SNI-BUS-MIB DEFINITIONS ::= BEGIN -- -- (C) 1995 by Siemens Nixdorf Informationssysteme AG -- All rights reserved -- -- $Revision: 2 $ -- $Modtime: 27.05.97 9:35 $ -- IMPORTS OBJECT-TYPE FROM RFC-1212 mib-2, DisplayString FROM RFC1213-MIB TimeTicks, Counter, Gauge, enterprises FROM RFC1155-SMI; -- -- The Windows NT MIB compiler doesn't do IMPORTS. -- So, include these definitions here. NT defines "DisplayString" as -- OCTET STRING (SIZE(0..255)), in RFC1213 it has no explicit size. -- -- DisplayString ::= OCTET STRING -- enterprises OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) private(4) 1 } -- -- SNI Server Management MIB nodes sni OBJECT IDENTIFIER ::= { enterprises 231 } sniProductMibs OBJECT IDENTIFIER ::= { sni 2 } sniExtensions OBJECT IDENTIFIER ::= { sniProductMibs 10 } sniServerMgmt OBJECT IDENTIFIER ::= { sniExtensions 2 } sniInventory OBJECT IDENTIFIER ::= { sniServerMgmt 1 } sniCommon OBJECT IDENTIFIER ::= { sniServerMgmt 2 } sniBios OBJECT IDENTIFIER ::= { sniCommon 1 } sniEisa OBJECT IDENTIFIER ::= { sniCommon 2 } sniHd OBJECT IDENTIFIER ::= { sniCommon 3 } sniBus OBJECT IDENTIFIER ::= { sniCommon 4 } sniServerControl OBJECT IDENTIFIER ::= { sniCommon 5 } sniPcSpecific OBJECT IDENTIFIER ::= { sniServerMgmt 3 } sniScb OBJECT IDENTIFIER ::= { sniServerMgmt 4 } sniOsSpecific OBJECT IDENTIFIER ::= { sniServerMgmt 5 } sniNetware OBJECT IDENTIFIER ::= { sniOsSpecific 1 } sniWinNt OBJECT IDENTIFIER ::= { sniOsSpecific 2 } sniOs2 OBJECT IDENTIFIER ::= { sniOsSpecific 3 } sniUnix OBJECT IDENTIFIER ::= { sniOsSpecific 4 } sniOemComponents OBJECT IDENTIFIER ::= { sniServerMgmt 6 } sniOemDpt OBJECT IDENTIFIER ::= { sniOemComponents 1 } sniOemMylex OBJECT IDENTIFIER ::= { sniOemComponents 2 } sniMlxDiskArray OBJECT IDENTIFIER ::= { sniOemMylex 1 } sniSecurity OBJECT IDENTIFIER ::= { sniServerMgmt 7 } sniSmSecurity OBJECT IDENTIFIER ::= { sniSecurity 1 } sniServerView OBJECT IDENTIFIER ::= { sniServerMgmt 8 } sniTrapMib OBJECT IDENTIFIER ::= { sniExtensions 5 } ---------------------------------------------------------------------------------------- -- -- ServerView-MIB groups sniBusCommon OBJECT IDENTIFIER ::= { sniBus 1 } sniBusEisa OBJECT IDENTIFIER ::= { sniBus 2 } sniBusPci OBJECT IDENTIFIER ::= { sniBus 3 } sniBusResource OBJECT IDENTIFIER ::= { sniBus 4 } sniBusSummary OBJECT IDENTIFIER ::= { sniBus 5 } ---------------------------------------------------------------------------------------- -- -- GROUP: sniBusCommon -- Implementation of this group is mandatory sniEisaSlots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of eisa slots in the system. 0 if no EISA-Bus present." ::= { sniBusCommon 1 } sniIsaSlots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of isa slots in the system. 0 if no ISA-Bus present." ::= { sniBusCommon 2 } sniPciSlots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of pci slots in the system. 0 if no PCI-Bus present." ::= { sniBusCommon 3 } sniFunctionTable OBJECT-TYPE SYNTAX SEQUENCE OF SniFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all common data for all functions" ::= { sniBusCommon 4 } sniFunctionEntry OBJECT-TYPE SYNTAX SniFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniBusType, sniBusIndex, sniDeviceSlotNo, sniFunctionNo } ::= { sniFunctionTable 1 } SniFunctionEntry ::= SEQUENCE { sniBusType INTEGER, sniBusIndex INTEGER, sniDeviceSlotNo INTEGER, sniFunctionNo INTEGER, sniDeviceType INTEGER, sniDeviceTypeName DisplayString, sniDeviceName DisplayString, sniVendorName DisplayString, sniPhysicalSlotNo INTEGER, sniAdapterSpecificData OCTET STRING } sniBusType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isa(2), eisa(3), pci(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus" ::= { sniFunctionEntry 1 } sniBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniFunctionEntry 2 } sniDeviceSlotNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device- or Slot-number based on 0" ::= { sniFunctionEntry 3 } sniFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Functionnumber based on 1" ::= { sniFunctionEntry 4 } sniDeviceType OBJECT-TYPE SYNTAX INTEGER { unknown(0), diskcontroller(1), tapecontroller(2), cdromcontoller(3), wormcontroller (4), serialcontroller(5), networkcontroller(6), displaycontroller(7), parallelcontroller(8), pointercontoller(9), keyboardcontroller(10), audiocontroller(11), othercontroller(12), bridge-device(13), cpu(14) } ACCESS read-only STATUS mandatory DESCRIPTION "indicates the type of device" ::= { sniFunctionEntry 5 } sniDeviceTypeName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "type of device in readable form" ::= { sniFunctionEntry 6 } sniDeviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "name of device in readable form" ::= { sniFunctionEntry 7 } sniVendorName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "manufacturer of the device in readable form" ::= { sniFunctionEntry 8 } sniPhysicalSlotNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "indicates the physical slot the device resides in" ::= { sniFunctionEntry 9 } sniAdapterSpecificData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Specific data for this adapter. Currently the only information defined is the MAC address for lan adapters." ::= { sniFunctionEntry 10 } ---------------------------------------------------------------------------------------- -- -- GROUP: sniBusEisa -- Implementation of this group is optional sniEisaFunctionTable OBJECT-TYPE SYNTAX SEQUENCE OF SniEisaFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all eisa function entries" ::= { sniBusEisa 1 } sniEisaFunctionEntry OBJECT-TYPE SYNTAX SniEisaFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniEisaBusIndex, sniEisaSlotNo, sniEisaFunctionNo } ::= { sniEisaFunctionTable 1 } SniEisaFunctionEntry ::= SEQUENCE { sniEisaBusIndex INTEGER, sniEisaSlotNo INTEGER, sniEisaFunctionNo INTEGER, sniEisaSlotType INTEGER, sniEisaConfigurationComplete INTEGER, sniEisaType DisplayString, sniEisaValid INTEGER, sniEisaId DisplayString, sniEisaName DisplayString, sniEisaAgentType INTEGER } sniEisaBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniEisaFunctionEntry 1 } sniEisaSlotNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot number based on 0" ::= { sniEisaFunctionEntry 2 } sniEisaFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Eisa function number based on 1" ::= { sniEisaFunctionEntry 3 } sniEisaSlotType OBJECT-TYPE SYNTAX INTEGER { expansion-slot(1), embedded-slot(2), virtual-slot(3), reserved(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the slot" ::= { sniEisaFunctionEntry 4 } sniEisaConfigurationComplete OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "True if board is completely configured" ::= { sniEisaFunctionEntry 5 } sniEisaType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Type and subtype as ASCII string" ::= { sniEisaFunctionEntry 6 } sniEisaValid OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "True, if the slot contains a correctly configured eisa board." ::= { sniEisaFunctionEntry 7 } sniEisaId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The eisa id of the board." ::= { sniEisaFunctionEntry 8 } sniEisaName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Visual name of the board." ::= { sniEisaFunctionEntry 9 } sniEisaAgentType OBJECT-TYPE SYNTAX INTEGER { other(1), ethernet-adapter(2), token-ring-adapter(3), fddi-adapter(4), hd-adapter(5), extended-hd-adapter(6), cpu(7) } ACCESS read-only STATUS mandatory DESCRIPTION " " ::= { sniEisaFunctionEntry 10 } ---------------------------------------------------------------------------------------- -- -- GROUP: sniBusPci -- Implementation of this group is optional sniPciFunctionTable OBJECT-TYPE SYNTAX SEQUENCE OF SniPciFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all pci function entries" ::= { sniBusPci 1 } sniPciFunctionEntry OBJECT-TYPE SYNTAX SniPciFunctionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniPciBusIndex, sniPciDeviceNo, sniPciFunctionNo } ::= { sniPciFunctionTable 1 } SniPciFunctionEntry ::= SEQUENCE { sniPciBusIndex INTEGER, sniPciDeviceNo INTEGER, sniPciFunctionNo INTEGER, sniPciVendorId INTEGER, sniPciDeviceId INTEGER, sniPciRevisionId INTEGER, sniPciBaseClass INTEGER, sniPciSubClass INTEGER, sniPciProgIf INTEGER, sniPciBuiltInSelfTest INTEGER, sniPciInterruptPin INTEGER, sniPciInterruptLine INTEGER, sniPciSpecificData OCTET STRING, sniPciSecondaryBusIndex INTEGER, sniPciSecondaryBusType INTEGER } sniPciBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniPciFunctionEntry 1 } sniPciDeviceNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device number based on 0" ::= { sniPciFunctionEntry 2 } sniPciFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number based on 1" ::= { sniPciFunctionEntry 3 } sniPciVendorId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the manufacturer of the device. This must be a value allocated by the PCI SIG." ::= { sniPciFunctionEntry 4 } sniPciDeviceId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the particular device. This value is assigned by the manufacturer." ::= { sniPciFunctionEntry 5 } sniPciRevisionId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the revision level of the device described by sniPciDeviceId. This value is assigned by the manufacturer." ::= { sniPciFunctionEntry 6 } sniPciBaseClass OBJECT-TYPE SYNTAX INTEGER { old-type-device(0), mass-storage-controller(1), network-controller(2), display-controller(3), multimedia-device(4), memory-controller(5), bridge-device(6), simple-communication-controller(7), base-system-peripherals(8), input-devices(9), docking-stations(10), processors(11), serial-bus-controllers(12), unknown-device(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies type of the device, according to the PCI classification scheme." ::= { sniPciFunctionEntry 7 } sniPciSubClass OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the subtype, if any, of the device, according to the PCI classification scheme." ::= { sniPciFunctionEntry 8 } sniPciProgIf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the register-level programming interface, if any, for the device, according to the PCI classification scheme." ::= { sniPciFunctionEntry 9 } sniPciBuiltInSelfTest OBJECT-TYPE SYNTAX INTEGER { built-in(1), not-built-in(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if the device does support built-in self test." ::= { sniPciFunctionEntry 10 } sniPciInterruptPin OBJECT-TYPE SYNTAX INTEGER { not-implemented(0), inta(1), intb(2), intc(3), intd(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates which interrupt pin the PCI device uses." ::= { sniPciFunctionEntry 11 } sniPciInterruptLine OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the input of the system interrupt controller that the interrupt pin is connected to." ::= { sniPciFunctionEntry 12 } sniPciSpecificData OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This is device specific data found in the COMMON CONFIGURATION SPACE. This field is currently not used and therefor filled with zeros." ::= { sniPciFunctionEntry 13 } sniPciSecondaryBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Valid only for a bridge device. This is the index of the bridge's secondary bus (-1 = no bus index available; ignore this field)." ::= { sniPciFunctionEntry 14 } sniPciSecondaryBusType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Valid only for a bridge device. This is the type of the bridge's secondary bus. Following values are defined (according to PCI Local bus specification, Revision 2.1, values are incremented by 1): 00h: Unknown value; ignore this field 01h: Host bridge (bridge to CPU bus) 02h: ISA bridge 03h: EISA bridge 04h: MCA bridge 05h: PCI-to-PCI bridge 06h: PCMCIA bridge 07h: NuBus bridge 80h: Other bridge device" ::= { sniPciFunctionEntry 15 } ---------------------------------------------------------------------------------------- -- -- GROUP: sniBusResource -- Implementation of this group is mandatory sniMemoryTable OBJECT-TYPE SYNTAX SEQUENCE OF SniMemoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all memory entries" ::= { sniBusResource 1 } sniMemoryEntry OBJECT-TYPE SYNTAX SniMemoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniMemBusType, sniMemBusIndex, sniMemSlotDevice, sniMemFunctionNo, sniMemoryNo } ::= { sniMemoryTable 1 } SniMemoryEntry ::= SEQUENCE { sniMemBusType INTEGER, sniMemBusIndex INTEGER, sniMemSlotDevice INTEGER, sniMemFunctionNo INTEGER, sniMemoryNo INTEGER, sniBusSharedMemory INTEGER, sniBusMemoryStart INTEGER, sniBusMemoryLength INTEGER } sniMemBusType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isa(2), eisa(3), pci(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus" ::= { sniMemoryEntry 1 } sniMemBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniMemoryEntry 2 } sniMemSlotDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot or Device number based on 0" ::= { sniMemoryEntry 3 } sniMemFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number based on 1" ::= { sniMemoryEntry 4 } sniMemoryNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Memory number based on 1" ::= { sniMemoryEntry 5 } sniBusSharedMemory OBJECT-TYPE SYNTAX INTEGER { not-used(1), other(2), system(3), expanded(4), virtual(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of shared memory" ::= { sniMemoryEntry 6 } sniBusMemoryStart OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Start address of shared memory or 0 if not used" ::= { sniMemoryEntry 7 } sniBusMemoryLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of shared memory or 0 if not used" ::= { sniMemoryEntry 8 } sniInterruptTable OBJECT-TYPE SYNTAX SEQUENCE OF SniInterruptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all interrupt entries" ::= { sniBusResource 2 } sniInterruptEntry OBJECT-TYPE SYNTAX SniInterruptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniIntBusType, sniIntBusIndex, sniIntSlotDevice, sniIntFunctionNo, sniInterruptNo } ::= { sniInterruptTable 1 } SniInterruptEntry ::= SEQUENCE { sniIntBusType INTEGER, sniIntBusIndex INTEGER, sniIntSlotDevice INTEGER, sniIntFunctionNo INTEGER, sniInterruptNo INTEGER, sniBusInterruptUsed INTEGER, sniBusInterruptLevel INTEGER, sniBusInterruptShared INTEGER, sniBusInterruptNo INTEGER } sniIntBusType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isa(2), eisa(3), pci(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus" ::= { sniInterruptEntry 1 } sniIntBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniInterruptEntry 2 } sniIntSlotDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot or Device number based on 0" ::= { sniInterruptEntry 3 } sniIntFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number based on 1" ::= { sniInterruptEntry 4 } sniInterruptNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Interrupt number based on 1" ::= { sniInterruptEntry 5 } sniBusInterruptUsed OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "True if and only if not unknown and an interrupt is used" ::= { sniInterruptEntry 6 } sniBusInterruptLevel OBJECT-TYPE SYNTAX INTEGER { other(1), edge-triggered(2), level-triggered(3) } ACCESS read-only STATUS mandatory DESCRIPTION "interrupt level" ::= { sniInterruptEntry 7 } sniBusInterruptShared OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "True if and only if not unknown and an interrupt is shared" ::= { sniInterruptEntry 8 } sniBusInterruptNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "interrupt number used" ::= { sniInterruptEntry 9 } sniDMATable OBJECT-TYPE SYNTAX SEQUENCE OF SniDMAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all dma entries" ::= { sniBusResource 3 } sniDMAEntry OBJECT-TYPE SYNTAX SniDMAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniDMABusType, sniDMABusIndex, sniDMASlotDevice, sniDMAFunctionNo, sniDMANo } ::= { sniDMATable 1 } SniDMAEntry ::= SEQUENCE { sniDMABusType INTEGER, sniDMABusIndex INTEGER, sniDMASlotDevice INTEGER, sniDMAFunctionNo INTEGER, sniDMANo INTEGER, sniBusDMAChannel INTEGER, sniBusDMATiming INTEGER, sniBusDMATransferSize INTEGER } sniDMABusType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isa(2), eisa(3), pci(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus" ::= { sniDMAEntry 1 } sniDMABusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniDMAEntry 2 } sniDMASlotDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot or Device number based on 0" ::= { sniDMAEntry 3 } sniDMAFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number based on 1" ::= { sniDMAEntry 4 } sniDMANo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "DMA number based on 1" ::= { sniDMAEntry 5 } sniBusDMAChannel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "DMA channel " ::= { sniDMAEntry 6 } sniBusDMATiming OBJECT-TYPE SYNTAX INTEGER { other(1), default-timing(2), type-a-timing(3), type-b-timing(4) } ACCESS read-only STATUS mandatory DESCRIPTION "DMA timing" ::= { sniDMAEntry 7 } sniBusDMATransferSize OBJECT-TYPE SYNTAX INTEGER { other(1), bit-8(2), bit-16(3), bit-32(4) } ACCESS read-only STATUS mandatory DESCRIPTION "DMA transfer size" ::= { sniDMAEntry 8 } sniPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SniPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all port entries" ::= { sniBusResource 4 } sniPortEntry OBJECT-TYPE SYNTAX SniPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniPortBusType, sniPortBusIndex, sniPortSlotDevice, sniPortFunctionNo, sniPortNo } ::= { sniPortTable 1 } SniPortEntry ::= SEQUENCE { sniPortBusType INTEGER, sniPortBusIndex INTEGER, sniPortSlotDevice INTEGER, sniPortFunctionNo INTEGER, sniPortNo INTEGER, sniBusIOFirstPort INTEGER, sniBusIONoOfPorts INTEGER, sniBusIOPortShared INTEGER } sniPortBusType OBJECT-TYPE SYNTAX INTEGER { unknown(0), isa(2), eisa(3), pci(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus" ::= { sniPortEntry 1 } sniPortBusIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of the bus based on 1" ::= { sniPortEntry 2 } sniPortSlotDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot or Device number based on 0" ::= { sniPortEntry 3 } sniPortFunctionNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number based on 1" ::= { sniPortEntry 4 } sniPortNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port number based on 1" ::= { sniPortEntry 5 } sniBusIOFirstPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "First io port used" ::= { sniPortEntry 6 } sniBusIONoOfPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of io ports used" ::= { sniPortEntry 7 } sniBusIOPortShared OBJECT-TYPE SYNTAX INTEGER { true(1), false(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "True if io port is shared" ::= { sniPortEntry 8 } ---------------------------------------------------------------------------------------- -- -- GROUP: sniBusSummary -- Implementation of this group is optional sniBusComponentTable OBJECT-TYPE SYNTAX SEQUENCE OF SniBusComponents ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of all common data for all functions" ::= { sniBusSummary 1 } sniBusComponents OBJECT-TYPE SYNTAX SniBusComponents ACCESS not-accessible STATUS mandatory DESCRIPTION " " INDEX { sniBusCompBusType, sniBusCompBusNumber, sniBusCompDeviceNo } ::= { sniBusComponentTable 1 } SniBusComponents ::= SEQUENCE { sniBusCompBusType INTEGER, sniBusCompBusNumber INTEGER, sniBusCompDeviceNo INTEGER, sniBusCompSlotNo INTEGER, sniBusCompDeviceName DisplayString, sniBusCompDeviceType DisplayString, sniBusCompEisaPciId DisplayString } sniBusCompBusType OBJECT-TYPE SYNTAX INTEGER { unknown(1), isa(2), eisa(3), pci(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the bus (ISA, EISA, PCI)" ::= { sniBusComponents 1 } sniBusCompBusNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Bus number for the specified bus type (1..n)" ::= { sniBusComponents 2 } sniBusCompDeviceNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device number (PCI) or slot number (ISA, EISA)" ::= { sniBusComponents 3 } sniBusCompSlotNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Physical slot number (0..n), -1 if unknown" ::= { sniBusComponents 4 } sniBusCompDeviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Vendor and device name in readable form" ::= { sniBusComponents 5 } sniBusCompDeviceType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Device type in readable form" ::= { sniBusComponents 6 } sniBusCompEisaPciId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "EISA ID for EISA components, PCI vendor/device ID for PCI components (hexadecimal notation)" ::= { sniBusComponents 7 } END