-- This file is corresponding to Release 6.3.1.100 from 2003/03/10 00:00:00 -- (C)opyright 1991-1999 BinTec Communications AG, All Rights Reserved -- $RCSfile: mibsysx8,v $ -- $Revision: 1.5 $ BIANCA-X8000-MIBSYS-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; org OBJECT IDENTIFIER ::= { iso 3 } dod OBJECT IDENTIFIER ::= { org 6 } internet OBJECT IDENTIFIER ::= { dod 1 } private OBJECT IDENTIFIER ::= { internet 4 } enterprises OBJECT IDENTIFIER ::= { private 1 } bintec OBJECT IDENTIFIER ::= { enterprises 272 } bibo OBJECT IDENTIFIER ::= { bintec 4 } sys OBJECT IDENTIFIER ::= { bibo 17 } x8 OBJECT IDENTIFIER ::= { sys 3 } sysX8Config OBJECT IDENTIFIER ::= { x8 1 } sysX8Traps OBJECT IDENTIFIER ::= { x8 2 } -- System Status and Configuration sysX8ConfigPowerSupply1State OBJECT-TYPE SYNTAX INTEGER { missing(1), off(2), running(3), fail(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable shows the state of the power supply." ::= { sysX8Config 1 } sysX8ConfigPowerSupply1Temp OBJECT-TYPE SYNTAX INTEGER (0..250) ACCESS read-only STATUS mandatory DESCRIPTION "This variable shows the actual power supply temperature in the unit Celsius." ::= { sysX8Config 2 } sysX8ConfigPowerSupply1TempAlarmThreshold OBJECT-TYPE SYNTAX INTEGER (0..250) ACCESS read-write STATUS mandatory DESCRIPTION "Power supply 1 temperature threshold." ::= { sysX8Config 3 } sysX8ConfigPowerSupply1TempAlarmTrap OBJECT-TYPE SYNTAX INTEGER { normal(1), critical(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds." ::= { sysX8Config 4 } sysX8ConfigPowerSupply2State OBJECT-TYPE SYNTAX INTEGER { missing(1), off(2), running(3), fail(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable show the the state of the power supply." ::= { sysX8Config 5 } sysX8ConfigPowerSupply2Temp OBJECT-TYPE SYNTAX INTEGER (0..250) ACCESS read-only STATUS mandatory DESCRIPTION "This variable shows the actual power supply temperature in the unit Celsius." ::= { sysX8Config 6 } sysX8ConfigPowerSupply2TempAlarmThreshold OBJECT-TYPE SYNTAX INTEGER (0..250) ACCESS read-write STATUS mandatory DESCRIPTION "Power supply 2 temperature threshold." ::= { sysX8Config 7 } sysX8ConfigPowerSupply2TempAlarmTrap OBJECT-TYPE SYNTAX INTEGER { normal(1), critical(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds." ::= { sysX8Config 8 } sysX8ConfigFanControl OBJECT-TYPE SYNTAX INTEGER { auto(1), high(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable defines automatic fan control. In mode 'auto' the fans are automatically adjusted depending on the current temperature. In mode 'high' all fans remain at maximum speed." ::= { sysX8Config 9 } sysX8ConfigFanVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable shows the firmware version of the fan unit." ::= { sysX8Config 10 } sysX8ConfigFan1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable shows the current turning speed." ::= { sysX8Config 11 } sysX8ConfigFan2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable shows the current turning speed." ::= { sysX8Config 12 } sysX8ConfigFan3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable shows the current turning speed." ::= { sysX8Config 13 } sysX8ConfigFan4 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable shows the current turning speed." ::= { sysX8Config 14 } --- --- System Status and Configuration Traps --- sysX8TrapPowerSupply1Missing TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply1State, sysX8ConfigPowerSupply1Temp, sysX8ConfigPowerSupply1TempAlarmTrap } DESCRIPTION "This trap signifies that the power supply 1 has been removed" ::= 1 sysX8TrapPowerSupply1PowerOff TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply1State, sysX8ConfigPowerSupply1Temp, sysX8ConfigPowerSupply1TempAlarmTrap } DESCRIPTION "This trap signifies that the power supply 1 has no power-good signal (no power input)" ::= 2 sysX8TrapPowerSupply1PowerFail TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply1State, sysX8ConfigPowerSupply1Temp, sysX8ConfigPowerSupply1TempAlarmTrap } DESCRIPTION "This trap signifies that the power supply 1 has been in the failure (bad DC output)" ::= 3 sysX8TrapPowerSupply1PowerGood TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply1State, sysX8ConfigPowerSupply1Temp, sysX8ConfigPowerSupply1TempAlarmTrap } DESCRIPTION "This trap signifies that the power supply 1 is running (supplying power)" ::= 4 sysX8TrapPowerSupply1TempCritical TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply1State, sysX8ConfigPowerSupply1Temp, sysX8ConfigPowerSupply1TempAlarmThreshold } DESCRIPTION "This trap signifies that the power supply 1 temperature raises above the critical alarm-threshold" ::= 5 sysX8TrapPowerSupply1TempOk TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply1State, sysX8ConfigPowerSupply1Temp, sysX8ConfigPowerSupply1TempAlarmThreshold } DESCRIPTION "A normal power supply 1 temperature has been restored." ::= 6 sysX8TrapPowerSupply2Missing TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply2State, sysX8ConfigPowerSupply2Temp, sysX8ConfigPowerSupply2TempAlarmThreshold } DESCRIPTION "This trap signifies that the power supply 2 has been removed" ::= 7 sysX8TrapPowerSupply2PowerOff TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply2State, sysX8ConfigPowerSupply2Temp, sysX8ConfigPowerSupply2TempAlarmThreshold } DESCRIPTION "This trap signifies that the power supply 2 has no power-good signal (no power input)" ::= 8 sysX8TrapPowerSupply2PowerFail TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply2State, sysX8ConfigPowerSupply2Temp, sysX8ConfigPowerSupply2TempAlarmThreshold } DESCRIPTION "This trap signifies that the power supply 2 has been in the failure (bad DC output)" ::= 9 sysX8TrapPowerSupply2PowerGood TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply2State, sysX8ConfigPowerSupply2Temp, sysX8ConfigPowerSupply2TempAlarmThreshold } DESCRIPTION "This trap signifies that the power supply 2 is running (supplying power)" ::= 10 sysX8TrapPowerSupply2TempCritical TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply2State, sysX8ConfigPowerSupply2Temp, sysX8ConfigPowerSupply2TempAlarmThreshold } DESCRIPTION "This trap signifies that the power supply 2 temperature raises above the critical alarm-threshold" ::= 11 sysX8TrapPowerSupply2TempOk TRAP-TYPE ENTERPRISE sysX8Traps VARIABLES { sysDescr, sysName, sysX8ConfigPowerSupply2State, sysX8ConfigPowerSupply2Temp, sysX8ConfigPowerSupply2TempAlarmThreshold } DESCRIPTION "A normal power supply 2 temperature has been restored." ::= 12 END