-- ============================================================================ -- Copyright (C) 2011 by HUAWEI TECHNOLOGIES. All rights reserved. -- -- Description: -- Reference: -- Version: V1.0 -- History: -- ============================================================================ HUAWEI-ENT-VOICE-PUBLIC-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, private, Integer32, Unsigned32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF TEXTUAL-CONVENTION FROM SNMPv2-TC IpAddress, TimeTicks, Counter32 FROM SNMPv2-SMI RowStatus, DisplayString FROM SNMPv2-TC hwDatacomm FROM HUAWEI-MIB; hwEntVoicePublicMIB MODULE-IDENTITY LAST-UPDATED "201107010000Z" ORGANIZATION "Huawei Technologies Co., Ltd." CONTACT-INFO "Huawei Longgang Production Base, Shenzhen, P.R.C. http://www.huawei.com Zip: 518129" DESCRIPTION "Huawei VOICE PUBLIC mib." -- Revision history REVISION "201107010000Z" DESCRIPTION "V1.0, create this file." ::= { hwDatacomm 249 } -- hwEntSysParaConfigTable hwEntSysParaConfigTable OBJECT IDENTIFIER ::= { hwEntVoicePublicMIB 1 } hwEntSysParaCountry OBJECT-TYPE SYNTAX INTEGER { chinaMainland(1), chinaHongkong(2), brazil(3), egypt(4), singapore(5), thailand(6), france(7), britainMsfuk(8), britainEtsi(9), bulgaria(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of country. Options: chinaMainland(1) - China mainland chinaHongkong(2) - China Hongkong brazil(3) - Brazil egypt(4) - Egypt singapore(5) - Singapore thailand(6) - Thailand france(7) - France britainMsfuk(8) - Britain msfuk britainEtsi(9) - Britain etsi bulgaria(10) - Bulgaria Default: chinaMainland(1)" ::= { hwEntSysParaConfigTable 1 } hwEntSysParaStopInitialRing OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of stop initial ring switch. Options: enable(1) - enable disable(2) - disable Default: enable(1)" ::= { hwEntSysParaConfigTable 2 } hwEntSysParaMwiMode OBJECT-TYPE SYNTAX INTEGER { highVoltage(1), fskWithRing(2), fskWithoutRing(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of mwi mode. Options: highVoltage(1) - high voltage fskWithRing(2) - fsk with ring fskWithoutRing(3) - fsk without ring Default: fskWithRing(2)" ::= { hwEntSysParaConfigTable 3 } hwEntSysParaFlashHookUpper OBJECT-TYPE SYNTAX Integer32 (50..1400) MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of hooking upper threshold. (Unit: ms) Default: 350" ::= { hwEntSysParaConfigTable 4 } hwEntSysParaFlashHookLower OBJECT-TYPE SYNTAX Integer32 (50..1400) MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of hooking lower threshold. (Unit: ms) Default: 100" ::= { hwEntSysParaConfigTable 5 } hwEntSysParaParkFeed OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of park feed switch. Options: enable(1) - enable disable(2) - disable Default: enable(1)" ::= { hwEntSysParaConfigTable 6 } hwEntSysParaPcm OBJECT-TYPE SYNTAX INTEGER {aLaw(1),uLaw(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of PCM. Options: aLaw(1) - a law uLaw(2) - u law Default: aLaw(1)" ::= { hwEntSysParaConfigTable 7 } hwEntSysParaRingFrequency OBJECT-TYPE SYNTAX INTEGER {frequency16HZ(1),frequency25HZ(2),frequency50HZ(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of ring frequency. Options: frequency16HZ(1) - 16HZ frequency25HZ(2) - 25HZ frequency50HZ(3) - 50HZ Default: frequency25HZ(2)" ::= { hwEntSysParaConfigTable 8 } hwEntSysParaRingAcAmplitude OBJECT-TYPE SYNTAX INTEGER { ac65Vrms(1), ac50Vrms(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of ring ac-amplitude. Options: ac65Vrms(1) - 65Vrms ac50Vrms(2) - 50Vrms Default: ac50Vrms(2)" ::= { hwEntSysParaConfigTable 9 } hwEntSysParaGlobalDigitmap OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of global digitmap. Options: enable(1) - enable disable(2) - disable Default: enable(1)" ::= { hwEntSysParaConfigTable 10 } hwEntSysParaSctpSendChecksum OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of sctp send checksum. Options: enable(1) - enable disable(2) - disable Default: enable(1)" ::= { hwEntSysParaConfigTable 11 } hwEntSysParaSctpReceiveChecksum OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "System parameter of sctp receive checksum. Options: enable(1) - enable disable(2) - disable Default: enable(1)" ::= { hwEntSysParaConfigTable 12 } -- IP address configuration table hwEntVoipAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF HwEntVoipAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "VOIP multiply IP table. The index of this table is hwEntVoipAddressIndex" ::= { hwEntVoicePublicMIB 2 } hwEntVoipAddressEntry OBJECT-TYPE SYNTAX HwEntVoipAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "VOIP multiply IP table. The index of this entry is hwEntVoipAddressIndex" INDEX { hwEntVoipAddressIndex } ::= { hwEntVoipAddressTable 1 } HwEntVoipAddressEntry ::= SEQUENCE { hwEntVoipAddressIndex Integer32, hwEntVoipAddressType INTEGER, hwEntVoipInterfaceType DisplayString, hwEntVoipInterfaceId DisplayString, hwEntVoipMethod INTEGER, hwEntVoipIPAddress IpAddress, hwEntVoipAddressRowStatus RowStatus } hwEntVoipAddressIndex OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of VOIP address" ::= { hwEntVoipAddressEntry 1 } hwEntVoipAddressType OBJECT-TYPE SYNTAX INTEGER { signalling(1), media(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The type of VOIP address. Options: signalling(1) - indicates that the type of VOIP IP is signaling. media(2) - indicates that the type of VOIP IP is media." ::= { hwEntVoipAddressEntry 2 } hwEntVoipInterfaceType OBJECT-TYPE SYNTAX DisplayString(SIZE (0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "The interface type of VOIP address." ::= { hwEntVoipAddressEntry 3 } hwEntVoipInterfaceId OBJECT-TYPE SYNTAX DisplayString(SIZE (0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "The interface ID of VOIP address." ::= { hwEntVoipAddressEntry 4 } hwEntVoipMethod OBJECT-TYPE SYNTAX INTEGER { static(1), dynamic(2)} MAX-ACCESS read-create STATUS current DESCRIPTION "Static IP address or dynamic IP address name. Options: static(1) - the IP address is configured statically. dynamic(2) - the IP address is obtained dynamically." ::= { hwEntVoipAddressEntry 5 } hwEntVoipIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IP address." ::= { hwEntVoipAddressEntry 6 } hwEntVoipAddressRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the status of this conceptual row. Options: active(1) createAndGo(4) destroy(6)" ::= { hwEntVoipAddressEntry 7 } END