-- -- IRT4006DDA-MIB.my (MIB for DDA-4006 and DDA-4007) -- v1.0 16/11/2004 -- - Original Issue. -- IRT4006DDA-MIB DEFINITIONS ::= BEGIN IMPORTS irtProducts, irt FROM IRT-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 sysObjectID, sysName FROM RFC1213-MIB; -- -- Node definitions -- -- 1.3.6.1.4.1.16557.3.10 irt4006DDA OBJECT IDENTIFIER ::= { irtProducts 10 } -- 1.3.6.1.4.1.16557.3.10.1 irt4006Alarms OBJECT-TYPE SYNTAX INTEGER { noAlarms(1), urgentAlarms(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the Urgent Alarm." ::= { irt4006DDA 1 } -- 1.3.6.1.4.1.16557.3.10.2 irt4006InputPresent OBJECT-TYPE SYNTAX INTEGER { notPresent(1), present(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that an input signal is present." ::= { irt4006DDA 2 } -- 1.3.6.1.4.1.16557.3.10.3 irt4006Reset OBJECT-TYPE SYNTAX INTEGER (2) ACCESS read-write STATUS mandatory DESCRIPTION "Writing a 2 to this object will cause the agent to reset." ::= { irt4006DDA 3 } -- 1.3.6.1.4.1.16557.3.10.4 irt4006Trap OBJECT-TYPE SYNTAX INTEGER { onAlarm(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, Traps will be sent when an Urgent Alarm occurs Traps will also be sent when the alarm condition ceases." ::= { irt4006DDA 4 } -- -- Trap definitions -- irt4006onAlarmTrap TRAP-TYPE ENTERPRISE irt VARIABLES { sysObjectID, sysName, irt4006Alarms } DESCRIPTION "If enabled, this Trap will be sent when an Urgent Alarm occurs." ::= 10 irt4006offAlarmTrap TRAP-TYPE ENTERPRISE irt VARIABLES { sysObjectID, sysName, irt4006Alarms } DESCRIPTION "If enabled, this trap will be sent when the Alarm restores." ::= 138 END -- -- IRT4006DDA-MIB.my --