--================================================================== -- Copyright (C) 2006 by HUAWEI TECHNOLOGIES. All rights reserved. -- -- Description: HUAWEI DATASYNC MIB -- Reference: -- Version: V1.0 -- History: -- , , -- fengchong 2009-03-17 -- ================================================================== -- ================================================================== -- -- Variables and types are imported -- -- ================================================================== HUAWEI-DATASYNC-MIB DEFINITIONS ::= BEGIN IMPORTS hwDatacomm FROM HUAWEI-MIB OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP FROM SNMPv2-CONF TimeTicks, Integer32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI RowStatus, TEXTUAL-CONVENTION FROM SNMPv2-TC; hwDataSync MODULE-IDENTITY LAST-UPDATED "200903171027Z" ORGANIZATION "Huawei Technologies Co.,Ltd." CONTACT-INFO "VRP Team Huawei Technologies Co.,Ltd. Huawei Bld.,NO.3 Xinxi Rd., Shang-Di Information Industry Base, Hai-Dian District Beijing P.R. China http://www.huawei.com Zip:100085 " DESCRIPTION "The MIB module for Data sync between host and netmanager." REVISION "200903171027Z" DESCRIPTION "The initial revision of this MIB module ." ::= { hwDatacomm 191 } DateAndTime ::= TEXTUAL-CONVENTION DISPLAY-HINT "2d-1d-1d,1d:1d:1d.1d,1a1d:1d" STATUS current DESCRIPTION "A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present." SYNTAX OCTET STRING (SIZE (8 | 11)) -- -- Node definitions -- -- ================================================================== -- -- ======================= definition begin ========================= -- -- ================================================================== hwDataSyncScalarObjects OBJECT IDENTIFIER ::= { hwDataSync 1 } hwDataSyncTableObjects OBJECT IDENTIFIER ::= { hwDataSync 2 } hwDataSyncNotifications OBJECT IDENTIFIER ::= { hwDataSync 3 } hwCurrentCfgChgSeqID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the ID of the current configuration change. The value ranges from 0 to 65535. After the ID of the configuration change reaches the maximum value, the value of the ID starts from 1 again. After the device is restarted, the value of the ID becomes 0." ::= { hwDataSyncScalarObjects 1 } hwCfgChgSeqIDReveralCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the alarm ID. The value ranges from 0 to 65535." ::= { hwDataSyncScalarObjects 2 } hwCfgChgTableMaxItem OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the maximum number of entries in hwCfgChgTable. The value ranges from 0 to 65535." ::= { hwDataSyncScalarObjects 3 } hwCfgChgTable OBJECT-TYPE SYNTAX SEQUENCE OF HwCfgChgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to record configuration changes. In this table, you can find the configuration change based on the specific index." ::= { hwDataSyncTableObjects 1 } hwCfgChgEntry OBJECT-TYPE SYNTAX HwCfgChgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hwCfgChgTable." INDEX { hwCfgChgSeqID } ::= { hwCfgChgTable 1 } HwCfgChgEntry::= SEQUENCE { hwCfgChgSeqID Integer32, hwCfgChgTime DateAndTime, hwCfgChgTerminalType INTEGER, hwCfgChgTerminalID Integer32, hwCfgChgType INTEGER, hwCfgChgViewName OCTET STRING, hwCfgChgCmdID Integer32, hwCfgChgDetailInfo OCTET STRING } hwCfgChgSeqID OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the configuration change ID. When configuration is changed, the sequence id will plus 1." ::= { hwCfgChgEntry 1 } hwCfgChgTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the configuration change time." ::= { hwCfgChgEntry 2 } hwCfgChgTerminalType OBJECT-TYPE SYNTAX INTEGER {snmp(1),telnet(2),netconf(3)} MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the type of the terminal." ::= { hwCfgChgEntry 3 } hwCfgChgTerminalID OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the terminal ID." ::= { hwCfgChgEntry 4 } hwCfgChgType OBJECT-TYPE SYNTAX INTEGER {create(1),modify(2),delete(3)} MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the configuration change type." ::= { hwCfgChgEntry 5 } hwCfgChgViewName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the name of the view in which the configuration change occurs. For the command operation, the object is the name of the view in which the command is run. For the SNMP operation, the object is the OID of the MIB table or the scalar object." ::= { hwCfgChgEntry 6 } hwCfgChgCmdID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the ID of the configuration change command. For the SNMP operation, the value is 0." ::= { hwCfgChgEntry 7 } hwCfgChgDetailInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates detailed configuration change information. For the command operation, the object is the command line. For the SNMP operation, the object is the index of the MIB table. When there are multiple indexes, the format of index1.index2.index3 is adopted." ::= { hwCfgChgEntry 8 } hwCollectTable OBJECT-TYPE SYNTAX SEQUENCE OF HwCollectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to enable the NMS to send the collecting script to the device to trigger the collection, and then monitor the collection status." ::= { hwDataSyncTableObjects 2 } hwCollectEntry OBJECT-TYPE SYNTAX HwCollectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hwCollectTable." INDEX { hwCollectIndex } ::= { hwCollectTable 1 } HwCollectEntry ::= SEQUENCE { hwCollectIndex Integer32, hwCollectNetManageId Integer32, hwCollectOperation INTEGER, hwCollectInScriptFile OCTET STRING, hwCollectInResultFile OCTET STRING, hwCollectState INTEGER, hwCollectRowStatus RowStatus } hwCollectIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object identifies the collection index." ::= { hwCollectEntry 1 } hwCollectNetManageId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object identifies the NMS ID." ::= { hwCollectEntry 2 } hwCollectOperation OBJECT-TYPE SYNTAX INTEGER {begin(1),stop(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the instruction for the collection operation. Default value is stop." ::= { hwCollectEntry 3 } hwCollectInScriptFile OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the name of the script file. T he length of the file name ranges from 1 character to 255 characters." ::= { hwCollectEntry 4 } hwCollectInResultFile OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the name of the result file. The length of the file name ranges from 1 character to 255 characters." ::= { hwCollectEntry 5 } hwCollectState OBJECT-TYPE SYNTAX INTEGER {idle(1),collecting(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the collection status." ::= { hwCollectEntry 6 } hwCollectRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the row status." ::= { hwCollectEntry 7 } hwCfgChgNotify NOTIFICATION-TYPE OBJECTS {hwCurrentCfgChgSeqID, hwCfgChgSeqIDReveralCount,hwCfgChgTableMaxItem } STATUS current DESCRIPTION "This trap is generated when a configuration change occurs on the device within a specified period." ::= { hwDataSyncNotifications 1 } END -- -- HUAWEI-BULKSTAT-MIB.mib --