-- $Revision: 1.8 $ SYNC-RESEARCH-MIB DEFINITIONS ::= BEGIN IMPORTS -- If any of the MIB compilers have problems with the -- internet, mgmt, NetworkAddress, IpAddess, Counter, Gauge, -- TimeTicks, enterprises, uncomment the next two lines and\ -- comment the next third and forth line. --internet, mgmt, NetworkAddress, IpAddress, Counter, Gauge, --TimeTicks, enterprises enterprises, IpAddress, Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 --syncResearch --FROM SYNC-RESEARCH-COMMUNITY-MIB TRAP-TYPE FROM RFC-1215; -- -- Sync Research interNode MIB Version 4.0 -- -- The MIB was developed by Sync Research. It is not compatible -- with versions prior to 3.1 of MIBs published by Sync Research. -- -- -- Last Modification: -- -- 08/21/95 Suketu Pandya version 4.0.3 -- Added cable type variable for lineStatusChanged trap. -- 08/14/95 Suketu Pandya version 4.0.2 -- Added new values for unitModel, -- brStatsGroup, and -- lineSwitchedConnection (VAR in linePhysicalGroup) -- frameRelayExcessBurst -- frameRelayCommittedBurst -- 07/18/95 Suketu Pandya version 4.0.1 -- Added sysobjectids for R4 (Sync, Cabletron and 3Com) -- 06/23/95 Suketu Pandya version 4.0.0 -- Added the following new MIB vriables: -- excessBurstGovernor [unitConfigGroup] -- measurementPeriod [unitConfigGroup] -- markDEBit [unitConfigGroup] -- frExtCircuitTxDe [frExtCircuitEntry] -- frExtCircuitRxDe [frExtCircuitEntry] -- frExtCircuitMinBits [frExtCircuitEntry] -- frExtCircuitMaxBits [frExtCircuitEntry] -- frExtCircuitQOctets [frExtCircuitEntry] -- frameRelaySessSwitchThreshold [frameRelayConfigEntry] -- frameRelaySwitchedBackup [frameRelayConfigEntry] -- frameRelaySwitchedLineWaitTimer[frameRelayConfigEntry] -- frameRelayDedLineWaitTimer [frameRelayConfigEntry] -- frameRelayTxDe [frameRelayStatsEntry] -- frameRelayRxDe [frameRelayStatsEntry] -- frameRelaySwitchedAttempts [frameRelayStatsEntry] -- frameRelaySwitchedAttemptsSuccessful -- [frameRelayStatsEntry] -- -- Also added the following TRAPs: -- lostUNI -- restoredUNI -- switchedToBackup -- switchedToDed -- -- -- -- 07/18/95 Suketu Pandya Version 3.2 -- Added QLLC CN sysobject id for Cabletron and added -- R3 Object IDs. -- 06/12/95 Kevin Wong -- Change frExtCircuitTable entries Ignored and Acknowledged to yes/no. -- Chnage values of consolidated status constants in the unitControlGroup. -- Change description for puCurrentMAC in the puControlGroup. -- Change description for puLastClearCode in the puControlGroup. -- 02/28/95 Kevin Wong and Suketu Pandya, -- Obsolete puMappingGroup with puRemoteGroup. -- Added t7ConfigGroup for T7 protocol support. -- Added lineAsyncGroup, and puAsyncGroup for Async support. -- Added variables to unitConfigGroup and for best WAN support. -- Added variable to the unitControlGroup, lineControlGroup, -- and puControlGroup consolidated status support. -- Added nodeFrCirGroup to support consolidated status for -- frame relay virtual circuits. -- Added sessSwitchedToPrimaryDLCI TRAP. -- Added sessSwitchedToParallelDLCI TRAP. -- Added sessUpOnPrimaryDLCI TRAP. -- Added sessUpOnParallelDLCI TRAP. -- Added sessUpOnAlternateDLCI TRAP. -- Added sessUpOnBroadCastDLCI TRAP. -- Added sessUpOnAlternateMAC TRAP. -- Obolete puConnectionStatusUp and puConnectionStatusDown Traps. -- -- 01/27/95 Pam Tossey, Added variables to puControlGroup, and -- netviewControlGroup to count connection attempts. -- Addeded two new traps, puConnectionStatusUp and -- puConnectionStatusDown if the connection state changes for PU, netview -- PUs, and alternate netview PUs. Trap number 808 is no longer generated. -- The varbind list for port and PU traps was changed to include port and -- PU ids. -- -- 12/27/94 Pam Tossey, Modified IMPORTS definitions of the MIB module -- (synccomb.mib) so that it is compiled using Sync's tools (amc). -- MIB module synccomb.mib contains all objects for Sync's MIB and -- Sync Community MIB and Traps. -- -- 12/21/94 Steve Christle, corrected bug in msExtBoardType definition. -- -- 11/17/94 Pam Tossey, Modified password and configpassword to have -- read-write access. -- -- 11/08/94 Pam Tossey, Modified Sync's MIBs to include our OEM partners -- new products. -- -- 08/31/94 Pam Tossey, changed variable access of dateTimeField to -- read-write. -- -- 06/13/94 Steve Christle, Pam Tossey, Sync Research, Version 2.0 -- initial definition supporting FN4R2, CN4 -- -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212. -- -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. -- DisplayString ::= OCTET STRING PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- directory OBJECT IDENTIFIER ::= { internet 1 } -- mgmt OBJECT IDENTIFIER ::= { internet 2 } -- experimental OBJECT IDENTIFIER ::= { internet 3 } -- private OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { private 1 } syncResearch OBJECT IDENTIFIER ::= { enterprises 485 } -- The next variable agent object ID. syncResearchAgent OBJECT IDENTIFIER ::= { syncResearch 1 } -- The syncProducts group contains both Sync Research's Frame Node and -- Conversion Node. syncProducts OBJECT IDENTIFIER ::= { syncResearchAgent 1 } -- The oemProducts group contains Sync Research's OEM products oemProducts OBJECT IDENTIFIER ::= { syncResearchAgent 2 } -- Subgroup of syncProducts boundary OBJECT IDENTIFIER ::= { syncProducts 1 } centralSite OBJECT IDENTIFIER ::= { syncProducts 2 } -- Subgroups of the Boundary Group syncCN2R2b OBJECT IDENTIFIER ::= { boundary 1 } syncFN2R2b OBJECT IDENTIFIER ::= { boundary 2 } syncCN4R2b OBJECT IDENTIFIER ::= { boundary 3 } syncFN4R2b OBJECT IDENTIFIER ::= { boundary 4 } syncQN4R2b OBJECT IDENTIFIER ::= { boundary 5 } syncCN4R3b OBJECT IDENTIFIER ::= { boundary 6 } syncFN4R3b OBJECT IDENTIFIER ::= { boundary 7 } syncQN4R3b OBJECT IDENTIFIER ::= { boundary 8 } syncCN4R4b OBJECT IDENTIFIER ::= { boundary 9 } syncFN4R4b OBJECT IDENTIFIER ::= { boundary 10 } syncQN4R4b OBJECT IDENTIFIER ::= { boundary 11 } syncCN4R4bu OBJECT IDENTIFIER ::= { boundary 12 } syncFN4R4bu OBJECT IDENTIFIER ::= { boundary 13 } syncQN4R4bu OBJECT IDENTIFIER ::= { boundary 14 } syncCN4R4du OBJECT IDENTIFIER ::= { boundary 15 } syncFN4R4du OBJECT IDENTIFIER ::= { boundary 16 } syncQN4R4du OBJECT IDENTIFIER ::= { boundary 17 } syncCN2R2du OBJECT IDENTIFIER ::= { boundary 18 } syncFN2R2du OBJECT IDENTIFIER ::= { boundary 19 } syncCN3R4bu OBJECT IDENTIFIER ::= { boundary 20 } syncFN3R4bu OBJECT IDENTIFIER ::= { boundary 21 } syncCN3R4du OBJECT IDENTIFIER ::= { boundary 22 } syncFN3R4du OBJECT IDENTIFIER ::= { boundary 23 } syncCN4R5b OBJECT IDENTIFIER ::= { boundary 24 } syncFN4R5b OBJECT IDENTIFIER ::= { boundary 25 } syncQN4R5b OBJECT IDENTIFIER ::= { boundary 26 } syncCN4R5bu OBJECT IDENTIFIER ::= { boundary 27 } syncFN4R5bu OBJECT IDENTIFIER ::= { boundary 28 } syncQN4R5bu OBJECT IDENTIFIER ::= { boundary 29 } syncCN4R5du OBJECT IDENTIFIER ::= { boundary 30 } syncFN4R5du OBJECT IDENTIFIER ::= { boundary 31 } syncQN4R5du OBJECT IDENTIFIER ::= { boundary 32 } syncFN5R5du OBJECT IDENTIFIER ::= { boundary 33 } syncBC4R5b OBJECT IDENTIFIER ::= { boundary 34 } syncBF4R5b OBJECT IDENTIFIER ::= { boundary 35 } syncBF3R5b OBJECT IDENTIFIER ::= { boundary 36 } syncBF5R5b OBJECT IDENTIFIER ::= { boundary 37 } -- Added Sync's 4200 products for release 5.600 syncFN3R5du OBJECT IDENTIFIER ::= { boundary 38 } syncCN3R5du OBJECT IDENTIFIER ::= { boundary 39 } syncCN5R5du OBJECT IDENTIFIER ::= { boundary 40 } -- Sync's 3600 products for release 5.600 syncBF3R5 OBJECT IDENTIFIER ::= { boundary 41 } syncBC3R5 OBJECT IDENTIFIER ::= { boundary 42 } syncBF4R5 OBJECT IDENTIFIER ::= { boundary 43 } syncBC4R5 OBJECT IDENTIFIER ::= { boundary 44 } syncBF5R5 OBJECT IDENTIFIER ::= { boundary 45 } syncBC5R5 OBJECT IDENTIFIER ::= { boundary 46 } -- Subgroups of the CentralSite Group syncCN4R2c OBJECT IDENTIFIER ::= { centralSite 1 } syncFN4R2c OBJECT IDENTIFIER ::= { centralSite 2 } syncQN4R2c OBJECT IDENTIFIER ::= { centralSite 3 } syncCN4R3c OBJECT IDENTIFIER ::= { centralSite 4 } syncFN4R3c OBJECT IDENTIFIER ::= { centralSite 5 } syncQN4R3c OBJECT IDENTIFIER ::= { centralSite 6 } syncCN4R4u OBJECT IDENTIFIER ::= { centralSite 7 } syncFN4R4u OBJECT IDENTIFIER ::= { centralSite 8 } syncQN4R4u OBJECT IDENTIFIER ::= { centralSite 9 } -- Subgroups of oemProducts threeCom OBJECT IDENTIFIER ::= { oemProducts 1 } cableTron OBJECT IDENTIFIER ::= { oemProducts 2 } chipcom OBJECT IDENTIFIER ::= { oemProducts 3 } ibm OBJECT IDENTIFIER ::= { oemProducts 4 } -- Subgroups of the threeCom EOM linkConverter OBJECT IDENTIFIER ::= { threeCom 1 } linkConverter2 OBJECT IDENTIFIER ::= { threeCom 2 } -- 486 based linconverters, Ethernet and Token Ring -- 4 port and 2port. lc2EN2port OBJECT IDENTIFIER ::= { threeCom 3 } lc2EN4port OBJECT IDENTIFIER ::= { threeCom 4 } lc2TR2port OBJECT IDENTIFIER ::= { threeCom 5 } lc2TR6port OBJECT IDENTIFIER ::= { threeCom 6 } -- Subgroups of the CableTron OEM oemSNACXR2C OBJECT IDENTIFIER ::= { cableTron 1 } oemSNACXR2W OBJECT IDENTIFIER ::= { cableTron 2 } oemSNACMR2C OBJECT IDENTIFIER ::= { cableTron 3 } oemSNACMR2W OBJECT IDENTIFIER ::= { cableTron 4 } oemSNACMIM2 OBJECT IDENTIFIER ::= { cableTron 5 } oemSNACXR2Q OBJECT IDENTIFIER ::= { cableTron 6 } oemSNACMR2Q OBJECT IDENTIFIER ::= { cableTron 7 } oemSNACXR3C OBJECT IDENTIFIER ::= { cableTron 8 } oemSNACXR3W OBJECT IDENTIFIER ::= { cableTron 9 } oemSNACMR3C OBJECT IDENTIFIER ::= { cableTron 10 } oemSNACMR3W OBJECT IDENTIFIER ::= { cableTron 11 } oemSNACXR3Q OBJECT IDENTIFIER ::= { cableTron 12 } oemSNACMR3Q OBJECT IDENTIFIER ::= { cableTron 13 } oemSNACXR4C OBJECT IDENTIFIER ::= { cableTron 14 } oemSNACXR4W OBJECT IDENTIFIER ::= { cableTron 15 } oemSNACMR4C OBJECT IDENTIFIER ::= { cableTron 16 } oemSNACMR4W OBJECT IDENTIFIER ::= { cableTron 17 } oemSNACXR4Q OBJECT IDENTIFIER ::= { cableTron 18 } oemSNACMR4Q OBJECT IDENTIFIER ::= { cableTron 19 } -- Subgroups of the IBM OEM oem2490R22F OBJECT IDENTIFIER ::= { ibm 1 } oem2490R22C OBJECT IDENTIFIER ::= { ibm 2 } -- 486 based 2mB DRAM/2mB FLASH oem22181FR4 OBJECT IDENTIFIER ::= { ibm 3 } oem22181CR4 OBJECT IDENTIFIER ::= { ibm 4 } -- 486 based 4mB DRAM/2mB FLASH oem22183FR4 OBJECT IDENTIFIER ::= { ibm 5 } oem22183CR4 OBJECT IDENTIFIER ::= { ibm 6 } -- 486 based 2mB DRAM/2mB FLASH oem22181FR5 OBJECT IDENTIFIER ::= { ibm 7 } oem22181CR5 OBJECT IDENTIFIER ::= { ibm 8 } -- 486 based 4mB DRAM/2mB FLASH oem22183FR5 OBJECT IDENTIFIER ::= { ibm 9 } oem22183CR5 OBJECT IDENTIFIER ::= { ibm 10 } -- 486 based 8mB DRAM/2mB FLASH oem22185FR5 OBJECT IDENTIFIER ::= { ibm 11 } -- Added IBM's 4200 product for release 5.600 oem22185CR5 OBJECT IDENTIFIER ::= { ibm 12 } -- IBM's 3600 products for release 5.600 oem22183BF5 OBJECT IDENTIFIER ::= { ibm 13 } oem22183BC5 OBJECT IDENTIFIER ::= { ibm 14 } oem22184BF5 OBJECT IDENTIFIER ::= { ibm 15 } oem22184BC5 OBJECT IDENTIFIER ::= { ibm 16 } oem22185BF5 OBJECT IDENTIFIER ::= { ibm 17 } oem22185BC5 OBJECT IDENTIFIER ::= { ibm 18 } -- The Node group contains both the Frame Node and Conversion Node. srNodeGroup OBJECT IDENTIFIER ::= { syncResearch 3 } -- Subgroups of the Node group. nodeUnitGroup OBJECT IDENTIFIER ::= { srNodeGroup 1 } nodeNetViewPUGroup OBJECT IDENTIFIER ::= { srNodeGroup 2 } nodeBridgeGroup OBJECT IDENTIFIER ::= { srNodeGroup 3 } nodeLANGroup OBJECT IDENTIFIER ::= { srNodeGroup 4 } nodeLineGroup OBJECT IDENTIFIER ::= { srNodeGroup 5 } nodePUGroup OBJECT IDENTIFIER ::= { srNodeGroup 6 } nodeDeviceGroup OBJECT IDENTIFIER ::= { srNodeGroup 7 } nodeT7Group OBJECT IDENTIFIER ::= { srNodeGroup 8 } nodeFrCirGroup OBJECT IDENTIFIER ::= { srNodeGroup 9 } nodeSlipGroup OBJECT IDENTIFIER ::= { srNodeGroup 10} nodeIpxGroup OBJECT IDENTIFIER ::= { srNodeGroup 11} nodeIpGroup OBJECT IDENTIFIER ::= { srNodeGroup 12} -- Subgroups of the Unit Group unitControlGroup OBJECT IDENTIFIER ::= { nodeUnitGroup 1 } unitStatusGroup OBJECT IDENTIFIER ::= { nodeUnitGroup 2 } unitConfigGroup OBJECT IDENTIFIER ::= { nodeUnitGroup 3 } unitStatisticsGroup OBJECT IDENTIFIER ::= { nodeUnitGroup 4 } -- Subgroups of the Netview Group netViewPUStatusGroup OBJECT IDENTIFIER ::= { nodeNetViewPUGroup 1 } netViewPUConfigGroup OBJECT IDENTIFIER ::= { nodeNetViewPUGroup 2 } -- Subgroups of the Bridge Group bridgeConfigGroup OBJECT IDENTIFIER ::= { nodeBridgeGroup 1 } bridgeStatsGroup OBJECT IDENTIFIER ::= { nodeBridgeGroup 2 } -- Subgroups of the IPX Group ipxConfigGroup OBJECT IDENTIFIER ::= { nodeIpxGroup 1 } -- Subgroups of the IP Group ipConfigGroup OBJECT IDENTIFIER ::= { nodeIpGroup 1 } -- Subgroups of the LAN Group lanControlGroup OBJECT IDENTIFIER ::= { nodeLANGroup 1 } lanTokenRingGroup OBJECT IDENTIFIER ::= { nodeLANGroup 2 } -- Subgroups of the Line Group lineControlGroup OBJECT IDENTIFIER ::= { nodeLineGroup 1 } linePhysicalGroup OBJECT IDENTIFIER ::= { nodeLineGroup 2 } lineSDLCGroup OBJECT IDENTIFIER ::= { nodeLineGroup 3 } lineBisyncGroup OBJECT IDENTIFIER ::= { nodeLineGroup 4 } lineFrameRelayGroup OBJECT IDENTIFIER ::= { nodeLineGroup 5 } lineAsyncGroup OBJECT IDENTIFIER ::= { nodeLineGroup 6 } lineBisyncRjeGroup OBJECT IDENTIFIER ::= { nodeLineGroup 7 } lineDialBackupGroup OBJECT IDENTIFIER ::= { nodeLineGroup 8 } lineX25Group OBJECT IDENTIFIER ::= { nodeLineGroup 9 } lineAlcGroup OBJECT IDENTIFIER ::= { nodeLineGroup 10} -- Subgroups of the LinePhysical Group isdnControlGroup OBJECT IDENTIFIER ::= { linePhysicalGroup 2 } dsucsuControlGroup OBJECT IDENTIFIER ::= { linePhysicalGroup 3 } -- Other future Line types (e.g. X.25) would be added here. -- Note Token Ring Statistics are obtained via the 802.5 standard -- MIB as defined in RFC 1231, and Ethernet via 802.3 standard MIB -- Subgroups of the PU Group puControlGroup OBJECT IDENTIFIER ::= { nodePUGroup 1 } puSDLCGroup OBJECT IDENTIFIER ::= { nodePUGroup 2 } puBisyncGroup OBJECT IDENTIFIER ::= { nodePUGroup 3 } puMappingGroup OBJECT IDENTIFIER ::= { nodePUGroup 4 } puAsyncGroup OBJECT IDENTIFIER ::= { nodePUGroup 5 } puLanGroup OBJECT IDENTIFIER ::= { nodePUGroup 6 } puRemoteGroup OBJECT IDENTIFIER ::= { nodePUGroup 7 } puX25Group OBJECT IDENTIFIER ::= { nodePUGroup 8 } puAlcGroup OBJECT IDENTIFIER ::= { nodePUGroup 9 } puBisyncRjeGroup OBJECT IDENTIFIER ::= { nodePUGroup 10} -- Subgroups of the Device Group deviceControlGroup OBJECT IDENTIFIER ::= { nodeDeviceGroup 1 } deviceBSCGroup OBJECT IDENTIFIER ::= { nodeDeviceGroup 2 } deviceALCGroup OBJECT IDENTIFIER ::= { nodeDeviceGroup 3 } -- Subgroups of the T7 Group t7ConfigGroup OBJECT IDENTIFIER ::= { nodeT7Group 1 } t7StatsGroup OBJECT IDENTIFIER ::= { nodeT7Group 2 } -- Subgroups of the Slip Group slipConfigGroup OBJECT IDENTIFIER ::= { nodeSlipGroup 1 } slipStatsGroup OBJECT IDENTIFIER ::= { nodeSlipGroup 2 } -- The Sync Research Community Name and Trap Group srCommTrapGroup OBJECT IDENTIFIER ::= { syncResearch 2 } commCount OBJECT-TYPE SYNTAX INTEGER (0..32) ACCESS read-only STATUS mandatory DESCRIPTION "The number of possible community name entries in the table." ::= { srCommTrapGroup 1 } commTable OBJECT-TYPE SYNTAX SEQUENCE OF CommEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table houses the information for trivial authentication and sending traps." ::= { srCommTrapGroup 2 } commEntry OBJECT-TYPE SYNTAX CommEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains a community name and access code for SNMP trivial authentication and enable/disable traps options, as well as network and physical addressing information for traps." INDEX { commIndex } ::= { commTable 1 } CommEntry ::= SEQUENCE { commIndex INTEGER, commName OCTET STRING, commTrap INTEGER, commIPAddr IpAddress, commMACAddr OCTET STRING, commAccess INTEGER } commIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each community entry. Its value ranges between 1 and commCount." ::= { commEntry 1 } commName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A community name that will be used to access MIB objects. Each community name is associated with an access code of either NO-ACCESS, RO, RW, or SU." ::= { commEntry 2 } commTrap OBJECT-TYPE SYNTAX INTEGER { trapoff(1), trapon(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is checked to determine if traps should be sent to the corresponding network address associated with it." ::= { commEntry 3 } commIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The network address of the device that will receive traps from the agent. This IP address also qualifies who may use this community name to access MIB objects. If this community name is use by some one with a different IP address, an Authentication Trap will be generated. If the IP address is set to 0.0.0.0, anyone may use this address, however, traps will not be sent since the address is invalid." ::= { commEntry 4 } commMACAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The physical address of the device receiving traps from the agent." ::= { commEntry 5 } commAccess OBJECT-TYPE SYNTAX INTEGER { noAccess(1), ro(2), rw(3), su(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Access code assiciated with the community name of the same entry. noAccess indicates a community name with zero privileges. ro has read-only access to MIB objects. rw allows you to read and write MIB objects. SU (super- user) gives you privileges to read and write any MIB object. The community table itself can only be written to with an access of SU as well as the setting of the IP Address on a device." ::= { commEntry 6 } -- -- The Unit Control Group -- unitRestart OBJECT-TYPE SYNTAX INTEGER { restart-unit(1), dummy-restart(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to a value of 1 will force the unit to restart. Setting this variable to any other value will cause an SNMP error. This variable always returns a value of 2." ::= { unitControlGroup 1 } dumpOnRestart OBJECT-TYPE SYNTAX INTEGER { dump-on-start(1), dont-dump(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to a value of 1 will force the unit to perform a dump on restart. Setting this variable to a value of 2 will force it to not to dump on restart." ::= { unitControlGroup 2 } initiateInstall OBJECT-TYPE SYNTAX INTEGER { start-install(1), dummy-install(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to a value of 1 will force the unit to initiate an install process. This variable always returns a value of 2." ::= { unitControlGroup 3 } initializeStats OBJECT-TYPE SYNTAX INTEGER { init-stats(1), dummy-init-stats(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to a value of 1 will force the unit to initialize (clear) SyncResearch proprietary statistics kept by the unit. This variable always returns a value of 2." ::= { unitControlGroup 4 } clearDump OBJECT-TYPE SYNTAX INTEGER { clear-dump-file(1), dummy-clear(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to a value of 1 will force the unit to clear a dump. This variable always returns a value of 2." ::= { unitControlGroup 5 } acknowledgeAllStatuses OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. When this field is set to yes, the unit will mark each of the various statuses in different levels as acknowledged. It will then re-consolidate without putting these statuses into consideration. Subseqent change of these statuses will cause the unit to include them in computing the status of the unit. Setting the object to no has no effect." ::= { unitControlGroup 6 } consolidatedUnitStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), normal (2), informational (3), disabled (4), marginal (5), warning (6), minor (7), major (8), critical (9) } ACCESS read-only STATUS mandatory DESCRIPTION "This object reports the consolidted status of the unit. All acknowledged element statuses and any element statuses specified as ignored by the user are ignored for unit level status computation." ::= { unitControlGroup 7 } homeDialBackup OBJECT-TYPE SYNTAX INTEGER { home-dial-backup (1), dummy-home (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to a value of 1 will force all dial backup lines to dedicated lines. Setting this variable to any other value will case an SNMP error. This variable always returns a value of 2." ::= { unitControlGroup 8 } -- -- Unit Status Group -- -- This group contains the device status variables. There exists -- only one instance of this group per unit. -- unitModel OBJECT-TYPE SYNTAX INTEGER { boundary(1), lic(2), chipcomPED(3), snacMIM(4), microMac(5), linkConverter (6), universal-boundary (7), universal-desktop (8), linkConverterII (9), ibm (10), sync3600(11), ibm3600(12) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable defines the base hardware model of the unit." ::= { unitStatusGroup 1 } softwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(1..6)) ACCESS read-only STATUS mandatory DESCRIPTION "The current version number of the operating software in xx.yyy where xx = major release, yyy = revision." ::= { unitStatusGroup 2 } productType OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The product type string returned is set in the MS.SYS file and defines the product name." ::= { unitStatusGroup 3 } maxPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of ports this unit can support (total number of serial access ports plus total number of LAN ports)." ::= { unitStatusGroup 4 } maxPU OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of PUs this unit can support (total number that can be configured)." ::= { unitStatusGroup 5 } maxSession OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of sessions this unit can support (total number that can be configured)." ::= { unitStatusGroup 6 } maxDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of devices this unit can support (total number that can be configured)." ::= { unitStatusGroup 7 } msBoardType OBJECT-TYPE SYNTAX INTEGER { not-expected(1), two-port-RS232(16), two-port-RS422(17), two-port-V35(18), v35-RS232(22), rs422-RS232(23), two-port-universal(26), two-port-iusc-RS232(30) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of serial I/O ports on main board. It returns 1 if not expected." ::= { unitStatusGroup 8 } msExtBoardType OBJECT-TYPE SYNTAX INTEGER { not-present(1), two-port-RS232(19), two-port-RS422(20), two-port-V35(21), two-port-hspeedRS232(24), two-port-hspeedV35(25), two-port-universal(27), four-port-universal(28), six-port-universal(29) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of serial I/O ports on extension board. It returns 1 if not present." ::= { unitStatusGroup 9 } dumpFileStatus OBJECT-TYPE SYNTAX INTEGER { none (1), dump-available(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the presence of a dump file." ::= { unitStatusGroup 10 } dumpFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..11)) ACCESS read-only STATUS mandatory DESCRIPTION "The dump file name." ::= { unitStatusGroup 11 } unitSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(1..9)) ACCESS read-only STATUS mandatory DESCRIPTION "The base unit serial number." ::= { unitStatusGroup 12 } expansionSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(1..9)) ACCESS read-only STATUS mandatory DESCRIPTION "The expansion board serial number." ::= { unitStatusGroup 13 } romVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(1..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The ROM version number." ::= { unitStatusGroup 14 } processorType OBJECT-TYPE SYNTAX INTEGER { i286 (1), i386 (2), i486SX (3), i486DX (4), i486DX-2 (5), i486DX-4 (6) } ACCESS read-only STATUS mandatory DESCRIPTION "The base unit processor type." ::= { unitStatusGroup 15 } chassisSlot OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "If the unit is a blade in a chassis, then this variable indicates the slot number. If not applicable, a value of 99 will be returned." ::= { unitStatusGroup 16 } lastTrapSeqNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the last sequence number of the last trap generated by the unit. When this value reaches its maximum, it then rolls back to 0." ::= { unitStatusGroup 17 } lastInstallErrCode OBJECT-TYPE SYNTAX INTEGER (0..9999) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the status of last install. If the last install was successful, 0 is returned, 9999 indicates installation is in progress, otherwise an error code is returned." ::= { unitStatusGroup 18 } unitPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(1..19)) ACCESS read-only STATUS mandatory DESCRIPTION "The base unit part number." ::= { unitStatusGroup 19 } expansionPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(1..19)) ACCESS read-only STATUS mandatory DESCRIPTION "The expansion board part number." ::= { unitStatusGroup 20 } wan1BoardType OBJECT-TYPE SYNTAX INTEGER { not-present(1), dsu-csu(31) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of serial I/O ports on extension board. It returns 1 if not present." ::= { unitStatusGroup 21 } wan2BoardType OBJECT-TYPE SYNTAX INTEGER { not-present(1), dsu-csu(31), isdn(32) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of serial I/O ports on extension board. It returns 1 if not present." ::= { unitStatusGroup 22 } patchId OBJECT-TYPE SYNTAX DisplayString (SIZE(1..4)) ACCESS read-only STATUS mandatory DESCRIPTION "The current patch identifier for the operating software. Either the three character Patch ID or 'None'" ::= { unitStatusGroup 23 } -- -- The Unit Configuration Group -- Contains the current operational configuration of the unit unitId OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the unit id. It consists of a 1 to 8 octet right justified case-sensitive ASCII field which uniquely identifies the unit. This ID is displayed on the LCD display if available, all system dumps, and any ASCII alarms. The defalult value for this field is startup." ::= { unitConfigGroup 1 } nmsSerialSpeed OBJECT-TYPE SYNTAX INTEGER { speed1200(12), speed2400(24), speed4800(48), speed9600(96), speed19200(192) } ACCESS read-only STATUS mandatory DESCRIPTION "The async serial port speed for NMS console port. The speed is expressed in bits per second (i.e. 9.6 Kbps is represented as 96 decimal). Currently supported speeds are: 1200 2400 4800 9600 19200 Default speed is 9600 bits per second." ::= { unitConfigGroup 2 } serialPortLogoffTimer OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-only STATUS mandatory DESCRIPTION "Units are minutes. Default value is 0, indicating that no timer is active." ::= { unitConfigGroup 3 } callRetryTimer OBJECT-TYPE SYNTAX INTEGER (2..999) ACCESS read-only STATUS mandatory DESCRIPTION "The call retry timer (a.k.a Session Retry Timer). The number of seconds to wait before trying to retry a failed connection attempt. Currently supported values are 2 - 999 seconds. The default is 30 seconds." ::= { unitConfigGroup 4 } password OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "The unit's password. This field indicates the system password used to log into the unit for operating the NMS interface. This field is a one to eight byte case-sensitive left justified ASCII data field and may not be left blank. The default value is 'sri' (for Sync Research Inc.), or 'ctron' for Cabletron products." ::= { unitConfigGroup 5 } configPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "The configuration password. This field indicates the password used to enter the configuration subsystem. This field is a one to eight byte case-sensitive left justified ASCII data field and may not be left blank. The default value is 'sri' (for Sync Research Inc.), or 'ctron' for Cabletron products." ::= { unitConfigGroup 6 } dateTimeField OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-write STATUS mandatory DESCRIPTION "The date and time. This field is stored as 6 bytes of BCD Data in the following order: Month: 0x01 - 0x12 Day: 0x01 - 0x31 Year: 0x00 - 0x99 Hour: 0x00 - 0x23 Minute: 0x00 - 0x59 Second: 0x00 - 0x59" ::= { unitConfigGroup 7 } configId OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The configuration identifer. This field is the configuration ID assigned when a new configuration is activated. first time. It is assigned by the unit or a Sync Research management product (SyncMan) automatically and is not user assignable." ::= { unitConfigGroup 8 } internalMacAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "Embedded conversion node MAC address. Applicable to Frame Node only." ::= { unitConfigGroup 9 } internalRingNumber OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "Embedded conversion node ring number. This should be unique within the network. Applicable to Frame Node only." ::= { unitConfigGroup 10 } internalBridgeNumber OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Embedded conversion node bridge number. This parameter is currently not used. Applicable to Frame Node only." ::= { unitConfigGroup 11 } internalMacAddress2 OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "Optional second embedded conversion node MAC address. Applicable to Frame Node only." ::= { unitConfigGroup 12 } internalRingNumber2 OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "Optional second embedded conversion node ring number. This should be unique within the network. Applicable to Frame Node only." ::= { unitConfigGroup 13 } associatedPortNumber2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Assigns the physical port number corresponding to the virtual port that the second embedded conversion node is associated with. Applicable to Frame Node only." ::= { unitConfigGroup 14 } associatedDLCI2 OBJECT-TYPE SYNTAX INTEGER (0..1023) ACCESS read-only STATUS mandatory DESCRIPTION "Assigns the Frame Relay PVC number corresponding to the virtual port that the second embedded conversion node is associated with. Applicable to Frame Node only." ::= { unitConfigGroup 15 } internalMacAddress3 OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "Optional third embedded conversion node MAC address. Applicable to Frame Node only." ::= { unitConfigGroup 16 } internalRingNumber3 OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "Optional third embedded conversion node ring number. This should be unique within the network. Applicable to Frame Node only." ::= { unitConfigGroup 17 } associatedPortNumber3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Assigns the physical port number corresponding to the virtual port that the third embedded conversion node is associated with. Applicable to Frame Node only." ::= { unitConfigGroup 18 } associatedDLCI3 OBJECT-TYPE SYNTAX INTEGER (0..1023) ACCESS read-only STATUS mandatory DESCRIPTION "Assigns the Frame Relay PVC number corresponding to the virtual port that the third embedded conversion node is associated with. Applicable to Frame Node only." ::= { unitConfigGroup 19 } internalMacAddress4 OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "Optional forth embedded conversion node MAC address. Applicable to Frame Node only." ::= { unitConfigGroup 20 } internalRingNumber4 OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "Optional forth embedded conversion node ring number. This should be unique within the network. Applicable to Frame Node only." ::= { unitConfigGroup 21 } associatedPortNumber4 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Assigns the physical port number corresponding to the virtual port that the forth embedded conversion node is associated with. Applicable to Frame Node only." ::= { unitConfigGroup 22 } associatedDLCI4 OBJECT-TYPE SYNTAX INTEGER (0..1023) ACCESS read-only STATUS mandatory DESCRIPTION "Assigns the Frame Relay PVC number corresponding to the virtual port that the forth embedded conversion node is associated with. Applicable to Frame Node only." ::= { unitConfigGroup 23 } ipInactivityTimer OBJECT-TYPE SYNTAX INTEGER (1..3600) ACCESS read-only STATUS mandatory DESCRIPTION "This timer is used for IP/SNMP over X25 support. It is the inactivity timer for an IP connection. If there is no activity for an IP session for the time this field specifies, IP will clear the session. The timer is expressed in seconds and is defaulted to 90." ::= { unitConfigGroup 24 } excessBurstGovernor OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter configuration determines whether the FrameNode should limit the throughput on a per PVC basis to the configured Excess Burst Size (in the excess burst measure time period Tc). The range of this parameter is YES or NO. Default value is NO" ::= { unitConfigGroup 25 } measurementPeriod OBJECT-TYPE SYNTAX INTEGER (1..5) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the time period for calculating Excess Burst for Frame Relay ports. The range of this parameter is 1 second to 5 seconds. Default is 1 second." ::= { unitConfigGroup 26 } markDEBit OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies whether the FrameNode marks frames with the DE bit. The range of this parameter is YES or NO. Default is YES. If the parameter is set to YES, the FrameNode marks the frames with the DE bit (for a non-urgent priority traffic) if a port's used bandwidth value is greater than the configured bandwidth." ::= { unitConfigGroup 27 } -- -- The Unit Statistics Group -- numberSamples OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of internal system level samples performed. Samples are taken every 10th of a second." ::= { unitStatisticsGroup 1 } systemBufferFreeCounts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average number of system buffers free in the system during the system sample period. The number of available buffers varies by system type and configuration. To determine the maximum number of buffers for a given configuration, view a sample when there is no activity in the unit. A heavily loaded unit will display a small number of available buffers and low Processor Idle counts." ::= { unitStatisticsGroup 2 } cpuIdleSumCounts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The main processor average idle sum count. This is the average number of times the idle counter was incremented over the sampling period divided by 1000. This is an absolute value of performance as does not vary by performance. A heavily loaded unit will display a small number of available buffers and low Processor Idle counts." ::= { unitStatisticsGroup 3 } -- -- NetView PU Status Group -- -- This group contains status variables. There exists -- only one instance of this group per unit. -- netviewConnectionStatus OBJECT-TYPE SYNTAX INTEGER { connected(1), not-connected(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the Primary Netview Connection." ::= { netViewPUStatusGroup 1 } netviewLastClearCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "A two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed primary NetView connection attempt (a.k.a. call attempt) or Netview active connection (a.k.a. session). For LLC type 2 connections the first octet (cause) is always 0. The second octet (diagnostic) indicates the reason for the last connection failure. The second octet is set to 0 when a sucessful call has been placed, or if no call has ever been placed (e.g. PU never came up). If the second octet is non-zero then it indicates the reason for the connection attempt failure. See current product documentation for list of possible values." ::= { netViewPUStatusGroup 2 } netviewAltConnectionStatus OBJECT-TYPE SYNTAX INTEGER { connected(1), not-connected(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the alternate Netview Connection" ::= { netViewPUStatusGroup 3 } netviewAltLastClearCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "A two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed alternate NetView connection attempt (a.k.a. call attempt) or Netview active connection (a.k.a. session). For LLC type 2 connections the first octet (cause) is always 0. The second octet (diagnostic) indicates the reason for the last connection failure. The second octet is set to 0 when a sucessful call has been placed, or if no call has ever been placed (e.g. PU never came up). If the second octet is non-zero then it indicates the reason for the connection attempt failure. See current product documentation for list of possible values." ::= { netViewPUStatusGroup 4 } netviewConnectionAttemptCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of connection attempts performed on the Primary NetView PU. This count is set to zero at startup, and after every loss of an estabished session." ::= { netViewPUStatusGroup 5 } netviewAltConnectionAttemptCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of connection attempts performed on the Alternate NetView PU. This count is set to zero at startup, and after every loss of an estabished session." ::= { netViewPUStatusGroup 6 } netviewStatusIgnored OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. The status of this netview pu is not put into consideration when consolidating status of the unit if this field is set to yes." ::= { netViewPUStatusGroup 7 } netviewStatusAcknowledged OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. When this field is set to yes, the unit will re-consolidate its status without putting the status of this netview PU into consideration. Subseqent status change of the this netview PU will cause the unit to include it in computing the status of the unit. Setting the value to no has no effect." ::= { netViewPUStatusGroup 8 } netviewAltStatusIgnored OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. The status of this netview pu is not put into consideration when consolidating status of the unit if this field is set to yes." ::= { netViewPUStatusGroup 9 } netviewAltStatusAcknowledged OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. When this field is set to yes, the unit will re-consolidate its status without putting the status of this netview pu into consideration. Subseqent status change of the this netview pu will cause the unit to include it in computing the status of the unit. Setting the value to no has no effect." ::= { netViewPUStatusGroup 10 } -- -- The NetView PU Configuration Group -- Contains the current operational configuration -- netviewPUXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Primary NetView PU XID. This field indicates the XID data to be sent to the host for establishing Netview Session. This field is a maximum four byte hexadecimal data field. This field should be set to all zeroes if no Netview session is to be established. The default value is all zeroes." ::= { netViewPUConfigGroup 1 } alternateNetviewPUXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Alternate NetView PU XID. This field indicates the XID data to be sent to the host for establishing Netview Session. This field is a maximum four byte hexadecimal data field. This field should be set to all zeroes if no Netview session is to be established. The default value is all zeroes." ::= { netViewPUConfigGroup 2 } netviewConnectID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The primary NetView PU connection ID. The default value is 0." ::= { netViewPUConfigGroup 3 } alternateNetviewConnectID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The alternate NetView PU connection ID. The default value is 0." ::= { netViewPUConfigGroup 4 } netviewSpecialConnect OBJECT-TYPE SYNTAX INTEGER { answer (1), originate (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The primary NetView PU connection type. The default value is originate." ::= { netViewPUConfigGroup 5 } alternateNetviewSpecialConnect OBJECT-TYPE SYNTAX INTEGER { answer (1), originate (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The alternate NetView PU connection type. The default value is originate." ::= { netViewPUConfigGroup 6 } -- -- The Bridge Configuration Group -- Contains the current operational configuration -- brEnableBridging OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This flag indicates if bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'No'" ::= { bridgeConfigGroup 1 } bridgePriority OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Sometimes referred to as the ROOT id. Determines the priority component of the Bridge identifier used in determining the Root Bridge for a spanning tree network." ::= { bridgeConfigGroup 2 } brMaxAge OBJECT-TYPE SYNTAX INTEGER (6..40) ACCESS read-only STATUS mandatory DESCRIPTION "The time at which a configuration message is descarded. Units are in seconds. Default value is 10 seconds" ::= { bridgeConfigGroup 3 } brHelloTimer OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-only STATUS mandatory DESCRIPTION "The time interval between issuing configuration messages. Units are seconds. Default value is 2 seconds" ::= { bridgeConfigGroup 4 } brFilterIPX OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all IPX frames are filtered (if bridge is enabled). Default is no." ::= { bridgeConfigGroup 5 } brFilterIP OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all IP frames are filtered (if bridging is enabled). Default is no." ::= { bridgeConfigGroup 6 } brFilterNetBIOS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all NetBIOS frames are filtered (if bridging is enabled). Default is no." ::= { bridgeConfigGroup 7 } brFilterLLC2 OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all LAN attached SNA LLC2 frames are filtered (if bridging is enabled). Default is no." ::= { bridgeConfigGroup 8 } brFilterSMAN OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all SyncManager LLC2 frames are filtered (if bridging is enabled). Default is no." ::= { bridgeConfigGroup 9 } brForwardOther OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If set to yes, all other frames are forwarded (if bridging is enabled). Default is No." ::= { bridgeConfigGroup 10 } brIPXtargetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If IPX filtering is set to no, then this parameter defines a specific FR port to deliver IPX frames to. Used in conjunction with brIPXtargetDLCI. The valid range is 0 to 5. A value of 0 indicates that the IPX target port/DLCI is not configured. This field has the default value of 0." ::= { bridgeConfigGroup 11 } brIPXtargetDLCI OBJECT-TYPE SYNTAX INTEGER (0..1023) ACCESS read-only STATUS mandatory DESCRIPTION "If IPX filtering is set to no, then this parameter defines a specific FR DLCI to deliver IPX frames to. Used in conjunction with brIPXtargetPort. If the value of brIPXtargetport is 0, then the value of brIPXtargetDLCI is not significant." ::= { bridgeConfigGroup 12 } brIPtargetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If IP filtering is set to no, then this parameter defines a specific FR port to deliver IP frames to. Used in conjunction with brIPtargetDLCI. The valid range is 0 to 5. A value of 0 indicates that the IP target port/DLCI is not configured. This field has the default value of 0." ::= { bridgeConfigGroup 13 } brIPtargetDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If IP filtering is set to no, then this parameter defines a specific FR DLCI to deliver IP frames to. Used in conjunction with brIPtargetPort. If the value of brIPtargetport is 0, then the value of brIPtargetDLCI is not significant." ::= { bridgeConfigGroup 14 } brNetBIOStargetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If NetBIOS filtering is set to no, then this parameter defines a specific FR port to deliver NetBIOS frames to. Used in conjunction with brNetBIOStargetDLCI. The valid range is 0 to 5. A value of 0 indicates that the NetBIOS target port/DLCI is not configured. This field has the default value of 0." ::= { bridgeConfigGroup 15 } brNetBIOStargetDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If NetBIOS filtering is set to no, then this parameter defines a specific FR DLCI to deliver NetBIOS frames to. Used in conjunction with brNetBIOStargetPort. If the value of brNetBIOStargetport is 0, then the value of brNetBIOStargetDLCI is not significant." ::= { bridgeConfigGroup 16 } brLLC2targetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If SNA LLC2 filtering is set to no, then this parameter defines a specific FR port to deliver LLC2 frames to. Used in conjunction with brLLC2targetDLCI. The valid range is 0 to 5. A value of 0 indicates that the brLLC2targetport/brLLC2targetDLCI is not configured. This field has the default value of 0." ::= { bridgeConfigGroup 17 } brLLC2targetDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If SNA LLC2 filtering is set to no, then this parameter defines a specific FR DLCI to deliver LLC2 frames to. Used in conjunction with brLLC2targetPort. If the value of brLLC2targetport is 0, then the value of brLLC2targetDLCI is not significant." ::= { bridgeConfigGroup 18 } brOthertargetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If Other forwarding is set to yes, then this parameter defines a specific FR port to deliver Other frames to. Used in conjunction with brOthertargetDLCI. The valid range is 0 to 5. The value 0 indicates that the brOthertargetport/brOthertargetDLCI is not configured. This field has the default value of 0." ::= { bridgeConfigGroup 19 } brOthertargetDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "If Other forwarding is set to yes, then this parameter defines a specific FR DLCI to deliver Other frames to. Used in conjunction with brOthertargetPort. If the value of brOthertargetport is 0, then the value of brOthertargetDLCI is not significant." ::= { bridgeConfigGroup 20 } brSerialPriority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of serial attached port traffic." ::= { bridgeConfigGroup 21 } brTerminatedLLC2Priority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of terminated LLC2 traffic." ::= { bridgeConfigGroup 22 } brLLC2Priority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of SNA LLC2 traffic." ::= { bridgeConfigGroup 23 } brIPXPriority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of IPX traffic." ::= { bridgeConfigGroup 24 } brIPPriority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of IP traffic." ::= { bridgeConfigGroup 25 } brNetBIOSPriority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of NetBIOS traffic." ::= { bridgeConfigGroup 26 } brOtherPriority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the transmit priority for Frame Relay of other traffic." ::= { bridgeConfigGroup 27 } brHighPriorityBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the high priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 40." ::= { bridgeConfigGroup 28 } brMediumPriorityBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the medium priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 30." ::= { bridgeConfigGroup 29 } brLowPriorityBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the low priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 20." ::= { bridgeConfigGroup 30 } brDelayTimer OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "This field, expressed in seconds, specifies the maximum number of seconds a bridge frame can live in the unit. If a bridge frame stays in the unit longer than this value, the frame will be tossed. The default value for this field is 1" ::= { bridgeConfigGroup 31 } brEnableIPXBridging OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This flag indicates if IPX bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'Yes'" ::= { bridgeConfigGroup 32 } brEnableIPBridging OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This flag indicates if IP bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'Yes'" ::= { bridgeConfigGroup 33 } brEnableNetBiosBridging OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This flag indicates if NetBios bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'Yes'" ::= { bridgeConfigGroup 34 } brEnableSNABridging OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This flag indicates if SNA bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'Yes'" ::= { bridgeConfigGroup 35 } brEnableSyncManBridging OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This flag indicates if Sync/Man bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'Yes'" ::= { bridgeConfigGroup 36 } brEnableOtherBridging OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This flag indicates if any other traffic bridging is to be performed on this unit. Applicable to Frame Nodes only. The default value for this field is 'No'" ::= { bridgeConfigGroup 37 } -- -- Bridge stats group -- ipxStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF IpxStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for reporting statistics for bridging." ::= { bridgeStatsGroup 1 } ipxStatsEntry OBJECT-TYPE SYNTAX IpxStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of IPX bridging statistics for each bridge port." INDEX { ipxStatsIndex } ::= { ipxStatsTable 1 } IpxStatsEntry ::= SEQUENCE { ipxStatsIndex INTEGER, ipxRipRcvdFwdInterval Counter, ipxRipRcvdFiltInterval Counter, ipxSapRcvdFwdInterval Counter, ipxSapRcvdFiltInterval Counter } ipxStatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number that uniquely identifies this IPX bridge port." ::= { ipxStatsEntry 1 } ipxRipRcvdFwdInterval OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the number of IPX RIP packets received on this port during the RIP forwarding interval. These packets were accepted by the port." ::= { ipxStatsEntry 2 } ipxRipRcvdFiltInterval OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the number of IPX RIP packets received on this port during the RIP filtering interval. These packets were tossed by the port." ::= { ipxStatsEntry 3 } ipxSapRcvdFwdInterval OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the number of IPX SAP packets received on this port during the SAP forwarding interval. These packets were accepted by the port." ::= { ipxStatsEntry 4 } ipxSapRcvdFiltInterval OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the number of IPX SAP packets received on this port during the SAP filtering interval. These packets were tossed by the port." ::= { ipxStatsEntry 5 } -- -- The IPX Configuration Group -- Contains the current operational configuration -- ipxEnableRouting OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter determines whether or not IPX Routing is enabled. Thr range of this parameter is yes or no. If set to yes, the parameter 'Filter IPX' should be set to yes. The default value for this field is 'No'" ::= { ipxConfigGroup 1 } ipxRoutedTxPriority OBJECT-TYPE SYNTAX INTEGER { urgent (1), high (2), medium (3), low (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter governs the transmission priority of the routed IPX frames for Frame Relay port(s). The range is URGENT, HIGH, MEDIUM AND LOW. The default is set to 'High'." ::= { ipxConfigGroup 2 } ipxEnableRipBroadcast OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter governs whether the framenode should send RIP packets or not. The range of this parameter is YES or NO. If IPX routing is disabled, this parameter is ignored. The default value for this field is 'Yes'" ::= { ipxConfigGroup 3 } ipxEnableSapBroadcast OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter governs whether the framenode should send SAP packets. The range of this parameter is YES or NO. If IPX routing is disabled, this parameter is ignored. The default value for this field is 'Yes'" ::= { ipxConfigGroup 4 } ipxEnableNetBIOS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter governs whether the frame Node should process NetBIOS packets or not. The range of this parameter is Yes or No. If IPX Routing is disabled, this parameter is ignored. Default is Yes." ::= { ipxConfigGroup 5 } ipxGlobalNodeId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-only STATUS mandatory DESCRIPTION " By default FrameNode always implements IPX WAN over Frame Relay. The 'timer request' packet is transmitted by the FrameNode over Frame Relay. This packet includes a field call WAN Node (referred to as WNode ID). This parameter defines the Wnode ID field. This field is 4 hexadecimal bytes (8 characters) long. This field is used in determining the MASTER and SLAV relationship between two end points. If IPX routing is enabled, this field needs to be configured for proper operation of IPX routing over Frame Relay. This value should be unique in the network. Default is undefined." ::= { ipxConfigGroup 6 } -- -- The IP Configuration Group -- Contains the current operational configuration -- priIPHelperAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the Primary IP Helper Address of this unit." ::= { ipConfigGroup 1 } secIPHelperAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the Secondary IP Helper Address of this unit." ::= { ipConfigGroup 2 } internalIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The range of this parameter and the default value is same as other IP Address in the unit." ::= { ipConfigGroup 3 } internalIPNetmask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the Internal IP network mask." ::= { ipConfigGroup 4 } enableIpRouting OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the Internal IP network mask." ::= { ipConfigGroup 5 } enableIpBridging OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the Internal IP network mask." ::= { ipConfigGroup 6 } enableRipBroadcast OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the Internal IP network mask." ::= { ipConfigGroup 7 } -- -- The LAN control -- lanControlTable OBJECT-TYPE SYNTAX SEQUENCE OF LanControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for controlling LAN ports and obtaining information." ::= { lanControlGroup 1 } lanControlEntry OBJECT-TYPE SYNTAX LanControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular LAN port." INDEX { lanControlIndex } ::= { lanControlTable 1 } LanControlEntry ::= SEQUENCE { lanControlIndex INTEGER, lanControlType INTEGER, lanStatus INTEGER, lanControlFailureCode OCTET STRING, lanControlNAUName DisplayString, lanStatusIgnored INTEGER, lanStatusAcknowledged INTEGER } lanControlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number that uniquely identifies this LAN port. Currently only one LAN port per unit is supported." ::= { lanControlEntry 1 } lanControlType OBJECT-TYPE SYNTAX INTEGER { token-ring-type(21), ethernet-type(17) } ACCESS read-only STATUS mandatory DESCRIPTION "The LAN type. Token-Ring ports run the IEEE 802.5 protocol. Ethernet-type run the IEEE 802.3 and Ethernet Version 2. Other LAN protocols may be added in the future." ::= { lanControlEntry 2 } lanStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), failed(3), restart(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the port. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. Commands: An enable command will attempt to bring up the LAN. An enable all command will perform the same function as enable, since there are no sub elements on a LAN. A disable command will disable the LAN. Status: Enable(d) indicates the LAN is enabled and running. Disable(d) indicates the LAN has been disabled. Failed indicates the LAN is enabled and not Running." ::= { lanControlEntry 3 } lanControlFailureCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the failure codes if the associated LAN interface is in the failed state." ::= { lanControlEntry 4 } lanControlNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { lanControlEntry 5 } lanStatusIgnored OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. The status of this LAN is not put into consideration when consolidating status of the unit if this field is set to yes." ::= { lanControlEntry 6 } lanStatusAcknowledged OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. When this field is set to yes, the unit will re-consolidate its status without putting the status of this LAN into consideration. Subseqent status change of the LAN will cause the unit to include it in computing the status of the unit. Setting this value to no has no effect." ::= { lanControlEntry 7 } -- -- The LAN Configuration Group -- lanPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LanPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of LAN information." ::= { lanTokenRingGroup 1 } lanPortEntry OBJECT-TYPE SYNTAX LanPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular LAN port." INDEX { lanPortIndex } ::= { lanPortTable 1 } LanPortEntry ::= SEQUENCE { lanPortIndex INTEGER, lanPortType INTEGER, lanMACAddress PhysAddress, lanPROMMACAddress PhysAddress, lanSpeed INTEGER, lanT1Timer INTEGER, lanT2Timer INTEGER, lanTiTimer INTEGER, lanRxWindowSize INTEGER, lanTxWindowSize INTEGER, lanMaxRetries INTEGER, lanRingNumber INTEGER, lanBridgeNumber INTEGER, lanEthernetFrameFormat INTEGER, lanSendLocalTest INTEGER, lanBroadcastType INTEGER, lanIPAddress IpAddress, lanNetworkMask IpAddress, lanDefaultGateway IpAddress, lanNAUName DisplayString, lanInterfaceType INTEGER, lanIPEthernetFrameType INTEGER, lanInitState INTEGER, lanSecondDefaultGateway IpAddress, lanRIPUpdtTimer INTEGER, lanRIPAge INTEGER, lanSAPUpdtTimer INTEGER, lanSAPAge INTEGER, lanRSM INTEGER } lanPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port. Currently only one LANtoken ring port per unit is supported." ::= { lanPortEntry 1 } lanPortType OBJECT-TYPE SYNTAX INTEGER { token-ring-type(21), ethernet-type(17) } ACCESS read-only STATUS mandatory DESCRIPTION "The LAN port type." ::= { lanPortEntry 2 } lanMACAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The user configured LANtoken ring MAC address. If the address is set to 0 then the burned-in Address is used. This field contains a user configured address if any. If a user configured address is desired, then it must be configured as a valid individual, user defined - MAC address. The address must be configured in the native format convention used by the LAN port. For token Ring LAN ports the address follows User configured addresses must follow IEEE 802.5 IEEE 802.5 rules (most significant bit transmitted first) and must be between 400000000000 and 7FFFFFFFFFFF hexadecimal inclusive. For Ethernet LAN ports the format is must follow IEEE 802.3 rules.where the two least significant bits of the first octet must be zero. This means the first octet must be in the set of numbers 0x00, 0x04, 0x08, ... 0xFC..... The Default Value for this field is all zeroes." ::= { lanPortEntry 3 } lanPROMMACAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The burned in MAC address. This is the MAC address assigned by the factory when the unit is shipped. If the User configured address is set to 0, then this will be the address used by the adapter for the source address field for all frames sent by the LAN adapter. The format ordering of bits is as defined in IEEE 802.5. This ordering is where the Most Significant Bit is transmitted first. This is different from other protocols (e.g. 802.3) where the least significant bit is transmitted first. The representation of the MAC address is in the format native for the LAN port. Boundary platform Token-Ring LAN ports start with the first six digits (three octects) equal to 0002F6 which indicates a Sync Research Token Ring MAC address. Boundary platform Ethernet LAN ports start with the first six digits (three octects) equal to to 00406F which indicates a Sync Research Ethernet MAC address. This field is not changable via any commands and will always contain the manufactured MAC address for the LAN port." ::= { lanPortEntry 4 } lanSpeed OBJECT-TYPE SYNTAX INTEGER { speed-4Mbs(4), speed-10Mbs(10), speed-16Mbs(16) } ACCESS read-only STATUS mandatory DESCRIPTION "The LAN port speed in Megabits/second." ::= { lanPortEntry 5 } lanT1Timer OBJECT-TYPE SYNTAX INTEGER (1..25) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC T1 timer value in seconds. T1 should be greater than T2 and less than Ti. Currently supported values are 1 to 25 seconds. The default value for this field is 3 seconds." ::= { lanPortEntry 6 } lanT2Timer OBJECT-TYPE SYNTAX INTEGER (0..50) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC T2 timer value in tenths of seconds. If configured for 0 then the T2 timer is disabled and an RR frame will be sent for every I frame received. Current supported values are 0 and 2-50. T2 should be less than T1. The default value for this field is 0 (disabled)." ::= { lanPortEntry 7 } lanTiTimer OBJECT-TYPE SYNTAX INTEGER (2..50) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC Ti (inactivity) timer value in seconds. Ti should be greater than T1. Currently supported values are 2 to 50 seconds. The default value for this field is 30 seconds." ::= { lanPortEntry 8 } lanRxWindowSize OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC receive window (N3) size. Note that this is not the same receive window as defined in IEEE 802.2 LLC. This is N3 which is the number of I frames received before an RR frame is sent (defined as N3 in IEEE 802.2 LLC). Current allowable values are 1-15. The default value for this field is 7." ::= { lanPortEntry 9 } lanTxWindowSize OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "The defalut LLC transmit window size. Current allowable values are 1-15. The default value for this field is 7." ::= { lanPortEntry 10 } lanMaxRetries OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC maximum number of retries (N2 value). Current allowable values are 1-99. The default value for this field is 3." ::= { lanPortEntry 11 } lanRingNumber OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "802.5 bridging parameter. This variable returns a value of 0, if it is not defined. This value is configured in hex from 0 to FFF. This value is not applicable to Ethernet." ::= { lanPortEntry 12 } lanBridgeNumber OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "802.5 bridging parameter. The default value for this field is 1. This value is not applicable to Ethernet." ::= { lanPortEntry 13 } lanEthernetFrameFormat OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), e802-3-type(2), ethernet-type-2(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The Ethernet frame format used on this LAN. The default value for this field is 802.3. Not used if Token Ring, and 1 is returned." ::= { lanPortEntry 14 } lanSendLocalTest OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), yes(2), no(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This port's send local test option. Identifies whether a test frame should be sent on the local ring to discover a destination MAC address. If all destinations for the unit are located on a remote ring, setting this field to No allows the unit to bypass discovery of a destination MAC address on the local ring. If this field is set to 'No' then the broadcastType field must be set to all routes or single route broadcast. If the any destination is on a local ring or unknown, this parameter should be set to 'Yes'. The default value for this field is 'Yes'. Not used if Ethernet, and 0 is returned." ::= { lanPortEntry 15 } lanBroadcastType OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), none-bc(2), all-bc(3), single-bc(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This port's broadcast type. Not used if Ethernet. Types are: none, all-routes, and single-route. Identifies the form of a broadcast test frame sent to discover the route to a destination MAC address. If all destinations are located on the local ring, this field may be set to 'None' to prevent a broadcast search for a destination MAC address. If set to 'None', then the sendLocalTest field must be set to 'Yes'. If set as 'All-routes', the unit will send an All-routes broadcast TEST command frame and expect a non-broadcast TEST response frame in return. If set to Single-route, the unit will send a Single-route broadcast TEST command frame and expect a all-routes TEST response frame in return. The default for this field is all routes broadcast. Not used if Ethernet, and 0 is returned." ::= { lanPortEntry 16 } lanIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the IP Address of this interface." ::= { lanPortEntry 17 } lanNetworkMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the network mask to be used on this interface." ::= { lanPortEntry 18 } lanDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Default gateway address to be used when sending responses on this interface." ::= { lanPortEntry 19 } lanNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { lanPortEntry 20 } lanInterfaceType OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), aui(2), bnc(3), utp(4), stp(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This port's physical interface type. Only used if Ethernet. The default for this field is utp. Not used if Token Ring, and 1 is returned." ::= { lanPortEntry 21 } lanIPEthernetFrameType OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), e802-3-type(2), ethernet-type-2(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The IP Ethernet frame format used on this LAN for IP frames. The default value for this field is 802.3. Not used if Token Ring, and 1 is returned." ::= { lanPortEntry 22 } lanInitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the LAN port. If configured for 'in-service', then the LAN port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the LAN port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'." ::= { lanPortEntry 23 } lanSecondDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Second Default gateway address to be used when sending responses on this interface." ::= { lanPortEntry 24 } lanRIPUpdtTimer OBJECT-TYPE SYNTAX INTEGER (10..180) ACCESS read-only STATUS mandatory DESCRIPTION "Defines frequency at which the RIP packets are sent over this interface. The range of this parameter is from 10 seconds to 180 seconds. A value of 0 implies no RIP is sent over this interface. Default value is 60 seconds" ::= { lanPortEntry 25 } lanRIPAge OBJECT-TYPE SYNTAX INTEGER (40..540) ACCESS read-only STATUS mandatory DESCRIPTION "Defines frequency at which the learned RIP entries are removed if not corresponding RIP update is received. The range of this parameter is from 40 seconds to 540 seconds. Default value is 180 seconds" ::= { lanPortEntry 26 } lanSAPUpdtTimer OBJECT-TYPE SYNTAX INTEGER (0..180) ACCESS read-only STATUS mandatory DESCRIPTION "Defines frequency at which the SAP packets are sent over this interface. The range of this parameter is from 10 seconds to 180 seconds. A value of 0 implies that no SAP broadcasts are sent over this interface. Default value is 60 seconds" ::= { lanPortEntry 27 } lanSAPAge OBJECT-TYPE SYNTAX INTEGER (40..720) ACCESS read-only STATUS mandatory DESCRIPTION "Defines frequency at which the learned SAP entries are removed if not corresponding SAP update is received. The range of this parameter is from 40 seconds to 720 seconds. Default value is 180 seconds" ::= { lanPortEntry 28 } lanRSM OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Routing Summary Information parameter indicates whether the routing summary information should be generated in the RIP on that interface. If RSM is set to NO, RIP will broadcast subnet information as it is defined in the routing table. Default value is 'NO'" ::= { lanPortEntry 29 } -- -- The Line Control Group -- lineControlTable OBJECT-TYPE SYNTAX SEQUENCE OF LineControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for controlling lines and obtaining information." ::= { lineControlGroup 1 } lineControlEntry OBJECT-TYPE SYNTAX LineControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular port." INDEX { lineControlIndex } ::= { lineControlTable 1 } LineControlEntry ::= SEQUENCE { lineControlIndex INTEGER, lineControlType INTEGER, lineStatus INTEGER, lineControlFailureCode OCTET STRING, lineControlNAUName DisplayString, lineStatusIgnored INTEGER, lineStatusAcknowledged INTEGER, loopbackTest INTEGER } lineControlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port." ::= { lineControlEntry 1 } lineControlType OBJECT-TYPE SYNTAX INTEGER { hbsc-type(1), tbsc-type(2), x25dte-type(7), x25dce-type(8), hasc-type(9), tasc-type(10), hsdlc-type(11), tsdlc-type(12), frameRelay-type(19), dial-backup-type(20), secondaryRJE-type(13), primaryRJE-type(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU. TBSC (Terminal Bisync) ports emulate a Host and poll the downstream CUs (e.g. 3274 or ATM Bisync controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (CUs) and respond to polls from the Host or upstream CU. Frame Relay ports support Frame Relay PVC. X25 type is for either X.25 packet level DCE or DTE." ::= { lineControlEntry 2 } lineStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), failed(3), restart(4), enable-all(5), not-in-use(6) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the port. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. When calculating consolidated status for the unit, if the line status set to not-in-use then this port is not included. Commands: An enable command will attempt to bring up the line. An enable all command will attempt to bring up the line and any lower layer entities (e.g. PUs). A disable command will disable the line. Status: Enable(d) indicates the line is enabled and running. Disable(d) indicates the line has been disabled. Failed indicates the line is enabled and not Running." ::= { lineControlEntry 3 } lineControlFailureCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the failure codes if the associated port interface is in the failed state." ::= { lineControlEntry 4 } lineControlNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { lineControlEntry 5 } lineStatusIgnored OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. The status of this line is not put into consideration when consolidating status of the unit if this field is set to yes." ::= { lineControlEntry 6 } lineStatusAcknowledged OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. When this field is set to yes, the unit will re-consolidate its status without putting the status of this line into consideration. Subseqent status change of the line will cause the unit to include it in computing the status of the unit. Setting this value to no has no effect." ::= { lineControlEntry 7 } loopbackTest OBJECT-TYPE SYNTAX INTEGER { local (1), network-or-full (2), remote (3), stop-test(4), passive (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Loopback Test can be supported on both DSU/CSU and ISDN. Loopback can be local, Network, or Remote. Local loopback means outgoing serial data is looped back toward DTE device. Network loopback triggers the local node to loopback any incoming serial data back to the network. Remote loopback triggers the far end node to loopback any serial data received from the network. A local loopback test is stopped by entering a Ctrl-C." ::= { lineControlEntry 8 } -- -- The Line Physical Control Group -- -- This is a separate group as not all 'lines' have an RS-232 -- or other WAN physical interface (e.g. V.35, RS-449 etc.) -- This group is for reporting EIA status for the STM command. -- linePhysicalTable OBJECT-TYPE SYNTAX SEQUENCE OF LinePhysicalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for obtaining physical signal status information." ::= { linePhysicalGroup 1 } linePhysicalEntry OBJECT-TYPE SYNTAX LinePhysicalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular port." INDEX { linePhysicalIndex } ::= { linePhysicalTable 1 } LinePhysicalEntry ::= SEQUENCE { linePhysicalIndex INTEGER, linePhysicalType INTEGER, lineEIAStatus INTEGER, lineQualityFrameCount Counter, lineQualityCRCErrors Counter, lineQualityAborts Counter, lineInterfaceType INTEGER, lineCableType INTEGER, lineSwitchedConnection INTEGER } linePhysicalIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port." ::= { linePhysicalEntry 1 } linePhysicalType OBJECT-TYPE SYNTAX INTEGER { hbsc-type(1), tbsc-type(2), x25dte-type(7), x25dce-type(8), tasc-type(9), hasc-type(10), frameRelay-type(19), hsdlc-type(11), tsdlc-type(12), dial-backup-type(20), secondaryRJE-type(13), primaryRJE-type(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU. TBSC (Terminal Bisync) ports emulate a Host and poll the downstream CUs (e.g. 3274 or ATM Bisync controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (CUs) and respond to polls from the Host or upstream CU. Frame Relay ports support Frame Relay PVC." ::= { linePhysicalEntry 2 } lineEIAStatus OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A port's current control signal status. All SDLC ports have the ability to read the current status of RS-232 or equivalent control signals. The value returned is a 16 bit value where each bit signifies a signal status where 1 means the signal is active and 0 means the signal is inactive. The value returned is a snapshot taken when the command actually is sent to the driver software and wherever possible actually goes out to the driver or receiver control chips to get the value. Currently defined bit values are as follows*: 128 : Data Terminal Ready 0x0080 RS-232 pin 20 64 : Data Set Ready 0x0040 RS-232 pin 6 32 : Clear to Send 0x0020 RS-232 pin 5 16 : Clear to Send Ext. 0x0010 RS-232 pin 11** 8 : Data Carrier Detect 0x0008 RS-232 pin 8 4 : Busy Out 0x0004 RS-232 pin 25 2 : Request to send 0x0002 RS-232 pin 4 1 : Ring Indicator 0x0001 RS-232 pin 22 Note*: Bit values higher than 128 are reserved for future use. Note**: Clear to Send External is extended (non- standard) pin and reserved for future use by Sync Research." ::= { linePhysicalEntry 3 } lineQualityFrameCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of frames received. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts exceeds 5. When this value reaches 255, it then rolls back to 0. Applicable to SDLC only." ::= { linePhysicalEntry 4} lineQualityCRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of frames with CRC errors. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts exceeds 5. Applicable to SDLC only." ::= { linePhysicalEntry 5 } lineQualityAborts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of aborts received. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts exceeds 5. Applicable to SDLC only." ::= { linePhysicalEntry 6 } lineInterfaceType OBJECT-TYPE SYNTAX INTEGER { line-RS232(1), line-V35(2), line-RS530(3), line-universal(4), dsu-csu(5), isdn(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Report hardware Interface type of the line. For older systems, this interface is fixed per port. For universal ports, the Interface type if set via the cable." ::= { linePhysicalEntry 7 } lineCableType OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), indeterminate-cable(2), no-cable-attached(3), rs232-DTE-cable(4), rs232-DCE-cable(5), v35-DTE-cable(6), v35-DCE-cable(7), x21-DTE-cable(8), x21-DCE-cable(9), rs530-DTE-cable(10), rs530-DCE-cable(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Returns not-applicable if the h/w does not support universal port configuration. Identifies the cable type connected to the port." ::= { linePhysicalEntry 8 } lineSwitchedConnection OBJECT-TYPE SYNTAX INTEGER { not-applicable(1), dedicated(2), switched(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies whether the line is connected over a switched backup facility or a dedicated facility to a frame relay network. This parameter is applicable to frame relay port only. For any other ports it returns not-applicable. If the object frameRelaySwitchedBackup is set to none it returns not-applicable. Otherwise returns appropriate value." ::= { linePhysicalEntry 9 } -- -- The ISDN Config Control Group -- -- This is a separate group for the ISDN internal device. -- -- This is the configuration for this device isdndeviceConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdndeviceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of device entries." ::= { isdnControlGroup 1 } isdndeviceConfigEntry OBJECT-TYPE SYNTAX IsdndeviceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given device. The entry is indexed by the port number, CU index, and device." INDEX { isdnLineIndex } ::= { isdndeviceConfigTable 1 } IsdndeviceConfigEntry ::= SEQUENCE { isdnLineIndex INTEGER, serviceType INTEGER, isdnSpeed INTEGER, connectionTimeOut INTEGER, nosConnectAttempts INTEGER, farEndNumberType INTEGER, farEndNumberPlan INTEGER, farEndNumber INTEGER, localNumberType INTEGER, localNumberPlan INTEGER, localNumber INTEGER, spid OCTET STRING } isdnLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the ISDN line is configured (line level)." ::= { isdndeviceConfigEntry 1 } serviceType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Defines the service type of the ISDN WAN port." ::= { isdndeviceConfigEntry 2 } isdnSpeed OBJECT-TYPE SYNTAX INTEGER { speed56000(560), speed64000(640) } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in 100 bits per second. The default value is 56000 bits per second." ::= { isdndeviceConfigEntry 3 } connectionTimeOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Defines the time to wait after sensing disruption before declaring failure. The range is 0 to 255 seconds. The default value is 12 seconds." ::= { isdndeviceConfigEntry 4 } nosConnectAttempts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Defines the number or re-dial attempts before fail to connect. The range is 0 to 255. The default value is 1." ::= { isdndeviceConfigEntry 5 } farEndNumberType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "One byte field that defines the called number type." ::= { isdndeviceConfigEntry 6 } farEndNumberPlan OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "One byte field that defines the called number Plan." ::= { isdndeviceConfigEntry 7 } farEndNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "One byte field that defines the called number." ::= { isdndeviceConfigEntry 8 } localNumberType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "One byte field that defines the local number type." ::= { isdndeviceConfigEntry 9 } localNumberPlan OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "One byte field that defines the local number Plan." ::= { isdndeviceConfigEntry 10 } localNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "One byte field that defines the local number." ::= { isdndeviceConfigEntry 11 } spid OBJECT-TYPE SYNTAX OCTET STRING (SIZE(20)) ACCESS read-only STATUS mandatory DESCRIPTION "SPID is a zero-terminated ASCII string with a minium length of 0 and a maximum length of 20. " ::= { isdndeviceConfigEntry 12 } -- -- The ISDN Statitics Group -- isdndeviceStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdndeviceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of device entries." ::= { isdnControlGroup 2 } isdndeviceStatsEntry OBJECT-TYPE SYNTAX IsdndeviceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given device. The entry is indexed by the port number, CU index, and device." INDEX { isdnIndex } ::= { isdndeviceStatsTable 1 } IsdndeviceStatsEntry ::= SEQUENCE { isdnIndex INTEGER, channelID INTEGER, kbytesTransmitted Counter, kbytesReceived Counter, packetsTransmitted Counter, packetsReceived Counter, isdnloopbackbytesTransmitted Counter, isdnloopbackbytesReceived Counter, isdnCRCErrors Counter } isdnIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the ISDN line is configured (line level)." ::= { isdndeviceStatsEntry 1 } channelID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the ISDN line is configured (line level)." ::= { isdndeviceStatsEntry 2 } kbytesTransmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of bytes transmited." ::= { isdndeviceStatsEntry 3 } kbytesReceived OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of bytes received." ::= { isdndeviceStatsEntry 4 } packetsTransmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of packets transmited." ::= { isdndeviceStatsEntry 5 } packetsReceived OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of packets received." ::= { isdndeviceStatsEntry 6 } isdnloopbackbytesTransmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of bytes transmited." ::= { isdndeviceStatsEntry 7 } isdnloopbackbytesReceived OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of bytes received." ::= { isdndeviceStatsEntry 8 } isdnCRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of frames with CRC errors." ::= { isdndeviceStatsEntry 9 } -- -- The DsuCSU Control Group -- -- This is a separate group for the DSU/CSU internal device. -- -- This is the configuration for this device -- dsucsudeviceConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF DsucsudeviceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of device entries." ::= { dsucsuControlGroup 1 } dsucsudeviceConfigEntry OBJECT-TYPE SYNTAX DsucsudeviceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given device. The entry is indexed by the port number, CU index, and device." INDEX { dsucsuLineNumber } ::= { dsucsudeviceConfigTable 1 } DsucsudeviceConfigEntry ::= SEQUENCE { dsucsuLineNumber INTEGER, dsucsuType INTEGER, dsucsuClocking INTEGER, dsucsuSpeed INTEGER } dsucsuLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the DsuCsu line is configured (line level)." ::= { dsucsudeviceConfigEntry 1 } dsucsuType OBJECT-TYPE SYNTAX INTEGER { dsu-csu-dds(1), dsu-csu-async-dial(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines the service type of the DSU/CSU port." ::= { dsucsudeviceConfigEntry 2 } dsucsuClocking OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Clocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. The default value for this field is 'external'." ::= { dsucsudeviceConfigEntry 3 } dsucsuSpeed OBJECT-TYPE SYNTAX INTEGER { speed56000(560), speed64000(640) } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in 100 bits per second. The default value is 56000 bits per second." ::= { dsucsudeviceConfigEntry 4 } -- -- The DsuCSU Stats Group -- -- dsucsudeviceStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF DsucsudeviceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of device entries." ::= { dsucsuControlGroup 2 } dsucsudeviceStatsEntry OBJECT-TYPE SYNTAX DsucsudeviceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given device. The entry is indexed by the port number, CU index, and device." INDEX { dsucsuLine } ::= { dsucsudeviceStatsTable 1 } DsucsudeviceStatsEntry ::= SEQUENCE { dsucsuLine INTEGER, dsucsuloopbackbytesTransmitted Counter, dsucsuloopbackbytesReceived Counter } dsucsuLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the DsuCsu line is configured (line level)." ::= { dsucsudeviceStatsEntry 1 } dsucsuloopbackbytesTransmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of bytes transmited." ::= { dsucsudeviceStatsEntry 2 } dsucsuloopbackbytesReceived OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the number of bytes received." ::= { dsucsudeviceStatsEntry 3 } -- -- The SDLC Port Level Configuration Group -- -- -- The SDLC Configuration Table: -- sdlcConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SdlcConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of SDLC information." ::= { lineSDLCGroup 1 } sdlcConfigEntry OBJECT-TYPE SYNTAX SdlcConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular SDLC port." INDEX { sdlcConfigPortIndex } ::= { sdlcConfigTable 1 } SdlcConfigEntry ::= SEQUENCE { sdlcConfigPortIndex INTEGER, sdlcConfigType INTEGER, sdlcInitState INTEGER, sdlcCarrier INTEGER, sdlcClocking INTEGER, sdlcSpeed INTEGER, sdlcPause INTEGER, sdlcNRZI INTEGER, sdlcT1Timer INTEGER, sdlcSlowPollTimer INTEGER, sdlcMaxRetries INTEGER, sdlcNAUName DisplayString, sdlcMultiFlagInsertion INTEGER, sdlcCTS INTEGER, sdlcDCD INTEGER, sdlcDSR INTEGER, sdlcDTR INTEGER, sdlcRTS INTEGER, sdlcReturnClock INTEGER } sdlcConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port. Current supported SDLC numbers are 1-4." ::= { sdlcConfigEntry 1 } sdlcConfigType OBJECT-TYPE SYNTAX INTEGER { hsdlc-type(11), tsdlc-type(12) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU. Note that all ports must currently be defined as the same time for a given unit (i.e. no mixing of HSDLC and TSDLC ports is allowed)." ::= { sdlcConfigEntry 2 } sdlcInitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the SDLC port. If configured for 'in-service', then the SDLC port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the SDLC port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'." ::= { sdlcConfigEntry 3 } sdlcCarrier OBJECT-TYPE SYNTAX INTEGER { constant(1), switched(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This field indicates whether Carrier (a.k.a. CD or DCD, RS-232 pin 8) is constant or switched for DCE devices (internally clocked), or Request To Send (a.k.a. RTS, RS-232 pin 4) is constant or switched. This parameter also affects SDLC flag generation. If configured for constant then the line will transmit flags in an idle (no data being sent) state. If configured for switched then the line will transmit all one bits (mark state). The default value for this parameter is 'constant'." ::= { sdlcConfigEntry 4 } sdlcClocking OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2), x21-external(3), x21-internal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Clocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. X21 External and Internal are used (with the proper external adapter) to support X.21 Leased Line operation for RS-422/RS-530 (25 pin balanced) interfaces. X21 operation is not supported for boards that operate RS-232 or V.35. The default value for this field is 'external'." ::= { sdlcConfigEntry 5 } sdlcSpeed OBJECT-TYPE SYNTAX INTEGER { speed1200(12), speed2000(20), speed2400(24), speed3600(36), speed4800(48), speed7200(72), speed9600(96), speed14400(144), speed19200(192), speed28800(288), speed48000(480), speed56000(560), speed64000(640), speed128000(1280) } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in 100 bits per second. The default value is 9600 bits per second. Speeds higher than 19200 are not supported on RS-232 ports units (must be V.35 or RS-422)." ::= { sdlcConfigEntry 6 } sdlcPause OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the amount of time between polls in 1/100 second (10 millisecond) intervals. If set to zero then the port will poll the PUs as fast as possible. The minimum value for this parameter is 5 and the timer has a resolution of 25 milliseconds. The default value is 20 (.20 seconds). This field is not applicable to Host port. It returns a dummy value." ::= { sdlcConfigEntry 7 } sdlcNRZI OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates whether the port is configured for NRZI (yes) or NRZ (no) bit encoding. The default value is 'No' (NRZ encoding selected)." ::= { sdlcConfigEntry 8 } sdlcT1Timer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The SDLC T1 timer value in 20ths of a second. The default value is 20 (1 second). This field is not applicable to Host ports. It returns a dummy value." ::= { sdlcConfigEntry 9 } sdlcSlowPollTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slow poll timer value in 20ths of a second. The slow poll timer is the amount of time to wait to contact (send SNRM) failed PUs. The default value for this field is 600 (30 seconds). This field is not applicable to Host ports. It returns a dummy value." ::= { sdlcConfigEntry 10 } sdlcMaxRetries OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of retries (N2 value) before failing a PU. The default value for this field is 3. This field is not applicable to Host ports. It returns a dummy value." ::= { sdlcConfigEntry 11 } sdlcNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { sdlcConfigEntry 12 } sdlcMultiFlagInsertion OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates whether the port is configured to send multiple interframe flags. The default value is 'No' (single flags)." ::= { sdlcConfigEntry 13 } sdlcCTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { sdlcConfigEntry 14 } sdlcDCD OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { sdlcConfigEntry 15 } sdlcDSR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DSR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { sdlcConfigEntry 16 } sdlcDTR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and DTR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { sdlcConfigEntry 17 } sdlcRTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and RTS is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { sdlcConfigEntry 18 } sdlcReturnClock OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), default(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored. The range is yes and no. The default value is 'yes'." ::= { sdlcConfigEntry 19 } -- -- The SDLC Port Statistics Table: -- sdlcStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SdlcStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of SDLC information." ::= { lineSDLCGroup 2 } sdlcStatsEntry OBJECT-TYPE SYNTAX SdlcStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular SDLC port." INDEX { sdlcStatsPortIndex } ::= { sdlcStatsTable 1 } SdlcStatsEntry ::= SEQUENCE { sdlcStatsPortIndex INTEGER, sdlcPortType INTEGER, sdlcInOctets Counter, sdlcOutOctets Counter, sdlcInFrames Counter, sdlcOutFrames Counter, sdlcOverruns Counter, sdlcCRCErrors Counter, sdlcRecvAborts Counter, sdlcpollrsptimeouts Counter, sdlciframetrans Counter } sdlcStatsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this SDLC port. Current supported numbers on are 1-4." ::= { sdlcStatsEntry 1 } sdlcPortType OBJECT-TYPE SYNTAX INTEGER { hsdlc-type(11), tsdlc-type(12) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU." ::= { sdlcStatsEntry 2 } sdlcInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received." ::= { sdlcStatsEntry 3 } sdlcOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes sent." ::= { sdlcStatsEntry 4 } sdlcInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of I-frames received." ::= { sdlcStatsEntry 5 } sdlcOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of I-frames sent." ::= { sdlcStatsEntry 6 } sdlcOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of overruns." ::= { sdlcStatsEntry 7 } sdlcCRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of CRC errors." ::= { sdlcStatsEntry 8 } sdlcRecvAborts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of aborts received." ::= { sdlcStatsEntry 9 } sdlcpollrsptimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of poll response timeouts." ::= { sdlcStatsEntry 10 } sdlciframetrans OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of i-frame re-transmissions." ::= { sdlcStatsEntry 11 } -- -- The Bisync Port Level Group -- -- -- The Bisync Configuration Table: -- bisyncConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF BisyncConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Bisync port information." ::= { lineBisyncGroup 1 } bisyncConfigEntry OBJECT-TYPE SYNTAX BisyncConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Bisync port." INDEX { bisyncConfigPortIndex } ::= { bisyncConfigTable 1 } BisyncConfigEntry ::= SEQUENCE { bisyncConfigPortIndex INTEGER, bisyncConfigType INTEGER, bisyncNAUName DisplayString, bisyncInitState INTEGER, bisyncCarrier INTEGER, bisyncClocking INTEGER, bisyncSpeed INTEGER, bisyncPause INTEGER, bisyncReplyTimer INTEGER, bisyncRetries INTEGER, bisyncSlowpollTimer INTEGER, bisyncSessTerm INTEGER, bisyncIBS INTEGER, bisyncCTS INTEGER, bisyncDCD INTEGER, bisyncDSR INTEGER, bisyncDTR INTEGER, bisyncRTS INTEGER, bisyncReturnClock INTEGER } bisyncConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port. Current supported Bisync numbers are 1-4." ::= { bisyncConfigEntry 1 } bisyncConfigType OBJECT-TYPE SYNTAX INTEGER { hbsc-type(1), tbsc-type(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TBSC (Terminal Bisync) ports emulate a Host and polls the downstream controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (CUs) and respond to polls from the Host." ::= { bisyncConfigEntry 2 } bisyncNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { bisyncConfigEntry 3 } bisyncInitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the Bisync port. If configured for 'in-service', then the Bisync port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', then the Bisync port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'." ::= { bisyncConfigEntry 4 } bisyncCarrier OBJECT-TYPE SYNTAX INTEGER { constant(1), switched(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This field indicates whether Carrier (a.k.a. CD or DCD, RS-232 pin 8) is constant or switched for DCE devices (internally clocked), or Request To Send (a.k.a. RTS, RS-232 pin 4) is constant or switched. The default value for this parameter is 'constant'." ::= { bisyncConfigEntry 5 } bisyncClocking OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2), x21-external(3), x21-internal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Clocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. X21 External and Internal are used (with the proper external adapter) to support X.21 Leased Line operation for RS-422/RS-530 (25 pin balanced) interfaces. X21 operation is not supported for boards that operate RS-232 or V.35. The default value for this field is 'external'." ::= { bisyncConfigEntry 6 } bisyncSpeed OBJECT-TYPE SYNTAX INTEGER { speed1200(12), speed2000(20), speed2400(24), speed3600(36), speed4800(48), speed7200(72), speed9600(96), speed14400(144), speed19200(192), speed28800(288), speed48000(480), speed56000(560), speed64000(640) } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 64000 are not supported." ::= { bisyncConfigEntry 7 } bisyncPause OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the amount of time between polls in 1/100 second (10 millisecond) intervals. If set to zero then the port will poll the CUs as fast as possible. The minimum value for this parameter is 5 and the timer has a resolution of 25 milliseconds. The default value is 20 (.20 seconds). This field is not applicable to a Host port. It returns a dummy value." ::= { bisyncConfigEntry 8 } bisyncReplyTimer OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "The time to wait for a response in seconds. The default value for this field is 3 seconds." ::= { bisyncConfigEntry 9 } bisyncRetries OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of retries (N2 value) before failing a CU. The default value for this field is 5." ::= { bisyncConfigEntry 10 } bisyncSlowpollTimer OBJECT-TYPE SYNTAX INTEGER (1..99) ACCESS read-only STATUS mandatory DESCRIPTION "The time to wait in seconds before attempting a slowpoll. The default value for this field is 30 seconds." ::= { bisyncConfigEntry 11 } bisyncSessTerm OBJECT-TYPE SYNTAX INTEGER { none (1), interventionReq (2), unformattedLogoff (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of session termination used. Only applies to Host BSC ports." ::= { bisyncConfigEntry 12 } bisyncIBS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Some of non IBM 3270 BSC controllers can not handle ESC character but IBM 3270 BSC implementation requires ESC character. A new configuration parameter for Terminal BSC line as described below The default value is Yes." ::= { bisyncConfigEntry 13 } bisyncCTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { bisyncConfigEntry 14 } bisyncDCD OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { bisyncConfigEntry 15 } bisyncDSR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DSR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { bisyncConfigEntry 16 } bisyncDTR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and DTR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { bisyncConfigEntry 17 } bisyncRTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and RTS is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { bisyncConfigEntry 18 } bisyncReturnClock OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), default(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored. The range is yes and no. The default value is 'yes'." ::= { bisyncConfigEntry 19 } -- -- The Bisync Port Statistics Table: -- bisyncStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF BisyncStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Bisync information." ::= { lineBisyncGroup 2 } bisyncStatsEntry OBJECT-TYPE SYNTAX BisyncStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Bisync port." INDEX { bisyncStatsPortIndex } ::= { bisyncStatsTable 1 } BisyncStatsEntry ::= SEQUENCE { bisyncStatsPortIndex INTEGER, bisyncPortType INTEGER, bisyncInOctets Counter, bisyncOutOctets Counter, bisyncOverruns Counter, bisyncCRCErrors Counter, bisyncRcvTimeout Counter, bisyncXmtTimeout Counter } bisyncStatsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this Bisync port. Current supported numbers are 1-4." ::= { bisyncStatsEntry 1 } bisyncPortType OBJECT-TYPE SYNTAX INTEGER { hbsc-type(1), tbsc-type(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. TBSC (Terminal Bisync) ports emulate a Host and poll the downstream controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU." ::= { bisyncStatsEntry 2 } bisyncInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received." ::= { bisyncStatsEntry 3 } bisyncOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes sent." ::= { bisyncStatsEntry 4 } bisyncOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receiver overruns." ::= { bisyncStatsEntry 5 } bisyncCRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receive frame CRC errors." ::= { bisyncStatsEntry 6 } bisyncRcvTimeout OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receive timeout." ::= { bisyncStatsEntry 7 } bisyncXmtTimeout OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit timeout." ::= { bisyncStatsEntry 8 } -- -- The Frame Relay Port Level Group -- -- -- The Frame Relay Configuration Table: -- frameRelayConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF FrameRelayConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Sync product Frame Relay information." ::= { lineFrameRelayGroup 1 } frameRelayConfigEntry OBJECT-TYPE SYNTAX FrameRelayConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Sync product Frame Relay port." INDEX { frameRelayConfigPortIndex } ::= { frameRelayConfigTable 1 } FrameRelayConfigEntry ::= SEQUENCE { frameRelayConfigPortIndex INTEGER, frameRelayPortType INTEGER, frameRelayInitState INTEGER, frameRelayClocking INTEGER, frameRelaySpeed INTEGER, frameRelayLocalManagementProtocol INTEGER, frameRelayLinkPollingTimer INTEGER, frameRelayFullStatusPollingCount INTEGER, frameRelayT1Timer INTEGER, frameRelayT2Timer INTEGER, frameRelayTiTimer INTEGER, frameRelayRxWindowSize INTEGER, frameRelayTxWindowSize INTEGER, frameRelayMaxRetries INTEGER, frameRelayNAUName DisplayString, frameRelayVirtualMACAddress PhysAddress, frameRelayVirtualRingNumber INTEGER, frameRelayVirtualBridgeNumber INTEGER, frameRelayIPAddress IpAddress, frameRelayNetworkMask IpAddress, frameRelayDefaultGatewayAddress IpAddress, frameRelaySessSwitchThreshold INTEGER, frameRelaySwitchedBackup INTEGER, frameRelaySwitchedLineWaitTimer INTEGER, frameRelayDedLineWaitTimer INTEGER, frameRelayCommittedBurst INTEGER, frameRelayExcessBurst INTEGER, frameRelayBridgingProtocol INTEGER, frameRelayProxyARP INTEGER, frameRelaySecondDefaultGatewayAddress IpAddress, frameRelayAlternateIPAddress IpAddress, frameRelayAlternateNetmask IpAddress, frameRelayLLC2FrameFormat INTEGER, frameRelayMultiflagSeparation INTEGER, frameRelayRestrictTerminateSessUsage INTEGER, frameRelayRIPUpdtTimer INTEGER, frameRelayRIPAge INTEGER, frameRelaySAPUpdtTimer INTEGER, frameRelaySAPAge INTEGER, frameRelayRSM INTEGER, frameRelayARP INTEGER, frameRelayCTS INTEGER, frameRelayDCD INTEGER, frameRelayDSR INTEGER, frameRelayDTR INTEGER, frameRelayRTS INTEGER, frameRelayReturnClock INTEGER } frameRelayConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port." ::= { frameRelayConfigEntry 1 } frameRelayPortType OBJECT-TYPE SYNTAX INTEGER { frame-relay-type(19), frame-relay-dialbackup-type(20) } ACCESS read-only STATUS mandatory DESCRIPTION "The Frame Relay port type." ::= { frameRelayConfigEntry 2 } frameRelayInitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the Frame Relay port. If configured for 'in-service', then the Frame Relay port will be brougt up automatically when the unit is powered up. If configured for 'out-of-service', then the Frame Relay port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'." ::= { frameRelayConfigEntry 3 } frameRelayClocking OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2), x21-external(3), x21-internal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Clocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. X21 External and Internal are used (with the proper external adapter) to support X.21 Leased Line operation for RS-422/RS-530 (25 pin balanced) interfaces. X21 operation is not supported for boards that operate RS-232 or V.35. The default value for this field is 'external'." ::= { frameRelayConfigEntry 4 } frameRelaySpeed OBJECT-TYPE SYNTAX INTEGER { speed1200(12), speed2000(20), speed2400(24), speed3600(36), speed4800(48), speed7200(72), speed9600(96), speed14400(144), speed19200(192), speed28800(288), speed48000(480), speed56000(560), speed64000(640), speed128000(1280), speed256000(2560), speed512000(5120), speed102400(10240), speed154400(15440), speed204800(20480) } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 19200 are not supported on RS-232 port Sync products (must be V.35 or RS-422)." ::= { frameRelayConfigEntry 5 } frameRelayLocalManagementProtocol OBJECT-TYPE SYNTAX INTEGER { annexD(1), lmi(2), annexA(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The ports management protocol type. Annex D = ANSI T1.617 Annex D LMI = Frame Relay Manufacturers LMI The default value is Annex D." ::= { frameRelayConfigEntry 6 } frameRelayLinkPollingTimer OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-only STATUS mandatory DESCRIPTION "Measured in seconds, intervals of 5 T391 - Annex D nT1 - LMI The default value for this field is 5 seconds." ::= { frameRelayConfigEntry 7 } frameRelayFullStatusPollingCount OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of polls that a full status poll is issued. N391 - Annex D nT1 - LMI The default value for this field is 6." ::= { frameRelayConfigEntry 8 } frameRelayT1Timer OBJECT-TYPE SYNTAX INTEGER (1..25) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC T1 timer value in seconds. T1 should be greater than T2 and less than Ti. Currently supported values are 1 to 25 seconds. The default value for this field is 3 seconds." ::= { frameRelayConfigEntry 9 } frameRelayT2Timer OBJECT-TYPE SYNTAX INTEGER (0..50) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC T2 timer value in tenths of seconds. If configured for 0 then the T2 timer is disabled and an RR frame will be sent for every I frame received. Current supported values are 0 and 2-50. T2 should be less than T1. The default value for this field is 0 (disabled)." ::= { frameRelayConfigEntry 10 } frameRelayTiTimer OBJECT-TYPE SYNTAX INTEGER (2..50) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC Ti (inactivity) timer value in seconds. Ti should be greater than T1. Currently supported values are 2 to 50 seconds. The default value for this field is 30 seconds." ::= { frameRelayConfigEntry 11 } frameRelayRxWindowSize OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC receive window (N3) size. Note that this is not the same receive window as defined in IEEE 802.2 LLC. This is N3 which is the number of I frames received before an RR frame is sent (defined as N3 in IEEE 802.2 LLC). Current allowable values are 1-7. The default value for this field is 7." ::= { frameRelayConfigEntry 12 } frameRelayTxWindowSize OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "The defalut LLC transmit window size. Current allowable values are 1-7. The default value for this field is 7." ::= { frameRelayConfigEntry 13 } frameRelayMaxRetries OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS mandatory DESCRIPTION "The default LLC maximum number of retries (N2 value). The default value for this field is 15." ::= { frameRelayConfigEntry 14 } frameRelayNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { frameRelayConfigEntry 15 } frameRelayVirtualMACAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The F/R WAN is treated as a token ring. This address is used for communication with other bridges in the network." ::= { frameRelayConfigEntry 16 } frameRelayVirtualRingNumber OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The F/R WAN is treated as a token ring. This is the ring number for the F/R network to which the port is attached. It must be a unique ring number in the network. This value is configured in hex from 0 to FFF. The default value for this field is 1." ::= { frameRelayConfigEntry 17 } frameRelayVirtualBridgeNumber OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "The F/R WAN is treated as a token ring. This variable only has significance if more than 1 F/R port is configured. The default value for this field is 1." ::= { frameRelayConfigEntry 18 } frameRelayIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the IP Address of this interface." ::= { frameRelayConfigEntry 19 } frameRelayNetworkMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the network mask to be used on this interface." ::= { frameRelayConfigEntry 20 } frameRelayDefaultGatewayAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Default gateway address to be used when sending responses on this interface." ::= { frameRelayConfigEntry 21 } frameRelaySessSwitchThreshold OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "Describes the session switch threshold for a session to switch between eVR and pVR. The value represents the LLC time-out occurrence for any session on this port. If one session has the configured number of time-outs, all sessions using that PVC are switched between eVR and pVR. Sessions that do not have a pVR are terminated." ::= { frameRelayConfigEntry 22 } frameRelaySwitchedBackup OBJECT-TYPE SYNTAX INTEGER { none (1), racal-dtr-initiated(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines the switched backup protocol used for dial backup. The range of this parameter is NONE or RACAL DTR-initiated. The default value is NONE." ::= { frameRelayConfigEntry 23 } frameRelaySwitchedLineWaitTimer OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the maximum amount of time the FrameNode waits for the DAP to establish a dial connection before switching back to the dedicated line. This parameter is required because the DAP does not notify the FrameNode as to whether the dial backup connection was successful or not. This parameter, in concert with a high level protocol, helps determine whether or not the connection was successful. This parameter is expressed in minutes. The range of this parameter is from 1 minute to 60 minutes. The default value is 5 minutes." ::= { frameRelayConfigEntry 24 } frameRelayDedLineWaitTimer OBJECT-TYPE SYNTAX INTEGER (10..120) ACCESS read-only STATUS mandatory DESCRIPTION "The FCC regulation for Autodialers requires that an Autodialer waits between successive dial operations. This parameter satisfies the FCC requirements. It controls the maximum time the FrameNode waits before initiating another dial restoral operation if the previous operation fails. The timer starts when DTR is lowered. DTR is raised again upon expiration of the timer. This parameter is expressed in minutes. Its range is from 10 minutes to 120 minutes with a one minute resolution. The default value it 10 minutes." ::= { frameRelayConfigEntry 25 } frameRelayCommittedBurst OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies the maximum number of bits, during time interval Tc, the network agrees to accept under normal conditions. This parameter must match the configured value for the network. The value of this parameter can not be greater that the line speed. The range of the parameter is 1Kbits to 2048Kbits. The default value equals the line speed. However, this value depends on the Measurement Period Tc and the line speed. The value is expressed in Kbits." ::= { frameRelayConfigEntry 26 } frameRelayExcessBurst OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum number of uncommitted bits, during time interval Tc, the network accepts above the committed burst size Bc. When the Excess burst Governor is configured to YES, the FrameNode tries to limit the throughput to the Bc + Be bits in the Time Period Tc. The default value of this parameter is 0. The range is from 0K to 2048K. However, the value depends on the Measurement Period Tc and the speed of the line. The value is expressed in Kbits." ::= { frameRelayConfigEntry 27 } frameRelayBridgingProtocol OBJECT-TYPE SYNTAX INTEGER { srb(1), tbr(2), both(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies the bridging protocol to be used over Frame Relay link. This parameter has no effect if bridging is not turned on. The range of this parameter is SRB (source route bridging), TBR(transparent bridging) or BOTH. The value is BOTH." ::= { frameRelayConfigEntry 28 } frameRelayProxyARP OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines whether PROXY ARP is enabled for F/R attached devices or not. Range of this parameter is ENABLED or DISABLED. The value is 'DISABLED'." ::= { frameRelayConfigEntry 29 } frameRelaySecondDefaultGatewayAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Second Default gateway address to be used when sending responses on this interface." ::= { frameRelayConfigEntry 30 } frameRelayAlternateIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the Alternate IP Address for single port dial up connection." ::= { frameRelayConfigEntry 31 } frameRelayAlternateNetmask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the Alternate network mask for IP for single port dial up connecton." ::= { frameRelayConfigEntry 32 } frameRelayLLC2FrameFormat OBJECT-TYPE SYNTAX INTEGER { tokenRing(1), ethernetVersiontwo(2), iEEEeightotwothree(3), all(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies the LLC2 frame format to be used over Frame Relay link. The range of this parameter is Token Ring, Ethernet Version 2, IEEE 802.3 or ALL. The value is ALL." ::= { frameRelayConfigEntry 33 } frameRelayMultiflagSeparation OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies whether the unit will insert more than one flag between frames. The range of this parameter is yes and no. The value is 'no'." ::= { frameRelayConfigEntry 34 } frameRelayRestrictTerminateSessUsage OBJECT-TYPE SYNTAX INTEGER { no(1), spanningTree(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies whether terminated sessions are to follow spanning tree states or not over Frame Relay Link. The range of this parameter is No and SpanningTree. The value is 'no'." ::= { frameRelayConfigEntry 35 } frameRelayRIPUpdtTimer OBJECT-TYPE SYNTAX INTEGER (10..180) ACCESS read-only STATUS mandatory DESCRIPTION "Defines frequency at which the RIP packets are sent over this interface. The range of this parameter is from 10 seconds to 180 seconds. A value of 0 implies no RIP is sent over this interface. Default value is 60 seconds" ::= { frameRelayConfigEntry 36 } frameRelayRIPAge OBJECT-TYPE SYNTAX INTEGER (40..540) ACCESS read-only STATUS mandatory DESCRIPTION "Defines frequency at which the learned RIP entries are removed if not corresponding RIP update is received. The range of this parameter is from 40 seconds to 540 seconds. Default value is 180 seconds" ::= { frameRelayConfigEntry 37 } frameRelaySAPUpdtTimer OBJECT-TYPE SYNTAX INTEGER (0..180) ACCESS read-only STATUS mandatory DESCRIPTION "Defines frequency at which the SAP packets are sent over this interface. The range of this parameter is from 10 seconds to 180 seconds. A value of 0 implies that no SAP broadcasts are sent over this interface. Default value is 60 seconds" ::= { frameRelayConfigEntry 38 } frameRelaySAPAge OBJECT-TYPE SYNTAX INTEGER (40..720) ACCESS read-only STATUS mandatory DESCRIPTION "Defines frequency at which the learned SAP entries are removed if not corresponding SAP update is received. The range of this parameter is from 40 seconds to 720 seconds. Default value is 180 seconds" ::= { frameRelayConfigEntry 39 } frameRelayRSM OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Routing Summary Information parameter indicates whether the routing summary information should be generated in the RIP on that interface. If RSM is set to NO, RIP will broadcast subnet information as it is defined in the routing table. Default value is 'NO'" ::= { frameRelayConfigEntry 40 } frameRelayARP OBJECT-TYPE SYNTAX INTEGER { auto(1), inverseArp(2), routedArp(3), tokenRing(4), ethernetVersiontwo(5), iEEEeightotwothree(6), none(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The ARP parameter indicates what format of ARP should be generated. Default value is 'Auto'" ::= { frameRelayConfigEntry 41 } frameRelayCTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { frameRelayConfigEntry 42 } frameRelayDCD OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { frameRelayConfigEntry 43 } frameRelayDSR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DSR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { frameRelayConfigEntry 44 } frameRelayDTR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and DTR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { frameRelayConfigEntry 45 } frameRelayRTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and RTS is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { frameRelayConfigEntry 46 } frameRelayReturnClock OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), default(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored. The range is yes and no. The default value is 'yes'." ::= { frameRelayConfigEntry 47 } -- -- The Frame Relay Port Statistics Table: -- frameRelayStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF FrameRelayStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Frame Relay information." ::= { lineFrameRelayGroup 2 } frameRelayStatsEntry OBJECT-TYPE SYNTAX FrameRelayStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Frame Relay port." INDEX { frameRelayStatsPortIndex } ::= { frameRelayStatsTable 1 } FrameRelayStatsEntry ::= SEQUENCE { frameRelayStatsPortIndex INTEGER, frameRelayInOctets Counter, frameRelayOutOctets Counter, frameRelaySampleDuration INTEGER, frameRelayOverruns Counter, frameRelayCRCErrors Counter, frameRelayRecvAborts Counter, frameRelayTxDe Counter, frameRelayRxDe Counter, frameRelaySwitchedAttempts Counter, frameRelaySwitchedAttemptsSuccessful Counter } frameRelayStatsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this Frame Relay port." ::= { frameRelayStatsEntry 1 } frameRelayInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received inclusive of all valid bytes in the frame relay frame except for the CRC field (frame relay header included)." ::= { frameRelayStatsEntry 2 } frameRelayOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes transmitted inclusive of all bytes in the frame relay frame except for the CRC field (frame relay header included)." ::= { frameRelayStatsEntry 3 } frameRelaySampleDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The sample duration in seconds for Frame Relay Statistics for this port." ::= { frameRelayStatsEntry 4 } frameRelayOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receiver overruns." ::= { frameRelayStatsEntry 5 } frameRelayCRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received CRC errors." ::= { frameRelayStatsEntry 6 } frameRelayRecvAborts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received frame aborts received." ::= { frameRelayStatsEntry 7 } frameRelayTxDe OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frames sent with the DE bit." ::= { frameRelayStatsEntry 8 } frameRelayRxDe OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frames received with the DE bit." ::= { frameRelayStatsEntry 9 } frameRelaySwitchedAttempts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of times a switched backup is attempted." ::= { frameRelayStatsEntry 10 } frameRelaySwitchedAttemptsSuccessful OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of times switched backup attempts were successful." ::= { frameRelayStatsEntry 11 } -- -- Sync Circuit Table Extension -- -- frExtCircuitTable OBJECT-TYPE SYNTAX SEQUENCE OF FrExtCircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information about specific Data Link Connection Identifiers and corresponding virtual circuits." ::= { nodeFrCirGroup 1 } frExtCircuitEntry OBJECT-TYPE SYNTAX FrExtCircuitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The information regarding a single Data Link Connection Identifier." INDEX { frExtCircuitIfIndex, frExtCircuitDlci } ::= { frExtCircuitTable 1 } FrExtCircuitEntry ::= SEQUENCE { frExtCircuitIfIndex INTEGER, frExtCircuitDlci INTEGER, frExtCircuitStatusIgnored INTEGER, frExtCircuitStatusAcknowledged INTEGER, frExtCircuitPartnerId DisplayString, frExtCircuitTxDe Counter, frExtCircuitRxDe Counter, frExtCircuitMinBits Gauge, frExtCircuitMaxBits Gauge, frExtCircuitQOctets Counter } frExtCircuitIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex Value of the ifEntry this virtual circuit is layered onto." ::= { frExtCircuitEntry 1 } frExtCircuitDlci OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Data Link Connection Identifier for this virtual circuit." REFERENCE "Draft American National Standard T1.618-1991, Section 3.3.6" ::= { frExtCircuitEntry 2 } frExtCircuitStatusIgnored OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. The status of this circuit is not put into consideration when consolidating status of the unit if this field is set to yes." ::= { frExtCircuitEntry 3 } frExtCircuitStatusAcknowledged OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. When this field is set to acknowledge, unit will re-consolidate its status without putting the status of this circuit into consideration. Subseqent status change of the circuit will cause the unit to include it in computing the status of the unit. Setting this value to no has no effect." ::= { frExtCircuitEntry 4 } frExtCircuitPartnerId OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the unit id of the FrameNode at the other end of the Frame relay PVC. It consists of a 1 to 8 octets right justified case-sensitive ASCII field which uniquely identifies the unit. If the unit at the other end of the Frame Relay PVC is not a Sync Research FrameNode, or and OEM equipment NON-FN is returned for this object." ::= { frExtCircuitEntry 5 } frExtCircuitTxDe OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frames sent with DE bit for this PVC." ::= { frExtCircuitEntry 6 } frExtCircuitRxDe OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frames received with the DE bit for this PVC." ::= { frExtCircuitEntry 7 } frExtCircuitMinBits OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Minimum number of bits transmitted in Time Period Tc for this PVC." ::= { frExtCircuitEntry 8 } frExtCircuitMaxBits OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of bits transmitted in Time Period Tc for this PVC." ::= { frExtCircuitEntry 9 } frExtCircuitQOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of octets queued for transmission because the maximum burst rate was achieved in Tc. These are the number of octets that had transmission delay until next excess burst cycle Tc." ::= { frExtCircuitEntry 10 } -- -- The Async Port Level Group -- -- -- The Async Configuration Table: -- asyncConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AsyncConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Async port information." ::= { lineAsyncGroup 1 } asyncConfigEntry OBJECT-TYPE SYNTAX AsyncConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular async port." INDEX { asyncConfigPortIndex } ::= { asyncConfigTable 1 } AsyncConfigEntry ::= SEQUENCE { asyncConfigPortIndex INTEGER, asyncConfigType INTEGER, asyncNAUName DisplayString, asyncInitState INTEGER, asyncCarrier INTEGER, asyncSpeed INTEGER, asyncPhysicalType INTEGER, asyncStopBits INTEGER, asyncParity INTEGER, asyncDataBits INTEGER, asyncIdleTimer INTEGER, asyncTxFrameGap INTEGER, asyncRxForwardingCount INTEGER, asyncEiaSignalForwarding INTEGER, asyncAddressOffset INTEGER, asyncRTC OCTET STRING, asyncCTS INTEGER, asyncDCD INTEGER, asyncDSR INTEGER, asyncDTR INTEGER, asyncRTS INTEGER, asyncReturnClock INTEGER, asyncOrt INTEGER } asyncConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port." ::= { asyncConfigEntry 1 } asyncConfigType OBJECT-TYPE SYNTAX INTEGER { hasc-type(9), tasc-type(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. HASC (Host Async) ports are for attaching to an Async Alarm Central Processor. TASC ports (Terminal Async) ports are for attaching to Alarm Controllers." ::= { asyncConfigEntry 2 } asyncNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { asyncConfigEntry 3 } asyncInitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the async port. If configured for 'in-service', then the Async port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', then the Async port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'." ::= { asyncConfigEntry 4 } asyncCarrier OBJECT-TYPE SYNTAX INTEGER { constant(1), switched(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This field indicates whether Carrier (a.k.a. CD or DCD, RS-232 pin 8) is constant or switched for DCE devices (internally clocked), or Request To Send (a.k.a. RTS, RS-232 pin 4) is constant or switched. The default value for this parameter is 'constant'." ::= { asyncConfigEntry 5 } asyncSpeed OBJECT-TYPE SYNTAX INTEGER { speed75(75), speed150(150), speed300(300), speed600(600), speed1200(1200), speed2400(2400), speed4800(4800), speed9600(9600), speed19200(19200) } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in bits per second. The default value is 300 bits per second. Speeds higher than 19200 are not supported." ::= { asyncConfigEntry 6 } asyncPhysicalType OBJECT-TYPE SYNTAX INTEGER { dte(1), dce(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Physical RS-232 type emulated by the port. The default value is 2 or DCE." ::= { asyncConfigEntry 7 } asyncStopBits OBJECT-TYPE SYNTAX INTEGER { sto1(1), sto1-5(2), sto2(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Number of stop bits generated for transmit characters (received characters may have any number of bits regardless of the configuration). The default value is 1." ::= { asyncConfigEntry 8 } asyncParity OBJECT-TYPE SYNTAX INTEGER { odd(1), even(2), none(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Parity type generated for transmit characters and checked for receive characters. If ODD or EVEN, then if a character is received with invalid parity, it is discarded and the message once completely received is also discarded (i.e. not forwarded to the network). If NONE, then no parity bit is expected within the character or generated to the line. The default value is 1 or NONE." ::= { asyncConfigEntry 9 } asyncDataBits OBJECT-TYPE SYNTAX INTEGER (5..8) ACCESS read-only STATUS mandatory DESCRIPTION "Number of data bits (not including the parity bit). The default value is 8." ::= { asyncConfigEntry 10 } asyncIdleTimer OBJECT-TYPE SYNTAX INTEGER (0..5000) ACCESS read-only STATUS mandatory DESCRIPTION "The idle timer is amount of time (in milliseconds) used to determine when a complete message has been received from the line. If configured as 0, then this timer is disabled and the message will be sent to the network only when the RX forwarding count is reached. If configured greater than 0, then the timer must be configured for a time longer than the time it takes to receive one character, otherwise the timer will not function properly. The default value is 40." ::= { asyncConfigEntry 11 } asyncTxFrameGap OBJECT-TYPE SYNTAX INTEGER (0..5000) ACCESS read-only STATUS mandatory DESCRIPTION "The TX frame gap is analogous to the idle timer, but is used to separate messages received from the network by gaps in time so that the Async device can distinguish between multiple messages. If configured as 0, then this function is disabled and if messages are received while transmitting a current message, the the two messages from the network will be sent out with no gap between them. If configured greater than 0, then a gap of the specified number of milliseconds will be inserted. The default value is 40." ::= { asyncConfigEntry 12 } asyncRxForwardingCount OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "The Async receive forwarding count is used to forward messages when a configured number of characters is received from the Async line. This must be configured to greater than or equal to the maximum message length for a given protocol. The default value is 256." ::= { asyncConfigEntry 13 } asyncEiaSignalForwarding OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Async EIA signal forwarding is used to cause receive data to be forwarding based on a change of EIA RS-232 control signals. If configured as a DCE, and this field is set ot YES, then if the Request To Send (RTS) control signal (RS-232 DB25 pin 4) changes from active to inactive, any characters already received are forwarded and sent to the network. If configured as a DTE, and this field is set to YES, then if the DCD (Data Carrier Detect) control signal (RS-232 DB25 pin 8) changes from active to inactive, forwarding to the network will occur. The default value is 1 or YES." ::= { asyncConfigEntry 14 } asyncAddressOffset OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "If the address offset is specified as zero, then the data is not parsed to find a device address in order to direct the data to a specified LLC connection. If the address offset is 1 to 255, then the 8 bits specified at that offset (where offset 1 is the first byte of a message received) are interpreted as an address. If this field is set 0 zero, then only one CU record is allowed (i.e. all data sent/received to/from the line is to/from one network connection). If this field is greater than 0 (address offset specified) then one or more CU records can be configured to route the data based on the device address. The default value is 1." ::= { asyncConfigEntry 15 } asyncRTC OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether the alarms system protocol has a record termination(forwarding character). The valid range is from hex 01 to hex ff. The default value is not defined." ::= { asyncConfigEntry 16 } asyncCTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { asyncConfigEntry 17 } asyncDCD OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { asyncConfigEntry 18 } asyncDSR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DSR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { asyncConfigEntry 19 } asyncDTR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and DTR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { asyncConfigEntry 20 } asyncRTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and RTS is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { asyncConfigEntry 21 } asyncReturnClock OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), default(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored. The range is yes and no. The default value is 'yes'." ::= { asyncConfigEntry 22 } asyncOrt OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The ORT command is a new port level command. By default, the setting will be YES to set the N2 value to zero, but can be set to NO to indicate that the normal LLC N2 setting should be used. The default value is 'yes'." ::= { asyncConfigEntry 23 } -- -- The Async Port Statistics Table: -- asyncStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AsyncStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Async information." ::= { lineAsyncGroup 2 } asyncStatsEntry OBJECT-TYPE SYNTAX AsyncStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Async port." INDEX { asyncStatsPortIndex } ::= { asyncStatsTable 1 } AsyncStatsEntry ::= SEQUENCE { asyncStatsPortIndex INTEGER, asyncPortType INTEGER, asyncInOctets Counter, asyncOutOctets Counter, asyncInMessages Counter, asyncOutMessages Counter, asyncInMsgDiscarded Counter, asyncOutMsgDiscarded Counter, asyncXmtFailures Counter, asyncRcvMsgForwarded Counter, asyncRcvMsgErrors Counter, asyncRcvCharsDiscarded Counter, asyncRcvParityErrors Counter, asyncRcvFramingErrors Counter, asyncRcvFifoOverruns Counter, asyncRcvCharsOverruns Counter, asyncRcvBreakConditions Counter } asyncStatsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this Async port." ::= { asyncStatsEntry 1 } asyncPortType OBJECT-TYPE SYNTAX INTEGER { hasc-type(9), tasc-type(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. HASC (Host Async) ports are for attaching to an Async Alarm Central Processor. TASC ports (Terminal Async) ports are for attaching to Alarm Controllers." ::= { asyncStatsEntry 2 } asyncInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received." ::= { asyncStatsEntry 3 } asyncOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes sent." ::= { asyncStatsEntry 4 } asyncInMessages OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of messages received." ::= { asyncStatsEntry 5 } asyncOutMessages OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of messages sent." ::= { asyncStatsEntry 6 } asyncInMsgDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received messages discarded." ::= { asyncStatsEntry 7 } asyncOutMsgDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of sent messages discarded." ::= { asyncStatsEntry 8 } asyncXmtFailures OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of failures in transmission." ::= { asyncStatsEntry 9 } asyncRcvMsgForwarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received messages forwarded." ::= { asyncStatsEntry 10 } asyncRcvMsgErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of errors detected in receiving messages." ::= { asyncStatsEntry 11 } asyncRcvCharsDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received characters discarded." ::= { asyncStatsEntry 12 } asyncRcvParityErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of parity errors detected." ::= { asyncStatsEntry 13 } asyncRcvFramingErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of errors detected in receiving frames." ::= { asyncStatsEntry 14 } asyncRcvFifoOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number FIFO receive overruns detected." ::= { asyncStatsEntry 15 } asyncRcvCharsOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of character receive overruns detected." ::= { asyncStatsEntry 16 } asyncRcvBreakConditions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receive break conditions." ::= { asyncStatsEntry 17 } -- -- The Bisync RJE Port Level Group -- -- -- The Bisync RJE Configuration Table: -- bisyncrjeConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF BisyncrjeConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Bisync port information." ::= { lineBisyncRjeGroup 1 } bisyncrjeConfigEntry OBJECT-TYPE SYNTAX BisyncrjeConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Bisync port." INDEX { bisyncrjeConfigPortIndex } ::= { bisyncrjeConfigTable 1 } BisyncrjeConfigEntry ::= SEQUENCE { bisyncrjeConfigPortIndex INTEGER, bisyncrjeConfigType INTEGER, bisyncrjeNAUName DisplayString, bisyncrjeInitState INTEGER, bisyncrjeCarrier INTEGER, bisyncrjeClocking INTEGER, bisyncrjeSpeed INTEGER, bisyncrjeReplyTimer INTEGER, bisyncrjeRetries INTEGER, bisyncrjeCodeSet INTEGER, bisyncrjeCTS INTEGER, bisyncrjeDCD INTEGER, bisyncrjeDSR INTEGER, bisyncrjeDTR INTEGER, bisyncrjeRTS INTEGER, bisyncrjeReturnClock INTEGER } bisyncrjeConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port. Current supported Bisync Rje numbers are 1-4." ::= { bisyncrjeConfigEntry 1 } bisyncrjeConfigType OBJECT-TYPE SYNTAX INTEGER { secondaryRJE-type(13), primaryRJE-type(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. PRJE (Primary RJE) ports emulate a Host and polls the downstream controllers). SRJE ports (Secondary RJE) ports emulate a line with Terminal Controllers (CUs) and respond to polls from the Host." ::= { bisyncrjeConfigEntry 2 } bisyncrjeNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { bisyncrjeConfigEntry 3 } bisyncrjeInitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the Bisync RJE port. If configured for 'in-service', then the Bisync RJE port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', then the Bisync RJE port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'." ::= { bisyncrjeConfigEntry 4 } bisyncrjeCarrier OBJECT-TYPE SYNTAX INTEGER { constant(1), switched(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This field indicates whether Carrier is constant or switched. The default value for this parameter is 'constant'." ::= { bisyncrjeConfigEntry 5 } bisyncrjeClocking OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Clocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. The default value for this field is 'external'." ::= { bisyncrjeConfigEntry 6 } bisyncrjeSpeed OBJECT-TYPE SYNTAX INTEGER { speed1200(12), speed2000(20), speed2400(24), speed3600(36), speed4800(48), speed7200(72), speed9600(96), speed14400(144), speed19200(192), speed28800(288), speed48000(480), speed56000(560), speed64000(640), speed128000(1280) } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 128000 are not supported." ::= { bisyncrjeConfigEntry 7 } bisyncrjeReplyTimer OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-only STATUS mandatory DESCRIPTION "The time to wait for a response in seconds. The default value for this field is 3 seconds." ::= { bisyncrjeConfigEntry 8 } bisyncrjeRetries OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of retries (N2 value) before failing a CU. The default value for this field is 8." ::= { bisyncrjeConfigEntry 9 } bisyncrjeCodeSet OBJECT-TYPE SYNTAX INTEGER { ascii(1), ebcdic(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter sets code set to be used for RJE line. The range of this parameter is ASCII and EBCDIC. The default value for this field is EBCDIC." ::= { bisyncrjeConfigEntry 10 } bisyncrjeCTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { bisyncrjeConfigEntry 11 } bisyncrjeDCD OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { bisyncrjeConfigEntry 12 } bisyncrjeDSR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DSR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { bisyncrjeConfigEntry 13 } bisyncrjeDTR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and DTR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { bisyncrjeConfigEntry 14 } bisyncrjeRTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and RTS is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { bisyncrjeConfigEntry 15 } bisyncrjeReturnClock OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), default(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored. The range is yes and no. The default value is 'yes'." ::= { bisyncrjeConfigEntry 16 } -- -- The Bisync RJE Port Statistics Table: -- bisyncrjeStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF BisyncrjeStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Bisync information." ::= { lineBisyncRjeGroup 2 } bisyncrjeStatsEntry OBJECT-TYPE SYNTAX BisyncrjeStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Bisync port." INDEX { bisyncrjeStatsPortIndex } ::= { bisyncrjeStatsTable 1 } BisyncrjeStatsEntry ::= SEQUENCE { bisyncrjeStatsPortIndex INTEGER, bisyncrjePortType INTEGER, bisyncrjeInChrs Counter, bisyncrjeOutChrs Counter, bisyncrjeInTrns Counter, bisyncrjeOutTrns Counter, bisyncrjeInRetr Counter, bisyncrjeOutRetr Counter, bisyncrjeInEnq Counter, bisyncrjeOutEnq Counter, bisyncrjeInEtb Counter, bisyncrjeOutEtb Counter, bisyncrjeInEtx Counter, bisyncrjeOutEtx Counter, bisyncrjeWack Counter, bisyncrjeRvi Counter } bisyncrjeStatsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this Bisync RJE port. Current supported numbers are 1-4." ::= { bisyncrjeStatsEntry 1 } bisyncrjePortType OBJECT-TYPE SYNTAX INTEGER { srje-SecondaryRJE(13), prje-PrimaryRJE(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type." ::= { bisyncrjeStatsEntry 2 } bisyncrjeInChrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Characters received." ::= { bisyncrjeStatsEntry 3 } bisyncrjeOutChrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Characters sent." ::= { bisyncrjeStatsEntry 4 } bisyncrjeInTrns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Transactions received." ::= { bisyncrjeStatsEntry 5 } bisyncrjeOutTrns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Transactions sent." ::= { bisyncrjeStatsEntry 6 } bisyncrjeInRetr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Retransmits received." ::= { bisyncrjeStatsEntry 7 } bisyncrjeOutRetr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Retransmits sent." ::= { bisyncrjeStatsEntry 8 } bisyncrjeInEnq OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ENQ received." ::= { bisyncrjeStatsEntry 9 } bisyncrjeOutEnq OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ENQ sent." ::= { bisyncrjeStatsEntry 10 } bisyncrjeInEtb OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ETB received." ::= { bisyncrjeStatsEntry 11 } bisyncrjeOutEtb OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ETB sent." ::= { bisyncrjeStatsEntry 12 } bisyncrjeInEtx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ETX received." ::= { bisyncrjeStatsEntry 13 } bisyncrjeOutEtx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of ETX sent." ::= { bisyncrjeStatsEntry 14 } bisyncrjeWack OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of WACK received." ::= { bisyncrjeStatsEntry 15 } bisyncrjeRvi OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RVI received." ::= { bisyncrjeStatsEntry 16 } -- -- The Dial Backup Port Level Group -- -- -- The Dial Backup Configuration Table: -- dialbackupConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF DialbackupConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Sync product dial backup information." ::= { lineDialBackupGroup 1 } dialbackupConfigEntry OBJECT-TYPE SYNTAX DialbackupConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Sync product dial backup port." INDEX { dialbackupConfigPortIndex } ::= { dialbackupConfigTable 1 } DialbackupConfigEntry ::= SEQUENCE { dialbackupConfigPortIndex INTEGER, dialbackupPortType INTEGER, dialbackupConnectType INTEGER, dialbackupFirstDedicatedPort INTEGER, dialbackupassociatedDLCIDedicated INTEGER, dialbackupSecondDedicatedPort INTEGER, dialbackupassociatedDLCISecond INTEGER, dialbackupDedicatedPort INTEGER, dialbackupDedicatedLMIPort INTEGER, dialbackupDialInactivityTimer INTEGER, dialbackupDialSuspendTimer INTEGER, dialbackupModemInitString DisplayString, dialbackupModemDialString DisplayString, dialbackupModemHangString DisplayString, dialbackupDialDelayTimer INTEGER, dialbackupTreatLLCControlCharacters INTEGER } dialbackupConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This port uniquely identifies the dial backup port. Range is a valid port number." ::= { dialbackupConfigEntry 1 } dialbackupPortType OBJECT-TYPE SYNTAX INTEGER { frame-relay-dialbackup-type(20) } ACCESS read-only STATUS mandatory DESCRIPTION "The Dial backup connect Type." ::= { dialbackupConfigEntry 2 } dialbackupConnectType OBJECT-TYPE SYNTAX INTEGER { hayes(1), vtwentyfivebis(2), nullmodem(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The Dial backup connect Type." ::= { dialbackupConfigEntry 3 } dialbackupFirstDedicatedPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This defines a frame relay PVC which will cause dial backup if it is declared as failed (deactivated) by the network. Port number is a valid Frame Relay and DLCI is a valid Frame Relay DLCI." ::= { dialbackupConfigEntry 4 } dialbackupassociatedDLCIDedicated OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This defines a frame relay PVC which will cause dial backup if it is declared as failed (deactivated) by the network. DLCI is a valid Frame Relay DLCI." ::= { dialbackupConfigEntry 5 } dialbackupSecondDedicatedPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This defines a second frame relay PVC which will cause dial backup if it is declared as failed (deactivated) by the network. Port number is a valid Frame Relay and DLCI is a valid Frame Relay DLCI." ::= { dialbackupConfigEntry 6 } dialbackupassociatedDLCISecond OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This defines a second frame relay PVC which will cause dial backup if it is declared as failed (deactivated) by the network. DLCI is a valid Frame Relay DLCI." ::= { dialbackupConfigEntry 7 } dialbackupDedicatedPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When this port fails, dial connection is activated. Range is a valid port number. The default value for this field is 1." ::= { dialbackupConfigEntry 8 } dialbackupDedicatedLMIPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When this port looses LMI connectivity, dial connection is activated. Range is a valid number. The default value for this field is 1." ::= { dialbackupConfigEntry 9} dialbackupDialInactivityTimer OBJECT-TYPE SYNTAX INTEGER (0..9999) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines inactivity timer for dial connection. Expiration of this timer will cause dial connection to disconnect. The range of this parameter is 0..9999 seconds. Value 0 disables inactivity timer usage. The default value for this field is 60 seconds." ::= { dialbackupConfigEntry 10 } dialbackupDialSuspendTimer OBJECT-TYPE SYNTAX INTEGER (0..9999) ACCESS read-only STATUS mandatory DESCRIPTION "Defines a duration for which the dial connection. will not be attempted after the dial connection is torn down. The range is 0..9999 seconds. Value of 0 disable inactivity timer usage. The default value for this field is 60 seconds." ::= { dialbackupConfigEntry 11 } dialbackupModemInitString OBJECT-TYPE SYNTAX DisplayString (SIZE(1..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Defins a modem intialization string. The field is 40 characters long. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { dialbackupConfigEntry 12 } dialbackupModemDialString OBJECT-TYPE SYNTAX DisplayString (SIZE(1..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Defins a modem dial string to activate dial connection. This field is up to 40 characters long. Dial phone number may be specified here. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { dialbackupConfigEntry 13 } dialbackupModemHangString OBJECT-TYPE SYNTAX DisplayString (SIZE(1..20)) ACCESS read-only STATUS mandatory DESCRIPTION "Defines a modem hang up string to deactivate dial connection. This field is up to 20 characters long. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { dialbackupConfigEntry 14 } dialbackupDialDelayTimer OBJECT-TYPE SYNTAX INTEGER (0..9999) ACCESS read-only STATUS mandatory DESCRIPTION "Defines a duration for which the dial connecton will not be attempted after need to initiate dial connection is detected. The range of this parameter is 0..9999 seconds. Value 0 implies immediate dial initiation. The default value for this field is 60 seconds." ::= { dialbackupConfigEntry 15 } dialbackupTreatLLCControlCharacters OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether LLC control frames (TEST, XID, RR, RNR, REJ, DISC, UA, DM, FRMR etc. except I frames) are to be considered as user data or not. For a dial backup up port if this contorl frames are not treated as user data, then idle LLC2 sessions on the port will cause inactivity timer to pop causing SNA session disconnect. The range of this parameter is YES or NO. Default value is YES" ::= { dialbackupConfigEntry 16 } -- -- The Dial Backup Port Statistics Table: -- dialbackupStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF DialbackupStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Frame Relay information." ::= { lineDialBackupGroup 2 } dialbackupStatsEntry OBJECT-TYPE SYNTAX DialbackupStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular Frame Relay port." INDEX { dialbackupStatsPortIndex } ::= { dialbackupStatsTable 1 } DialbackupStatsEntry ::= SEQUENCE { dialbackupStatsPortIndex INTEGER, dialbackupSuccatmpt Counter, dialbackupunsuccatmpt Counter, dialbackupinact Counter } dialbackupStatsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this Dial Backup port." ::= { dialbackupStatsEntry 1 } dialbackupSuccatmpt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of successful dial backup attempts." ::= { dialbackupStatsEntry 2 } dialbackupunsuccatmpt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of unsuccessful dial backup attempts." ::= { dialbackupStatsEntry 3 } dialbackupinact OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The Number of times inactivity timer expired." ::= { dialbackupStatsEntry 4 } -- -- The X25 Configuration Table: -- x25ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF X25ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of X25 information." ::= { lineX25Group 1 } x25ConfigEntry OBJECT-TYPE SYNTAX X25ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular X25 port." INDEX { x25ConfigPortIndex } ::= { x25ConfigTable 1 } X25ConfigEntry ::= SEQUENCE { x25ConfigPortIndex INTEGER, x25ConfigType INTEGER, x25NAUName DisplayString, x25InitState INTEGER, x25Clocking INTEGER, x25DTEAddress OCTET STRING, x25LinkWindowSize INTEGER, x25T1Timer INTEGER, x25MaxRetries INTEGER, x25PortSpeed INTEGER, x25ReceiveWindowSize INTEGER, x25TransmitWindowSize INTEGER, x25ReceivePacketSize INTEGER, x25TransmitPacketSize INTEGER, x25LowTwoWayChannel INTEGER, x25HighTwoWayChannel INTEGER, x25UseCallingAddress INTEGER, x25ForwardingUnit INTEGER, x25DevicePacketSize INTEGER, x25DeviceWindowSize INTEGER, x25PlaceReverseChargeCalls INTEGER, x25AcceptReverseChargeCalls INTEGER, x25NPS INTEGER, x25CTS INTEGER, x25DCD INTEGER, x25DSR INTEGER, x25DTR INTEGER, x25RTS INTEGER, x25ReturnClock INTEGER, x25IPAddress IpAddress, x25NetworkMask IpAddress, x25DefaultGatewayAddress IpAddress, x25SecondDefaultGatewayAddress IpAddress } x25ConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port. Current supported X.25 numbers are 1-4." ::= { x25ConfigEntry 1 } x25ConfigType OBJECT-TYPE SYNTAX INTEGER { xDTE-XLogicalDTE(7), xDCE-XLogicalDCE(8) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. XDCE () ports is a logical DCE device waits to receive an incoming call from the X.25 network. XDTE ports is a logical DTE device initiates a to the X.25 network. Note that all ports must currently be defined as the same time for a given unit (i.e. no mixing of XDCE and XDTE ports is allowed)." ::= { x25ConfigEntry 2 } x25NAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { x25ConfigEntry 3 } x25InitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the X.25 port. If configured for 'in-service', then the X.25 port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the X.25 port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'." ::= { x25ConfigEntry 4 } x25Clocking OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2), x21-external(3), x21-internal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Clocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. X21 External and Internal are used (with the proper external adapter) to support X.21 Leased Line operation for RS-422/RS-530 (25 pin balanced) interfaces. X21 operation is not supported for boards that operate RS-232 or V.35. The default value for this field is 'external'." ::= { x25ConfigEntry 5 } x25DTEAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the DTE address this port will use to access the X.25 network." ::= { x25ConfigEntry 6 } x25LinkWindowSize OBJECT-TYPE SYNTAX INTEGER(1..7) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter sets the maximum number of concurrent unacknowledged I frames at the X.25 data link level. The default value is 7." ::= { x25ConfigEntry 7 } x25T1Timer OBJECT-TYPE SYNTAX INTEGER(1..1980) ACCESS read-only STATUS mandatory DESCRIPTION "The SDLC T1 timer value in 20ths of a second. The default value is 60 (3 seconds)." ::= { x25ConfigEntry 8 } x25MaxRetries OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of retries (N2 value) before failing a PU. The default value for this field is 8." ::= { x25ConfigEntry 9 } x25PortSpeed OBJECT-TYPE SYNTAX INTEGER { speed2000(20), speed2400(24), speed3600(36), speed4800(48), speed7200(72), speed9600(96), speed14400(144), speed19200(192), speed28800(288), speed48000(480), speed56000(560), speed64000(640), speed128000(1280), speed256000(2560) } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in 100 bits per second. The default value is 64000 bits per second. Speeds higher than 19200 are not supported on RS-232 ports units (must be V.35 or RS-422)." ::= { x25ConfigEntry 10 } x25ReceiveWindowSize OBJECT-TYPE SYNTAX INTEGER(1..7) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter determines the number of consecutive data packets that the sync unit can receive before requiring an acknowledgment. The default value is 2." ::= { x25ConfigEntry 11 } x25TransmitWindowSize OBJECT-TYPE SYNTAX INTEGER(1..7) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter determines the number of consecutive data packets to be transmitted on the X.25 network before requiring an acknowledgment. The value you configure in this field must match the value configured in the X.25 network. The default value is 2." ::= { x25ConfigEntry 12 } x25ReceivePacketSize OBJECT-TYPE SYNTAX INTEGER { sixteen(16), thirtytwo(32), onetwentyeight(128), twofiftsix(256), fivetwelve(512), onethousand(1024) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the size of packets received from the X.25 network in bytes. This value must match the configuration of your X.25 network provider. The default value is 128 bytes." ::= { x25ConfigEntry 13 } x25TransmitPacketSize OBJECT-TYPE SYNTAX INTEGER { sixteen(16), thirtytwo(32), onetwentyeight(128), twofiftsix(256), fivetwelve(512), onethousand(1024) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the size of packets transmitted across the X.25 network in bytes. This value must match the configuration of the X.25 network. The default value is 128 bytes." ::= { x25ConfigEntry 14 } x25LowTwoWayChannel OBJECT-TYPE SYNTAX INTEGER(1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the X.25 packet lower-bound channel number for this physical access line. The default value is 1." ::= { x25ConfigEntry 15 } x25HighTwoWayChannel OBJECT-TYPE SYNTAX INTEGER(1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the X.25 packet upper-bound channel number for this physical access line. Note: This value must be greater than the Low Two-Way Channel Number. The default value is 127." ::= { x25ConfigEntry 16 } x25UseCallingAddress OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter determines whether the DTE Address assigned to the port you are configuring should be included as a calling address in outgoing call packets. The default value is 'No'." ::= { x25ConfigEntry 17 } x25ForwardingUnit OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), three(3), four(4), five(5), six(6), seven(7), eom(8) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter limits how many message packets can accumulate before the unit forwards them to higher bytes. The default value is 'EOM'." ::= { x25ConfigEntry 18 } x25DevicePacketSize OBJECT-TYPE SYNTAX INTEGER { thirtytwo(32), onetwentyeight(128), twofiftsix(256), fivetwelve(512), onethousand(1024), none(1) } ACCESS read-only STATUS mandatory DESCRIPTION "When the sync unit makes a call on behalf of any configured device, the packet size determines parameter negotiation between the calling and the called packet handlers. Note: This parameter is not currently supported. do no change the default value. The default value is 'NONE'." ::= { x25ConfigEntry 19 } x25DeviceWindowSize OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), three(3), four(4), five(5), six(6), seven(7), none(8) } ACCESS read-only STATUS mandatory DESCRIPTION "When the sync unit makes a call on behalf of any device, the window size determines parameter negotiation between the calling and the called packet handlers. Note: This parameter is not currently supported. do no change the default value. The default value is 'NONE'." ::= { x25ConfigEntry 20 } x25PlaceReverseChargeCalls OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter determines whether the Sync unit will place reverse charge requests on outgoing calls. The default value is 'No'." ::= { x25ConfigEntry 21 } x25AcceptReverseChargeCalls OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter determines whether the Sync unit will accept reverse charge requests from incoming calls. The default value is 'No'." ::= { x25ConfigEntry 22 } x25NPS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates if the QLLC conversion NODE is connecting to a NPSI front-end and is to take on a secondary role. The default value is 'No'." ::= { x25ConfigEntry 23 } x25CTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { x25ConfigEntry 24 } x25DCD OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { x25ConfigEntry 25 } x25DSR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DSR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { x25ConfigEntry 26 } x25DTR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and DTR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { x25ConfigEntry 27 } x25RTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and RTS is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { x25ConfigEntry 28 } x25ReturnClock OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), default(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored. The range is yes and no. The default value is 'yes'." ::= { x25ConfigEntry 29 } x25IPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the IP Address of this interface." ::= { x25ConfigEntry 30 } x25NetworkMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This is the network mask to be used on this interface." ::= { x25ConfigEntry 31 } x25DefaultGatewayAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Default gateway address to be used when sending responses on this interface." ::= { x25ConfigEntry 32 } x25SecondDefaultGatewayAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Second Default gateway address to be used when sending responses on this interface." ::= { x25ConfigEntry 33 } -- -- The X25 Port Statistics Table: -- x25StatsTable OBJECT-TYPE SYNTAX SEQUENCE OF X25StatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of X25 information." ::= { lineX25Group 2 } x25StatsEntry OBJECT-TYPE SYNTAX X25StatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular X25 port." INDEX { x25StatsPortIndex } ::= { x25StatsTable 1 } X25StatsEntry ::= SEQUENCE { x25StatsPortIndex INTEGER, x25PortType INTEGER, x25InFrames Counter, x25OutFrames Counter, x25CInFrames Counter, x25COutFrames Counter, x25FRMRInFrames Counter, x25FRMROutFrames Counter, x25Timeouts Counter, x25UFrames Counter, x25Samples Counter, x25Sum Counter, x25SumsQ Counter, x25DataInPkts Counter, x25DataOutPkts Counter, x25DataInChrs Counter, x25DataOutChrs Counter, x25QInPkts Counter, x25QOutPkts Counter, x25QInChrs Counter, x25QOutChrs Counter, x25SigInPkts Counter, x25SigOutPkts Counter, x25InResets Counter, x25OutResets Counter, x25InRestarts Counter, x25OutRestarts Counter } x25StatsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this X25 port. Current supported numbers on are 1-8." ::= { x25StatsEntry 1 } x25PortType OBJECT-TYPE SYNTAX INTEGER { xDTE-XLogicalDTE(7), xDCE-XLogicalDCE(8) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. XDCE () ports is a logical DCE device waits to receive an incoming call from the X.25 network. XDTE ports is a logical DTE device initiates a to the X.25 network. Note that all ports must currently be defined as the same time for a given unit (i.e. no mixing of XDCE and XDTE ports is allowed)." ::= { x25StatsEntry 2 } x25InFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of I-frames received." ::= { x25StatsEntry 3 } x25OutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of I-frames sent." ::= { x25StatsEntry 4 } x25CInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Control-frames received." ::= { x25StatsEntry 5 } x25COutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Control-frames sent." ::= { x25StatsEntry 6 } x25FRMRInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FRMR-frames received." ::= { x25StatsEntry 7 } x25FRMROutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FRMR-frames sent." ::= { x25StatsEntry 8 } x25Timeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Timeouts." ::= { x25StatsEntry 9 } x25UFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Undefined Frames." ::= { x25StatsEntry 10 } x25Samples OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Samples." ::= { x25StatsEntry 11 } x25Sum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Active Channels Sum." ::= { x25StatsEntry 12 } x25SumsQ OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Active Channels SumsQ." ::= { x25StatsEntry 13 } x25DataInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Data Packets received." ::= { x25StatsEntry 14 } x25DataOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Data Packets sent." ::= { x25StatsEntry 15 } x25DataInChrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Data Characters received." ::= { x25StatsEntry 16 } x25DataOutChrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Data Characters sent." ::= { x25StatsEntry 17 } x25QInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Q-Packets received." ::= { x25StatsEntry 18 } x25QOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Q-Packets sent." ::= { x25StatsEntry 19 } x25QInChrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Q-Characters received." ::= { x25StatsEntry 20 } x25QOutChrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Q-Characters sent." ::= { x25StatsEntry 21 } x25SigInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Sig-Packets received." ::= { x25StatsEntry 22 } x25SigOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Sig-Packets sent." ::= { x25StatsEntry 23 } x25InResets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Resets received." ::= { x25StatsEntry 24 } x25OutResets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Resets sent." ::= { x25StatsEntry 25 } x25InRestarts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Restarts received." ::= { x25StatsEntry 26 } x25OutRestarts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Restarts sent." ::= { x25StatsEntry 27 } -- -- The ALC Configuration Table: -- alcConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AlcConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of ALC information." ::= { lineAlcGroup 1 } alcConfigEntry OBJECT-TYPE SYNTAX AlcConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular ALC port." INDEX { alcConfigPortIndex } ::= { alcConfigTable 1 } AlcConfigEntry ::= SEQUENCE { alcConfigPortIndex INTEGER, alcConfigType INTEGER, alcNAUName DisplayString, alcInitState INTEGER, alcClocking INTEGER, alcPortSpeed INTEGER, alcLimitSegsCharsBetweenPolls INTEGER, alcNumberOfSegments INTEGER, alcNumberOfCharacters INTEGER, alcNumberOfNullSeg INTEGER, alcCTS INTEGER, alcDCD INTEGER, alcDSR INTEGER, alcDTR INTEGER, alcRTS INTEGER, alcReturnClock INTEGER } alcConfigPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this port. Current supported X.25 numbers are 1-4." ::= { alcConfigEntry 1 } alcConfigType OBJECT-TYPE SYNTAX INTEGER { tALC-TerminalALC(23), hALC-HostALC(24) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. The default is Teminal ALC." ::= { alcConfigEntry 2 } alcNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { alcConfigEntry 3 } alcInitState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the X.25 port. If configured for 'in-service', then the ALC port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the ALC port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'inservice'." ::= { alcConfigEntry 4 } alcClocking OBJECT-TYPE SYNTAX INTEGER { external(1), internal(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Clocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. The default value for this field is 'internal'." ::= { alcConfigEntry 5 } alcPortSpeed OBJECT-TYPE SYNTAX INTEGER { speed1200(12), speed2400(24), speed4800(48), speed9600(96), speed19200(192) } ACCESS read-only STATUS mandatory DESCRIPTION "The ports speed in 100 bits per second. The default value is 9600 bits per second." ::= { alcConfigEntry 6 } alcLimitSegsCharsBetweenPolls OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies whether to limit the number of segments sent between pools. If this parameter is set to 'yes' the parameter 'Number of Segments' and 'Number of Characters' should be configured appropriately. The defualt value is 'yes'." ::= { alcConfigEntry 7 } alcNumberOfSegments OBJECT-TYPE SYNTAX INTEGER (3..99) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the maximum number of segments that may be sent between polls. This parameter is applicable only if 'Limit SEGs/Chars between polls' is set to yes. The defualt value is 5." ::= { alcConfigEntry 8 } alcNumberOfCharacters OBJECT-TYPE SYNTAX INTEGER (500..9999) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the maximum number of characters that may be sent between polls. This parameter is applicable only if 'Limit SEGs/Chars between polls' is set to yes. The defualt value is 2000." ::= { alcConfigEntry 9 } alcNumberOfNullSeg OBJECT-TYPE SYNTAX INTEGER (0..10) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the maximum number of null characters that may be sent between segments. The defualt value is 0." ::= { alcConfigEntry 10 } alcCTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether CTS is an input signal used to determine the port status. This parameter is applicable if clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { alcConfigEntry 11 } alcDCD OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DCD is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DCD is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { alcConfigEntry 12 } alcDSR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DSR is required as input signal or ignored. This parameter is applicable if the clocking is set to external. For internal clocking the parameter is ignored and DSR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { alcConfigEntry 13 } alcDTR OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether DTR is required as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and DTR is asserted when port is enabled. The range is yes and no. The default value is 'yes'." ::= { alcConfigEntry 14 } alcRTS OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether RTS is an input signal to determine the port status. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored and RTS is asserted when port is enabled. The range is yes and no. The default value is 'No'." ::= { alcConfigEntry 15 } alcReturnClock OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), default(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Defines whether Return Clock (SCTE) is available as input signal or ignored. This parameter is applicable if the clocking is set to internal. For external clocking the parameter is ignored. The range is yes and no. The default value is 'yes'." ::= { alcConfigEntry 16 } -- -- The Alc Port Statistics Table: -- alcStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AlcStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of X25 information." ::= { lineAlcGroup 2 } alcStatsEntry OBJECT-TYPE SYNTAX AlcStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of port information for a particular X25 port." INDEX { alcStatsPortIndex } ::= { alcStatsTable 1 } AlcStatsEntry ::= SEQUENCE { alcStatsPortIndex INTEGER, alcPortType INTEGER, alcRxOverruns Counter, alcBytesRx Counter, alcBytesTx Counter, alcBytesRxDisc Counter, alcBytesTxDisc Counter, alcPortFaults Counter, alcRcvCCCErrors Counter, alcPollTx Counter, alcResponseTimeouts Counter, alcSegRx Counter, alcSegTx Counter, alcSegRxDisc Counter, alcSegTxDisc Counter } alcStatsPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that uniquely identifies this Alc port. Current supported numbers on are 1-8." ::= { alcStatsEntry 1 } alcPortType OBJECT-TYPE SYNTAX INTEGER { tALC-TerminalALC(23), hALC-HostALC(24) } ACCESS read-only STATUS mandatory DESCRIPTION "The port type. The default is Terminal Alc." ::= { alcStatsEntry 2 } alcRxOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Received Overruns." ::= { alcStatsEntry 3 } alcBytesRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes Received." ::= { alcStatsEntry 4 } alcBytesTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes Transmitted." ::= { alcStatsEntry 5 } alcBytesRxDisc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes Received." ::= { alcStatsEntry 6 } alcBytesTxDisc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes Transmitted." ::= { alcStatsEntry 7 } alcPortFaults OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes Transmitted." ::= { alcStatsEntry 8 } alcRcvCCCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes Transmitted." ::= { alcStatsEntry 9 } alcPollTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes Transmitted." ::= { alcStatsEntry 10 } alcResponseTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes Transmitted." ::= { alcStatsEntry 11 } alcSegRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Segments Received." ::= { alcStatsEntry 12 } alcSegTx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Segments Transmitted." ::= { alcStatsEntry 13 } alcSegRxDisc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Received Segments Discarded." ::= { alcStatsEntry 14 } alcSegTxDisc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Transmitted Segments Discarded." ::= { alcStatsEntry 15 } -- -- The PU Control Group -- puControlTable OBJECT-TYPE SYNTAX SEQUENCE OF PuControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for controlling lines and obtaining information." ::= { puControlGroup 1 } puControlEntry OBJECT-TYPE SYNTAX PuControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of PU information for a particular port." INDEX { puControlLineIndex, puControlPUAddress } ::= { puControlTable 1 } PuControlEntry ::= SEQUENCE { puControlLineIndex INTEGER, puControlPUAddress OCTET STRING, puStatus INTEGER, puConnectionStatus INTEGER, puLastClearCode OCTET STRING, puControlFailureCode OCTET STRING, puControlNAUName DisplayString, puConnectionAttemptCount INTEGER, puStatusIgnored INTEGER, puStatusAcknowledged INTEGER, puLastDlciCleared INTEGER, puCurrentDlci INTEGER, puLastMACCleared PhysAddress, puCurrentMAC PhysAddress, puNetworkType INTEGER, puCurrentConnectionType INTEGER, puLastSVCCleared INTEGER, puCurrentSVC INTEGER, puLastLocalDTECleared OCTET STRING, puLastRemoteDTECleared OCTET STRING, puCurrentLocalDTE OCTET STRING, puCurrentRemoteDTE OCTET STRING, puIsDynamic INTEGER } puControlLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number that has a given PU." ::= { puControlEntry 1 } puControlPUAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x01 to 0xfe." ::= { puControlEntry 2 } puStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), failed(3), restart(4), enable-all(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the PU. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. Commands: An enable command will attempt to bring up the PU. An enable all command will attempt to bring up the line and any lower layer entities (e.g. PUs). A disable command will disable the PU. Status: Enable(d) indicates the PU is enabled and running. Disable(d) indicates the PU has been disabled. Failed indicates the PU is enabled and not Running. For a access LAN/X25 PU, the status is enabled when the connection status is connected. Otherwise its status is failed." ::= { puControlEntry 3 } puConnectionStatus OBJECT-TYPE SYNTAX INTEGER { connected(1), not-connected(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the LLC type 2 Connection for this SDLC PU." ::= { puControlEntry 4 } puLastClearCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "A two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed connection attempt (a.k.a. call attempt) or active connection (a.k.a. session). For LLC type 2 connections the second octet (cause) is always 0. The first octet (diagnostic) indicates the reason for the last connection failure. A value of 255 (xff) indicates that no call has ever been placed (e.g. PU never came up) or received. Even if the session call attempt is successful, the first octect still indicates the reason of LAST TIME when the session call attempt failed. See User's Guide for information" ::= { puControlEntry 5 } puControlFailureCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the failure codes if the associated PU is in the failed state." ::= { puControlEntry 6 } puControlNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { puControlEntry 7 } puConnectionAttemptCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of connection attempts performed. This count is set to zero at startup, and after every loss of an estabished session." ::= { puControlEntry 8 } puStatusIgnored OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. The status of this pu is not put into consideration when consolidating status of the unit if this field is set to yes." ::= { puControlEntry 9 } puStatusAcknowledged OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This field is used for consolidating status of the unit. When this field is set to yes, the unit will re-consolidate its status without putting the status of this pu into consideration. Subseqent status change of the pu will cause the unit to include it in computing the status of the unit. Setting this value to no has no effect." ::= { puControlEntry 10 } puLastDlciCleared OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the dlci that the last clear code was associated with. If the last clear code was not associated with a virtual route, i.e. the clear was associated with the lan for example, this field is set to 9999." ::= { puControlEntry 11 } puCurrentDlci OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the DLCI active for a session at this time. For LAN or X25 network interface, this field is set to 0" ::= { puControlEntry 12 } puLastMACCleared OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the MAC address that the last clear code was associated with." ::= { puControlEntry 13 } puCurrentMAC OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the MAC address that the current session is associated with. For X25 network type, this is set to 0." ::= { puControlEntry 14 } puNetworkType OBJECT-TYPE SYNTAX INTEGER { xDTE-XLogicalDTE(7), xDCE-XLogicalDCE(8), ethernet-type(17), frame-relay-type(19), frame-relay-dialbackup-type(20), token-ring-type(21) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies netowrk type that the current session is associated with." ::= { puControlEntry 15 } puCurrentConnectionType OBJECT-TYPE SYNTAX INTEGER { dsp (1), qllc (2), llc2 (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies network layer that the current session is associated with." ::= { puControlEntry 16 } puLastSVCCleared OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the LCN that the last clear code is associated with. If the last clear code was not associated with a X25 SVC, i.e. the clear was associated with the lan for example, this field is set to 9999." ::= { puControlEntry 17 } puCurrentSVC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the that the current session is associated with. For non X25 network type, this field is set to 0" ::= { puControlEntry 18 } puLastLocalDTECleared OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the local DTE address that the last clear code is associated with. For non X25 network type, this field is set to 0" ::= { puControlEntry 19 } puLastRemoteDTECleared OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the remote DTE address that the last clear code is associated with. For non X25 network type, this field is set to 0" ::= { puControlEntry 20 } puCurrentLocalDTE OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the local DTE address that the current session is associated with. For non X25 network type, this field is set to 0" ::= { puControlEntry 21 } puCurrentRemoteDTE OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the remote DTE address that the current session is associated with. For non X25 network type, this field is set to 0" ::= { puControlEntry 22 } puIsDynamic OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of PU. YES means that the PU is a dynamic pu created by auto LLC. The puStatus for any dynamic PU must be enabled" ::= { puControlEntry 23 } -- -- The PU Configuration Group -- -- The PU Configuration Group contains information on the lines' -- configured PUs. sdlcPuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SdlcPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU entries." ::= { puSDLCGroup 1 } sdlcPuConfigEntry OBJECT-TYPE SYNTAX SdlcPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { sdlcPuConfigLineIndex, sdlcPuConfigAddress } ::= { sdlcPuConfigTable 1 } SdlcPuConfigEntry ::= SEQUENCE { sdlcPuConfigLineIndex INTEGER, sdlcPuConfigAddress OCTET STRING, sdlcPuNAUName DisplayString, sdlcPuInitialState INTEGER, sdlcPuXID OCTET STRING, sdlcPuType INTEGER, sdlcPuGroupPollAddress OCTET STRING, sdlcPuConnectionID OCTET STRING, sdlcPuMAXOUT INTEGER, sdlcPuConnectType INTEGER } sdlcPuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the line (CU)is configured (first level)." ::= { sdlcPuConfigEntry 1 } sdlcPuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { sdlcPuConfigEntry 2 } sdlcPuNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { sdlcPuConfigEntry 3 } sdlcPuInitialState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the PU. If configured for 'in-service', then the SDLC PU will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the SDLC PU must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'in-service'." ::= { sdlcPuConfigEntry 4 } sdlcPuXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. If the field is configured to 0 then the unit will solicit the XID from the downstream PU and send the XID data received from SDLC to the XID data sent for the LLC connection process. If not sent to 0, then the unit will insert the data configured in the LLC sent to the host during the LLC connection process on behalf of the CU. For incoming LLC connections on Sync Research products this field is parsed to route the connection to the proper PU. The default value for this field is all zeroes (solicit XID from PU)." ::= { sdlcPuConfigEntry 5 } sdlcPuType OBJECT-TYPE SYNTAX INTEGER { type1(1), type2(2), type2-1(3), type4(4), type5(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The SNA PU type. 1 = PU type 1 2 = PU type 2 3 = PU type 2.1 4 = PU type 4 5 = PU type 5 (not supported, reserved) This parameter defaults to a value of 2." ::= { sdlcPuConfigEntry 6 } sdlcPuGroupPollAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU's group address in the range of 0x01 to 0xfe. setting this value to 0 will disable the group poll feature for polling this and other PUs in a group. The default value for this field is 0." ::= { sdlcPuConfigEntry 7 } sdlcPuConnectionID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes." ::= { sdlcPuConfigEntry 8 } sdlcPuMAXOUT OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the maximum number of outstanding I frames that the PU will allow. This field is applicable to TSDLC only." ::= { sdlcPuConfigEntry 9 } sdlcPuConnectType OBJECT-TYPE SYNTAX INTEGER { answer(1), originate(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The SNA PU Connection type." ::= { sdlcPuConfigEntry 10 } -- -- The SDLC PU Statistics Table: -- -- The SDLC PU Statisctics table contains statistical information on the -- lines' configured PUs. sdlcPuStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SdlcPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU statistics entries." ::= { puSDLCGroup 2 } sdlcPuStatsEntry OBJECT-TYPE SYNTAX SdlcPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { sdlcPuStatsLineIndex, sdlcPuStatsAddress } ::= { sdlcPuStatsTable 1 } SdlcPuStatsEntry ::= SEQUENCE { sdlcPuStatsLineIndex INTEGER, sdlcPuStatsAddress OCTET STRING, sdlcPuInIFrames Counter, sdlcPuOutIFrames Counter, sdlcPuInRRFrames Counter, sdlcPuOutRRFrames Counter, sdlcPuInRNRFrames Counter, sdlcPuOutRNRFrames Counter, sdlcPuInXIDFrames Counter, sdlcPuOutXIDFrames Counter, sdlcPuInTESTFrames Counter, sdlcPuOutTESTFrames Counter, sdlcPuInSNRMFrames Counter, sdlcPuOutSNRMFrames Counter, sdlcPuInDISCFrames Counter, sdlcPuOutDISCFrames Counter, sdlcPuInDMFrames Counter, sdlcPuOutDMFrames Counter, sdlcPuInUAFrames Counter, sdlcPuOutUAFrames Counter, sdlcPuInFRMRFrames Counter, sdlcPuOutFRMRFrames Counter, sdlcPuInRDFrames Counter, sdlcPuOutRDFrames Counter, sdlcPuInUIFrames Counter, sdlcPuOutUIFrames Counter, sdlcPuReTxIFrames Counter, sdlcPuPollResponseTimeouts Counter } sdlcPuStatsLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is configured on." ::= { sdlcPuStatsEntry 1 } sdlcPuStatsAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { sdlcPuStatsEntry 2 } sdlcPuInIFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of I frames received on this PU." ::= { sdlcPuStatsEntry 3 } sdlcPuOutIFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of I frames trasnmitted on this PU." ::= { sdlcPuStatsEntry 4 } sdlcPuInRRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RR frames received on this PU." ::= { sdlcPuStatsEntry 5 } sdlcPuOutRRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RR frames transmitted on this PU." ::= { sdlcPuStatsEntry 6 } sdlcPuInRNRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RNR frames received on this PU." ::= { sdlcPuStatsEntry 7 } sdlcPuOutRNRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RNR frames transmitted on this PU." ::= { sdlcPuStatsEntry 8 } sdlcPuInXIDFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of XID frames received on this PU." ::= { sdlcPuStatsEntry 9 } sdlcPuOutXIDFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of XID frames transmitted on this PU." ::= { sdlcPuStatsEntry 10 } sdlcPuInTESTFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of TEST frames received on this PU." ::= { sdlcPuStatsEntry 11 } sdlcPuOutTESTFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of TEST frames transmitted on this PU." ::= { sdlcPuStatsEntry 12 } sdlcPuInSNRMFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of SNRM frames received on this PU." ::= { sdlcPuStatsEntry 13 } sdlcPuOutSNRMFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of SNRM frames transmitted on this PU." ::= { sdlcPuStatsEntry 14 } sdlcPuInDISCFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DISC frames received on this PU." ::= { sdlcPuStatsEntry 15 } sdlcPuOutDISCFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DISC frames transmitted on this PU." ::= { sdlcPuStatsEntry 16 } sdlcPuInDMFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DM frames received on this PU." ::= { sdlcPuStatsEntry 17 } sdlcPuOutDMFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of DM frames transmitted on this PU." ::= { sdlcPuStatsEntry 18 } sdlcPuInUAFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of UA frames received on this PU." ::= { sdlcPuStatsEntry 19 } sdlcPuOutUAFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of UA frames transmitted on this PU." ::= { sdlcPuStatsEntry 20 } sdlcPuInFRMRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FRMR frames received on this PU." ::= { sdlcPuStatsEntry 21 } sdlcPuOutFRMRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of FRMR frames transmitted on this PU." ::= { sdlcPuStatsEntry 22 } sdlcPuInRDFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RD frames received on this PU." ::= { sdlcPuStatsEntry 23 } sdlcPuOutRDFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of RD frames transmitted on this PU." ::= { sdlcPuStatsEntry 24 } sdlcPuInUIFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of UI frames received on this PU." ::= { sdlcPuStatsEntry 25 } sdlcPuOutUIFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of UI frames transmitted on this PU." ::= { sdlcPuStatsEntry 26 } sdlcPuReTxIFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of re-transmitted I frames on this PU." ::= { sdlcPuStatsEntry 27 } sdlcPuPollResponseTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PU Poll Response timeouts for this PU." ::= { sdlcPuStatsEntry 28 } -- -- The Bisync PU Group -- -- The Bisync PU Configuration Table: -- bisyncPuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF BisyncPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Bisync CU entries." ::= { puBisyncGroup 1 } bisyncPuConfigEntry OBJECT-TYPE SYNTAX BisyncPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { bisyncPuConfigLineIndex, bisyncPuConfigAddress } ::= { bisyncPuConfigTable 1 } BisyncPuConfigEntry ::= SEQUENCE { bisyncPuConfigLineIndex INTEGER, bisyncPuConfigAddress OCTET STRING, bisyncPuNAUName DisplayString, bisyncPuInitialState INTEGER, bisyncPuXID OCTET STRING, bisyncPuTargetHostType INTEGER, bisyncPuMaxData INTEGER, bisyncPuConnectionID OCTET STRING, bisyncPuConnectType INTEGER } bisyncPuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is configured on." ::= { bisyncPuConfigEntry 1 } bisyncPuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { bisyncPuConfigEntry 2 } bisyncPuNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { bisyncPuConfigEntry 3 } bisyncPuInitialState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the PU. If configured for 'in-service', then the Bisync PU will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the SDLC PU must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'in-service'." ::= { bisyncPuConfigEntry 4 } bisyncPuXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. The unit will insert the data configured in the LLC XID sent to the host during the LLC connection process on behalf of the CU. For bisync control units, this field is required as bisync cannot solicit an XID. For incoming LLC connections on Sync Research products this field is parsed to route the connection to the proper PU. The default value for this field is all zeroes." ::= { bisyncPuConfigEntry 5 } bisyncPuTargetHostType OBJECT-TYPE SYNTAX INTEGER { sna-host-type(1), bisync-host-type(2), ice-host-type(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The Target Host type. This field specifies the target host type for TBSC and is applicable to BSC-to-SNA conversion only. This parameter defaults to a value of 2." ::= { bisyncPuConfigEntry 6 } bisyncPuMaxData OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the SNA frame size which is the sum of SNA data and SNA header. This value must match the MAXData configured for SNA host and is applicable to BSC-to-SNA conversion only. The default value is 521. The valid range is 265, 521, 777, 1033, 1289." ::= { bisyncPuConfigEntry 7 } bisyncPuConnectionID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes." ::= { bisyncPuConfigEntry 8 } bisyncPuConnectType OBJECT-TYPE SYNTAX INTEGER { answer(1), originate(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Bisync PU Connection type." ::= { bisyncPuConfigEntry 9 } -- -- The Bisync PU Statistics Table: -- -- The Bisync PU Statisctics table contains statistical information on -- the lines' configured PUs. bisyncPuStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF BisyncPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU statistics entries." ::= { puBisyncGroup 2 } bisyncPuStatsEntry OBJECT-TYPE SYNTAX BisyncPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { bisyncPuStatsLineIndex, bisyncPuStatsAddress } ::= { bisyncPuStatsTable 1 } BisyncPuStatsEntry ::= SEQUENCE { bisyncPuStatsLineIndex INTEGER, bisyncPuStatsAddress OCTET STRING, bisyncPuInTransactions Counter, bisyncPuOutTransactions Counter, bisyncPuSlowPolls Counter, bisyncPuPolls Counter } bisyncPuStatsLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is configured on." ::= { bisyncPuStatsEntry 1 } bisyncPuStatsAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { bisyncPuStatsEntry 2 } bisyncPuInTransactions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PU Poll Response timeouts for this PU." ::= { bisyncPuStatsEntry 3 } bisyncPuOutTransactions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PU Poll Response timeouts for this PU." ::= { bisyncPuStatsEntry 4 } bisyncPuSlowPolls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PU slow polls for this PU." ::= { bisyncPuStatsEntry 5 } bisyncPuPolls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PU Polls for this PU." ::= { bisyncPuStatsEntry 6 } -- -- The Mapping PU Group -- -- ******** -- This whole group is obsolete and is replaced by puRemoteGroup -- ******** -- -- The Mapping PU Configuration Table contains mapping information -- on the lines' configured PUs. mappingPuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF MappingPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This Table is obsolete. A list of PU mapping entries." ::= { puMappingGroup 1 } mappingPuConfigEntry OBJECT-TYPE SYNTAX MappingPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This field is obsolete. This entry contains information about a given mapping PU. Each entry includes MAC/SAP information for a source PU and a similar information for the partner (mapped) PU. Depending upon whether the PU is LAN-attached, SDLC-attached or Frame Relay-attached, one or more fields may not apply. Some fields, for example, mappingPuNAU, mappingPuXID, mappingPuConnectID are common to both end points. The entry is indexed by the port number and the PU number." INDEX { mappingPuConfigLineIndex, mappingPuConfigAddress } ::= { mappingPuConfigTable 1 } MappingPuConfigEntry ::= SEQUENCE { mappingPuConfigLineIndex INTEGER, mappingPuConfigAddress OCTET STRING, mappingPuSourceSAP OCTET STRING, mappingPuDestinationSAP OCTET STRING, mappingPuDestinationMAC PhysAddress, mappingPuPartnerConfigLineIndex INTEGER, mappingPuPartnerConfigAddress OCTET STRING, mappingPuPartnerSourceSAP OCTET STRING, mappingPuPartnerDestSAP OCTET STRING, mappingPuPartnerDestMAC PhysAddress, mappingPuNAU DisplayString, mappingPuConnectID OCTET STRING, mappingPuXID OCTET STRING, mappingPuDirectDLCI OCTET STRING, mappingPuLastClearCode OCTET STRING, mappingPuConnAttemptCnt Counter, mappingPuPartnerLastClearCode OCTET STRING, mappingPuPartnerConnAttemptCnt Counter } mappingPuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The port number for which PU is associated with. Port number 99 is a special value which is used to indicate NetView PU." ::= { mappingPuConfigEntry 1 } mappingPuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The PU address in the range of 0x01 to 0xfe." ::= { mappingPuConfigEntry 2 } mappingPuSourceSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The LLC source SAP value for this PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync products are configured to always call the same remote Token-Ring Host or Gateway for all connections configured. This means that all the Destination SAP (usually set to 4) and Destination MAC addresses are the same, so the Source SAP field must be set to a unique value in order to uniquely identify the LLC connection to the Host. (SNA does not allow multiplexing of PUs on one LLC connection. Each PU must have its own LLC Type 2 connection.) This field must be set to a range between 04 and E8 hexadecimal and it must be evenly divisible by 4 (802.2 LLC rules for user assigned SAPs). This field is not applicable in all cases, if not it returns a dummy value. This parameter defaults to a value of 4." ::= { mappingPuConfigEntry 3 } mappingPuDestinationSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The LLC Destination SAP value for this PU. For SNA typically the destination is almost always SAP 4. However both Host Front Ends (e.g. 3745) or Gateways (e.g. 3174) allow SAPs to be configured for any value betwee 0x04 and 0xEC as long as the SAP ID is a user assignable individual SAP ID (any value evenly divisable by 4). This field is not applicable to all cases. If not it returns a dummy value. This parameter defaults to a value of 4." ::= { mappingPuConfigEntry 4 } mappingPuDestinationMAC OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The LAN Destination MAC address used in the LLC Type 2 connection for this PU. The Token-Ring format for this field is a 6 octet (48 bit) field represented in IEEE 802.5 format where the first bit transmitted is the most significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses are between 000000000001 and 7FFFFFFFFFFF (an address of all zeroes is not supported). The Ethernet format for this field is a 6 octet (48 bit) field represented in IEEE 802.3 format where the first bit transmitted is the least significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses must start with the least significant bit equal to 0. In other words, the first two digits must be in the set of 0x00, 0x02, 0x04, ... 0xFE (an address of all 12 digits equal to zeroes is not supported). This field is not applicable to all cases. If not it returns a dummy value." ::= { mappingPuConfigEntry 5 } mappingPuPartnerConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The port number for the partner PU associated with source PU. Port number 99 is a special value which is used to indicate NetView PU." ::= { mappingPuConfigEntry 6 } mappingPuPartnerConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The PU address of the partner PU in the range of 0x01 to 0xfe." ::= { mappingPuConfigEntry 7 } mappingPuPartnerSourceSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The LLC source SAP value for a partner PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync products are configured to always call the same remote Token-Ring Host or Gateway for all connections configured. This means that all the Destination SAP (usually set to 4) and Destination MAC addresses are the same, so the Source SAP field must be set to a unique value in order to uniquely identify the LLC connection to the Host. (SNA does not allow multiplexing of PUs on one LLC connection. Each PU must have its own LLC Type 2 connection.) This field must be set to a range between 04 and E8 hexadecimal and it must be evenly divisible by 4 (802.2 LLC rules for user assigned SAPs). This field is not applicable in all cases, if not it returns a dummy value. This parameter defaults to a value of 4." ::= { mappingPuConfigEntry 8 } mappingPuPartnerDestSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The LLC Destination SAP value for the partner PU. For SNA typically the destination is almost always SAP 4. However both Host Front Ends (e.g. 3745) or Gateways (e.g. 3174) allow SAPs to be configured for any value betwee 0x04 and 0xEC as long as the SAP ID is a user assignable individual SAP ID (any value evenly divisable by 4). This field is not applicable to all cases. It returns a dummy value. This parameter defaults to a value of 4." ::= { mappingPuConfigEntry 9 } mappingPuPartnerDestMAC OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The LAN Destination MAC address used in the LLC Type 2 connection for the partner PU. The Token-Ring format for this field is a 6 octet (48 bit) field represented in IEEE 802.5 format where the first bit transmitted is the most significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses are between 000000000001 and 7FFFFFFFFFFF (an address of all zeroes is not supported). The Ethernet format for this field is a 6 octet (48 bit) field represented in IEEE 802.3 format where the first bit transmitted is the least significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses must start with the least significant bit equal to 0. In other words, the first two digits must be in the set of 0x00, 0x02, 0x04, ... 0xFE (an address of all 12 digits equal to zeroes is not supported). This field is not applicable to all cases. If not it returns a dummy value." ::= { mappingPuConfigEntry 10 } mappingPuNAU OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The NAU Name. The NAU name is same for both the source PU and the partner PU. It represents one physical PU in a network." ::= { mappingPuConfigEntry 11 } mappingPuConnectID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The connection ID. This must match a connection ID of an access line PU or another mapping PU Connection ID. The connnection ID is 0 if there is no mapping." ::= { mappingPuConfigEntry 12 } mappingPuXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. For incoming LLC connections on Sync Research products this field is parsed to route the connection to the proper PU. The XID is same for both the source PU and the partner PU. It represents one physical PU in a network. The default value for this field is all zeroes." ::= { mappingPuConfigEntry 13 } mappingPuDirectDLCI OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The Frame Relay DLCI used in the LLC Type 2 connection for this PU. The Frame Relay format for this field is a 2 octet (16 bit) field represented in BCD format. A valid DLCI would be from 0001 to 1023 (0000 is reserved for AnnexD management. 1023 is reserved for LMI mangement.). This value is applicable to Frame Relay-attached PU only. The field corresponds to a source port or a partner port depending upon whether the source PU is a Frame Relay-attached PU or the partner PU is Frame Relay-attached PU. For Frame Relay-attached PU if this value is not configured, 0 is returned." ::= { mappingPuConfigEntry 14 } mappingPuLastClearCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. A two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed connection attempt (a.k.a. call attempt) or active connection (a.k.a. session) for this PU. For LLC type 2 connections the first octet (cause) is always 0. The second octet (diagnostic) indicates the reason for the last connection failure. The second octet is set to 0 when a sucessful call has been placed, or if no call has ever been placed, or the clear is initiated by the partner for which mappingPuPartnerLastClearCode has the clear code. If the second octet is non-zero then it indicates the reason for the connection attempt failure. See User's Guide for more information" ::= { mappingPuConfigEntry 15 } mappingPuConnAttemptCnt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The number of connection attempts performed for this PU. This count is set to zero at startup, and after every loss of an estabished session." ::= { mappingPuConfigEntry 16 } mappingPuPartnerLastClearCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. A two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed connection attempt (a.k.a. call attempt) or active connection (a.k.a. session) for the partner PU . For LLC type 2 connections the first octet (cause) is always 0. The second octet (diagnostic) indicates the reason for the last connection failure. The second octet is set to 0 when a sucessful call has been placed, or if no call has ever been placed, or the clear is initiated by the partner for which mappingPuLastClearCode has the clear code. If the second octet is non-zero then it indicates the reason for the connection attempt failure. See User's Guide for information" ::= { mappingPuConfigEntry 17 } mappingPuPartnerConnAttemptCnt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This field is obsolete. The number of connection attempts performed for the partner PU. This count is set to zero at startup, and after every loss of an estabished session." ::= { mappingPuConfigEntry 18 } -- -- The Remote PU Group -- -- The Mapping PU Configuration Table contains mapping information -- on the lines' configured PUs. remotePuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF RemotePuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU mapping entries." ::= { puRemoteGroup 1 } remotePuConfigEntry OBJECT-TYPE SYNTAX RemotePuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given mapping PU. Each entry includes MAC/SAP information for a source PU and a similar information for the partner (mapped) PU. Depending upon whether the PU is LAN-attached, SDLC-attached or Frame Relay-attached, one or more fields may not apply. Some fields, for example, mappingPuNAU, mappingPuXID, mappingPuConnectID are common to both end points. The entry is indexed by the port number and the PU number." INDEX { accessPuConfigLineIndex, accessPuConfigAddress } ::= { remotePuConfigTable 1 } RemotePuConfigEntry ::= SEQUENCE { accessPuConfigLineIndex INTEGER, accessPuConfigAddress OCTET STRING, remotePuConfigLineIndex INTEGER, remotePuConfigAddress OCTET STRING, remotePuSourceSAP OCTET STRING, remotePuDestinationSAP OCTET STRING, remotePuMAC PhysAddress, remotePuPrimaryDLCI INTEGER, remotePuParallelDLCI INTEGER, remotePuAlternateDLCI INTEGER, remotePuAlternateMACAddress PhysAddress, remotePuTransmitPriority INTEGER, remotePuBroadcastAllDLCI INTEGER, remotePuLocalDTE OCTET STRING, remotePuRemoteDTE OCTET STRING } accessPuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is associated with. Port number 99 is a special value which is used to indicate NetView PU." ::= { remotePuConfigEntry 1 } accessPuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x01 to 0xfe. If the accessPuConfigLineIndex indicates a NetView PU then 01 is used to indicate the primary NetView PU and 02 is used to indicate alternate NetView PU." ::= { remotePuConfigEntry 2 } remotePuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which an access PU, LCU or XCU is associated with." ::= { remotePuConfigEntry 3 } remotePuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The access PU, LCU or XCU address in the range of 0x01 to 0xfe." ::= { remotePuConfigEntry 4 } remotePuSourceSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The LLC source SAP value for this PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync products are configured to always call the same remote Token-Ring Host or Gateway for all connections configured. This means that all the Destination SAP (usually set to 4) and Destination MAC addresses are the same, so the Source SAP field must be set to a unique value in order to uniquely identify the LLC connection to the Host. (SNA does not allow multiplexing of PUs on one LLC connection. Each PU must have its own LLC Type 2 connection.) This field must be set to a range between 04 and E8 hexadecimal and it must be evenly divisible by 4 (802.2 LLC rules for user assigned SAPs). This field is not applicable in all cases, if not it returns a dummy value. This parameter defaults to a value of 4." ::= { remotePuConfigEntry 5 } remotePuDestinationSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The LLC Destination SAP value for this PU. For SNA typically the destination is almost always SAP 4. However both Host Front Ends (e.g. 3745) or Gateways (e.g. 3174) allow SAPs to be configured for any value betwee 0x04 and 0xEC as long as the SAP ID is a user assignable individual SAP ID (any value evenly divisable by 4). This field is not applicable to all cases. If not it returns a dummy value. This parameter defaults to a value of 4." ::= { remotePuConfigEntry 6 } remotePuMAC OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The LAN Destination MAC address used in the LLC Type 2 connection for this PU. The Token-Ring format for this field is a 6 octet (48 bit) field represented in IEEE 802.5 format where the first bit transmitted is the most significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses are between 000000000001 and 7FFFFFFFFFFF (an address of all zeroes is not supported). The Ethernet format for this field is a 6 octet (48 bit) field represented in IEEE 802.3 format where the first bit transmitted is the least significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses must start with the least significant bit equal to 0. In other words, the first two digits must be in the set of 0x00, 0x02, 0x04, ... 0xFE (an address of all 12 digits equal to zeroes is not supported). This field is not applicable to all cases. If not it returns a dummy value." ::= { remotePuConfigEntry 7 } remotePuPrimaryDLCI OBJECT-TYPE SYNTAX INTEGER (0..1023) ACCESS read-only STATUS mandatory DESCRIPTION "The Frame Relay DLCI used in the LLC Type 2 connection for this PU. The Frame Relay format for this field is a 2 octet (16 bit) field represented in BCD format. A valid DLCI would be from 0001 to 1023 (0000 is reserved for AnnexD management. 1023 is reserved for LMI mangement.). This value is applicable to Frame Relay-attached PU only. The field corresponds to a source port or a partner port depending upon whether the source PU is a Frame Relay-attached PU or the partner PU is Frame Relay-attached PU. For Frame Relay-attached PU if this value is not configured, 0 is returned." ::= { remotePuConfigEntry 8 } remotePuParallelDLCI OBJECT-TYPE SYNTAX INTEGER (0..1023) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies a parallel DLCI indicating a virtual route in parallel to the primary DLCI path. The parallel virtual route allows for session resiliency." ::= { remotePuConfigEntry 9 } remotePuAlternateDLCI OBJECT-TYPE SYNTAX INTEGER (0..1023) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies an alternate DLCI indicating a virtual route to a disaster recovery site." ::= { remotePuConfigEntry 10 } remotePuAlternateMACAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "Specifies an alternate MAC address indicating a virtual route to a disaster recovery site." ::= { remotePuConfigEntry 11 } remotePuTransmitPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the transmission priority being URGENT, HIGH, MEDIUM or LOW for this PU." ::= { remotePuConfigEntry 12 } remotePuBroadcastAllDLCI OBJECT-TYPE SYNTAX INTEGER { yes (1), no (2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this field is set to YES, after all specified paths are determined as unavailable, the session request is broadcast to all DLCIs. IF the primary DLCI is set to 0, then this parameter is treated as YES regardless of its configured value." ::= { remotePuConfigEntry 13 } remotePuLocalDTE OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the local DTE address to match against any in-dial session for an access PU or LAN PU. For non X25 network type, this field is set to 0" ::= { remotePuConfigEntry 14 } remotePuRemoteDTE OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the remote DTE address that the X25 SVC connection uses for this access PU or LAN PU." ::= { remotePuConfigEntry 15 } -- -- The Async PU Configuration Group -- -- The PU Configuration Group contains information on the lines' -- configured PUs. asyncPuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AsyncPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU entries." ::= { puAsyncGroup 1 } asyncPuConfigEntry OBJECT-TYPE SYNTAX AsyncPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { asyncPuConfigLineIndex, asyncPuConfigAddress } ::= { asyncPuConfigTable 1 } AsyncPuConfigEntry ::= SEQUENCE { asyncPuConfigLineIndex INTEGER, asyncPuConfigAddress OCTET STRING, asyncPuNAUName DisplayString, asyncPuInitialState INTEGER, asyncPuXID OCTET STRING, asyncPuConnectionID OCTET STRING, asyncPuConnectType INTEGER, asyncPuDeviceRangeLow OCTET STRING, asyncPuDeviceRangeHigh OCTET STRING } asyncPuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the line (CU)is configured (first level)." ::= { asyncPuConfigEntry 1 } asyncPuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { asyncPuConfigEntry 2 } asyncPuNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { asyncPuConfigEntry 3 } asyncPuInitialState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the PU. If configured for 'in-service', then the async PU will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the async PU must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'in-service'." ::= { asyncPuConfigEntry 4 } asyncPuXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. If the field is configured to 0 then the unit will solicit the XID from the downstream PU and send the XID data received from async to the XID data sent for the LLC connection process. If not sent to 0, then the unit will insert the data configured in the LLC sent to the host during the LLC connection process on behalf of the CU. For incoming LLC connections on Sync Research products this field is parsed to route the connection to the proper PU. The default value for this field is all zeroes (solicit XID from PU)." ::= { asyncPuConfigEntry 5 } asyncPuConnectionID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes." ::= { asyncPuConfigEntry 6 } asyncPuConnectType OBJECT-TYPE SYNTAX INTEGER { answer(1), originate(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Async PU Connection type." ::= { asyncPuConfigEntry 7 } asyncPuDeviceRangeLow OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The device range number low specifies the low number of a range one or more device addresses for which the data to be routed via the connection information (i.e. Connection ID and XID) contained in an individual CU record. This number must be less than or equal to the deviec range number high. This field is in the range of 0x00 to 0xff." ::= { asyncPuConfigEntry 8 } asyncPuDeviceRangeHigh OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The device range number high specifies the high number of a range of one or more device addresses for which the data to be routed via the connection information (i.e. Connection ID and XID) contained in an individual CU record. This number must be greater than or equal to the device range number low. This field is in the range of 0x00 to 0xff." ::= { asyncPuConfigEntry 9 } -- -- The Async PU Statistics Table: -- -- The Async PU Statisctics table contains statistical information on the -- lines' configured PUs. asyncPuStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AsyncPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU statistics entries." ::= { puAsyncGroup 2 } asyncPuStatsEntry OBJECT-TYPE SYNTAX AsyncPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { asyncPuStatsLineIndex, asyncPuStatsAddress } ::= { asyncPuStatsTable 1 } AsyncPuStatsEntry ::= SEQUENCE { asyncPuStatsLineIndex INTEGER, asyncPuStatsAddress OCTET STRING, asyncPuInChars Counter, asyncPuOutChars Counter, asyncPuInMessages Counter, asyncPuOutMessages Counter } asyncPuStatsLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is configured on." ::= { asyncPuStatsEntry 1 } asyncPuStatsAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { asyncPuStatsEntry 2 } asyncPuInChars OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of characters received for this PU." ::= { asyncPuStatsEntry 3 } asyncPuOutChars OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of characters transmitted to this PU." ::= { asyncPuStatsEntry 4 } asyncPuInMessages OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of messages received from this PU." ::= { asyncPuStatsEntry 5 } asyncPuOutMessages OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of messages transmitted to this PU." ::= { asyncPuStatsEntry 6 } -- -- The LAN PU Configuration Group -- -- The PU Configuration Group contains information on the lan' -- configured PUs. lanPuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF LanPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU entries." ::= { puLanGroup 1 } lanPuConfigEntry OBJECT-TYPE SYNTAX LanPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { lanPuConfigLineIndex, lanPuConfigAddress } ::= { lanPuConfigTable 1 } LanPuConfigEntry ::= SEQUENCE { lanPuConfigLineIndex INTEGER, lanPuConfigAddress OCTET STRING, lanPuNAUName DisplayString, lanPuXID OCTET STRING, lanPuConnectionID OCTET STRING, lanPuSourceSAP OCTET STRING, lanPuDestinationSAP OCTET STRING, lanPuMAC PhysAddress, lanPuAlternateMACAddress PhysAddress } lanPuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the line (CU)is configured (first level)." ::= { lanPuConfigEntry 1 } lanPuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xff." ::= { lanPuConfigEntry 2 } lanPuNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { lanPuConfigEntry 3 } lanPuXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. If the field is configured to 0 then the unit will solicit the XID from the downstream PU and send the XID data received from async to the XID data sent for the LLC connection process. If not sent to 0, then the unit will insert the data configured in the LLC sent to the host during the LLC connection process on behalf of the CU. For incoming LLC connections on Sync Research products this field is parsed to route the connection to the proper PU." ::= { lanPuConfigEntry 4 } lanPuConnectionID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes." ::= { lanPuConfigEntry 5 } lanPuSourceSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The LLC source SAP value for this PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync products are configured to always call the same remote Token-Ring Host or Gateway for all connections configured. This means that all the Destination SAP (usually set to 4) and Destination MAC addresses are the same, so the Source SAP field must be set to a unique value in order to uniquely identify the LLC connection to the Host. (SNA does not allow multiplexing of PUs on one LLC connection. Each PU must have its own LLC Type 2 connection.) This field must be set to a range between 04 and E8 hexadecimal and it must be evenly divisible by 4 (802.2 LLC rules for user assigned SAPs). This field is not applicable in all cases, if not it returns a dummy value. This parameter defaults to a value of 4." ::= { lanPuConfigEntry 6 } lanPuDestinationSAP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The LLC Destination SAP value for this PU. For SNA typically the destination is almost always SAP 4. However both Host Front Ends (e.g. 3745) or Gateways (e.g. 3174) allow SAPs to be configured for any value betwee 0x04 and 0xEC as long as the SAP ID is a user assignable individual SAP ID (any value evenly divisable by 4). This field is not applicable to all cases. If not it returns a dummy value. This parameter defaults to a value of 4." ::= { lanPuConfigEntry 7 } lanPuMAC OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The LAN Destination MAC address used in the LLC Type 2 connection for this PU. The Token-Ring format for this field is a 6 octet (48 bit) field represented in IEEE 802.5 format where the first bit transmitted is the most significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses are between 000000000001 and 7FFFFFFFFFFF (an address of all zeroes is not supported). The Ethernet format for this field is a 6 octet (48 bit) field represented in IEEE 802.3 format where the first bit transmitted is the least significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses must start with the least significant bit equal to 0. In other words, the first two digits must be in the set of 0x00, 0x02, 0x04, ... 0xFE (an address of all 12 digits equal to zeroes is not supported). This field is not applicable to all cases. If not it returns a dummy value." ::= { lanPuConfigEntry 8 } lanPuAlternateMACAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the second destination MAC address for a disaster recovery site." ::= { lanPuConfigEntry 9 } -- -- The PU Configuration Group -- -- The PU Configuration Group contains information on the lines' -- configured PUs. x25PuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF X25PuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU entries." ::= { puX25Group 1 } x25PuConfigEntry OBJECT-TYPE SYNTAX X25PuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { x25PuConfigLineIndex, x25PuConfigAddress } ::= { x25PuConfigTable 1 } X25PuConfigEntry ::= SEQUENCE { x25PuConfigLineIndex INTEGER, x25PuConfigAddress OCTET STRING, x25PuNAUName DisplayString, x25PuConnectionID OCTET STRING, x25PuXID OCTET STRING, x25PuSolicitXID INTEGER, x25PuSourceAddress OCTET STRING, x25PuRemoteDTEAddress OCTET STRING } x25PuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is configured on." ::= { x25PuConfigEntry 1 } x25PuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { x25PuConfigEntry 2 } x25PuNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { x25PuConfigEntry 3 } x25PuConnectionID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes." ::= { x25PuConfigEntry 4 } x25PuXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The XID value for this PU. The XID set the CU identification used to establish and negotiate PU-application sessions. If the PU cannot respond to an XID request from the Host, you can configure the Sync unit to supply the XID for the PU by enabling Solicit XID. The default value for this field is all zeroes (solicit XID from PU)." ::= { x25PuConfigEntry 5 } x25PuSolicitXID OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter enables or disables soliciting an XID exchange between the Host and DSPU. This determines whether the Sync unit will solicit an XID to the X.25-attached PU. This parameter defaults to a value of 'Yes'." ::= { x25PuConfigEntry 6 } x25PuSourceAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The paramter specifies the Source Address. This is used to match DTE address." ::= { x25PuConfigEntry 7 } x25PuRemoteDTEAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The paramter specifies a DTE address on the connection's remote end enabling the Host to initiate a session. If you would rather have the X.25 PU initiate the session(indial), do not specify a DTE Address. If the LAN is the incoming session path for this LCU, you do not need to configure this parameter if you are using XIDs to set up a connection. The default value for this field is NONE." ::= { x25PuConfigEntry 8 } -- -- The PU Configuration Group -- -- The PU Configuration Group contains information on the lines' -- configured PUs. alcPuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AlcPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU entries." ::= { puAlcGroup 1 } alcPuConfigEntry OBJECT-TYPE SYNTAX AlcPuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { alcPuConfigAddress } ::= { alcPuConfigTable 1 } AlcPuConfigEntry ::= SEQUENCE { alcPuConfigLineIndex INTEGER, alcPuConfigAddress OCTET STRING, alcPuNAUName DisplayString, alcPuCSS INTEGER, alcPuConnectionID OCTET STRING, alcPuXID OCTET STRING, alcPuConnectType INTEGER, alcPuLineNumber OCTET STRING, alcPuMaximumFastPoll INTEGER, alcPuMinimumFastPoll INTEGER, alcPuMaximumSlowPollInterval INTEGER, alcPuMinimumSlowPollInterval INTEGER, alcPuResponseTimeout INTEGER, alcPuUserData OCTET STRING, alcSourceDTEAddress OCTET STRING, alcDestinationDTEAddress OCTET STRING } alcPuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is configured on." ::= { alcPuConfigEntry 1 } alcPuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x01 to 0x3C (both inclusive) with addresses 0x0d, 0x1D and 0x20 being invalid addresses. The default value is 0x01" ::= { alcPuConfigEntry 2 } alcPuNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { alcPuConfigEntry 3 } alcPuCSS OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the CU. The Interchange (CU) should be enabled or not when the configuration is activated. The range is 'in-service' or 'out-of-service'. The default value is 'inservice'." ::= { alcPuConfigEntry 4 } alcPuConnectionID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes." ::= { alcPuConfigEntry 5 } alcPuXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The XID value for this PU. The XID defines an identifier call ID BLOCK and ID NUM, which is used in session establishment using LLC2. The default value for this field is all zeroes (solicit XID from PU)." ::= { alcPuConfigEntry 6 } alcPuConnectType OBJECT-TYPE SYNTAX INTEGER { answer(1), originate(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Alc PU Connection type." ::= { alcPuConfigEntry 7 } alcPuLineNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The parmater defines a host reference to as line number. The range of this parameter is 0x01 to 0xFF(both inclusive). This parameter must match the Host configuration table. The default value is 0x01" ::= { alcPuConfigEntry 8 } alcPuMaximumFastPoll OBJECT-TYPE SYNTAX INTEGER(1..99) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the maximum time the unit will wait before it polls a device. Typicall the data transfer has priority over polling algorithm. This parameter ensures that polling is not suspended in favor of data transmittal for a prolonged period of time. Range of this parameter is from 1 through 99 in seconds. The default value is 1." ::= { alcPuConfigEntry 9 } alcPuMinimumFastPoll OBJECT-TYPE SYNTAX INTEGER(1..65500) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the minimum time the unit will wait before it polls a device. This parameter ensures that the devices are not polled at a very high rate (allowing for a pause). Range of this parameter is from 1 through 65500 in 100ths of a second. The default value is 300." ::= { alcPuConfigEntry 10 } alcPuMaximumSlowPollInterval OBJECT-TYPE SYNTAX INTEGER(1..99) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the maximum time an inactive device is left out of poll list before it is put back in the poll list. Range of this parameter is from 1 through 99 in seconds. The default value is 1." ::= { alcPuConfigEntry 11 } alcPuMinimumSlowPollInterval OBJECT-TYPE SYNTAX INTEGER(1..990) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the minimum time an inactive device is left out of poll list before it is put back in the poll list. Range of this parameter is from 1 through 990 in 10ths of a second. The default value is 10." ::= { alcPuConfigEntry 12 } alcPuResponseTimeout OBJECT-TYPE SYNTAX INTEGER(1..99) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines the duration that a unit will wait for a response from a device. Range of this parameter is from 1 through 99 in 10ths of a second. The default value is 5." ::= { alcPuConfigEntry 13 } alcPuUserData OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) ACCESS read-only STATUS mandatory DESCRIPTION "The paramter specifies the user data upto sixteen hexadecimal bytes for AX.25 protocol." ::= { alcPuConfigEntry 14 } alcSourceDTEAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the DTE address this port will use to access the Alc network." ::= { alcPuConfigEntry 15 } alcDestinationDTEAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the DTE address this port will use to access the Alc network." ::= { alcPuConfigEntry 16 } -- -- The Alc PU Statistics Table: -- -- The Alc PU Statisctics table contains statistical information on the -- lines' configured PUs. alcPuStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AlcPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of PU statistics entries." ::= { puAlcGroup 2 } alcPuStatsEntry OBJECT-TYPE SYNTAX AlcPuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { alcPuStatsLineIndex, alcPuStatsAddress } ::= { alcPuStatsTable 1 } AlcPuStatsEntry ::= SEQUENCE { alcPuStatsLineIndex INTEGER, alcPuStatsAddress OCTET STRING, alcPuPolls Counter, alcPuDeviceFaults Counter, alcPuBytesRcv Counter, alcPuBytesXmit Counter, alcPuSegRcv Counter, alcPuSegXmit Counter } alcPuStatsLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is configured on." ::= { alcPuStatsEntry 1 } alcPuStatsAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { alcPuStatsEntry 2 } alcPuPolls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Polls." ::= { alcPuStatsEntry 3 } alcPuDeviceFaults OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Device Faults." ::= { alcPuStatsEntry 4 } alcPuBytesRcv OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes Received to this PU." ::= { alcPuStatsEntry 5 } alcPuBytesXmit OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bytes Transmitted for this PU." ::= { alcPuStatsEntry 6 } alcPuSegRcv OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Segments Received to this PU." ::= { alcPuStatsEntry 7 } alcPuSegXmit OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Segments Transmitted for this PU." ::= { alcPuStatsEntry 8 } -- -- The Bisync RJE PU Group -- -- The Bisync RJE PU Configuration Table: -- bisyncrjePuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF BisyncrjePuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Bisync CU entries." ::= { puBisyncRjeGroup 1 } bisyncrjePuConfigEntry OBJECT-TYPE SYNTAX BisyncrjePuConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given PU. The entry is indexed by the port number and the PU number." INDEX { bisyncrjePuConfigLineIndex, bisyncrjePuConfigAddress } ::= { bisyncrjePuConfigTable 1 } BisyncrjePuConfigEntry ::= SEQUENCE { bisyncrjePuConfigLineIndex INTEGER, bisyncrjePuConfigAddress OCTET STRING, bisyncrjePuNAUName DisplayString, bisyncrjePuInitialState INTEGER, bisyncrjePuConnectionID OCTET STRING, bisyncrjePuXID OCTET STRING, bisyncrjePuConnectType INTEGER } bisyncrjePuConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which PU is configured on." ::= { bisyncrjePuConfigEntry 1 } bisyncrjePuConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The PU address in the range of 0x00 to 0xfe." ::= { bisyncrjePuConfigEntry 2 } bisyncrjePuNAUName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters)." ::= { bisyncrjePuConfigEntry 3 } bisyncrjePuInitialState OBJECT-TYPE SYNTAX INTEGER { in-service(1), out-of-service(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The initial state of the PU. If configured for 'in-service', then the Bisync RJE PU will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the SDLC PU must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'in-service'." ::= { bisyncrjePuConfigEntry 4 } bisyncrjePuConnectionID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes." ::= { bisyncrjePuConfigEntry 5 } bisyncrjePuXID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "The XID value for this PU. The default value for this field is all zeroes." ::= { bisyncrjePuConfigEntry 6 } bisyncrjePuConnectType OBJECT-TYPE SYNTAX INTEGER { answer(1), originate(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Bisync RJE PU Connection type." ::= { bisyncrjePuConfigEntry 7 } -- -- The Device Control Group -- deviceControlTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for controlling devices and obtaining information." ::= { deviceControlGroup 1 } deviceControlEntry OBJECT-TYPE SYNTAX DeviceControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of device information for a particular device." INDEX { deviceControlIndex, deviceControlCUIndex, deviceControlAddress } ::= { deviceControlTable 1 } DeviceControlEntry ::= SEQUENCE { deviceControlIndex INTEGER, deviceControlCUIndex INTEGER, deviceControlAddress OCTET STRING, deviceStatus INTEGER, deviceControlFailureCode OCTET STRING } deviceControlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number that uniquely identifies this device." ::= { deviceControlEntry 1 } deviceControlCUIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CU index for this device." ::= { deviceControlEntry 2 } deviceControlAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The device address." ::= { deviceControlEntry 3 } deviceStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), failed(3), restart(4), enable-all(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the device. To change (write) status of a device, enable, disable, restart or enable all may be set. Valid Return (read) status are enable(d), disable(d), or failed (d). Commands: An enable command will attempt to bring up the device. An enable all command will perform the same function as enable, since there are no sub elements on a device. A disable command will disable the device. Status: Enable(d) indicates the device is enabled and running. Disable(d) indicates the device has been disabled. Failed (d) indicates the device is enabled and not Running." ::= { deviceControlEntry 4 } deviceControlFailureCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "This entry contains the failure codes if the associated device is in the failed state." ::= { deviceControlEntry 5 } -- -- The Device Configuration Group -- -- The Device Configuration Group contains information on the lines' -- configured Devices. -- -- The Device Configuration Table deviceConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of device entries." ::= { deviceBSCGroup 1 } deviceConfigEntry OBJECT-TYPE SYNTAX DeviceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given device. The entry is indexed by the port number, CU index, and device." INDEX { deviceConfigLineIndex, deviceConfigCUIndex, deviceConfigAddress } ::= { deviceConfigTable 1 } DeviceConfigEntry ::= SEQUENCE { deviceConfigLineIndex INTEGER, deviceConfigCUIndex INTEGER, deviceConfigAddress OCTET STRING, deviceConfigType INTEGER } deviceConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the line (CU)is configured (line level)." ::= { deviceConfigEntry 1 } deviceConfigCUIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CU index which this device is configured on (CU level)." ::= { deviceConfigEntry 2 } deviceConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The device address in the legal range of BSC poll addresses (device level)." ::= { deviceConfigEntry 3 } deviceConfigType OBJECT-TYPE SYNTAX INTEGER { crt (1), printer (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The device type. The default value is crt." ::= { deviceConfigEntry 4 } -- -- The Device Statistics Table -- deviceStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of device statistics information." ::= { deviceBSCGroup 2 } deviceStatsEntry OBJECT-TYPE SYNTAX DeviceStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given device. The entry is indexed by the port number, CU index, and device." INDEX { bscDeviceLineIndex, bscDeviceCUIndex, bscDeviceAddress } ::= { deviceStatsTable 1 } DeviceStatsEntry ::= SEQUENCE { bscDeviceLineIndex INTEGER, bscDeviceCUIndex INTEGER, bscDeviceAddress OCTET STRING, bscDeviceInTransactions Counter, bscDeviceOutTransactions Counter, bscDeviceSumCount Counter, bscDeviceResponseDelaySum Counter, bscDeviceResponseDelaySqSum Counter } bscDeviceLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the line (CU)is configured (line level)." ::= { deviceStatsEntry 1 } bscDeviceCUIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CU index which this device is configured on (CU level)." ::= { deviceStatsEntry 2 } bscDeviceAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The device address in the legal range of BSC poll addresses (device level)." ::= { deviceStatsEntry 3 } bscDeviceInTransactions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of device receiving transactions." ::= { deviceStatsEntry 4 } bscDeviceOutTransactions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of device transmitting transactions." ::= { deviceStatsEntry 5 } bscDeviceSumCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The device sum count." ::= { deviceStatsEntry 6 } bscDeviceResponseDelaySum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The device sum count." ::= { deviceStatsEntry 7 } bscDeviceResponseDelaySqSum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The device sum count." ::= { deviceStatsEntry 8 } -- -- The Device Configuration Group -- -- The Device Configuration Group contains information on the lines' -- configured Devices. -- -- The Device Configuration Table alcdeviceConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AlcdeviceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of device entries." ::= { deviceALCGroup 1 } alcdeviceConfigEntry OBJECT-TYPE SYNTAX AlcdeviceConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a given device. The entry is indexed by the port number, CU index, and device." INDEX { alcdeviceConfigLineIndex, alcdeviceConfigCUIndex, deviceConfigAddress } ::= { alcdeviceConfigTable 1 } AlcdeviceConfigEntry ::= SEQUENCE { alcdeviceConfigLineIndex INTEGER, alcdeviceConfigCUIndex INTEGER, alcdeviceConfigAddress OCTET STRING, alcdeviceConfigType INTEGER } alcdeviceConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number for which the line (CU)is configured (line level)." ::= { alcdeviceConfigEntry 1 } alcdeviceConfigCUIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CU index which this device is configured on (CU level)." ::= { alcdeviceConfigEntry 2 } alcdeviceConfigAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) ACCESS read-only STATUS mandatory DESCRIPTION "The device address in the legal range of ALC poll addresses (device level). The range is 0x01 to 0x3c with 0x20 being invalid address. The default value is 0x01." ::= { alcdeviceConfigEntry 3 } alcdeviceConfigType OBJECT-TYPE SYNTAX INTEGER { crt (1), printer (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The device type. The default value is printer." ::= { alcdeviceConfigEntry 4 } -- -- The T7 Configuration Group -- Contains the current operational configuration -- t7ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF T7ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for T7 protocol configuration parameters." ::= { t7ConfigGroup 1 } t7ConfigEntry OBJECT-TYPE SYNTAX T7ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of T7 protocol information for a particular port." INDEX { t7ConfigIndex } ::= { t7ConfigTable 1 } T7ConfigEntry ::= SEQUENCE { t7ConfigIndex INTEGER, t7ProtocolEnabled INTEGER, t7PortSpeed INTEGER, t7StopBits INTEGER, t7PortParity INTEGER, t7DataBits INTEGER, t7IdleTimer INTEGER, t7PortTxFrameGap INTEGER, t7RxForwardingCount INTEGER, t7PortIPAddress IpAddress, t7UDPPortNumber INTEGER } t7ConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number that uniquely identifies this T7 port." ::= { t7ConfigEntry 1 } t7ProtocolEnabled OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This flag indicates if T7 protocol is enabled on this unit. If No, the following T7 variables will have no effect. The default value for this field is 'No'" ::= { t7ConfigEntry 2 } t7PortSpeed OBJECT-TYPE SYNTAX INTEGER { speed75(75), speed150(150), speed300(300), speed600(600), speed1200(1200), speed2400(2400), speed4800(4800), speed9600(9600), speed19200(19200) } ACCESS read-only STATUS mandatory DESCRIPTION "The speed of the T7 port expressed in bits per second. The default speed is 75 bits per second" ::= { t7ConfigEntry 3 } t7StopBits OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of stop bits generated for T7 port transmit characters (received characters may have any number of bits regardless of the configuration). The default value is 2" ::= { t7ConfigEntry 4 } t7PortParity OBJECT-TYPE SYNTAX INTEGER { odd(1), even(2), none(3) } ACCESS read-only STATUS mandatory DESCRIPTION "T7 port parity type generated for transmit characters and checked for receive characters. If ODD or EVEN, then if a character is received with invalid parity, it is discarded and the message once completely received is also discarded (i.e. not forwarded to the network). If NONE, then no parity bit is expected within the character or generated to the line. The default value is EVEN." ::= { t7ConfigEntry 5 } t7DataBits OBJECT-TYPE SYNTAX INTEGER (5..8) ACCESS read-only STATUS mandatory DESCRIPTION "T7 port number of data bit (not including the parity bit). The default value is 7" ::= { t7ConfigEntry 6 } t7IdleTimer OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "The T7 Idle timer is amount of time (in milliseconds) used to determine when a complete message has been received from the line. If configured as 0, then this timer is disabled and the message will be sent to the network only when the RX forwarding count is reached. If configured greater than 0, then the timer must be configured for a time longer than the time it takes to receive one character, otherwise the timer will not function properly. The default value is 200" ::= { t7ConfigEntry 7 } t7PortTxFrameGap OBJECT-TYPE SYNTAX INTEGER (0..5000) ACCESS read-only STATUS mandatory DESCRIPTION "The T7 port TX frame gap is analogous to the idle timer, but is used to separate messages received from the network by gaps in time so that the Async device can distinguish between multiple messages. If configured as 0, then this function is disabled and if messages are received while transmitting a current message, the the two messages from the network will be sent out with no gap between them. If configured greater than 0, then a gap of the specified number of milliseconds will be inserted. The default value is 200" ::= { t7ConfigEntry 8 } t7RxForwardingCount OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "The T7 port receive forwarding count is used to forward messages when a configured number of characters is received from the Async line. This must be configured to greater than or equal to the maximum message length for a given protocol. The default value is 256" ::= { t7ConfigEntry 9 } t7PortIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The T7 port IP address is used to configure the remote IP address in which to communicate with." ::= { t7ConfigEntry 10 } t7UDPPortNumber OBJECT-TYPE SYNTAX INTEGER (1..1000) ACCESS read-only STATUS mandatory DESCRIPTION "The T7 port UDP port number address is used to configure the local and remot UDP port number (i.e. socket) address in which to communicate with. The default value is 600" ::= { t7ConfigEntry 11 } -- -- The T7 Statistics Group -- Contains the current T7 Statistics -- t7StatsTable OBJECT-TYPE SYNTAX SEQUENCE OF T7StatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of T7 protocol statistics information." ::= { t7StatsGroup 1 } t7StatsEntry OBJECT-TYPE SYNTAX T7StatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a T7 port. The entry is indexed by the port number, CU index, and device." INDEX { t7StatsIndex } ::= { t7StatsTable 1 } T7StatsEntry ::= SEQUENCE { t7StatsIndex INTEGER, t7InOctets Counter, t7OutOctets Counter, t7InMessages Counter, t7OutMessages Counter, t7InMsgDiscarded Counter, t7OutMsgDiscarded Counter, t7XmtFailures Counter, t7RcvMsgForwarded Counter, t7RcvMsgErrors Counter, t7RcvCharsDiscarded Counter, t7RcvParityErrors Counter, t7RcvFramingErrors Counter, t7RcvFifoOverruns Counter, t7RcvCharsOverruns Counter, t7RcvBreakConditions Counter } t7StatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number that uniquely identifies this T7 port." ::= { t7StatsEntry 1 } t7InOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received." ::= { t7StatsEntry 2 } t7OutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes sent." ::= { t7StatsEntry 3 } t7InMessages OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of messages received." ::= { t7StatsEntry 4 } t7OutMessages OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of messages sent." ::= { t7StatsEntry 5 } t7InMsgDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received messages discarded." ::= { t7StatsEntry 6 } t7OutMsgDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of sent messages discarded." ::= { t7StatsEntry 7 } t7XmtFailures OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of failures in transmission." ::= { t7StatsEntry 8 } t7RcvMsgForwarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received messages forwarded." ::= { t7StatsEntry 9 } t7RcvMsgErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of errors detected in receiving messages." ::= { t7StatsEntry 10 } t7RcvCharsDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received characters discarded." ::= { t7StatsEntry 11 } t7RcvParityErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of parity errors detected." ::= { t7StatsEntry 12 } t7RcvFramingErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of errors detected in receiving frames." ::= { t7StatsEntry 13 } t7RcvFifoOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number FIFO receive overruns detected." ::= { t7StatsEntry 14 } t7RcvCharsOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of character receive overruns detected." ::= { t7StatsEntry 15 } t7RcvBreakConditions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receive break conditions." ::= { t7StatsEntry 16 } -- -- The Slip Configuration Group -- Contains the current operational configuration -- slipConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SlipConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table for Slip protocol configuration parameters." ::= { slipConfigGroup 1 } slipConfigEntry OBJECT-TYPE SYNTAX SlipConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry consisting of Slip protocol information for a particular port." INDEX { slipConfigIndex } ::= { slipConfigTable 1 } SlipConfigEntry ::= SEQUENCE { slipConfigIndex INTEGER, slipProtocolEnabled INTEGER, slipPortSpeed INTEGER, slipStopBits INTEGER, slipIdleTimer INTEGER, slipPortIPAddress IpAddress, slipUsage INTEGER, slipNetworkMask IpAddress, slipDefaultGateway IpAddress, slipEnableRIP INTEGER } slipConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number that uniquely identifies this Slip port." ::= { slipConfigEntry 1 } slipProtocolEnabled OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This flag indicates if COM2 port is enabled or disabled for usage for SLIP. The default value for this field is 'Yes'" ::= { slipConfigEntry 2 } slipPortSpeed OBJECT-TYPE SYNTAX INTEGER { speed75(75), speed150(150), speed300(300), speed600(600), speed1200(1200), speed2400(2400), speed4800(4800), speed9600(9600), speed19200(19200) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter determines the COM2 port speed for the SLIP connection to the modem. The default speed is 9600 bits per second" ::= { slipConfigEntry 3 } slipStopBits OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the number of transmit Stop Bits used on the SLIP connection to the modem. The range of this parameter is 1 or 2 bits. The default value is 1" ::= { slipConfigEntry 4 } slipIdleTimer OBJECT-TYPE SYNTAX INTEGER (0..5000) ACCESS read-only STATUS mandatory DESCRIPTION "The Slip Idle timer is amount of time (in milliseconds) used to determine the end of frame. The idel timer is started every time a character is received. The range of this parameter is from 0 to 5000 milliseconds. A valuse of zero implies the parameter is not used. The default value is 200" ::= { slipConfigEntry 5 } slipPortIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Slip port IP address. The default valus is 0.0.0.0." ::= { slipConfigEntry 6 } slipUsage OBJECT-TYPE SYNTAX INTEGER { modem-management(1), ipend-node(2), ip-routing(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines whether SLIP protocol is used to manage locally attached modem or is it used for IP end node function or IP forwarding function. The range of this parameter is MODEM MANAGEMENT, IPEND NODE, IP ROUTING. The default value is Modem Management" ::= { slipConfigEntry 7 } slipNetworkMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines IP sub-netmask for this parameter. The default valus is 0.0.0.0." ::= { slipConfigEntry 8 } slipDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines IP default gateway. The default valus is 0.0.0.0." ::= { slipConfigEntry 9 } slipEnableRIP OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter defines whether RIP packets should be sent on this interface or not. Range is yes or no. The default valus is 'no'." ::= { slipConfigEntry 10 } -- -- The Slip Statistics Group -- Contains the current Slip Statistics -- slipStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF SlipStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Slip protocol statistics information." ::= { slipStatsGroup 1 } slipStatsEntry OBJECT-TYPE SYNTAX SlipStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contains information about a slip Com port." INDEX { slipStatsIndex } ::= { slipStatsTable 1 } SlipStatsEntry ::= SEQUENCE { slipStatsIndex INTEGER, slipInChrs Counter, slipOutChrs Counter, slipInMessages Counter, slipOutMessages Counter, slipInMsgDiscarded Counter, slipOutMsgDiscarded Counter, slipXmtFailures Counter, slipRcvMsgForwarded Counter, slipRcvMsgErrors Counter, slipRcvCharsDiscarded Counter, slipRcvParityErrors Counter, slipRcvFramingErrors Counter, slipRcvFifoOverruns Counter, slipRcvCharsOverruns Counter, slipRcvBreakConditions Counter } slipStatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number that uniquely identifies this Slip com port." ::= { slipStatsEntry 1 } slipInChrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Characters received." ::= { slipStatsEntry 2 } slipOutChrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of characters sent." ::= { slipStatsEntry 3 } slipInMessages OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of messages received." ::= { slipStatsEntry 4 } slipOutMessages OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of messages sent." ::= { slipStatsEntry 5 } slipInMsgDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received messages discarded." ::= { slipStatsEntry 6 } slipOutMsgDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of sent messages discarded." ::= { slipStatsEntry 7 } slipXmtFailures OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of failures in transmission." ::= { slipStatsEntry 8 } slipRcvMsgForwarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received messages forwarded." ::= { slipStatsEntry 9 } slipRcvMsgErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of errors detected in receiving messages." ::= { slipStatsEntry 10 } slipRcvCharsDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received characters discarded." ::= { slipStatsEntry 11 } slipRcvParityErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of parity errors detected." ::= { slipStatsEntry 12 } slipRcvFramingErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of errors detected in receiving frames." ::= { slipStatsEntry 13 } slipRcvFifoOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number FIFO receive overruns detected." ::= { slipStatsEntry 14 } slipRcvCharsOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of character receive overruns detected." ::= { slipStatsEntry 15 } slipRcvBreakConditions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receive break conditions." ::= { slipStatsEntry 16 } -- -- Sync Research TRAP MIB -- -- -- This MIB module uses the extended TRAP-TYPE macro as -- defined in RFC 1215. configChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, configId } DESCRIPTION "This trap indicates that the configuration of the unit has been changed." ::= 800 configError TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, lastInstallErrCode } DESCRIPTION "This trap indicates that the activation of configuration of the unit has resulted in an error. New configuration has not been successfully activated." ::= 801 dumpExists TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, dumpFileName } DESCRIPTION "This trap indicates that a memory core dump exists." ::= 802 dumpArchived TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber } DESCRIPTION "This trap indicates that the memory dump file has been archived." ::= 803 lineStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, lineStatus, lineControlFailureCode, linePhysicalIndex, lineCableType } DESCRIPTION "This trap indicates that the indicated Line or Port has changed state. It has either been enabled, failed or disabled." ::= 804 lanStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, lanStatus, lanControlFailureCode } DESCRIPTION "This trap indicates that the indicated LAN Port has changed state. It has either been enabled, failed or disabled." ::= 805 lineQuality TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, lineQualityFrameCount, lineQualityCRCErrors, lineQualityAborts, linePhysicalIndex } DESCRIPTION "This trap indicates that the line quality is changed. If the lineQualityAborts is greater than 5 or lineQualityCRCErrors is greater that 5 then it indicates a poor line quality, otherwise it indicates a change from a poor to good line quality." ::= 806 puStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puStatus, puControlFailureCode, linePhysicalIndex, puControlPUAddress } DESCRIPTION "This trap indicates that the indicated PU has changed state. It has either been enabled, failed or disabled." ::= 807 puConnectionStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puConnectionStatus, puLastClearCode } DESCRIPTION "Note this trap is obsolete. This trap indicates that the indicated PU has changed connection state. Its connection has either been established, disconnected, or rejected." ::= 808 netviewConnectionStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, netviewConnectionStatus, netviewLastClearCode } DESCRIPTION "Note this trap is obsolete. This trap indicates that the NetView PU has changed connection state. Its connection has either been established, disconnected, or rejected." ::= 809 netviewAltConnectionStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, netviewAltConnectionStatus, netviewAltLastClearCode } DESCRIPTION "Note this trap is obsolete. This trap indicates that the Alternate NetView PU has changed connection state. Its connection has either been established, disconnected, or rejected." ::= 810 puConnectionStatusUp TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, linePhysicalIndex, puControlPUAddress } DESCRIPTION "This trap is obsolete. This trap indicates that the indicated PU has changed connection state. Its connection had been established." ::= 811 puConnectionStatusDown TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, linePhysicalIndex, puControlPUAddress, puLastClearCode } DESCRIPTION "This trap is obsolete. This trap indicates that the indicated PU has changed connection state. Its connection has been disconnected. If the indicated PU is not in session, the trap is generated only if the clear code is different from the puLastClearCode." ::= 812 netviewConnectionStatusUp TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber } DESCRIPTION "This trap is obsolete. This trap indicates that the indicated NetView PU has changed connection state. Its connection has been established." ::= 813 netviewConnectionStatusDown TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, netviewLastClearCode } DESCRIPTION "This trap is obsolete. This trap indicates that the indicated NetView PU has changed connection state. Its connection had been disconnected. If the indicated PU is not in session, the trap is generated only if the clear code is different from the netviewLastClearCode." ::= 814 netviewAltConnectionStatusUp TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber } DESCRIPTION "This trap is obsolete. This trap indicates that the indicated Alternate NetView PU has changed connection state. Its connection has been established." ::= 815 netviewAltConnectionStatusDown TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, netviewAltLastClearCode } DESCRIPTION "This trap is obsolete. This trap indicates that the indicated Alternate NetView PU has changed connection state. Its connection had been disconnected. If the indicated PU is not in session, the trap is generated only if the clear code is different from the netviewAltLastClearCode." ::= 816 sessSwitchedToPrimaryDLCI TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puControlLineIndex, puControlPUAddress, puCurrentDlci, puIsDynamic} DESCRIPTION "This trap indicates that a session switch has occured from a Parallel DLCI to Primary DLCI." ::= 817 sessSwitchedToParallelDLCI TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puControlLineIndex, puControlPUAddress, puCurrentDlci, puIsDynamic} DESCRIPTION "This trap indicates that a session switch has occured from the Primary DLCI to the Parallel DLCI." ::= 818 sessUpOnPrimaryDLCI TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puControlLineIndex, puControlPUAddress, puCurrentDlci, puCurrentMAC, puIsDynamic} DESCRIPTION "This indicates that a PU session is established on a primary DLCI. This TRAP is generated for Frame Nodes only. For Conversion Node sessUpOnPrimaryMAC or sessUpOnAlternatMAC will be used instead. For NetView the puControlLineIndex is set to 99, and the puControlPUAddress is set to 01 for primary PU and 02 for the alternate NetView PU." ::= 819 sessUpOnParallelDLCI TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puControlLineIndex, puControlPUAddress, puCurrentDlci, puCurrentMAC, puIsDynamic} DESCRIPTION "This indicates that a PU session is established on a parallel DLCI. This TRAP is generated for Frame Nodes only. For Conversion Node sessUpOnPrimaryMAC or sessUpOnAlternatMAC will be used instead. For NetView the puControlLineIndex is set to 99, and the puControlPUAddress is set to 01 for primary PU and 02 for the alternate NetView PU." ::= 820 sessUpOnAlternateDLCI TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puControlLineIndex, puControlPUAddress, puCurrentDlci, puCurrentMAC, puIsDynamic} DESCRIPTION "This indicates that a PU session is established on an alternate DLCI. This TRAP is generated for Frame Nodes only. For Conversion Node sessUpOnPrimaryMAC or sessUpOnAlternatMAC will be used instead. For NetView the puControlLineIndex is set to 99, and the puControlPUAddress is set to 01 for primary PU and 02 for the alternate NetView PU." ::= 821 sessUpOnPrimaryMAC TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puControlLineIndex, puControlPUAddress, puCurrentDlci, puCurrentMAC, linePhysicalType, puIsDynamic} DESCRIPTION "This indicates that a PU session is established on a non-explicit (dynamic, or broadcast) DLCI to the primary destination MAC. For Conversion Node, puCurrentDlci is set to 0. For NetView the puControlLineIndex is set to 99, and the puControlPUAddress is set to 01 for primary PU and 02 for the alternate NetView PU." ::= 822 sessUpOnAlternateMAC TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puControlLineIndex, puControlPUAddress, puCurrentDlci, puCurrentMAC, linePhysicalType, puIsDynamic} DESCRIPTION "This indicates that a PU session is established on a non-explicit (dynamic, or broadcast) DLCI to the alternate destination MAC, if configured. For Conversion Node, puCurrentDlci is set to 0. For NetView the puControlLineIndex is set to 99, and the puControlPUAddress is set to 01 for primary PU and 02 for the alternate NetView PU." ::= 823 sessDownOnPrimaryMAC TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puControlLineIndex, puControlPUAddress, puLastClearCode, puLastDlciCleared, puLastMACCleared, linePhysicalType, puIsDynamic} DESCRIPTION "This trap indicates that the session for the indicated PU associated with the primary destination MAC was cleared. If the indicated PU is not in session, the trap is generated only if the clear code is different from the puLastClearCode. For NetView the puControlLineIndex is set to 99, and the puControlPUAddress is set to 01 for primary PU and 02 for the alternate NetView PU. For Conversion Node, puLastDlicCleared is not applicable and is therefore set to 0" ::= 824 sessDownOnAlternateMAC TRAP-TYPE ENTERPRISE syncResearch VARIABLES {lastTrapSeqNumber, puControlLineIndex, puControlPUAddress, puLastClearCode, puLastDlciCleared, puLastMACCleared, linePhysicalType, puIsDynamic} DESCRIPTION "This trap indicates that the session for the indicated PU associated with the alternate destination MAC, if configured, was cleared. If the indicated PU is not in session, the trap is generated only if the clear code is different from the puLastClearCode. For NetView the puControlLineIndex is set to 99, and the puControlPUAddress is set to 01 for primary PU and 02 for the alternate NetView PU. For Conversion Node, puLastDlicCleared is not applicable and is therefore set to 0" ::= 825 lostUNI TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, linePhysicalIndex } DESCRIPTION "This trap indicates that the indicated Frame Relay Line or Port has lost its UNI connectivity to the Frame Relay network." ::= 826 restoredUNI TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, linePhysicalIndex } DESCRIPTION "This trap indicates that the indicated Frame Relay Line or Port has restored its UNI connectivity to the Frame Relay network." ::= 827 switchedToBackup TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, linePhysicalIndex } DESCRIPTION "This trap indicates that the indicated Frame Relay Line or Port has successfully switched to switched backup connection." ::= 828 switchedToDed TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, linePhysicalIndex } DESCRIPTION "This trap indicates that the indicated Frame Relay Line or Port has successfully switched to the dedicated Frame Relay connection to the network." ::= 829 dialConnStatusChanged TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, lineStatus, lineControlFailureCode, linePhysicalIndex } DESCRIPTION "This trap indicates that the indicated dial backup connection has changed state. It has either been connected or disconnected." ::= 830 sessUpOnSVC TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puControlLineIndex, puControlPUAddress, puCurrentSVC, puCurrentLocalDTE, puCurrentRemoteDTE, puIsDynamic} DESCRIPTION "This trap indicates that the session for the indicated PU or LAN PU associated with the remote DTE address was established." ::= 831 sessDownOnSVC TRAP-TYPE ENTERPRISE syncResearch VARIABLES { lastTrapSeqNumber, puControlLineIndex, puControlPUAddress, puLastClearCode, puLastSVCCleared, puLastLocalDTECleared, puLastRemoteDTECleared, puIsDynamic} DESCRIPTION "This trap indicates that the session for the indicated PU or LAN PU associated with the last remote DTE address was cleared. If the indicated PU/LAN PU is not in session, the trap is generated only if the clear code is different from the puLastClearCode." ::= 832 END