ADTRAN-TSU100NxMIB DEFINITIONS ::= BEGIN -- TITLE: Adtran 100Nx -- FILENAME: nx100.MIB -- PARTNUMBER: 1200.052L1 -- AUTHOR: Brian Prevallet -- DATE: 97/05/XX -- This MIB defines the Plug In NxOption module IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString, ifIndex FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 dsx1LineStatus FROM RFC1406-MIB adProdPhysAddress FROM ADTRAN-MIB; -- OBJECT IDENTIFIERS adtran OBJECT IDENTIFIER ::= { enterprises 664 } adProducts OBJECT IDENTIFIER ::= { adtran 1 } adMgmt OBJECT IDENTIFIER ::= { adtran 2 } ------------------------------------------------------------------------------ -- nx v35 530 TSU 100 ------------------------------------------------------------------------------ adTSUOCMg OBJECT IDENTIFIER ::= { adMgmt 1000 } adNx100Config OBJECT IDENTIFIER ::= { adTSUOCMg 1 } adNx100CDBConfig OBJECT IDENTIFIER ::= { adNx100Config 1 } adNx100TWConfig OBJECT IDENTIFIER ::= { adNx100Config 2 } adTSUNXBase OBJECT IDENTIFIER ::= { adProducts 70 } adTSUNXBasetraps OBJECT IDENTIFIER ::= { adMgmt 70 } adTSUNXBaseconfig OBJECT IDENTIFIER ::= { adTSUNXBasetraps 1 } -- TWatch accessable item tables -- this table is used to monitor status of nx's adNx100MonitorStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx100MonitorStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Monitor status for all Plug In NX's" ::= {adNx100TWConfig 54} adNx100MonitorStatusEntry OBJECT-TYPE SYNTAX ADNx100MonitorStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the Monitor Status Table" INDEX { adTWifIndex } ::= {adNx100MonitorStatusTable 1} ADNx100MonitorStatusEntry ::= SEQUENCE { adTWifIndex INTEGER, adNx100MonitorStatus OCTET STRING } adTWifIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx100MonitorStatusEntry 1 } adNx100MonitorStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Base Nx56/64 Monitor Status State: RTS CTS DCD DSR" ::= { adNx100MonitorStatusEntry 16388 } -- end of monitor status table -- this table is used to monitor the data leads adNx100MonitorDataTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx100MonitorDataEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Monitor Data for all Plug In NX's" ::= {adNx100TWConfig 53} adNx100MonitorDataEntry OBJECT-TYPE SYNTAX ADNx100MonitorDataEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the Monitor Data Table" INDEX { adTWMonIndex } ::= {adNx100MonitorDataTable 1} ADNx100MonitorDataEntry ::= SEQUENCE { adTWMonIndex INTEGER, adNx100MonitorData OCTET STRING } adTWMonIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx100MonitorDataEntry 1 } adNx100MonitorData OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Base Nx56/64 Monitor Data State: TXD RXD ETC LCK " ::= { adNx100MonitorDataEntry 16388 } --end of monitor data table -- this table is used for nx loopback status adNx100LoopBackStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx100LoopBackStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Loop back info for all plug-in nx's" ::= {adNx100TWConfig 5} adNx100LoopBackStatusEntry OBJECT-TYPE SYNTAX ADNx100LoopBackStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the loop back Table" INDEX { adTWLBIndex } ::= {adNx100LoopBackStatusTable 1} ADNx100LoopBackStatusEntry ::= SEQUENCE { adTWLBIndex INTEGER, adNx100LoopBackStatus INTEGER } adTWLBIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx100LoopBackStatusEntry 1 } adNx100LoopBackStatus OBJECT-TYPE SYNTAX INTEGER { noLoop (0), loopedByRemote (1), remoteUnitLooped (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Base Nx56/64 Loopback Status" ::= { adNx100LoopBackStatusEntry 514 } --end of loopback table -- this table is used to monitor port rate of the nx's adNx100PortRateTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx100PortRateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Port Rate for all Plug In NX's" ::= {adNx100TWConfig 51} adNx100PortRateEntry OBJECT-TYPE SYNTAX ADNx100PortRateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the Port Rate Table" INDEX { adTWPortIndex } ::= {adNx100PortRateTable 1} ADNx100PortRateEntry ::= SEQUENCE { adTWPortIndex INTEGER, adNx100PortRate INTEGER } adTWPortIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx100PortRateEntry 1 } adNx100PortRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Base Nx56/64 Port Rate" ::= { adNx100PortRateEntry 1024 } -- end of port rate table -- a set to clear the 511 test pattern counter adNx100Clear511counterTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx100Clear511counterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Set to clear 511 errors" ::= {adNx100TWConfig 16440} adNx100Clear511counterEntry OBJECT-TYPE SYNTAX ADNx100Clear511counterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A set clears the 511 error counter" INDEX { adTWCtrIndex } ::= {adNx100Clear511counterTable 1} ADNx100Clear511counterEntry ::= SEQUENCE { adTWCtrIndex INTEGER, adNx100Clear511counter INTEGER } adTWCtrIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx100Clear511counterEntry 1 } adNx100Clear511counter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A set clears the 511 error counter" ::= { adNx100Clear511counterEntry 512 } -- end of table -- a set to inject a 511 pattern error adNx100Inj511errorTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx100Inj511errorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "511 error inject" ::= {adNx100TWConfig 16442} adNx100Inj511errorEntry OBJECT-TYPE SYNTAX ADNx100Inj511errorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A set injects a 511 error" INDEX { adTWErrIndex } ::= {adNx100Inj511errorTable 1} ADNx100Inj511errorEntry ::= SEQUENCE { adTWErrIndex INTEGER, adNx100Inj511error INTEGER } adTWErrIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx100Inj511errorEntry 1 } adNx100Inj511error OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A set injects a 511 error" ::= { adNx100Inj511errorEntry 512 } -- end of monitor status table -- 511 test pattern results table adNx100511resultsTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx100511resultsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "511 test pattern results" ::= {adNx100TWConfig 8} adNx100511resultsEntry OBJECT-TYPE SYNTAX ADNx100511resultsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "511 test pattern results" INDEX { adTWTestIndex } ::= {adNx100511resultsTable 1} ADNx100511resultsEntry ::= SEQUENCE { adTWTestIndex INTEGER, adNx100511resultsSync INTEGER, adNx100511resultsES INTEGER } adTWTestIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx100511resultsEntry 1 } adNx100511resultsSync OBJECT-TYPE SYNTAX INTEGER { noSync (0), sync (1) } ACCESS read-only STATUS mandatory DESCRIPTION "511 test pattern sync" ::= { adNx100511resultsEntry 514 } adNx100511resultsES OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "511 test pattern errors" ::= { adNx100511resultsEntry 1027 } -- end of table -- CDB Items table based on ifindex adNx100CDBTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx100CDBEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Nx Slot table" ::= { adNx100CDBConfig 1 } adNx100CDBEntry OBJECT-TYPE SYNTAX ADNx100CDBEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Nx table." INDEX { adCDBifIndex } ::= { adNx100CDBTable 1 } ADNx100CDBEntry ::= SEQUENCE { adCDBifIndex INTEGER, adNx100Interface INTEGER, adNx100TxClock INTEGER, adNx100DTEData INTEGER, adNx100CTS INTEGER, adNx100DataRatePer INTEGER, adNx100LoopBack INTEGER, adNx100DCD INTEGER, adNx100511 INTEGER, adNx100ZeroInhibit INTEGER, adNx100DSR INTEGER } adCDBifIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx100CDBEntry 1 } adNx100Interface OBJECT-TYPE SYNTAX INTEGER { eia-v35-530 (2), v35 (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Physical connection used for NX56/64" ::= { adNx100CDBEntry 2 } adNx100TxClock OBJECT-TYPE SYNTAX INTEGER { internal (4), internal-Invert (5), external (6) } ACCESS read-write STATUS mandatory DESCRIPTION "Transmit Clock Source" ::= { adNx100CDBEntry 3 } adNx100DTEData OBJECT-TYPE SYNTAX INTEGER { normal (7), invert (8) } ACCESS read-write STATUS mandatory DESCRIPTION "DTE Data format" ::= { adNx100CDBEntry 4 } adNx100CTS OBJECT-TYPE SYNTAX INTEGER { forcedOn (9), normal (10) } ACCESS read-write STATUS mandatory DESCRIPTION "CTS Mode" ::= { adNx100CDBEntry 5 } adNx100DataRatePer OBJECT-TYPE SYNTAX INTEGER { rate56 (11), rate64 (12) } ACCESS read-write STATUS mandatory DESCRIPTION "Data Rate Per DS0" ::= { adNx100CDBEntry 6 } adNx100LoopBack OBJECT-TYPE SYNTAX INTEGER { off (13), netLocal (14), remote (15) } ACCESS read-write STATUS mandatory DESCRIPTION "LoopBack Mode" ::= { adNx100CDBEntry 7 } adNx100DCD OBJECT-TYPE SYNTAX INTEGER { forcedOn (16), normal (17) } ACCESS read-write STATUS mandatory DESCRIPTION "DCD Mode" ::= { adNx100CDBEntry 8 } adNx100511 OBJECT-TYPE SYNTAX INTEGER { off (0), on (1) } ACCESS read-write STATUS mandatory DESCRIPTION "511 Pattern Mode" ::= { adNx100CDBEntry 11 } adNx100ZeroInhibit OBJECT-TYPE SYNTAX INTEGER { off (0), on (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Zero Inhibit Mode" ::= { adNx100CDBEntry 12 } adNx100DSR OBJECT-TYPE SYNTAX INTEGER { forcedOn (16), normal (17) } ACCESS read-write STATUS mandatory DESCRIPTION "DSR Mode" ::= { adNx100CDBEntry 15 } -------------------------------------------- -- TSU-XX0 NXBase Enterprise Specific Traps -------------------------------------------- adTSUNXBaseClockSlip TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase card is in a clock-slip alarm condition" -- #TYPE "Alarm - NXBase Clock Slip" -- #SUMMARY "NXBase 8101: Clock-slip alarm condition. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7001 adTSUNXBasePllAlarm TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase card is in a PLL alarm condition" -- #TYPE "Alarm - NXBase PLL Alarm" -- #SUMMARY "NXBase 8102: PLL alarm condition. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7002 adTSUNXBaseZeroAlarm TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "An excessive number of consecutive zeros have been detected from the DTE. " -- #TYPE "Alarm - NXBase Zero Alarm" -- #SUMMARY "NXBase 7003: Zero alarm condition. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY WARNING -- #GENERIC 6 -- #CATEGORY "Threshold Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7003 adTSUNXBaseFIFOALRM TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase is in FIFO Alarm condition. " -- #TYPE "Alarm - NXBase FIFO Alarm" -- #SUMMARY "NXBase 7004: FIFO Alarm " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7004 adTSUNXBaseEXTClockAlarm TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase card is not receiving a valid clock signal from the DTE. " -- #TYPE "Alarm - NXBase External Clock Alarm" -- #SUMMARY "NXBase 7005: External Clock Alarm " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7005 adTSUNXBaseLost TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase card has been removed from the chassis or that the card has failed. " -- #TYPE "Alarm - NXBase Card Not Responding " -- #SUMMARY "NXBase 7015: NXBase card is not responding " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7015 adTSUNXBaseClockSlipClear TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase card is no longer in a clock-slip alarm condition" -- #TYPE "Alarm - NXBase Clock Slip Clear" -- #SUMMARY "NXBase 7017: Clock-slip alarm cleared. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7017 adTSUNXBasePllALRMCLR TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase card is no longer in a PLL alarm condition" -- #TYPE "Alarm - NXBase PLL Alarm Clear" -- #SUMMARY "NXBase 7018: PLL alarm cleared. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7018 adTSUNXBaseZeroALRMCLR TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase card is no longer in a Zero Alarm condition" -- #TYPE "Alarm - NXBase Zero Alarm Clear" -- #SUMMARY "NXBase 7019: Zero alarm cleared. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY WARNING -- #GENERIC 6 -- #CATEGORY "Threshold Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7019 adTSUNXBaseFIFOALRMCLR TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase has cleared FIFO Alarm condition. " -- #TYPE "Alarm - NXBase FIFO Alarm Clear" -- #SUMMARY "NXBase 7020: FIFO Alarm Clear " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7020 adTSUNXBaseEXTCLKALRMCLR TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase card is now receiving a valid clock signal from the DTE. " -- #TYPE "Alarm - NXBase External Clock Alarm Clear" -- #SUMMARY "NXBase 7021: External Clock Alarm cleared " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7021 adTSUNXBaseFound TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that an NXBase card has been found in the TSU-XX0. " -- #TYPE "Alarm - NXBase Card Found " -- #SUMMARY "NXBase 7031: NXBase card has been found " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7031 adTSUNXBaseLoopup TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase has been looped-up (bilateral loopback) from a local source. " -- #TYPE "Status - NXBase Loop-up" -- #SUMMARY "NXBase 7033: Looped-up " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7033 adTSUNXBaseRemoteLoopup TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase interface has been looped-up (bilateral loopback) from a remote source. " -- #TYPE "Status - NXBase Remote Loop-up" -- #SUMMARY "NXBase 7034: Remotely looped-up " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7034 adTSUNXBase511On TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase is sending 511 pattern towards the network. " -- #TYPE "Status - MxDBU 511 Pattern On" -- #SUMMARY "NXBase 7035: NXBase 511 pattern on " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7035 adTSUNXBaseLoopdown TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase has been looped-down (bilateral loopback) from a local source. " -- #TYPE "Status - NXBase Loop-down " -- #SUMMARY "NXBase 7049: Looped-down " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7049 adTSUNXBaseRemotedown TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase has been looped-down (bilateral loopback) from a remote source. " -- #TYPE "Status - NXBase Remote Loop-down " -- #SUMMARY "NXBase 7050: Remote looped-down " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7050 adTSUNXBase511Off TRAP-TYPE ENTERPRISE adTSUNXBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXBase is no longer sending 511 pattern towards the network. " -- #TYPE "Status - NxBase 511 Pattern Off" -- #SUMMARY "NXBase 7051: NXBase 511 pattern off " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 7051 END