ADTRAN-TSU1X0eNxMIB DEFINITIONS ::= BEGIN -- TITLE: Adtran Nx V.35 TSU1X0e -- FILENAME: nx1X0e.MIB -- PARTNUMBER: 1202.052L1 & 1202.129 -- AUTHOR: Brian Prevallet -- DATE: 98/1/XX -- This MIB defines the TSU1X0e Nx port IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString, ifIndex FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 dsx1LineStatus FROM RFC1406-MIB adProdPhysAddress FROM ADTRAN-MIB; -- OBJECT IDENTIFIERS adtran OBJECT IDENTIFIER ::= { enterprises 664 } adProducts OBJECT IDENTIFIER ::= { adtran 1 } adMgmt OBJECT IDENTIFIER ::= { adtran 2 } ------------------------------------------------------------------------------ -- nx TSU 1X0e ------------------------------------------------------------------------------ adTSUOCMg OBJECT IDENTIFIER ::= { adMgmt 1000 } adNx1X0eConfig OBJECT IDENTIFIER ::= { adTSUOCMg 31 } adNx1X0eCDBConfig OBJECT IDENTIFIER ::= { adNx1X0eConfig 1 } adNx1X0eTWConfig OBJECT IDENTIFIER ::= { adNx1X0eConfig 2 } adTSUNXeBase OBJECT IDENTIFIER ::= { adProducts 100 } adTSUNXeBasetraps OBJECT IDENTIFIER ::= { adMgmt 100 } adTSUNXeBaseconfig OBJECT IDENTIFIER ::= { adTSUNXeBasetraps 1 } adNx1X0edte-statusTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx1X0edte-statusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Monitor status for all the base NX" ::= {adNx1X0eTWConfig 54} adNx1X0edte-statusEntry OBJECT-TYPE SYNTAX ADNx1X0edte-statusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the Dte Status Table" INDEX { adTWmsIndex } ::= {adNx1X0edte-statusTable 1} ADNx1X0edte-statusEntry ::= SEQUENCE { adTWmsIndex INTEGER, adNx1X0edte-status OCTET STRING } adTWmsIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx1X0edte-statusEntry 1 } adNx1X0edte-status OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Base Nx1X0e Monitor Status State: RTS CTS DCD DSR" ::= { adNx1X0edte-statusEntry 16388 } -- end of table -- this table is used to monitor the data leads adNx1X0edte-dataClockTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx1X0edte-dataClockEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Monitor Data for the Nx1X0e" ::= {adNx1X0eTWConfig 53} adNx1X0edte-dataClockEntry OBJECT-TYPE SYNTAX ADNx1X0edte-dataClockEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the Monitor Data Table" INDEX { adTWmdIndex } ::= {adNx1X0edte-dataClockTable 1} ADNx1X0edte-dataClockEntry ::= SEQUENCE { adTWmdIndex INTEGER, adNx1X0edte-dataClock OCTET STRING } adTWmdIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx1X0edte-dataClockEntry 1 } adNx1X0edte-dataClock OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Base Nx1X0e Monitor Data State: TXD RXD XSO LCK " ::= { adNx1X0edte-dataClockEntry 16388 } --end of monitor data table -- this table is used to monitor port rate of the nx's adNx1X0ePortRateTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx1X0ePortRateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Port Rate for all Plug In NX's" ::= {adNx1X0eTWConfig 51} adNx1X0ePortRateEntry OBJECT-TYPE SYNTAX ADNx1X0ePortRateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the Port Rate Table" INDEX { adTWprIndex } ::= {adNx1X0ePortRateTable 1} ADNx1X0ePortRateEntry ::= SEQUENCE { adTWprIndex INTEGER, adNx1X0ePortRate INTEGER } adTWprIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx1X0ePortRateEntry 1 } adNx1X0ePortRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Base Nx1X0e Port Rate" ::= { adNx1X0ePortRateEntry 1024 } -- end of port rate table -- this table is used to monitor 511 test results adNx1X0e511PattResultsTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx1X0e511PattResultsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Pattern results table for the Nx1X0e" ::= {adNx1X0eTWConfig 59} adNx1X0e511PattResultsEntry OBJECT-TYPE SYNTAX ADNx1X0e511PattResultsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry in the pattern results Table" INDEX { adNx1X0e511PattResultsIndex } ::= {adNx1X0e511PattResultsTable 1} ADNx1X0e511PattResultsEntry ::= SEQUENCE { adNx1X0e511PattResultsIndex INTEGER, adNx1X0e511PattResultsSync INTEGER, adNx1X0e511PattResultsES INTEGER } adNx1X0e511PattResultsIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx1X0e511PattResultsEntry 1 } adNx1X0e511PattResultsSync OBJECT-TYPE SYNTAX INTEGER { sync (1), nosync (0) } ACCESS read-only STATUS mandatory DESCRIPTION "Nx1X0e pattern results sync" ::= { adNx1X0e511PattResultsEntry 512 } adNx1X0e511PattResultsES OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Nx1X0e pattern results " ::= { adNx1X0e511PattResultsEntry 1025 } --end of table -- a set to clear the 511 test pattern counter adNx1X0eClear511counterTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx1X0eClear511counterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Set to clear 511 errors" ::= {adNx1X0eTWConfig 16440} adNx1X0eClear511counterEntry OBJECT-TYPE SYNTAX ADNx1X0eClear511counterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A set clears the 511 error counter" INDEX { adTWccIndex } ::= {adNx1X0eClear511counterTable 1} ADNx1X0eClear511counterEntry ::= SEQUENCE { adTWccIndex INTEGER, adNx1X0eClear511counter INTEGER } adTWccIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx1X0eClear511counterEntry 1 } adNx1X0eClear511counter OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A set clears the 511 error counter" ::= { adNx1X0eClear511counterEntry 512 } -- end of table -- a set to inject a 511 pattern error adNx1X0eInj511errorTable OBJECT-TYPE SYNTAX SEQUENCE OF ADNx1X0eInj511errorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "511 error inject" ::= {adNx1X0eTWConfig 16442} adNx1X0eInj511errorEntry OBJECT-TYPE SYNTAX ADNx1X0eInj511errorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A set injects a 511 error" INDEX { adTWieIndex } ::= {adNx1X0eInj511errorTable 1} ADNx1X0eInj511errorEntry ::= SEQUENCE { adTWieIndex INTEGER, adNx1X0eInj511error INTEGER } adTWieIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx1X0eInj511errorEntry 1 } adNx1X0eInj511error OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A set injects a 511 error" ::= { adNx1X0eInj511errorEntry 512 } -- end of table -- CDB Items table based on ifindex adNx1X0eCDBTable OBJECT-TYPE SYNTAX SEQUENCE OF ADCDBNx1X0eEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Nx1X0e Slot table" ::= { adNx1X0eCDBConfig 1 } adNx1X0eCDBEntry OBJECT-TYPE SYNTAX ADCDBNx1X0eEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Nx1X0e table." INDEX { adNx1X0eifIndex } ::= { adNx1X0eCDBTable 1 } ADCDBNx1X0eEntry ::= SEQUENCE { adNx1X0eifIndex INTEGER, adNx1X0eLoopback INTEGER, adNx1X0eTxClock INTEGER, adNx1X0eData INTEGER, adNx1X0eCTS INTEGER, adNx1X0eDSORate INTEGER, adNx1X0eDTELoopback INTEGER, adNx1X0eDCD INTEGER, adNx1X0e511Pattern INTEGER, adNx1X0e0Inhib INTEGER, adNx1X0eDSR INTEGER, adNx1X0eInbandMode INTEGER, adNx1X0eTxClockSrc INTEGER } adNx1X0eifIndex OBJECT-TYPE SYNTAX INTEGER (2..26) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the object instance." ::= { adNx1X0eCDBEntry 1 } adNx1X0eLoopback OBJECT-TYPE SYNTAX INTEGER { off (0), on (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Loopback mode for the Nx1X0e" ::= { adNx1X0eCDBEntry 2 } adNx1X0eTxClock OBJECT-TYPE SYNTAX INTEGER { normal (3), invert (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Transmit clock" ::= { adNx1X0eCDBEntry 3 } adNx1X0eData OBJECT-TYPE SYNTAX INTEGER { normal (3), invert (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Data Mode of the Nx1X0e" ::= { adNx1X0eCDBEntry 4 } adNx1X0eCTS OBJECT-TYPE SYNTAX INTEGER { force-on (5), normal (6) } ACCESS read-write STATUS mandatory DESCRIPTION "CTS options" ::= { adNx1X0eCDBEntry 5 } adNx1X0eDSORate OBJECT-TYPE SYNTAX INTEGER { rate56k (7), rate64k (8) } ACCESS read-write STATUS mandatory DESCRIPTION "DSO data rate of the Nx1X0e" ::= { adNx1X0eCDBEntry 6 } adNx1X0eDTELoopback OBJECT-TYPE SYNTAX INTEGER { off (9), port-local (10), remote (11) } ACCESS read-write STATUS mandatory DESCRIPTION "DTE loopback mode" ::= { adNx1X0eCDBEntry 7 } adNx1X0eDCD OBJECT-TYPE SYNTAX INTEGER { force-on (5), normal (6) } ACCESS read-write STATUS mandatory DESCRIPTION "DCD options" ::= { adNx1X0eCDBEntry 8 } adNx1X0e511Pattern OBJECT-TYPE SYNTAX INTEGER { off (0), on (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Nx1X0e 511 test pattern: on/off" ::= { adNx1X0eCDBEntry 11 } adNx1X0e0Inhib OBJECT-TYPE SYNTAX INTEGER { off (0), oOn (1) } ACCESS read-write STATUS mandatory DESCRIPTION "0 inhibit option: off/on" ::= { adNx1X0eCDBEntry 12 } adNx1X0eDSR OBJECT-TYPE SYNTAX INTEGER { force-on (5), normal (6) } ACCESS read-write STATUS mandatory DESCRIPTION "DSR option" ::= { adNx1X0eCDBEntry 15 } adNx1X0eInbandMode OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), on-demand (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Nx1X0e inband mode: off, on, on demand" ::= { adNx1X0eCDBEntry 16 } adNx1X0eTxClockSrc OBJECT-TYPE SYNTAX INTEGER { internal (49), external (50) } ACCESS read-write STATUS mandatory DESCRIPTION "Nx1X0e transmit clock source: internal, external" ::= { adNx1X0eCDBEntry 30 } -------------------------------------------- -- TSU-XX0e NXeBase Enterprise Specific Traps -------------------------------------------- adTSUNXeBaseClockSlip TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase is in a clock-slip alarm condition" -- #TYPE "Alarm - NXeBase Clock Slip" -- #SUMMARY "NXeBase 10001: Clock-slip alarm condition. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10001 adTSUNXeBasePllAlarm TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase is in a PLL alarm condition" -- #TYPE "Alarm - NXeBase PLL Alarm" -- #SUMMARY "NXeBase 10002: PLL alarm condition. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10002 adTSUNXeBaseZeroAlarm TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "An excessive number of consecutive zeros have been detected from the DTE. " -- #TYPE "Alarm - NXeBase Zero Alarm" -- #SUMMARY "NXeBase 10003: Zero alarm condition. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY WARNING -- #GENERIC 6 -- #CATEGORY "Threshold Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10003 adTSUNXeBaseExternClockAlarm TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase is not receiving a valid clock signal from the DTE. " -- #TYPE "Alarm - NXeBase External Clock Alarm" -- #SUMMARY "NXeBase 10004: External Clock Alarm " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10004 adTSUNXeBaseLost TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase has been removed from the chassis or that the card has failed. " -- #TYPE "Alarm - NXeBase Card Not Responding " -- #SUMMARY "NXeBase 10015: NXeBase is not responding " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10015 adTSUNXeBaseClockSlipClear TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase is no longer in a clock-slip alarm condition" -- #TYPE "Alarm - NXeBase Clock Slip Clear" -- #SUMMARY "NXeBase 10017: Clock-slip alarm cleared. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10017 adTSUNXeBasePllAlarmClear TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase is no longer in a PLL alarm condition" -- #TYPE "Alarm - NXeBase PLL Alarm Clear" -- #SUMMARY "NXeBase 10018: PLL alarm cleared. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10018 adTSUNXeBaseZeroAlarmClear TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase is no longer in a Zero Alarm condition" -- #TYPE "Alarm - NXeBase Zero Alarm Clear" -- #SUMMARY "NXeBase 10019: Zero alarm cleared. " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY WARNING -- #GENERIC 6 -- #CATEGORY "Threshold Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10019 adTSUNXeBaseExternClockAlarmClear TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase is now receiving a valid clock signal from the DTE. " -- #TYPE "Alarm - NXeBase External Clock Alarm Clear" -- #SUMMARY "NXeBase 10020: External Clock Alarm cleared " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10020 adTSUNXeBaseFound TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that an NXeBase has been found in the TSU-XX0. " -- #TYPE "Alarm - NXeBase Card Found " -- #SUMMARY "NXeBase 10031: NXeBase card has been found " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY MAJOR -- #GENERIC 6 -- #CATEGORY "Error Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10031 adTSUNXeBaseDteLocalLoopup TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase's DTE interface has been looped-up (bilateral loopback) from a local source. " -- #TYPE "Status - NXeBase DTE Interface Local Loop-up" -- #SUMMARY "NXeBase 10033: DTE inteface locally looped-up " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10033 adTSUNXeBaseDteRemoteLoopup TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase's DTE interface has been looped-up (bilateral loopback) from a remote source. " -- #TYPE "Status - NXeBase DTE Interface Remote Loop-up" -- #SUMMARY "NXeBase 10034: DTE inteface remotely looped-up " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10034 adTSUNXeBase511On TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase is sending 511 pattern towards the network. " -- #TYPE "Status - Nx 511 Pattern On" -- #SUMMARY "NXeBase 10035: NXeBase 511 pattern on " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10035 adTSUNXeBaseLoopup TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase's interface has been looped-up (bilateral loopback). " -- #TYPE "Status - NXeBase Interface Loop-up" -- #SUMMARY "NXeBase 10037: NxBase inteface looped-up " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10037 adTSUNXeBaseDteLocalLoopdown TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase's DTE interface has been looped-down (bilateral loopback) from a local source. " -- #TYPE "Status - NXeBase DTE Interface Loop-down " -- #SUMMARY "NXeBase 10049: DTE interface locally looped-down " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10049 adTSUNXeBaseDteRemoteLoopdown TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase's DTE interface has been looped-down (bilateral loopback) from a remote source. " -- #TYPE "Status - NXeBase DTE Interface Remote Loop-down " -- #SUMMARY "NXeBase 10050: DTE interface remotely looped-down " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10050 adTSUNXeBase511Off TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase is no longer sending 511 pattern towards the network. " -- #TYPE "Status - Nx 511 Pattern Off" -- #SUMMARY "NXeBase 10051: NXeBase 511 pattern off " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10051 adTSUNXeBaseLoopdown TRAP-TYPE ENTERPRISE adTSUNXeBase VARIABLES { ifIndex, adProdPhysAddress, dsx1LineStatus } DESCRIPTION "Indicates that the NXeBase's interface has been looped-down. " -- #TYPE "Status - NXeBase Interface Loop-down" -- #SUMMARY "NXeBase 10053: DBU inteface looped-down " -- #SUMMARY "Unit Name: $C, Interface: %d, Unit Id: %x" -- #ARGUMENTS {0,1} -- #SEVERITY INFORMATIONAL -- #GENERIC 6 -- #CATEGORY "Status Events" -- #SOURCE_ID "A" -- #TIMEINDEX 0 ::= 10053 END