ADTRAN-DSUS4W-MIB DEFINITIONS ::= BEGIN -- TITLE: ADTRAN DSU III S4W MIB (1200.042L1) -- FILENAME: DSUS4W.MIB -- PARTNUMBER: 9950.017L1-29A -- AUTHOR: Xiaozhao Zhang -- DATE: 95/09/06 IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 adProdPhysAddress FROM ADTRAN-MIB; -- OBJECT IDENTIFIERS adtran OBJECT IDENTIFIER ::= { enterprises 664 } adProducts OBJECT IDENTIFIER ::= { adtran 1 } adDSUS4W OBJECT IDENTIFIER ::= { adProducts 16 } adMgmt OBJECT IDENTIFIER ::= { adtran 2 } adDSUS4Wmg OBJECT IDENTIFIER ::= { adMgmt 16 } adDSUS4Wprov OBJECT IDENTIFIER ::= { adDSUS4Wmg 1 } adDSUS4WprovNet OBJECT IDENTIFIER ::= { adDSUS4Wprov 1 } adDSUS4WprovDte OBJECT IDENTIFIER ::= { adDSUS4Wprov 2 } adDSUS4WprovTest OBJECT IDENTIFIER ::= { adDSUS4Wprov 3 } adDSUS4WprovDial OBJECT IDENTIFIER ::= { adDSUS4Wprov 4 } adDSUS4WCall OBJECT IDENTIFIER ::= { adDSUS4Wmg 2 } adDSUS4WAdmin OBJECT IDENTIFIER ::= { adDSUS4Wmg 3 } adDSUS4WStatus OBJECT IDENTIFIER ::= { adDSUS4Wmg 4 } -- -- DSU S4W Provision Network Group -- adDSUS4WNetworkType OBJECT-TYPE SYNTAX INTEGER { attMCIandOther(2), ussprint(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Configures the DSU S4W for a specific type of network." ::= {adDSUS4WprovNet 1} adDSUS4WSetNetworkAddr OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Sets the DSU S4W's network address for multipoint networks. The network address range is from 0 to 255." ::= {adDSUS4WprovNet 2} adDSUS4WVleaseOpt OBJECT-TYPE SYNTAX INTEGER { vleaseDisable(1), vleaseEnable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects to disable or enable lease line function for Switch 56. When this function is enabled, the number is automatically redialed if previous call was aborted by the network or by the far end as long as DTR is active." ::= {adDSUS4WprovNet 3} -- --The DSUS4W Provision DTE Group -- adDSUS4WEcho OBJECT-TYPE SYNTAX INTEGER { echoDIS(1), echoENA(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable AT command echo function." ::= {adDSUS4WprovDte 1} adDSUS4WResultCode OBJECT-TYPE SYNTAX INTEGER { resultCodeENA(1), resultCodeDIS(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable AT command response." ::= {adDSUS4WprovDte 2} adDSUS4WCodeFormat OBJECT-TYPE SYNTAX INTEGER { short(1), long(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Change AT command response format to short or long." ::= {adDSUS4WprovDte 3} adDSUS4WCDoption OBJECT-TYPE SYNTAX INTEGER { forcedOn(1), normal(2), fiveSecLoCD(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the DSU S4W's CD option." ::= {adDSUS4WprovDte 4} adDSUS4WTRoption OBJECT-TYPE SYNTAX INTEGER { ignored(1), idleWhenOff(2), offToOnDial1(3), offToOnDial2(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects TR option for the DSU S4W." ::= {adDSUS4WprovDte 5} adDSUS4WDataFormat OBJECT-TYPE SYNTAX INTEGER { asynchronous(1), synchronous(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects either asynchronous or synchronous data mode for the DTE interface." ::= {adDSUS4WprovDte 6} adDSUS4WCSoption OBJECT-TYPE SYNTAX INTEGER { forcedOn(1), followRS(2), onWithCD(3), onWithRSCD(4), fiveSecLoCD(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Select CS options for DSU S4W." ::= {adDSUS4WprovDte 7} adDSUS4WTransmitClock OBJECT-TYPE SYNTAX INTEGER { internal(1), external(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects source of the clock used to transfer data from the DTE to the DSU S4W." ::= {adDSUS4WprovDte 8} adDSUS4WDteRate OBJECT-TYPE SYNTAX INTEGER { sameAsLoop(1), bps2400(2), bps4800(3), bps9600(4), bps19k(5), bps38k(6), bps56sync57async(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the operating DTE speed for the DSU S4W." ::= {adDSUS4WprovDte 9} adDSUS4WEiaContrlALB OBJECT-TYPE SYNTAX INTEGER { contrlalbDIS(1), contrlalbENA(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable EIA controlled ALB." ::= {adDSUS4WprovDte 10} adDSUS4WRtsToCtsDelay OBJECT-TYPE SYNTAX INTEGER { shortDelay(1), longDelay(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects either long or short RS to CS delay when CS is controlled by RS." ::= {adDSUS4WprovDte 11} adDSUS4WEiaCtrlRLB OBJECT-TYPE SYNTAX INTEGER { contrlRlbDIS(1), contrlRlbENA(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable EIA controlled RLB." ::= {adDSUS4WprovDte 12} adDSUS4WConnectorType OBJECT-TYPE SYNTAX INTEGER { rs232(1), v35(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects DTE connector type." ::= {adDSUS4WprovDte 13} adDSUS4WDteCommand OBJECT-TYPE SYNTAX INTEGER { cmdDIS(1), atcmd(2), v25SDLC(3), v25Async(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects DTE interface command mode options." ::= {adDSUS4WprovDte 14} adDSUS4WAsyncWordLen OBJECT-TYPE SYNTAX INTEGER { async9Bits(1), async10Bits(2), async11Bits(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects asynchronous word length." ::= {adDSUS4WprovDte 15} adDSUS4WCombinedSRoption OBJECT-TYPE SYNTAX INTEGER { forcedOn(1), offOOSonly(2), offLOCDonly(3), offTESTonly(4), offTESTOOD(5), offTESTLOCD(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the operating mode for the SR lead." ::= {adDSUS4WprovDte 16} -- --The DSU S4W Provision Test Group -- adDSUS4WTestCommand OBJECT-TYPE SYNTAX INTEGER { exitTest(1), dteOnly(2), localDigital(4), enableRDL(5), disableRDL(6), remoteLoop(7), remoteWithTP(8), dteWithTP(9), testPattern(10), dteAndLoopTest(11), loopOnlyTest(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects one of the DSU S4W test options to perform." ::= {adDSUS4WprovTest 1} adDSUS4WTestPattern OBJECT-TYPE SYNTAX INTEGER { pattern2047(1), pattern511(2), stress1(3), stress2(4), stress3(5), stress4(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects a test pattern to use during DTE and network test operations." ::= {adDSUS4WprovTest 2} adDSUS4WAcceptRDL OBJECT-TYPE SYNTAX INTEGER { disableRDL(1), enableRDL(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or disables DSU S4W acceptance of remote digital loopback." ::= {adDSUS4WprovTest 3} adDSUS4WHealthCheck OBJECT-TYPE SYNTAX INTEGER { healthCheck(1) } ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation with value of 1 performs a self test in the DSU S4W." ::= {adDSUS4WprovTest 4} adDSUS4WErrorCount OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation with non zero value inserts one error into the test pattern, and zero value clears the error count." ::= {adDSUS4WprovTest 5} -- --The DSU S4W Provision Dial Group -- adDSUS4WStorePhoneNum1 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET stores phone number into register 1, max 32 digits." ::= {adDSUS4WprovDial 1} adDSUS4WStorePhoneNum2 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET stores phone number into register 2, max 32 digits." ::= {adDSUS4WprovDial 2} adDSUS4WStorePhoneNum3 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET stores phone number into register 3, max 32 digits." ::= {adDSUS4WprovDial 3} adDSUS4WstorePhoneNum4 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET stores phone number into register 4, max 32 digits." ::= {adDSUS4WprovDial 4} adDSUS4WStorePhoneNum5 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET stores phone number into register 5, max 32 digits." ::= {adDSUS4WprovDial 5} adDSUS4WStorePhoneNum6 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET stores phone number into register 6, max 32 digits." ::= {adDSUS4WprovDial 6} adDSUS4WStorePhoneNum7 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET stores phone number into register 7, max 32 digits." ::= {adDSUS4WprovDial 7} adDSUS4WStorePhoneNum8 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET stores phone number into register 8, max 32 digits." ::= {adDSUS4WprovDial 8} adDSUS4WStorePhoneNum9 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET stores phone number into register 9, max 32 digits." ::= {adDSUS4WprovDial 9} adDSUS4WStorePhoneNum10 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET stores phone number into register 10, max 32 digits." ::= {adDSUS4WprovDial 10} adDSUS4WAutoAnswer OBJECT-TYPE SYNTAX INTEGER { autoanswerDIS(1), autoanswerENA(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects auto answer option for incoming calls for Switch 56 operation." ::= {adDSUS4WprovDial 11} adDSUS4WRs366EonOpt OBJECT-TYPE SYNTAX INTEGER { donotuseEndofNumber (1), useEndofNumber(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This command selects whether to use End of Number." ::= {adDSUS4WprovDial 12} -- --The DSU S4W AR Call Group -- adDSUS4WAnswerCall OBJECT-TYPE SYNTAX INTEGER { answer(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The DSU S4W executes a connect sequence in response to this SET command." ::= {adDSUS4WCall 1} adDSUS4WMakeCall OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation causes the DSU S4W to go off hook and dial the accompanying number, max 32 digits." ::= {adDSUS4WCall 2} adDSUS4WDialStored OBJECT-TYPE SYNTAX INTEGER { dialStored1(2), dialStored2(3), dialStored3(4), dialStored4(5), dialStored5(6), dialStored6(7), dialStored7(8), dialStored8(9), dialStored9(10), dialStored10(11) } ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation causes the DSU S4W to go off hook and dial the number stored in one of the ten phone number registers (2 dials register 1, ... 11 dials register 10)." ::= {adDSUS4WCall 3} adDSUS4WHangup OBJECT-TYPE SYNTAX INTEGER { hangup(1) } ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation with value of 1 causes the DSU S4W to terminate the current call." ::= {adDSUS4WCall 4} adDSUS4WOnline OBJECT-TYPE SYNTAX INTEGER { online(1) } ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation with value of 1 changes the DSU S4W into data mode." ::= {adDSUS4WCall 5} --The DSU S4W AR Admin Group adDSUS4WReset OBJECT-TYPE SYNTAX INTEGER { reset(1) } ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation with value of 1 causes the DSU S4W to perform a firmware reset." ::= {adDSUS4WAdmin 1} adDSUS4WFactoryOpt OBJECT-TYPE SYNTAX INTEGER { factoryOpt1(1), factoryOpt2(2), factoryOpt3(3), factoryOpt4(4) } ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation loads one of four factory default options." ::= {adDSUS4WAdmin 2} adDSUS4WRestoreProfile OBJECT-TYPE SYNTAX INTEGER { restoreProfile1(1), restoreProfile2(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation restores user profile from non-volatile memory." ::= {adDSUS4WAdmin 3} adDSUS4WSelectUserProfile OBJECT-TYPE SYNTAX INTEGER { profile1(1), profile2(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A SET selects the power up user profile for DSU S4W." ::= {adDSUS4WAdmin 4} adDSUS4WS4WSetRemoteNetAddr OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "A SET selects the address for the remote unit which the DSU S4W will remotely configure." ::= {adDSUS4WAdmin 5} adDSUS4WRemoteTimeout OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "A SET selects the timeout for how long the DSU S4W will remain in remote configuration mode after receiving the last command. A zero value disables the timeout, 1 to 255 enables the timeout in seconds." ::= {adDSUS4WAdmin 6} adDSUS4WInitRemote OBJECT-TYPE SYNTAX INTEGER { initRemote(4) } ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation with value of 4 establishes the remote configuration link between the DSU S4W and the remote unit." ::= {adDSUS4WAdmin 7} adDSUS4WExitRemote OBJECT-TYPE SYNTAX INTEGER { exitRemote(1) } ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation with value of 1 terminates the remote configuration link between the DSU S4W and the remote unit." ::= {adDSUS4WAdmin 8} adDSUS4WFrontPanel OBJECT-TYPE SYNTAX INTEGER { frontPanelDIS(1), frontPanelENA(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable front panel operations." ::= {adDSUS4WAdmin 9} adDSUS4WSerialNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Customer programmable parameter, max 10 characters." ::= {adDSUS4WAdmin 10} adDSUS4WRemoteConfig OBJECT-TYPE SYNTAX INTEGER { remoteDIS(1), remoteENA(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable remote configuration of the DSU S4W." ::= {adDSUS4WAdmin 11} adDSUS4Watid OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Contains DSU S4W product identification information." ::= {adDSUS4WAdmin 12} adDSUS4WTrapArm OBJECT-TYPE SYNTAX INTEGER { trapDISARM(1), trapARM(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A SET operation arms or disarms the DSU S4W trap functions." ::= {adDSUS4WAdmin 13} -- --The DSU S4W Status Group -- adDSUS4WGeneralStatus OBJECT-TYPE SYNTAX INTEGER { noTestNoRemote(1), dteOnly(2), localLoopOnly(3), localDTEandLoop(4), remoteConfigMaster(5), remoteConfigSlave(6), remoteLoop(7), remoteLoopTP(8), dteWithTP(9), testPattern(10), dteAndLoopTest(11), loopOnlyTest(12), rdlFromDSU(13), dbuTestOrig(14), dbuTestAnswer(15) } ACCESS read-only STATUS mandatory DESCRIPTION "Variable contains DSU S4W test and remote configuration status information." ::= {adDSUS4WStatus 1} adDSUS4WSelfTestStatus OBJECT-TYPE SYNTAX INTEGER { selfTestPassed(1), romTestFailed(2), ramTestFailed(3), lalTestFailed(4), eeTestFailed(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Variable contains DSU S4W self test results." ::= {adDSUS4WStatus 2} adDSUS4WLoopStatus OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates loop status information. The adDSUloopstatus is a bit map represented as a sum, therefore, it can represent multiple loop status simutaneously. The variable bit position are: 1 OOS/OOF code received from network 2 No receive signal 4 No sealing current 32 RT test from phone company 64 LL test from phone company 128 Dial back is in progress or backup line is active" ::= {adDSUS4WStatus 3} adDSUS4WDialingStatus OBJECT-TYPE SYNTAX INTEGER (0..32) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates dialing status information. The adDSUdialingstatus is a bit map represented as a sum, therefore, it can represent multiple dialing status simutaneously. The variable bit position are: 1 DSU is dialing a number 2 DSU is online passing data 4 No wink from switch(cleared after 5 seconds) 8 Number is busy 16 No answer(cleared after 5 seconds) " ::= {adDSUS4WStatus 4} adDSUS4WDteStatus1 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates DTE signal status information. The adDSUDteStatus1 is a bit map represented as a sum, therefore, it can represent multiple DTE signal status simutaneously. The variable bit position are: 1 TM is active 2 RD is active 4 TD is active 8 CD is active 16 CS is active 32 RS is active 64 SR is active 128 TR is active " ::= {adDSUS4WStatus 5} adDSUS4WDteStatus2 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates DTE signal status information. The adDSUDTEstatus2 is a bit map represented as a sum, therefore, it can represent multiple DTE signal status simutaneously. The variable bit position are: 1 RI is active 2 Not defined yet 4 Not defined yet 8 Not defined yet 16 LLB 32 RLB 64 Not defined yet 128 Not defined yet " ::= {adDSUS4WStatus 6} adDSUS4WCommandStatus OBJECT-TYPE SYNTAX INTEGER { successful(1), failed(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether the snmp command is successfully executed." ::= {adDSUS4WStatus 7} -- -- The DSU S4W Enterprise Specific Traps -- adDSUS4WColdStart TRAP-TYPE ENTERPRISE adDSUS4W VARIABLES { adProdPhysAddress } DESCRIPTION "The unit has powered up." -- #TYPE "Status - Cold Start" -- #SUMMARY "DSUS4W 1600: A Cold Start has occurred for " -- #SUMMARY "Unit Id: %x" -- #ARGUMENTS {0} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 1600 adDSUS4WInTest TRAP-TYPE ENTERPRISE adDSUS4W VARIABLES { adProdPhysAddress } DESCRIPTION "This indicates that DSU S4W enters test mode." -- #TYPE "Status - Test Mode" -- #SUMMARY "DSUS4W 1601: In Test state exists for " -- #SUMMARY "Unit Id: %x" -- #ARGUMENTS {0} -- #SEVERITY WARNING -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 1601 adDSUS4WEndTest TRAP-TYPE ENTERPRISE adDSUS4W VARIABLES { adProdPhysAddress } DESCRIPTION "This indicates that DSU S4W exits test mode." -- #TYPE "Status - Test Mode" -- #SUMMARY "DSUS4W 1611: End Test state exists for " -- #SUMMARY "Unit Id: %x" -- #ARGUMENTS {0} -- #SEVERITY WARNING -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 1611 adDSUS4WInAlarm TRAP-TYPE ENTERPRISE adDSUS4W VARIABLES { adProdPhysAddress } DESCRIPTION "This indicates that DSU S4W enters alarm mode." -- #TYPE "Status - Alarm Mode" -- #SUMMARY "DSUS4W 1602: In Alarm state exists for " -- #SUMMARY "Unit Id: %x" -- #ARGUMENTS {0} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 1602 adDSUS4WEndAlarm TRAP-TYPE ENTERPRISE adDSUS4W VARIABLES { adProdPhysAddress } DESCRIPTION "This indicates that DSUS4W exits alarm mode." -- #TYPE "Status - Alarm Mode" -- #SUMMARY "DSUS4W 1612: End Alarm state exists for " -- #SUMMARY "Unit Id: %x" -- #ARGUMENTS {0} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 1612 adDSUS4WRemoteCFGDisable TRAP-TYPE ENTERPRISE adDSUS4W VARIABLES { adProdPhysAddress } DESCRIPTION "This indicates that DSU S4W can not establish remote configuration." -- #TYPE "Status - Remote Configuration Mode" -- #SUMMARY "DSUS4W 1603: Remote configuration disable state exists for " -- #SUMMARY "Unit Id: %x" -- #ARGUMENTS {0} -- #SEVERITY WARNING -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 1603 adDSUS4WRemoteCFGEnable TRAP-TYPE ENTERPRISE adDSUS4W VARIABLES { adProdPhysAddress } DESCRIPTION "This indicates that DSU S4W can establish remote configuration." -- #TYPE "Status - Remote Configuration Mode" -- #SUMMARY "DSUS4W 1613: Remote configuration enable state exists for " -- #SUMMARY "Unit Id: %x" -- #ARGUMENTS {0} -- #SEVERITY WARNING -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 1613 adDSUS4WRemoteMasterOn TRAP-TYPE ENTERPRISE adDSUS4W VARIABLES { adProdPhysAddress } DESCRIPTION "This indicates that DSU S4W enters the remote configuration master mode." -- #TYPE "Status - Remote Configuration Master Mode" -- #SUMMARY "DSUS4W 1604: Remote master mode ON state exists for " -- #SUMMARY "Unit Id: %x" -- #ARGUMENTS {0} -- #SEVERITY WARNING -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 1604 adDSUS4WRemoteMasterOff TRAP-TYPE ENTERPRISE adDSUS4W VARIABLES { adProdPhysAddress } DESCRIPTION "This indicates that DSU S4W enters the remote configuration slave mode." -- #TYPE "Status - Remote Configuration Master Mode" -- #SUMMARY "DSUS4W 1614: Remote master mode OFF state exists for " -- #SUMMARY "Unit Id: %x" -- #ARGUMENTS {0} -- #SEVERITY WARNING -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 1614 END