchronous lines (terminals) connected via V24 modems). Possible values: - ASY: asynchronous line type - V24: ccitt rec v24" ::= { himSerialLineEntry 7 } himSCSIDevTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSCSIDevEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the data for the SCSI devices connected." ::= { himSWUPeriphery 3 } himSCSIDevEntry OBJECT-TYPE SYNTAX HimSCSIDevEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSCSIDevPabxId, himSCSIDevId } ::= { himSCSIDevTable 1 } HimSCSIDevEntry ::= SEQUENCE { himSCSIDevPabxId HimPabxId, himSCSIDevId Unsigned32, himSCSIDevType OCTET STRING, himSCSIDevName OCTET STRING, himSCSIDevFirmware OCTET STRING, himSCSIDevLoadDrive OCTET STRING } himSCSIDevPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSCSIDevEntry 1 } himSCSIDevId OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the type of SCSI device." ::= { himSCSIDevEntry 2 } himSCSIDevType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..13)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the SCSI ID of the device." ::= { himSCSIDevEntry 3 } himSCSIDevName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..25)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the SCSI device in format: [vendor] [product number]." ::= { himSCSIDevEntry 4 } himSCSIDevFirmware OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the firmware name of the SCSI device." ::= { himSCSIDevEntry 5 } himSCSIDevLoadDrive OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field displays (if activity is in progress) the device from which the operating system and the database are started." ::= { himSCSIDevEntry 6 } himCentralSwitchData OBJECT IDENTIFIER ::= { hp4khim 5 } himCabinetTable OBJECT-TYPE SYNTAX SEQUENCE OF HimCabinetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the data for configuring the cabinets and frames in a system. They reflect the physical structure of the system." ::= { himCentralSwitchData 1 } himCabinetEntry OBJECT-TYPE SYNTAX HimCabinetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himCabPabxId, himCabAddr } ::= { himCabinetTable 1 } HimCabinetEntry ::= SEQUENCE { himCabPabxId HimPabxId, himCabAddr OCTET STRING, himCabPhysAddr OCTET STRING, himCabCabinet OCTET STRING, himCabPartNo OCTET STRING, himCabShelfNo Unsigned32, himCabFrame OCTET STRING, himCabPid1 OCTET STRING, himCabPid2 OCTET STRING, himCabPid3 OCTET STRING, himCabLTUNo OCTET STRING } himCabPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himCabinetEntry 1 } himCabAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the cabinet address. Structure of cabinet address: P 1 01 | | |__Number of cabinet in cabinet row | |_____Units, position of cabinet row |_______Tens (P=0, Q=1), position of the cabinet" ::= { himCabinetEntry 2 } himCabPhysAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himCabinetEntry 3 } himCabCabinet OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the cabinet." ::= { himCabinetEntry 4 } himCabPartNo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..14)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the part number of the cabinet." ::= { himCabinetEntry 5 } himCabShelfNo OBJECT-TYPE SYNTAX Unsigned32 (1..14) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of the shelf." ::= { himCabinetEntry 6 } himCabFrame OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the frame." ::= { himCabinetEntry 7 } himCabPid1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the processor ID 1." ::= { himCabinetEntry 8 } himCabPid2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the processor ID 2." ::= { himCabinetEntry 9 } himCabPid3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the processor ID 2." ::= { himCabinetEntry 10 } himCabLTUNo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of the LTU (Line/Trunk Unit). The LTU range is divided in two parts: HHS (HICOM Host System) and AP (Access Point). The available values of the ranges are: HHS 1-15 and AP 17-99. The LTU 16 is forbidden. There are existing shelfes which are allowed only in HHS and others which are allowed only in the AP range." ::= { himCabinetEntry 11 } himMemScalingTable OBJECT-TYPE SYNTAX SEQUENCE OF HimMemScalingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This screen contains the memory parameters for each of the devices or features specified. The values are only displayed in Configuration Management. See also DIMSU parameter list." ::= { himCentralSwitchData 2 } himMemScalingEntry OBJECT-TYPE SYNTAX HimMemScalingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himMemScalingPabxId, himMemScalingUnit } ::= { himMemScalingTable 1 } HimMemScalingEntry ::= SEQUENCE { himMemScalingPabxId HimPabxId, himMemScalingUnit OCTET STRING, himMemScalingUsed Integer32, himMemScalingMaxUsed Integer32, himMemScalingAllocated Integer32, himMemScalingStandard Integer32, himMemScalingSysMax Integer32 } himMemScalingPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himMemScalingEntry 1 } himMemScalingUnit OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the parameter name (AMO DIMSU)." ::= { himMemScalingEntry 2 } himMemScalingUsed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value specifies the number of memory elements already used up. The comparison with the value in the Maximum field indicates how much of the allocated memory is still available for configuring devices or features." ::= { himMemScalingEntry 3 } himMemScalingMaxUsed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of memory elements allocated." ::= { himMemScalingEntry 4 } himMemScalingAllocated OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field displays the maximum number of memory elements that once have been used up during the lifetime of the switch ('high water mark'). It gives an indication how much memory was necessary at one time, so it is advised to not reduce the Maximum value below this value." ::= { himMemScalingEntry 5 } himMemScalingStandard OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Standard is the advised value to be set in the Maximum field, if you don't have special needs to set it to a specific value. If you set all devices and features to the standard values it is guaranteed that you don't run out of DIMSU memory." ::= { himMemScalingEntry 6 } himMemScalingSysMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the maximum number of possible memory elements." ::= { himMemScalingEntry 7 } himGeneralSwitchData OBJECT IDENTIFIER ::= { hp4khim 6 } himDBConfSys OBJECT IDENTIFIER ::= { himGeneralSwitchData 1 } himDBConfSysTable OBJECT-TYPE SYNTAX SEQUENCE OF HimDBConfSysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himDBConfSys 1 } himDBConfSysEntry OBJECT-TYPE SYNTAX HimDBConfSysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himDBConfSysPabxId } ::= { himDBConfSysTable 1 } HimDBConfSysEntry ::= SEQUENCE { himDBConfSysPabxId HimPabxId, himDBConfSysClass1 OCTET STRING, himDBConfSysClass2 OCTET STRING, himDBConfSysHWAss1 OCTET STRING, himDBConfSysHWAss2 OCTET STRING, himDBConfSysDevLine1 OCTET STRING, himDBConfSysDevLine2 OCTET STRING, himDBConfSysOpMode INTEGER, himDBConfSysResType OCTET STRING, himDBConfSysHWArch OCTET STRING, himDBConfSysHWArchType OCTET STRING, himDBConfSysNo HimSwitchNumber, himDBConfSysLoc INTEGER, himDBConfSysBaseApp OCTET STRING, himDBConfSysDBApp OCTET STRING, himDBConfSysID OCTET STRING } himDBConfSysPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himDBConfSysEntry 1 } himDBConfSysClass1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..12)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the system." ::= { himDBConfSysEntry 2 } himDBConfSysClass2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the coded name of the system." ::= { himDBConfSysEntry 3 } himDBConfSysHWAss1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the hardware ID of the system." ::= { himDBConfSysEntry 4 } himDBConfSysHWAss2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..7)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the shortened hardware ID of the system." ::= { himDBConfSysEntry 5 } himDBConfSysDevLine1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..18)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the product line." ::= { himDBConfSysEntry 6 } himDBConfSysDevLine2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the shortened name of the product line. Possible values: - H300: EUROPE DEVELOPMENT - HUSA: US DEVELOPMENT" ::= { himDBConfSysEntry 7 } himDBConfSysOpMode OBJECT-TYPE SYNTAX INTEGER { simplex(1), duplex(2), other(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the operating mode of the system. Possible Values: - SIMPLEX: OPERATING MODE SIMPLEX - DUPLEX: OPERATING MODE DUPLEX REDUNDANCY" ::= { himDBConfSysEntry 8 } himDBConfSysResType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the restart identifier." ::= { himDBConfSysEntry 9 } himDBConfSysHWArch OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the hardware architecture." ::= { himDBConfSysEntry 10 } himDBConfSysHWArchType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the hardware architecture type." ::= { himDBConfSysEntry 11 } himDBConfSysNo OBJECT-TYPE SYNTAX HimSwitchNumber MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of the system." ::= { himDBConfSysEntry 12 } himDBConfSysLoc OBJECT-TYPE SYNTAX INTEGER { customer(1), support(2), testlab(3), other(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the location in which the system is installed. Possible Values: - CUSTOMER (customer) - SUPPORT (support) - TESTLAB (testlab)" ::= { himDBConfSysEntry 13 } himDBConfSysBaseApp OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the base application." ::= { himDBConfSysEntry 14 } himDBConfSysDBApp OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the database application." ::= { himDBConfSysEntry 15 } himDBConfSysID OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the system identification." ::= { himDBConfSysEntry 16 } himDBConfHW OBJECT IDENTIFIER ::= { himGeneralSwitchData 2 } himDBConfHWTable OBJECT-TYPE SYNTAX SEQUENCE OF HimDBConfHWEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himDBConfHW 1 } himDBConfHWEntry OBJECT-TYPE SYNTAX HimDBConfHWEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himDBConfHWPabxId } ::= { himDBConfHWTable 1 } HimDBConfHWEntry ::= SEQUENCE { himDBConfHWPabxId HimPabxId, himDBConfHWLTG Integer32, himDBConfHWLTU Integer32, himDBConfHWLines Integer32, himDBConfHWPorts Integer32, himDBConfHWPBC Integer32, himDBConfHWMTSBdPerGSN Integer32, himDBConfHWSIUPPerLTU Integer32, himDBConfHWDIUCPerLTU Integer32, himDBConfHWHwyPerMTSBd Integer32, himDBConfHWHDLCPerDCL Integer32, himDBConfHWPBCPerDCL Integer32, himDBConfHWStdSIULine Integer32, himDBConfHWConfLine Integer32, himDBConfHWDBDim OCTET STRING, himDBConfHWTableVer Integer32 } himDBConfHWPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himDBConfHWEntry 1 } --Originally OCTET_STRING (SIZE (0..2)) himDBConfHWLTG OBJECT-TYPE SYNTAX Integer32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of LTGs in the system. LTG: Line/Trunk Group" ::= { himDBConfHWEntry 2 } --Originally OCTET_STRING (SIZE (0..2)) himDBConfHWLTU OBJECT-TYPE SYNTAX Integer32 (1..15 | 17..99) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of LTUs in the system. LTU: Line/Trunk Unit" ::= { himDBConfHWEntry 3 } --Originally OCTET_STRING (SIZE (0..5)) himDBConfHWLines OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of lines in the system." ::= { himDBConfHWEntry 4 } --Originally OCTET_STRING (SIZE (0..5)) himDBConfHWPorts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of ports in the system." ::= { himDBConfHWEntry 5 } --Originally OCTET_STRING (SIZE (0..2)) himDBConfHWPBC OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of peripheral board controllers (PBC) in the system." ::= { himDBConfHWEntry 6 } --Originally OCTET_STRING (SIZE (0..3)) himDBConfHWMTSBdPerGSN OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of memory time switches (MTS) per group switching network (GSN)." ::= { himDBConfHWEntry 7 } --Originally OCTET_STRING (SIZE (0..2)) himDBConfHWSIUPPerLTU OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of SIUP boards per LTU (Line/Trunk Unit)." ::= { himDBConfHWEntry 8 } --Originally OCTET_STRING (SIZE (0..2)) himDBConfHWDIUCPerLTU OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of DIUC boards per LTU (Line/Trunk Unit)." ::= { himDBConfHWEntry 9 } --Originally OCTET_STRING (SIZE (0..3)) himDBConfHWHwyPerMTSBd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number highways (HYW) per MTS board." ::= { himDBConfHWEntry 10 } --Originally OCTET_STRING (SIZE (0..2)) himDBConfHWHDLCPerDCL OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of high level data link control (HDLC) channels per data communication link (DCL)." ::= { himDBConfHWEntry 11 } --Originally OCTET_STRING (SIZE (0..2)) himDBConfHWPBCPerDCL OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of peripheral board controllers (PBC) per data communication link (DCL)." ::= { himDBConfHWEntry 12 } --Originally OCTET_STRING (SIZE (0..4)) himDBConfHWStdSIULine OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of signaling unit lines. SIU: Signaling-Unit" ::= { himDBConfHWEntry 13 } --Originally OCTET_STRING (SIZE (0..4)) himDBConfHWConfLine OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of lines in the CONFERENCE board." ::= { himDBConfHWEntry 14 } himDBConfHWDBDim OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the database dimensioning." ::= { himDBConfHWEntry 15 } --Originally OCTET_STRING (SIZE (0..3)) himDBConfHWTableVer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the version of the Conf table." ::= { himDBConfHWEntry 16 } himHWData OBJECT IDENTIFIER ::= { himGeneralSwitchData 3 } himHWDataTable OBJECT-TYPE SYNTAX SEQUENCE OF HimHWDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himHWData 1 } himHWDataEntry OBJECT-TYPE SYNTAX HimHWDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himHWDataPabxId } ::= { himHWDataTable 1 } HimHWDataEntry ::= SEQUENCE { himHWDataPabxId HimPabxId, himHWArch OCTET STRING, himHWArchType OCTET STRING, himHWOpMode OCTET STRING, himHWSWUProc1 OCTET STRING, himHWSWUMem1 OCTET STRING, himHWSWUProc2 OCTET STRING, himHWSWUMem2 OCTET STRING, himHWADPProc OCTET STRING, himHWADPMem OCTET STRING } himHWDataPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himHWDataEntry 1 } himHWArch OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..25)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the hardware architecture." REFERENCE "Same as himDBConfSysHWArch." ::= { himHWDataEntry 2 } himHWArchType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the hardware architecture type." REFERENCE "Same as himDBConfSysHWArchType." ::= { himHWDataEntry 3 } himHWOpMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..7)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the operating mode." REFERENCE "Should be the same as himDBConfSysOpMode." ::= { himHWDataEntry 4 } himHWSWUProc1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "These fields contain the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-B " ::= { himHWDataEntry 5 } himHWSWUMem1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "These fields contain the size of the SWU memory for each processor board. SWU = Switching Unit" ::= { himHWDataEntry 6 } himHWSWUProc2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "These fields contain the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-B " ::= { himHWDataEntry 7 } himHWSWUMem2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "These fields contain the size of the SWU memory for each processor board. SWU = Switching Unit" ::= { himHWDataEntry 8 } himHWADPProc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the ADP processor." ::= { himHWDataEntry 9 } himHWADPMem OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the size of memory used by the ADP." ::= { himHWDataEntry 10 } himLWDataOnCB OBJECT IDENTIFIER ::= { himGeneralSwitchData 4 } himLWDataOnCBTable OBJECT-TYPE SYNTAX SEQUENCE OF HimLWDataOnCBEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himLWDataOnCB 1 } himLWDataOnCBEntry OBJECT-TYPE SYNTAX HimLWDataOnCBEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himLWDataOnCBPabxId } ::= { himLWDataOnCBTable 1 } HimLWDataOnCBEntry ::= SEQUENCE { himLWDataOnCBPabxId HimPabxId, himLWOnCBAss OCTET STRING, himLWOnCBPBCAddr OCTET STRING, himLWOnCBFileName OCTET STRING, himLWOnCBProdTime OCTET STRING } himLWDataOnCBPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himLWDataOnCBEntry 1 } himLWOnCBAss OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the hardware ID of the board. Note: Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty." ::= { himLWDataOnCBEntry 2 } himLWOnCBPBCAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the peripheral board controller (PBC) address of the module. Note: Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty." ::= { himLWDataOnCBEntry 3 } himLWOnCBFileName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the filename of the loadware file. Note: Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty." ::= { himLWDataOnCBEntry 4 } himLWOnCBProdTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the production date of the loadware. Note:Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty." ::= { himLWDataOnCBEntry 5 } himLWDataOnProc OBJECT IDENTIFIER ::= { himGeneralSwitchData 5 } himLWOnProcTable OBJECT-TYPE SYNTAX SEQUENCE OF HimLWOnProcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himLWDataOnProc 1 } himLWOnProcEntry OBJECT-TYPE SYNTAX HimLWOnProcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himLWOnProcPabxId, himLWOnProcAss, himLWOnProcInfoType } ::= { himLWOnProcTable 1 } HimLWOnProcEntry ::= SEQUENCE { himLWOnProcPabxId HimPabxId, himLWOnProcAss OCTET STRING, himLWOnProcInfoType OCTET STRING, himLWOnProcLWId OCTET STRING, himLWOnProcLWIdCMP OCTET STRING, himLWOnProcLWIdLP OCTET STRING } himLWOnProcPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himLWOnProcEntry 1 } himLWOnProcAss OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the directory where the file with information on Loadware resides, e. g. CCA, CCB or ADP (max. 3 characters)." ::= { himLWOnProcEntry 2 } himLWOnProcInfoType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the boot type. It represents the file name also." ::= { himLWOnProcEntry 3 } himLWOnProcLWId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the loadware." ::= { himLWOnProcEntry 4 } himLWOnProcLWIdCMP OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the loadware ID for the CMP. This field contains the '-' character if it is not relevant to this board." ::= { himLWOnProcEntry 5 } himLWOnProcLWIdLP OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the loadware ID for the LP. This field contains the '-' character if it is not relevant to this board." ::= { himLWOnProcEntry 6 } himLWDataOnCSIU OBJECT IDENTIFIER ::= { himGeneralSwitchData 6 } himLWOnCSIUTable OBJECT-TYPE SYNTAX SEQUENCE OF HimLWOnCSIUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the loadware data on the central SIU (Signaling Interface Unit)." ::= { himLWDataOnCSIU 1 } himLWOnCSIUEntry OBJECT-TYPE SYNTAX HimLWOnCSIUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himLWOnCSIUPabxId, himLWOnCSIUNominal, himLWOnCSIULWNo } ::= { himLWOnCSIUTable 1 } HimLWOnCSIUEntry ::= SEQUENCE { himLWOnCSIUPabxId HimPabxId, himLWOnCSIUNominal OCTET STRING, himLWOnCSIULWNo OCTET STRING, himLWOnCSIUProc OCTET STRING, himLWOnCSIUSlot OCTET STRING, himLWOnCSIUActual OCTET STRING, himLWOnCSIUFileName OCTET STRING, himLWOnCSIUFileProd OCTET STRING } himLWOnCSIUPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himLWOnCSIUEntry 1 } himLWOnCSIUNominal OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..14)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the nominal SIU (Signaling Interface Unit)." ::= { himLWOnCSIUEntry 2 } himLWOnCSIULWNo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the SIU (Signaling Interface Unit) loadware." ::= { himLWOnCSIUEntry 3 } himLWOnCSIUProc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the processor in the SIU (Signaling Interface Unit)." ::= { himLWOnCSIUEntry 4 } himLWOnCSIUSlot OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the SIU (Signaling Interface Unit) slot." ::= { himLWOnCSIUEntry 5 } himLWOnCSIUActual OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..14)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the current SIU (Signaling Interface Unit)." ::= { himLWOnCSIUEntry 6 } himLWOnCSIUFileName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the file name of the loadware file or of the initialization file." ::= { himLWOnCSIUEntry 7 } himLWOnCSIUFileProd OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the date on which the loadware or the initialization file was generated." ::= { himLWOnCSIUEntry 8 } himMacAddress OBJECT IDENTIFIER ::= { himGeneralSwitchData 7 } himMacAddrTable OBJECT-TYPE SYNTAX SEQUENCE OF HimMacAddrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the C-LAN and IPDA MAC addresses which are read during the boot process." ::= { himMacAddress 1 } himMacAddrEntry OBJECT-TYPE SYNTAX HimMacAddrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himMacAddrPabxId, himMacAddrProc, himMacAddrInfoType } ::= { himMacAddrTable 1 } HimMacAddrEntry ::= SEQUENCE { himMacAddrPabxId HimPabxId, himMacAddrProc OCTET STRING, himMacAddrInfoType OCTET STRING, himMacAddrCLan MacAddress, himMacAddrIPDA MacAddress } himMacAddrPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himMacAddrEntry 1 } himMacAddrProc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the processor (CCA, CCB or ADP - max 3 characters). It is also the name of the Unix directory where the file with information on MAC address resides." ::= { himMacAddrEntry 2 } himMacAddrInfoType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the condition on which the mac addresses are available." ::= { himMacAddrEntry 3 } himMacAddrCLan OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the MAC address for UW7 part. The format is following: 'xx xx xx xx xx xx'." ::= { himMacAddrEntry 4 } himMacAddrIPDA OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the MAC address for RMX part. The format is following: 'xx xx xx xx xx xx'." ::= { himMacAddrEntry 5 } himFeatures OBJECT IDENTIFIER ::= { hp4khim 7 } himMarketingFeatures OBJECT IDENTIFIER ::= { himFeatures 1 } himMarkFeatTable OBJECT-TYPE SYNTAX SEQUENCE OF HimMarkFeatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himMarketingFeatures 1 } himMarkFeatEntry OBJECT-TYPE SYNTAX HimMarkFeatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himMarkFeatPabxId } ::= { himMarkFeatTable 1 } HimMarkFeatEntry ::= SEQUENCE { himMarkFeatPabxId HimPabxId, himMarkFeatVer OCTET STRING, himMarkFeatSerNo OCTET STRING, himMarkFeatHWId OCTET STRING, himMarkFeatInstallDate OCTET STRING, himMarkFeatExpiryDate OCTET STRING, himMarkFeatConfCode OCTET STRING, himMarkFeatTrialModeAct HimYesNo, himMarkFeatTrialRemDays Integer32 } himMarkFeatPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himMarkFeatEntry 1 } himMarkFeatVer OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the version of the software package. Format explanation: H 2 04 | |__SW version (01=EV1.0; 02=EV2.0; 03=EV3.0; 04=HiPath 4000 V1.0; 05=HiPath 4000 V2.0; 06=HiPath 4000 V3.0) | |_____Marketing concept (1=Old, 2=New)" ::= { himMarkFeatEntry 2 } himMarkFeatSerNo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the serial number of the software package." ::= { himMarkFeatEntry 3 } himMarkFeatHWId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the dongle ID of the hardware dongle connected." ::= { himMarkFeatEntry 4 } himMarkFeatInstallDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the date on which the code word was entered." ::= { himMarkFeatEntry 5 } himMarkFeatExpiryDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the date on which the code word will expire." ::= { himMarkFeatEntry 6 } himMarkFeatConfCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains codeword entry confirmation code." ::= { himMarkFeatEntry 7 } himMarkFeatTrialModeAct OBJECT-TYPE SYNTAX HimYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "This field shows whether trial mode is active. Possible values: - yes - trial mode is activated - no - trial mode is not activated" ::= { himMarkFeatEntry 8 } himMarkFeatTrialRemDays OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains number of remaining days of an active trial mode." ::= { himMarkFeatEntry 9 } himSalesFeatTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSalesFeatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himMarketingFeatures 2 } himSalesFeatEntry OBJECT-TYPE SYNTAX HimSalesFeatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSalesFeatPabxId, himSalesFeatMarketPackId } ::= { himSalesFeatTable 1 } HimSalesFeatEntry ::= SEQUENCE { himSalesFeatPabxId HimPabxId, himSalesFeatMarketPackId OCTET STRING, himSalesFeatMarketPack OCTET STRING, himSalesFeatContract OCTET STRING, himSalesFeatUsed OCTET STRING, himSalesFeatFree OCTET STRING, himSalesFeatMarkForTrial OCTET STRING } himSalesFeatPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSalesFeatEntry 1 } himSalesFeatMarketPackId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This column contains the CM ids of the marketing packages." ::= { himSalesFeatEntry 2 } himSalesFeatMarketPack OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..50)) MAX-ACCESS read-only STATUS current DESCRIPTION "This column contains the names of the marketing packages." ::= { himSalesFeatEntry 3 } himSalesFeatContract OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This column indicates whether the marketing packages have been purchased." ::= { himSalesFeatEntry 4 } himSalesFeatUsed OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This column indicates whether the marketing packages have been used." ::= { himSalesFeatEntry 5 } himSalesFeatFree OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of free packages." ::= { himSalesFeatEntry 6 } himSalesFeatMarkForTrial OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of packages (entites) marked for trial or blocked (if the trial mode is not active)." ::= { himSalesFeatEntry 7 } himTechFeatures OBJECT IDENTIFIER ::= { himFeatures 2 } himTechFeatTable OBJECT-TYPE SYNTAX SEQUENCE OF HimTechFeatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himTechFeatures 1 } himTechFeatEntry OBJECT-TYPE SYNTAX HimTechFeatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains all enabled and disabled customer-specific features. Use the Object List view to display a list of all features availavle." INDEX { himTechFeatPabxId, himTechFeatId } ::= { himTechFeatTable 1 } HimTechFeatEntry ::= SEQUENCE { himTechFeatPabxId HimPabxId, himTechFeatId OCTET STRING, himTechFeatName OCTET STRING, himTechFeatState HimYesNo } himTechFeatPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himTechFeatEntry 1 } himTechFeatId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the CM id of the customer-specific feature." ::= { himTechFeatEntry 2 } himTechFeatName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..70)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the customer-specific feature." ::= { himTechFeatEntry 3 } himTechFeatState OBJECT-TYPE SYNTAX HimYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the status of the customer-specific feature." ::= { himTechFeatEntry 4 } himAPSPatches OBJECT IDENTIFIER ::= { hp4khim 8 } himSwitchAPS OBJECT IDENTIFIER ::= { himAPSPatches 1 } himSwitchAPSTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSwitchAPSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himSwitchAPS 1 } himSwitchAPSEntry OBJECT-TYPE SYNTAX HimSwitchAPSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSwitchAPSPabxId, himSwitchAPSName } ::= { himSwitchAPSTable 1 } HimSwitchAPSEntry ::= SEQUENCE { himSwitchAPSPabxId HimPabxId, himSwitchAPSName OCTET STRING, himSwitchAPSCorrVer OCTET STRING, himSwitchAPSPartNo OCTET STRING } himSwitchAPSPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSwitchAPSEntry 1 } himSwitchAPSName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSwitchAPSEntry 2 } himSwitchAPSCorrVer OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSwitchAPSEntry 3 } himSwitchAPSPartNo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSwitchAPSEntry 4 } himReplacedAMOs OBJECT IDENTIFIER ::= { himAPSPatches 2 } himReplAMOTable OBJECT-TYPE SYNTAX SEQUENCE OF HimReplAMOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table displays those AMOs that have been changed since the last system correction version." ::= { himReplacedAMOs 1 } himReplAMOEntry OBJECT-TYPE SYNTAX HimReplAMOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himReplAMOPabxId, himReplAMOAPS, himReplAMOName } ::= { himReplAMOTable 1 } HimReplAMOEntry ::= SEQUENCE { himReplAMOPabxId HimPabxId, himReplAMOAPS OCTET STRING, himReplAMOName OCTET STRING, himReplAMOInAPSDir OCTET STRING, himReplAMOSubsystem OCTET STRING } himReplAMOPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himReplAMOEntry 1 } himReplAMOAPS OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The APS in which the change has been made." ::= { himReplAMOEntry 2 } himReplAMOName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the AMO command." ::= { himReplAMOEntry 3 } himReplAMOInAPSDir OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the subsystem in the DIR file." ::= { himReplAMOEntry 4 } himReplAMOSubsystem OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the current subsystem." ::= { himReplAMOEntry 5 } himPatchInfo OBJECT IDENTIFIER ::= { himAPSPatches 3 } himPatchInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HimPatchInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information on the software patches that have been implemented." ::= { himPatchInfo 1 } himPatchInfoEntry OBJECT-TYPE SYNTAX HimPatchInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himPatchInfoPabxId, himPatchInfoPatchNo } ::= { himPatchInfoTable 1 } HimPatchInfoEntry ::= SEQUENCE { himPatchInfoPabxId HimPabxId, himPatchInfoPatchNo OCTET STRING, himPatchInfoPatchGroup OCTET STRING, himPatchInfoOpt HimYesNo, himPatchInfoActHD OCTET STRING, himPatchInfoActADP OCTET STRING, himPatchInfoActBP OCTET STRING } himPatchInfoPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himPatchInfoEntry 1 } himPatchInfoPatchNo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..12)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the number of the patch." ::= { himPatchInfoEntry 2 } himPatchInfoPatchGroup OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the patch group." ::= { himPatchInfoEntry 3 } himPatchInfoOpt OBJECT-TYPE SYNTAX HimYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "This field represents an indicator that the patch is: - optional: not part of patch packet, - not optional: a part of patch packet (represents the whole list of internal activated/deactivated patches). The purpose of this field is to give user an option to display all patches as well as only optional ones." ::= { himPatchInfoEntry 4 } himPatchInfoActHD OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field indicates whether the patch is enabled on the hard disk." ::= { himPatchInfoEntry 5 } himPatchInfoActADP OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field indicates whether the patch is enabled on the ADP." ::= { himPatchInfoEntry 6 } himPatchInfoActBP OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field indicates whether the patch is enabled on the A/B processor." ::= { himPatchInfoEntry 7 } himSWVersion OBJECT IDENTIFIER ::= { hp4khim 9 } himSWVerOnProcTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSWVerOnProcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains data on the software versions loaded on the processor boards." ::= { himSWVersion 1 } himSWVerOnProcEntry OBJECT-TYPE SYNTAX HimSWVerOnProcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSWVerOnProcPabxId, himSWVerOnProcSrc } ::= { himSWVerOnProcTable 1 } HimSWVerOnProcEntry ::= SEQUENCE { himSWVerOnProcPabxId HimPabxId, himSWVerOnProcSrc OCTET STRING, himSWVerOnProcSWVer OCTET STRING, himSWVerOnProcItemCodeNoPrefix OCTET STRING, himSWVerOnProcHP4KVer OCTET STRING, himSWVerOnProcSysRel OCTET STRING, himSWVerOnProcCountry OCTET STRING, himSWVerOnProcCountryCode OCTET STRING, himSWVerOnProcRevNo OCTET STRING } himSWVerOnProcPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSWVerOnProcEntry 1 } himSWVerOnProcSrc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the software source." ::= { himSWVerOnProcEntry 2 } himSWVerOnProcSWVer OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..17)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the software version of the ADP software. The software version is displayed in the following format: [item-code-prefix][hipath-version][release-no][country-id][country-code][revision-no] e. g. P30252N 43 08 B 000 10" ::= { himSWVerOnProcEntry 3 } himSWVerOnProcItemCodeNoPrefix OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the prefix of the software." ::= { himSWVerOnProcEntry 4 } himSWVerOnProcHP4KVer OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the Hicom/HiPath version." ::= { himSWVerOnProcEntry 5 } himSWVerOnProcSysRel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the system release number." ::= { himSWVerOnProcEntry 6 } himSWVerOnProcCountry OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the country identifier." ::= { himSWVerOnProcEntry 7 } himSWVerOnProcCountryCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the country encoding." ::= { himSWVerOnProcEntry 8 } himSWVerOnProcRevNo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the revision number of the ADP software." ::= { himSWVerOnProcEntry 9 } himSwPkgVersion OBJECT IDENTIFIER ::= { hp4khim 10 } himSWPkgVerTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSWPkgVerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the software versions of the service functions. This data is retrieved using the UNIX command pgkinfo -l." ::= { himSwPkgVersion 1 } himSWPkgVerEntry OBJECT-TYPE SYNTAX HimSWPkgVerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSWPkgVerPabxId, himSWPkgVerPkgAbbr } ::= { himSWPkgVerTable 1 } HimSWPkgVerEntry ::= SEQUENCE { himSWPkgVerPabxId HimPabxId, himSWPkgVerPkgAbbr OCTET STRING, himSWPkgVerPkgName OCTET STRING, himSWPkgVerVersion OCTET STRING, himSWPkgVerInstAt OCTET STRING, himSWPkgVerStatus INTEGER } himSWPkgVerPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSWPkgVerEntry 1 } himSWPkgVerPkgAbbr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the abbreviation of the software package." ::= { himSWPkgVerEntry 2 } himSWPkgVerPkgName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..50)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the software package." ::= { himSWPkgVerEntry 3 } himSWPkgVerVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the version of the software package." ::= { himSWPkgVerEntry 4 } himSWPkgVerInstAt OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the date on which the software package was installed." ::= { himSWPkgVerEntry 5 } himSWPkgVerStatus OBJECT-TYPE SYNTAX INTEGER { partial(1), complete(2), other(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the status of the software package." ::= { himSWPkgVerEntry 6 } himSystem OBJECT IDENTIFIER ::= { hp4khim 11 } himSysBasicTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSysBasicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table complements the information about the HiPath 4000 system that is stored in the hicomSystem branch of the hicom MIB." ::= { himSystem 1 } himSysBasicEntry OBJECT-TYPE SYNTAX HimSysBasicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSysBasicPabxId } ::= { himSysBasicTable 1 } HimSysBasicEntry ::= SEQUENCE { himSysBasicPabxId HimPabxId, himSysBasicDomain OCTET STRING, himSysBasicNodeNo OCTET STRING, himSysBasicLEGK HimYesNo } himSysBasicPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSysBasicEntry 1 } himSysBasicDomain OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This field contains the name of the domain to which the system is belonging." ::= { himSysBasicEntry 2 } himSysBasicNodeNo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "HiPath node number. This field contains the globally unique number of your own PABX. This has a hierarchical structure containing different levels in Version V1.0 and later. Up to three values of the format: L2- L1- L0 can be used for numbering a system. - L2: area number in level 2 - L1: area number in level 1 - L0: area number in level 0 or node number in the old sense. If the value '0' is selected for a level, this means that the relevant hierarchical level is not being used for node numbering: '0' is equal to 'nothing' or 'level is not set'. With the help of this new node number format it is now possible to implement node numbers in networks in which - just as with dial numbers - the network hierarchy is reflected in the node numbers. The same numbering level (= number of levels set in the node number) must be used for all nodes in a network. This field will always show a three-level display with leading zeroes for levels not used for systems in Version V1.0 and later. Example: - 0-0-100 for 1-level numbering - 0-1-101 for 2-level numbering - 1-2-300 for 3-level numbering Values: 0-9 and '-' with format 22-111-000 Level 0 (000) 0-999 Level 1 (111) 0-253 Level 2 (22) 0-29 Max. 10 digits" ::= { himSysBasicEntry 3 } himSysBasicLEGK OBJECT-TYPE SYNTAX HimYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "This field tells if the 'LEGK' feature is activated on the system. LEGK is a process within the call processing of HiPath 4000 with the following functions: - Gate keeper function: IP address resolution mechanism for IP trunking requiring the HG3550 board as hardware. - Resource Management: This function monitors network component usage for controlling IP trunking, IPDA scenarios, HFA and direct media connections. The LEGK can be activated at every HiPath 4000 in the network. Alternatively, it can be configured on a specific HiPath 4000 system only." ::= { himSysBasicEntry 4 } himSysLANCardsTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSysLANCardsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himSystem 2 } himSysLANCardsEntry OBJECT-TYPE SYNTAX HimSysLANCardsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSysLANCardsPabxId, himSysLANCardsIPAddr } ::= { himSysLANCardsTable 1 } HimSysLANCardsEntry ::= SEQUENCE { himSysLANCardsPabxId HimPabxId, himSysLANCardsIPAddr IpAddress, himSysLANCardsNetMask IpAddress, himSysLANCardsBroadCast IpAddress, himSysLANCardsType INTEGER, himSysLANCardsStatus INTEGER } himSysLANCardsPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSysLANCardsEntry 1 } himSysLANCardsIPAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Unique IP address within the Customer LAN." ::= { himSysLANCardsEntry 2 } himSysLANCardsNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The netmask of the LAN card. It depends on the class of the LAN Card address." ::= { himSysLANCardsEntry 3 } himSysLANCardsBroadCast OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The broadcast address is used to send a datagram packet to all hosts of a network or subnetwork, e.g. for address propagation from a router. The broadcast address also depends on the LAN Card address." ::= { himSysLANCardsEntry 4 } himSysLANCardsType OBJECT-TYPE SYNTAX INTEGER { ethernet(1), tokenring(2), other(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the LAN card. Possible values are Ethernet and Token Ring." ::= { himSysLANCardsEntry 5 } himSysLANCardsStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), stale(3), configured(4), unconfigured(5), other(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the configured LAN card. Can be one of the following: - Unknown (no traffic light lit): The LAN Card is configured, but no reboot has been performed. - Enabled (green traffic light lit): The LAN Card is active. - Disabled (red traffic light lit): The LAN Card is not active." ::= { himSysLANCardsEntry 6 } himSysHostsTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSysHostsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himSystem 3 } himSysHostsEntry OBJECT-TYPE SYNTAX HimSysHostsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSysHostsPabxId, himSysHostsNo } ::= { himSysHostsTable 1 } HimSysHostsEntry ::= SEQUENCE { himSysHostsPabxId HimPabxId, himSysHostsNo Integer32, himSysHostsIPAddr IpAddress, himSysHostsName OCTET STRING } himSysHostsPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSysHostsEntry 1 } himSysHostsNo OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the host entry." ::= { himSysHostsEntry 2 } himSysHostsIPAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the host." ::= { himSysHostsEntry 3 } himSysHostsName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..50)) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique name of the host." ::= { himSysHostsEntry 4 } himSysWAMLConn OBJECT IDENTIFIER ::= { himSystem 4 } himSysWAMLConnTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSysWAMLConnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himSysWAMLConn 1 } himSysWAMLConnEntry OBJECT-TYPE SYNTAX HimSysWAMLConnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSysWAMLConnPabxId, himSysWAMLConnLTG, himSysWAMLConnLTU, himSysWAMLConnSlot } ::= { himSysWAMLConnTable 1 } HimSysWAMLConnEntry ::= SEQUENCE { himSysWAMLConnPabxId HimPabxId, himSysWAMLConnLTG Integer32, himSysWAMLConnLTU Integer32, himSysWAMLConnSlot Integer32, himSysWAMLConnRufNr HimPhoneNumber, himSysWAMLConnBChl Unsigned32, himSysWAMLConnStatus OCTET STRING } himSysWAMLConnPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSysWAMLConnEntry 1 } himSysWAMLConnLTG OBJECT-TYPE SYNTAX Integer32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "Line/trunk group number. Valid values: 1-1" ::= { himSysWAMLConnEntry 2 } himSysWAMLConnLTU OBJECT-TYPE SYNTAX Integer32 (1..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Line/trunk unit. Valid values: 1-15, for IP Gateway DSP HW of NCUI STMI STMA WAML 1-99, for RG/ACGEN PER DIU SIUP TMD 17-99, for NCUI STMA WAML" ::= { himSysWAMLConnEntry 3 } himSysWAMLConnSlot OBJECT-TYPE SYNTAX Integer32 (1..145) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number of LTU (Line/Trunk Unit). Valid values: 1-121, for STMI, IP gateway, PER, RG, ACGEN, DIU, SIUP, TMD 1-145, for STMA, WAML" ::= { himSysWAMLConnEntry 4 } himSysWAMLConnRufNr OBJECT-TYPE SYNTAX HimPhoneNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Phone number of the WAML board." ::= { himSysWAMLConnEntry 5 } himSysWAMLConnBChl OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of b-channels on the WAML board." ::= { himSysWAMLConnEntry 6 } himSysWAMLConnStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the WAML board." ::= { himSysWAMLConnEntry 7 } himSysWAMLConnIPTable OBJECT-TYPE SYNTAX SEQUENCE OF HimSysWAMLConnIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { himSysWAMLConn 2 } himSysWAMLConnIPEntry OBJECT-TYPE SYNTAX HimSysWAMLConnIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himSysWAMLConnIPPabxId, himSysWAMLConnIPLTG, himSysWAMLConnIPLTU, himSysWAMLConnIPSlot, himSysWAMLConnIPIfName } ::= { himSysWAMLConnIPTable 1 } HimSysWAMLConnIPEntry ::= SEQUENCE { himSysWAMLConnIPPabxId HimPabxId, himSysWAMLConnIPLTG Integer32, himSysWAMLConnIPLTU Integer32, himSysWAMLConnIPSlot Integer32, himSysWAMLConnIPIfName OCTET STRING, himSysWAMLConnIPAddr IpAddress, himSysWAMLConnIPNetMask IpAddress } himSysWAMLConnIPPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himSysWAMLConnIPEntry 1 } himSysWAMLConnIPLTG OBJECT-TYPE SYNTAX Integer32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "Line/trunk group number. Valid values: 1-1" ::= { himSysWAMLConnIPEntry 2 } himSysWAMLConnIPLTU OBJECT-TYPE SYNTAX Integer32 (1..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Line/trunk unit. Valid values: 1-15, for IP Gateway DSP HW of NCUI STMI STMA WAML 1-99, for RG/ACGEN PER DIU SIUP TMD 17-99, for NCUI STMA WAML" ::= { himSysWAMLConnIPEntry 3 } himSysWAMLConnIPSlot OBJECT-TYPE SYNTAX Integer32 (1..145) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number of LTU (Line/Trunk Unit). Valid values: 1-121, for STMI, IP gateway, PER, RG, ACGEN, DIU, SIUP, TMD 1-145, for STMA, WAML" ::= { himSysWAMLConnIPEntry 4 } himSysWAMLConnIPIfName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the interface." ::= { himSysWAMLConnIPEntry 5 } himSysWAMLConnIPAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the WAML connection." ::= { himSysWAMLConnIPEntry 6 } himSysWAMLConnIPNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Net mask of the WAML connection." ::= { himSysWAMLConnIPEntry 7 } himBoards OBJECT IDENTIFIER ::= { hp4khim 12 } himBoardBasicTable OBJECT-TYPE SYNTAX SEQUENCE OF HimBoardBasicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the boards that are managed by CM. It can be viewed as an extension of hicomBCSUTable. Please note that the PEN (LTG, LTU, Slot) of LTU boards is different from what is contained in CM, and uses the same format as in the hicom MIB." ::= { himBoards 1 } himBoardBasicEntry OBJECT-TYPE SYNTAX HimBoardBasicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himBoardBasicPabxId, himBoardBasicLTG, himBoardBasicLTU, himBoardBasicSlot } ::= { himBoardBasicTable 1 } HimBoardBasicEntry ::= SEQUENCE { himBoardBasicPabxId HimPabxId, himBoardBasicLTG Integer32, himBoardBasicLTU Integer32, himBoardBasicSlot Integer32, himBoardBasicFuncId Integer32, himBoardBasicCat INTEGER, himBoardBasicName OCTET STRING, himBoardBasicVOIPSec HimYesNo, himBoardBasicLWVar OCTET STRING, himBoardBasicNoCirc Integer32 } himBoardBasicPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himBoardBasicEntry 1 } himBoardBasicLTG OBJECT-TYPE SYNTAX Integer32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "Line/trunk group number. Valid values: 1-1" ::= { himBoardBasicEntry 2 } himBoardBasicLTU OBJECT-TYPE SYNTAX Integer32 (1..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Line/trunk unit. Valid values: 1-15, for IP Gateway DSP HW of NCUI STMI STMA WAML 1-99, for RG/ACGEN PER DIU SIUP TMD 17-99, for NCUI STMA WAML" ::= { himBoardBasicEntry 3 } himBoardBasicSlot OBJECT-TYPE SYNTAX Integer32 (1..145) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number of LTU (Line/Trunk Unit). Valid values: 1-121, for STMI, IP gateway, PER, RG, ACGEN, DIU, SIUP, TMD 1-145, for STMA, WAML" ::= { himBoardBasicEntry 4 } himBoardBasicFuncId OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Function ID Valid values: 0-255 2 for SIU type 2 (MFV) 3 for SIU type 3 (MFC) 4 for SIU - RDS functionality 5 for SIU - ANI signaling 6 for SIU - CIS multifrequency (MFS) 7 for SIU - line testing" ::= { himBoardBasicEntry 5 } himBoardBasicCat OBJECT-TYPE SYNTAX INTEGER { ltg(1), ltu(2), per(3), perhw(4), acgen(5), diu(6), ipgw(7), rg(8), siup(9), tmd(10), other(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Category The board type includes: LTG -- line/trunk group LTU -- line/trunk unit PER -- peripheral module PERHW -- load peripheral hardware ACGEN -- alternating current generator DIU -- digital interface unit IPGW -- IP gateway RG -- ring generator SIUP -- signalling unit periphery TMD -- T1 boards" ::= { himBoardBasicEntry 6 } himBoardBasicName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..10)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the setup the board is configured to." ::= { himBoardBasicEntry 7 } himBoardBasicVOIPSec OBJECT-TYPE SYNTAX HimYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himBoardBasicEntry 8 } himBoardBasicLWVar OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "The loadware variant. Default value: 0 Valid values: 0-9, A-D" ::= { himBoardBasicEntry 9 } himBoardBasicNoCirc OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of circuits to be configured. Valid values: 1-255" ::= { himBoardBasicEntry 10 } himBoardIPTable OBJECT-TYPE SYNTAX SEQUENCE OF HimBoardIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the IP address configuration of the boards. Please note that not all fields are used for all boards." ::= { himBoards 2 } himBoardIPEntry OBJECT-TYPE SYNTAX HimBoardIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" AUGMENTS { himBoardBasicEntry } ::= { himBoardIPTable 1 } HimBoardIPEntry ::= SEQUENCE { himBoardIPGwyIPAddr IpAddress, himBoardIPSrcIPAddr IpAddress, himBoardIPNetMask IpAddress, himBoardIPDefRouter IpAddress, himBoardIPCustLANIP IpAddress, himBoardIPSTMI2IGWSubMask IpAddress, himBoardIPDefGWIP IpAddress, himBoardIPManStatIP IpAddress, himBoardIPManStatPort Integer32, himBoardIPBckpServIP IpAddress, himBoardIPBckpServPort Integer32 } himBoardIPGwyIPAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the gateway. Valid for: STMI" ::= { himBoardIPEntry 1 } himBoardIPSrcIPAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Source IP address of STMI-HFA board. A valid Source IP address must always be specified in order to enable the IP phones to address the system (SWU) Default: 0.0.0.0 Valid for: HFA" ::= { himBoardIPEntry 2 } himBoardIPNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP network mask. Valid for: HFA" ::= { himBoardIPEntry 3 } himBoardIPDefRouter OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the default router within the LAN segment. The default router takes care of routing forward all packets with a destination address with a network part different from the own LAN segment. Default: 0.0.0.0 Valid for: HFA" ::= { himBoardIPEntry 4 } himBoardIPCustLANIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of customer LAN. Default: 0.0.0.0 Valid for: IGW, SIP" ::= { himBoardIPEntry 5 } himBoardIPSTMI2IGWSubMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP subnet mask of LAN segment. Default: 0.0.0.0 Valid for: IGW, SIP" ::= { himBoardIPEntry 6 } himBoardIPDefGWIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Default gateway IP address. Default: 0.0.0.0 Valid for: IGW, SIP" ::= { himBoardIPEntry 7 } himBoardIPManStatIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of management station. Default: 0.0.0.0 Valid for: IGW, SIP" ::= { himBoardIPEntry 8 } himBoardIPManStatPort OBJECT-TYPE SYNTAX Integer32 (1024..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Port number of management station. Valid values: 1024 - 65535 Default: 0 Valid for: IGW, SIP" ::= { himBoardIPEntry 9 } himBoardIPBckpServIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of backup server. Default: 0.0.0.0 Valid for: IGW, SIP" ::= { himBoardIPEntry 10 } himBoardIPBckpServPort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Port number of backup server. Default: 0 (0 means 'undefined port number') Valid for: IGW, SIP" ::= { himBoardIPEntry 11 } himBoardLocTable OBJECT-TYPE SYNTAX SEQUENCE OF HimBoardLocEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the location data of the boards. It is only available for boards of type DSX, LTUCA, LTUCE and LTUCX." ::= { himBoards 3 } himBoardLocEntry OBJECT-TYPE SYNTAX HimBoardLocEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himBoardBasicPabxId, himBoardBasicLTG, himBoardBasicLTU, himBoardBasicSlot } ::= { himBoardLocTable 1 } HimBoardLocEntry ::= SEQUENCE { himBoardLocId Integer32, himBoardLocLoc OCTET STRING, himBoardLocPhoneNo HimPhoneNumber, himBoardLocFaxNo HimPhoneNumber } himBoardLocId OBJECT-TYPE SYNTAX Integer32 (0..999) MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the location of the switch for the system configurator. Valid values: 0-999" ::= { himBoardLocEntry 1 } himBoardLocLoc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..45)) MAX-ACCESS read-only STATUS current DESCRIPTION "Postal address of the LTU (Line/Trunk Unit) shelf. Applies to the Local Connection Type. Valid values: text, up to 45 characters" ::= { himBoardLocEntry 2 } himBoardLocPhoneNo OBJECT-TYPE SYNTAX HimPhoneNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Phone number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 characters" ::= { himBoardLocEntry 3 } himBoardLocFaxNo OBJECT-TYPE SYNTAX HimPhoneNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Fax number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 characters" ::= { himBoardLocEntry 4 } himIPDA OBJECT IDENTIFIER ::= { hp4khim 13 } himIPDAGenData OBJECT IDENTIFIER ::= { himIPDA 1 } himIPDAGenTable OBJECT-TYPE SYNTAX SEQUENCE OF HimIPDAGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "General settings that are true for all IPDAs." ::= { himIPDAGenData 1 } himIPDAGenEntry OBJECT-TYPE SYNTAX HimIPDAGenEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himIPDAGenPabxId } ::= { himIPDAGenTable 1 } HimIPDAGenEntry ::= SEQUENCE { himIPDAGenPabxId HimPabxId, himIPDAGenSpeed Integer32, himIPDAGenMode INTEGER, himIPDAGenPayConn Integer32, himIPDAGenSigConn Integer32 } himIPDAGenPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himIPDAGenEntry 1 } himIPDAGenSpeed OBJECT-TYPE SYNTAX Integer32 (10 | 100) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the bit-rate speed. Valid values: 10 Mbits/s; 100 Mbits/s" ::= { himIPDAGenEntry 2 } himIPDAGenMode OBJECT-TYPE SYNTAX INTEGER { fullduplex(1), halfduplex(2), other(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the bit-rate mode. Valid values: Full Duplex, Half Duplex" ::= { himIPDAGenEntry 3 } himIPDAGenPayConn OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "TOS for VoIP payload connections to APs (CP). Valid values: 0-255" ::= { himIPDAGenEntry 4 } himIPDAGenSigConn OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "TOS for signalling connections to APs (FA). Valid values: 0-255" ::= { himIPDAGenEntry 5 } himIPDAGenIPTable OBJECT-TYPE SYNTAX SEQUENCE OF HimIPDAGenIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "General IP settings that are true for all IPDAs." ::= { himIPDAGenData 2 } himIPDAGenIPEntry OBJECT-TYPE SYNTAX HimIPDAGenIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" AUGMENTS { himIPDAGenEntry } ::= { himIPDAGenIPTable 1 } HimIPDAGenIPEntry ::= SEQUENCE { himIPDAGenIPNetAddr IpAddress, himIPDAGenIPNetMask IpAddress, himIPDAGenIPCCAAddr IpAddress, himIPDAGenIPCCBAddr IpAddress, himIPDAGenIPDefRoutAddr IpAddress, himIPDAGenIPSurvNetAddr IpAddress } himIPDAGenIPNetAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP net address of HiPath LAN segment." ::= { himIPDAGenIPEntry 1 } himIPDAGenIPNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP net mask of HiPath LAN segment." ::= { himIPDAGenIPEntry 2 } himIPDAGenIPCCAAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Address of the CC-A processor within the HiPath LAN segment." ::= { himIPDAGenIPEntry 3 } himIPDAGenIPCCBAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Address of the CC-B processor within the HiPath LAN segment. Default value: 0.0.0.0" ::= { himIPDAGenIPEntry 4 } himIPDAGenIPDefRoutAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the default router within the HiPath LAN segment." ::= { himIPDAGenIPEntry 5 } himIPDAGenIPSurvNetAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the survivability net. Default value: 0.0.0.0" ::= { himIPDAGenIPEntry 6 } himIPDAAPData OBJECT IDENTIFIER ::= { himIPDA 2 } himIPDABasicTable OBJECT-TYPE SYNTAX SEQUENCE OF HimIPDABasicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table stores IPDA information from CM." ::= { himIPDAAPData 1 } himIPDABasicEntry OBJECT-TYPE SYNTAX HimIPDABasicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { himIPDABasicPabxId, himIPDABasicLTU } ::= { himIPDABasicTable 1 } HimIPDABasicEntry ::= SEQUENCE { himIPDABasicPabxId HimPabxId, himIPDABasicLTU Integer32, himIPDABasicConnType HimShelfNWType, himIPDABasicBChanNo Integer32, himIPDABasicConvAMLaw HimYesNo } himIPDABasicPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himIPDABasicEntry 1 } himIPDABasicLTU OBJECT-TYPE SYNTAX Integer32 (17..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Line/trunk unit. Valid values: 17-99" ::= { himIPDABasicEntry 2 } himIPDABasicConnType OBJECT-TYPE SYNTAX HimShelfNWType (0 | 3..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Connection type of the shelf. Valid values: APDL -- AP shelf via IP - direct linked APNW -- AP shelf via IP - network" ::= { himIPDABasicEntry 3 } himIPDABasicBChanNo OBJECT-TYPE SYNTAX Integer32 (1..120) MAX-ACCESS read-only STATUS current DESCRIPTION "Amount of B-Channels. Valid values: 1- 120" ::= { himIPDABasicEntry 4 } himIPDABasicConvAMLaw OBJECT-TYPE SYNTAX HimYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { himIPDABasicEntry 5 } himIPDAIPTable OBJECT-TYPE SYNTAX SEQUENCE OF HimIPDAIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the IP address configuration of the IPDAs." ::= { himIPDAAPData 2 } himIPDAIPEntry OBJECT-TYPE SYNTAX HimIPDAIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" AUGMENTS { himIPDABasicEntry } ::= { himIPDAIPTable 1 } HimIPDAIPEntry ::= SEQUENCE { himIPDAIPAccPtAddr IpAddress, himIPDAIPTAccPtAddr IpAddress, himIPDAIPAccPtRoutAddr IpAddress, himIPDAIPNetMaskNW IpAddress, himIPDAIPAccPtPriRoutAddr IpAddress, himIPDAIPNetMaskDL IpAddress } himIPDAIPAccPtAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the access point in the AP network." ::= { himIPDAIPEntry 1 } himIPDAIPTAccPtAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address for the TAP/Service PC link at the access point. This IP address must be in the same network as the access point in the AP network." ::= { himIPDAIPEntry 2 } himIPDAIPAccPtRoutAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the gateway (IP address of the router in the AP network)." ::= { himIPDAIPEntry 3 } himIPDAIPNetMaskNW OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Netmask of the network to which the respective Access Point in AP network belongs." ::= { himIPDAIPEntry 4 } himIPDAIPAccPtPriRoutAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the primary signalling router for NCUI board (IP address of the router in the HiPath 4000 LAN segment). Required if the connection type is APDL." ::= { himIPDAIPEntry 5 } himIPDAIPNetMaskDL OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Netmask of the network to which the Access Point in AP internal network belongs." ::= { himIPDAIPEntry 6 } himIPDALocTable OBJECT-TYPE SYNTAX SEQUENCE OF HimIPDALocEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the location data of the boards. It is only available for boards of type DSX, LTUCA, LTUCE and LTUCX." ::= { himIPDAAPData 3 } himIPDALocEntry OBJECT-TYPE SYNTAX HimIPDALocEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" AUGMENTS { himIPDABasicEntry } ::= { himIPDALocTable 1 } HimIPDALocEntry ::= SEQUENCE { himIPDALocId Integer32, himIPDALocLoc OCTET STRING, himIPDALocPhoneNo HimPhoneNumber, himIPDALocFaxNo HimPhoneNumber } himIPDALocId OBJECT-TYPE SYNTAX Integer32 (0..999) MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the location of the switch for the system configurator. Valid values: 0-999" ::= { himIPDALocEntry 1 } himIPDALocLoc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..45)) MAX-ACCESS read-only STATUS current DESCRIPTION "Postal address of the LTU (Line/Trunk Unit) shelf. Applies to the Local Connection Type. Valid values: text, up to 45 characters" ::= { himIPDALocEntry 2 } himIPDALocPhoneNo OBJECT-TYPE SYNTAX HimPhoneNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Phone number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 characters" ::= { himIPDALocEntry 3 } himIPDALocFaxNo OBJECT-TYPE SYNTAX HimPhoneNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Fax number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 characters" ::= { himIPDALocEntry 4 } himInfo OBJECT IDENTIFIER ::= { hp4khim 14 } -- The himInfo group himSubagentLastMsgNo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The last message, warning or error number issued by the Him subagent." ::= { himInfo 1 } himSubagentLastMsgText OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The last message, warning or error text issued by the Him subagent." ::= { himInfo 2 } himResultData OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Is used for agent internal communication. Contains the PabxId of a Hicom for which the last discovery process was conveyed. Is SET by the discovery agent and indicates the availability of new discovered data. The new data is to be incorporated by the subagent into the subagent's data base." ::= { himInfo 3 } -- BEGIN BLOCK discov himDiscovery OBJECT IDENTIFIER ::= { hp4khim 15 } himChanges OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of finished HIM discoveries - corresponds to the number of hicomHWDiscovXXX traps sent out." ::= { himDiscovery 1 } -- The himDiscovTable table himDiscovTable OBJECT-TYPE SYNTAX SEQUENCE OF HimDiscovEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table describing the status concerning discovery of HIM information." ::= { himDiscovery 2 } himDiscovEntry OBJECT-TYPE SYNTAX HimDiscovEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry describes the status of the discovery process. It is designed to comply with the structure of discovery entries in the hicom MIB, even though data is only provided for one switch." INDEX { himDiscovPabxId } ::= { himDiscovTable 1 } HimDiscovEntry ::= SEQUENCE { himDiscovPabxId HimPabxId, himDiscovPabxMnemonic DisplayString, himDiscovStatus DiscoveryStates, himDiscovMode DiscoveryModes, himDiscovTimDat DisplayString, himDiscovErrTimDat DisplayString } himDiscovPabxId OBJECT-TYPE SYNTAX HimPabxId MAX-ACCESS read-only STATUS current DESCRIPTION "Unique identifier of the Hicom being discovered." ::= { himDiscovEntry 1 } himDiscovPabxMnemonic OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the Hicom system." ::= { himDiscovEntry 2 } himDiscovStatus OBJECT-TYPE SYNTAX DiscoveryStates MAX-ACCESS read-write STATUS current DESCRIPTION "Status of discovery process. A managment station may initiate a discovery by setting this variable to value busy. The other values are set by the agent." ::= { himDiscovEntry 3 } himDiscovMode OBJECT-TYPE SYNTAX DiscoveryModes MAX-ACCESS read-write STATUS current DESCRIPTION "Mode of discovery process." ::= { himDiscovEntry 4 } himDiscovTimDat OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Date and time (year, month, day, hour, minute, second) the last successful discovery action was performed for the Hicom." ::= { himDiscovEntry 5 } himDiscovErrTimDat OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Date and time (year, month, day, hour, minute, second) the last failed discovery action was performed for the Hicom." ::= { himDiscovEntry 6 } himMibConformance OBJECT IDENTIFIER ::= { hp4khim 20 } himMibGroups OBJECT IDENTIFIER ::= { himMibConformance 1 } himWelcomePageGroup OBJECT-GROUP OBJECTS { himWelPgPabxId, himWelPgSysNo, himHP4KVersion, himSystemRelease, himRevisionLevel, himHWArchitecture, himHWArchitectureType, himOperationMode, himSWUProc1, himSWUMemory1, himSWUProc2, himSWUMemory2 } STATUS current DESCRIPTION "" ::= { himMibGroups 1 } himSwitchDataGroup OBJECT-GROUP OBJECTS { himTechInfoPabxId, himTechInfoInfoNo, himTechInfoDate, himTechInfoTechnicalData, himTechInfoNumber, himTechInfoExtraText, himNotepadDataPabxId, himNotepadDataInfoNo, himNotepadDataDate, himNotepadDataText, himProjPlanPabxId, himProjPlanInfoFile, himProjPlanInfoCreationDate, himProjPlanInfoCreationTime } STATUS current DESCRIPTION "" ::= { himMibGroups 2 } himSpecGroup OBJECT-GROUP OBJECTS { himSpecShelfDataPabxId, himSpecShelfDataAddress, himSpecShelfDataFrameType, himSpecShelfDataLTU, himSpecShelfDataNetworkType, himSpecShelfDataNetworkAddress, himSpecShelfDataRemote, himSpecShelfDataLocation, himSpecShelfDataLTUC, himSWUBoardPabxId, himSWUBoardPEN, himSWUBoardOverlayLTU, himSWUBoardType, himSWUBoardNominal, himSWUBoardActual, hhimSWUBoardFirmware, himSWUBoardRev, himSWUBoardFunctId, himSWUBoardMode, himSWUBoardLWNo, himSWUBoardLWInterVer, himSWUBoardLWName, himSWUBoardLWDate } STATUS current DESCRIPTION "" ::= { himMibGroups 3 } himSWUPeripheryGroup OBJECT-GROUP OBJECTS { himPSIOAssPabxId, himPSIOAssAssembly, himPSIOAssPEN, himPSIOAssActual, himPSIOAssFirmware, himSerialLinePabxId, himSerialLineBoardType, himSerialLineNumber, himSerialLineSpeed, himSerialLineLogDevName, himSerialLineDevType, himSerialLineType, himSCSIDevPabxId, himSCSIDevId, himSCSIDevType, himSCSIDevName, himSCSIDevFirmware, himSCSIDevLoadDrive } STATUS current DESCRIPTION "" ::= { himMibGroups 4 } himCentralSwitchGroup OBJECT-GROUP OBJECTS { himCabPabxId, himCabAddr, himCabPhysAddr, himCabCabinet, himCabPartNo, himCabShelfNo, himCabFrame, himCabPid1, himCabPid2, himCabPid3, himCabLTUNo, himMemScalingPabxId, himMemScalingUnit, himMemScalingUsed, himMemScalingMaxUsed, himMemScalingAllocated, himMemScalingStandard, himMemScalingSysMax } STATUS current DESCRIPTION "" ::= { himMibGroups 5 } himGeneralSwitchGroup OBJECT-GROUP OBJECTS { himDBConfSysPabxId, himDBConfSysClass1, himDBConfSysClass2, himDBConfSysHWAss1, himDBConfSysHWAss2, himDBConfSysDevLine1, himDBConfSysDevLine2, himDBConfSysOpMode, himDBConfSysResType, himDBConfSysHWArch, himDBConfSysHWArchType, himDBConfSysNo, himDBConfSysLoc, himDBConfSysBaseApp, himDBConfSysDBApp, himDBConfSysID, himDBConfHWPabxId, himDBConfHWLTG, himDBConfHWLTU, himDBConfHWLines, himDBConfHWPorts, himDBConfHWPBC, himDBConfHWMTSBdPerGSN, himDBConfHWSIUPPerLTU, himDBConfHWDIUCPerLTU, himDBConfHWHwyPerMTSBd, himDBConfHWHDLCPerDCL, himDBConfHWPBCPerDCL, himDBConfHWStdSIULine, himDBConfHWConfLine, himDBConfHWDBDim, himDBConfHWTableVer, himHWDataPabxId, himHWArch, himHWArchType, himHWOpMode, himHWSWUProc1, himHWSWUMem1, himHWSWUProc2, himHWSWUMem2, himHWADPProc, himHWADPMem, himLWDataOnCBPabxId, himLWOnCBAss, himLWOnCBPBCAddr, himLWOnCBFileName, himLWOnCBProdTime, himLWOnProcPabxId, himLWOnProcAss, himLWOnProcInfoType, himLWOnProcLWId, himLWOnProcLWIdCMP, himLWOnProcLWIdLP, himLWOnCSIUPabxId, himLWOnCSIUProc, himLWOnCSIUSlot, himLWOnCSIUNominal, himLWOnCSIUActual, himLWOnCSIULWNo, himLWOnCSIUFileName, himLWOnCSIUFileProd, himMacAddrPabxId, himMacAddrProc, himMacAddrInfoType, himMacAddrCLan, himMacAddrIPDA } STATUS current DESCRIPTION "" ::= { himMibGroups 6 } himFeaturesGroup OBJECT-GROUP OBJECTS { himMacAddrPabxId, himMacAddrProc, himMacAddrCLan, himMacAddrIPDA, himMarkFeatPabxId, himMarkFeatVer, himMarkFeatSerNo, himMarkFeatHWId, himMarkFeatInstallDate, himMarkFeatExpiryDate, himMarkFeatConfCode, himMarkFeatTrialModeAct, himMarkFeatTrialRemDays, himSalesFeatPabxId, himSalesFeatMarketPackId, himSalesFeatMarketPack, himSalesFeatContract, himSalesFeatUsed, himSalesFeatFree, himSalesFeatMarkForTrial, himTechFeatPabxId, himTechFeatId, himTechFeatName, himTechFeatState } STATUS current DESCRIPTION "" ::= { himMibGroups 7 } himAPSPatchesGroup OBJECT-GROUP OBJECTS { himSwitchAPSPabxId, himSwitchAPSName, himSwitchAPSCorrVer, himSwitchAPSPartNo, himReplAMOPabxId, himReplAMOAPS, himReplAMOName, himReplAMOInAPSDir, himReplAMOSubsystem, himPatchInfoPabxId, himPatchInfoPatchNo, himPatchInfoPatchGroup, himPatchInfoOpt, himPatchInfoActHD, himPatchInfoActADP, himPatchInfoActBP } STATUS current DESCRIPTION "" ::= { himMibGroups 8 } himSWVersionGroup OBJECT-GROUP OBJECTS { himSWVerOnProcPabxId, himSWVerOnProcSrc, himSWVerOnProcSWVer, himSWVerOnProcItemCodeNoPrefix, himSWVerOnProcHP4KVer, himSWVerOnProcSysRel, himSWVerOnProcCountry, himSWVerOnProcCountryCode, himSWVerOnProcRevNo } STATUS current DESCRIPTION "" ::= { himMibGroups 9 } himSWPkgVersionGroup OBJECT-GROUP OBJECTS { himSWPkgVerPabxId, himSWPkgVerPkgAbbr, himSWPkgVerPkgName, himSWPkgVerVersion, himSWPkgVerInstAt, himSWPkgVerStatus } STATUS current DESCRIPTION "" ::= { himMibGroups 10 } himSystemGroup OBJECT-GROUP OBJECTS { himSysBasicPabxId, himSysBasicDomain, himSysBasicNodeNo, himSysBasicLEGK, himSysLANCardsPabxId, himSysLANCardsIPAddr, himSysLANCardsNetMask, himSysLANCardsBroadCast, himSysLANCardsType, himSysLANCardsStatus, himSysHostsPabxId, himSysHostsNo, himSysHostsIPAddr, himSysHostsName, himSysWAMLConnPabxId, himSysWAMLConnLTG, himSysWAMLConnLTU, himSysWAMLConnSlot, himSysWAMLConnRufNr, himSysWAMLConnBChl, himSysWAMLConnStatus, himSysWAMLConnIPPabxId, himSysWAMLConnIPLTG, himSysWAMLConnIPLTU, himSysWAMLConnIPSlot, himSysWAMLConnIPIfName, himSysWAMLConnIPAddr, himSysWAMLConnIPNetMask } STATUS current DESCRIPTION "" ::= { himMibGroups 11 } himBoardsGroup OBJECT-GROUP OBJECTS { himBoardBasicPabxId, himBoardBasicLTG, himBoardBasicLTU, himBoardBasicSlot, himBoardBasicFuncId, himBoardBasicCat, himBoardBasicName, himBoardBasicVOIPSec, himBoardBasicLWVar, himBoardBasicNoCirc, himBoardIPGwyIPAddr, himBoardIPSrcIPAddr, himBoardIPNetMask, himBoardIPDefRouter, himBoardIPCustLANIP, himBoardIPSTMI2IGWSubMask, himBoardIPDefGWIP, himBoardIPManStatIP, himBoardIPManStatPort, himBoardIPBckpServIP, himBoardIPBckpServPort, himBoardLocId, himBoardLocLoc, himBoardLocPhoneNo, himBoardLocFaxNo } STATUS current DESCRIPTION "" ::= { himMibGroups 12 } himIPDAGroup OBJECT-GROUP OBJECTS { himIPDABasicPabxId, himIPDABasicLTU, himIPDABasicConnType, himIPDABasicBChanNo, himIPDABasicConvAMLaw, himIPDAGenPabxId, himIPDAGenSpeed, himIPDAGenMode, himIPDAGenPayConn, himIPDAGenSigConn, himIPDAGenIPNetAddr, himIPDAGenIPNetMask, himIPDAGenIPCCAAddr, himIPDAGenIPCCBAddr, himIPDAGenIPDefRoutAddr, himIPDAGenIPSurvNetAddr, himIPDAIPAccPtAddr, himIPDAIPTAccPtAddr, himIPDAIPAccPtRoutAddr, himIPDAIPNetMaskNW, himIPDAIPAccPtPriRoutAddr, himIPDAIPNetMaskDL, himIPDALocId, himIPDALocLoc, himIPDALocPhoneNo, himIPDALocFaxNo } STATUS current DESCRIPTION "" ::= { himMibGroups 13 } himInfoGroup OBJECT-GROUP OBJECTS { himSubagentLastMsgNo, himSubagentLastMsgText, himResultData } STATUS current DESCRIPTION "" ::= { himMibGroups 14 } himDiscoveryGroup OBJECT-GROUP OBJECTS { himChanges, himDiscovPabxId, himDiscovPabxMnemonic, himDiscovStatus, himDiscovMode, himDiscovTimDat, himDiscovErrTimDat } STATUS current DESCRIPTION "" ::= { himMibGroups 15 } himTrapsGroup NOTIFICATION-GROUP NOTIFICATIONS { internalMessageHimSubagent, internalWarningHimSubagent, internalErrorHimSubagent, himDiscovSucc, himDiscovErr, himDiscovBusy } STATUS current DESCRIPTION "" ::= { himMibGroups 16 } -- Traps / Notifications himTrapGroup OBJECT IDENTIFIER ::= { hp4khim 21 } himTrapVariables OBJECT IDENTIFIER ::= { himTrapGroup 1 } -- Trap Variables himTrapPabxId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique identifier of a Hicom system." ::= { himTrapVariables 1 } himTrapPabxMnemonic OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS not-accessible STATUS current DESCRIPTION "Mnemonic name of the Hicom system." ::= { himTrapVariables 2 } -- Message Traps himTraps OBJECT IDENTIFIER ::= { himTrapGroup 2 } internalMessageHimSubagent NOTIFICATION-TYPE OBJECTS { himSubagentLastMsgNo, himSubagentLastMsgText} STATUS current DESCRIPTION "An internalMessage trap contains an informational message generated by the subagent." ::= { himTraps 0 } -- Warning Traps internalWarningHimSubagent NOTIFICATION-TYPE OBJECTS { himSubagentLastMsgNo, himSubagentLastMsgText} STATUS current DESCRIPTION "An internalWarning trap contains a warning message generated by a subagent." ::= { himTraps 1 } -- Error Traps internalErrorHimSubagent NOTIFICATION-TYPE OBJECTS { himSubagentLastMsgNo, himSubagentLastMsgText} STATUS current DESCRIPTION "An internalError trap contains an error message generated by a subagent. After issuing this trap, the agent terminates." ::= { himTraps 2 } -- him discovery successfully terminated himDiscovSucc NOTIFICATION-TYPE OBJECTS { himTrapPabxId, himTrapPabxMnemonic} STATUS current DESCRIPTION "A himDiscovSucc trap indicates the successful termination of a discovery process." ::= { himTraps 10 } -- him discovery unsuccessfully terminated himDiscovErr NOTIFICATION-TYPE OBJECTS { himTrapPabxId, himTrapPabxMnemonic} STATUS current DESCRIPTION "A himDiscovErr trap signifies the unsuccessful termination of a discovery process." ::= { himTraps 11 } -- him discovery is busy himDiscovBusy NOTIFICATION-TYPE OBJECTS { himTrapPabxId, himTrapPabxMnemonic} STATUS current DESCRIPTION "A himDiscovBusy trap signifies that a sw discovery process is running." ::= { himTraps 19 } END