ADTRAN-TSUOCdbu-MIB DEFINITIONS ::= BEGIN -- TITLE: Adtran DBU -- FILENAME: DBU.MIB -- PARTNUMBER: 1200.089L2 -- AUTHOR: Brian Prevallet -- DATE: 97/05/XX -- This MIB defines the DBU module IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 ifIndex FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 dsx1LineStatus FROM RFC1406-MIB adProdPhysAddress FROM ADTRAN-MIB; -- OBJECT IDENTIFIERS adtran OBJECT IDENTIFIER ::= { enterprises 664 } adProducts OBJECT IDENTIFIER ::= { adtran 1 } adMgmt OBJECT IDENTIFIER ::= { adtran 2 } ------------------------------------------------------------------------------ -- DBU ------------------------------------------------------------------------------ adTSUOCMg OBJECT IDENTIFIER ::= { adMgmt 1000 } adDBUConfig OBJECT IDENTIFIER ::= { adTSUOCMg 11 } adDBUCDBConfig OBJECT IDENTIFIER ::= { adDBUConfig 1 } adDBUTWConfig OBJECT IDENTIFIER ::= { adDBUConfig 2 } adTSUDBU OBJECT IDENTIFIER ::= { adProducts 80 } adTSUDBUtraps OBJECT IDENTIFIER ::= { adMgmt 80 } adTSUDBUconfig OBJECT IDENTIFIER ::= { adTSUDBUtraps 1 } -- CDB Items table based on ifindex adDBUCDBTable OBJECT-TYPE SYNTAX SEQUENCE OF ADDBUCDBEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DBU Slot table" ::= { adDBUCDBConfig 1 } adDBUCDBEntry OBJECT-TYPE SYNTAX ADDBUCDBEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DBU table." INDEX { adCDBifIndex } ::= { adDBUCDBTable 1 } ADDBUCDBEntry ::= SEQUENCE { adCDBifIndex INTEGER, adDBUBackup INTEGER, adDBUBackupDelay INTEGER, adDBURestoreDelay INTEGER, adDBUMode INTEGER, adDBUDsoRate INTEGER, adDBUDsoNumber INTEGER, adDBUWeekendBackup INTEGER, adDBUEnableHr INTEGER, adDBUDisableHr INTEGER, adDBULoopback INTEGER, adDBUForceBackup INTEGER, adDBUInterfaceTst INTEGER, adDBUDCERateAlarm INTEGER } adCDBifIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adDBUCDBEntry 1 } adDBUBackup OBJECT-TYPE SYNTAX INTEGER { enable (16), disable (17) } ACCESS read-write STATUS mandatory DESCRIPTION "Backup enabled or disabled option" ::= { adDBUCDBEntry 12 } adDBUBackupDelay OBJECT-TYPE SYNTAX INTEGER { sec1 (6), sec3 (7), sec10 (8), sec30 (9), min1 (10), min5 (11), min10 (12), never (13) } ACCESS read-write STATUS mandatory DESCRIPTION "DBU backup delay" ::= { adDBUCDBEntry 15 } adDBURestoreDelay OBJECT-TYPE SYNTAX INTEGER { sec1 (6), sec3 (7), sec10 (8), sec30 (9), min1 (10), min5 (11), min10 (12), never (13) } ACCESS read-write STATUS mandatory DESCRIPTION "DBU restore delay" ::= { adDBUCDBEntry 6 } adDBUMode OBJECT-TYPE SYNTAX INTEGER { answer (24), originate (25), orig-ans-any (26) } ACCESS read-write STATUS mandatory DESCRIPTION "DBU mode" ::= { adDBUCDBEntry 8 } adDBUDsoRate OBJECT-TYPE SYNTAX INTEGER { rate56k (18), rate64k (19) } ACCESS read-write STATUS mandatory DESCRIPTION "Rate per DSO to be backed up" ::= { adDBUCDBEntry 13 } adDBUDsoNumber OBJECT-TYPE SYNTAX INTEGER (0..24) ACCESS read-write STATUS mandatory DESCRIPTION "Number of DSO’s for backup" ::= { adDBUCDBEntry 2 } adDBUWeekendBackup OBJECT-TYPE SYNTAX INTEGER { enable (16), disable (17) } ACCESS read-write STATUS mandatory DESCRIPTION "Weekend backup option" ::= { adDBUCDBEntry 7 } adDBUEnableHr OBJECT-TYPE SYNTAX INTEGER (0..24) ACCESS read-write STATUS mandatory DESCRIPTION "Hour to enable backup" ::= { adDBUCDBEntry 10 } adDBUDisableHr OBJECT-TYPE SYNTAX INTEGER (0..24) ACCESS read-write STATUS mandatory DESCRIPTION "Hour to disable backup" ::= { adDBUCDBEntry 11 } adDBULoopback OBJECT-TYPE SYNTAX INTEGER { off (0), local (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Loopback (off or local)" ::= { adDBUCDBEntry 3 } adDBUForceBackup OBJECT-TYPE SYNTAX INTEGER { off (4), on (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Force backup option" ::= { adDBUCDBEntry 16 } adDBUInterfaceTst OBJECT-TYPE SYNTAX INTEGER { off (4), on (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Interface test" ::= { adDBUCDBEntry 9 } adDBUDCERateAlarm OBJECT-TYPE SYNTAX INTEGER { enable (16), diable (17) } ACCESS read-write STATUS mandatory DESCRIPTION " DCE rate alarm: Enable/Disable " ::= { adDBUCDBEntry 5 } -- this table is used to monitor DCE Data/CK adDBUDCEdata-ckTable OBJECT-TYPE SYNTAX SEQUENCE OF ADDBUDCEdata-ckEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Monitor the DCE Data/CK" ::= {adDBUTWConfig 51} adDBUDCEdata-ckEntry OBJECT-TYPE SYNTAX ADDBUDCEdata-ckEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the DCE Data/CK Table" INDEX { adTWdcIndex } ::= {adDBUDCEdata-ckTable 1} ADDBUDCEdata-ckEntry ::= SEQUENCE { adTWdcIndex INTEGER, adDBUDCEdata-ckData OCTET STRING } adTWdcIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adDBUDCEdata-ckEntry 1 } adDBUDCEdata-ckData OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "DCE Data/CK: txd, rxd, dcd, lck" ::= { adDBUDCEdata-ckEntry 16388 } --end of table -- this table is used for monitor status adDBUMonitorStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ADDBUMonitorStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Monitor Status for DBU" ::= {adDBUTWConfig 52} adDBUMonitorStatusEntry OBJECT-TYPE SYNTAX ADDBUMonitorStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the Monitor Status Table" INDEX { adTWmdIndex } ::= {adDBUMonitorStatusTable 1} ADDBUMonitorStatusEntry ::= SEQUENCE { adTWmdIndex INTEGER, adDBUMonitorStatus OCTET STRING } adTWmdIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adDBUMonitorStatusEntry 1 } adDBUMonitorStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "DBU Monitor Status State: RTS, CTS, DCD, DSR " ::= { adDBUMonitorStatusEntry 16388 } --end of monitor status table -- this table is used to monitor the data rate adDBUbckpRateTable OBJECT-TYPE SYNTAX SEQUENCE OF ADDBUbckpRateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "DBU back up rate table" ::= {adDBUTWConfig 53} adDBUbckpRateEntry OBJECT-TYPE SYNTAX ADDBUbckpRateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the backup rate Data Table" INDEX { adTWbrIndex } ::= {adDBUbckpRateTable 1} ADDBUbckpRateEntry ::= SEQUENCE { adTWbrIndex INTEGER, adDBUbckpRate INTEGER } adTWbrIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adDBUbckpRateEntry 1 } adDBUbckpRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Backup rate for the DBU" ::= { adDBUbckpRateEntry 1024 } --end of table -- this table is used check sync status adDBUSyncStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ADDBUSyncStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sync Status table" ::= {adDBUTWConfig 60} adDBUSyncStatusEntry OBJECT-TYPE SYNTAX ADDBUSyncStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the Sync Status Table" INDEX { adTWssIndex } ::= {adDBUSyncStatusTable 1} ADDBUSyncStatusEntry ::= SEQUENCE { adTWssIndex INTEGER, adDBUSyncStatus OCTET STRING } adTWssIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adDBUSyncStatusEntry 1 } adDBUSyncStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "Sync Status: Near Far" ::= { adDBUSyncStatusEntry 16386 } --end of table -- this table is used to determine if the card is in DBU adDBUBckpActiveTable OBJECT-TYPE SYNTAX SEQUENCE OF ADDBUBckpActiveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Backup activation status" ::= {adDBUTWConfig 58} adDBUBckpActiveEntry OBJECT-TYPE SYNTAX ADDBUBckpActiveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the backup activation Table" INDEX { adTWbaIndex } ::= {adDBUBckpActiveTable 1} ADDBUBckpActiveEntry ::= SEQUENCE { adTWbaIndex INTEGER, adDBUBckpActive INTEGER } adTWbaIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adDBUBckpActiveEntry 1 } adDBUBckpActive OBJECT-TYPE SYNTAX INTEGER { notCurrentlyBackingUp (1), currentlyBackingUp (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Determination of backup activation status" ::= { adDBUBckpActiveEntry 1024 } --end of table -------------------------------------------- -- TSU-XX0 DBU Enterprise Specific Traps -------------------------------------------- adTSUDBUPLLAlarm TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in PLL alarm condition" -- #TYPE "Alarm - DBU PLL" -- #SUMMARY "DBU 8001: PLL alarm condition. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8001 adTSUDBUZerosAlarm TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in Zero alarm condition" -- #TYPE "Alarm - DBU Zeros" -- #SUMMARY "DBU 8002: Zero alarm condition. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8002 adTSUDBUFIFOAlarm TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in FIFO alarm condition" -- #TYPE "Alarm - DBU FIFO" -- #SUMMARY "DBU 8003: FIFO alarm condition. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8003 adTSUDBURateMismatch TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in a rate mismatch condition" -- #TYPE "Alarm - Rate Mismatch" -- #SUMMARY "DBU 7901: Rate Mismatch condition. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8004 adTSUDBUDataPathError TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in data path error alarm condition" -- #TYPE "Alarm - Data Path Error" -- #SUMMARY "DBU 8005: Data Path Error. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8005 adTSUDBUBackupMapError TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card has a backup map error condition" -- #TYPE "Alarm - Backup Map Error" -- #SUMMARY "DBU 8006: Backup Map Error. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8006 adTSUDBUDCERateAlarm TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in DCE rate alarm condition" -- #TYPE "Alarm - DCE Rate Alarm" -- #SUMMARY "DBU 8007: DCE Path Error. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8007 adTSUDBU8s TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in 8s alarm condition" -- #TYPE "Alarm - 8s Alarm" -- #SUMMARY "DBU 8008: 8s Error. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8008 adTSUDBU9s TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in 9s alarm condition" -- #TYPE "Alarm - 9s Alarm" -- #SUMMARY "DBU 8009: 9s Error. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8009 adTSUDBU10s TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in 8s alarm condition" -- #TYPE "Alarm - 10s Alarm" -- #SUMMARY "DBU 8010: 10s Error. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8010 adTSUDBULost TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card has been removed from the chassis or that the card has failed. " -- #TYPE "Alarm - DBU Card Not Responding " -- #SUMMARY "DBU 8015: DBU card is not responding " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8015 adTSUDBUPLLAlarmClear TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is no longer in a PLL alarm condition" -- #TYPE "Alarm - DBU PLL Alarm Clear" -- #SUMMARY "DBU 8017: PLL alarm cleared. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8017 adTSUDBUZerosAlarmClear TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is no longer in a zeros alarm condition" -- #TYPE "Alarm - DBU Zeros Alarm Clear" -- #SUMMARY "DBU 8018: Zeros alarm cleared. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8018 adTSUDBUFIFOAlarmClear TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is no longer in a FIFO alarm condition" -- #TYPE "Alarm - DBU FIFO Alarm Clear" -- #SUMMARY "DBU 8019: FIFO alarm cleared. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8019 adTSUDBURateMismatchClear TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is no longer in a rate mismatch condition" -- #TYPE "Alarm - Rate Mismatch Clear" -- #SUMMARY "DBU 8020: Rate mismatch alarm cleared. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8020 adTSUDBUDataPathErrorClear TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is no longer in a data path error condition" -- #TYPE "Alarm - Data Path Error Clear" -- #SUMMARY "DBU 8021: Data path error cleared. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8021 adTSUDBUBackupMapErrorClear TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is no longer in a backup map error condition" -- #TYPE "Alarm - Backup Map Error Clear" -- #SUMMARY "DBU 8022: Backup map error cleared. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8022 adTSUDBUDCERateAlarmClear TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is no longer in a DCE rate alarm condition" -- #TYPE "Alarm - DCE Rate Alarm Clear" -- #SUMMARY "DBU 8023: DCE rate alarm cleared. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8023 adTSUDBU8sClear TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is no longer in a 8s alarm condition" -- #TYPE "Alarm - 8s Alarm Clear" -- #SUMMARY "DBU 8024: 8s alarm cleared. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8024 adTSUDBU9sClear TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is no longer in a 9s alarm condition" -- #TYPE "Alarm - 9s Alarm Clear" -- #SUMMARY "DBU 8025: 9s alarm cleared. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8025 adTSUDBUD10sClear TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is no longer in a 10s alarm condition" -- #TYPE "Alarm - 10s Clear" -- #SUMMARY "DBU 8026: 10s alarm cleared. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8026 adTSUDBUFound TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that an DBU card has been found in the TSU-XX0. " -- #TYPE "Alarm - DBU Card Found " -- #SUMMARY "DBU 8031: DBU card has been found " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8031 adTSUDBUDLocalLoop-Up TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is looped up local" -- #TYPE "Status - Local Loop-Up" -- #SUMMARY "DBU 8033: Local Loop-Up. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8033 adTSUDBUDBackupEnable1 TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in backup" -- #TYPE "Status - Backup Enable" -- #SUMMARY "DBU 8034: Backup Enable. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8034 adTSUDBUDBackupEnable2 TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in backup" -- #TYPE "Status - Backup Enable" -- #SUMMARY "DBU 8035: Backup Enable. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8035 adTSUDBUDBackupEnable3 TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is in backup" -- #TYPE "Status - Backup Enable" -- #SUMMARY "DBU 8036: Backup Enable. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8036 adTSUDBUDLocalLoop-Down TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is looped down" -- #TYPE "Status - Local Loop-Down" -- #SUMMARY "DBU 8049: Local Loop-Down. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8049 adTSUDBUDBackupDisable1 TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is not in backup" -- #TYPE "Status - Backup Disable" -- #SUMMARY "DBU 8050: Backup Disable. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8050 adTSUDBUDBackupDisable2 TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is not in backup" -- #TYPE "Status - Backup Disable" -- #SUMMARY "DBU 8051: Backup Disable. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8051 adTSUDBUDBackupDisable3 TRAP-TYPE ENTERPRISE adTSUDBU VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the DBU card is not in backup" -- #TYPE "Status - Backup Disable" -- #SUMMARY "DBU 8052: Backup Disable. " -- #SUMMARY "Unit: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 8052 END