-- -- IRT4490MDD-MIB.my (MIB for MDD-4490) -- v1.0 18/01/2006 -- - Original Issue. -- IRT4490MDD-MIB DEFINITIONS ::= BEGIN IMPORTS irtProducts, irt FROM IRT-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 sysObjectID, sysName, DisplayString FROM RFC1213-MIB; -- -- Node definitions -- -- 1.3.6.1.4.1.16557.3.3 irt4490MDD OBJECT IDENTIFIER ::= { irtProducts 3 } -- 1.3.6.1.4.1.16557.3.3.1 irt4490Alarms OBJECT-TYPE SYNTAX INTEGER { noAlarms(1), urgentAlarm(2), nonUrgentAlarm(3), urgAndNonUrgentAlarm(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the Urgent and Non Urgent alarms." ::= { irt4490MDD 1 } -- 1.3.6.1.4.1.16557.3.3.2 irt4490Status OBJECT IDENTIFIER ::= { irt4490MDD 2 } -- 1.3.6.1.4.1.16557.3.3.2.1 irt4490AInputPresent OBJECT-TYPE SYNTAX INTEGER { notPresent(1), present(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that the ASI input signal is present." ::= { irt4490Status 1 } -- -- 1.3.6.1.4.1.16557.3.3.2.2 irt4490SID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Stream Identification of the current input signal" ::= { irt4490Status 2 } -- -- 1.3.6.1.4.1.16557.3.3.2.3 irt4490PATok OBJECT-TYPE SYNTAX INTEGER { ok(1), notOK(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that the PAT is present." ::= { irt4490Status 3 } -- -- 1.3.6.1.4.1.16557.3.3.2.4 irt4490PMTok OBJECT-TYPE SYNTAX INTEGER { ok(1), notOK(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that the PMT is present." ::= { irt4490Status 4 } -- -- 1.3.6.1.4.1.16557.3.3.2.5 irt4490PCRok OBJECT-TYPE SYNTAX INTEGER { ok(1), notOK(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that the PCR is present." ::= { irt4490Status 5 } -- -- 1.3.6.1.4.1.16557.3.3.2.6 irt4490SIDok OBJECT-TYPE SYNTAX INTEGER { matches(1), doesNotMatch(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that the Stream ID of the incoming signal matches that set on the local SID switches" ::= { irt4490Status 6 } -- . -- 1.3.6.1.4.1.16557.3.3.2.7 irt4490PGMok OBJECT-TYPE SYNTAX INTEGER { ok(1), notOK(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that a Program with the number that is set on the local Program Switches is present in the input stream." ::= { irt4490Status 7 } -- 1.3.6.1.4.1.16557.3.3.2.8 irt4490CONTok OBJECT-TYPE SYNTAX INTEGER { ok(1), notOk(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that a continuity count error has occured." ::= { irt4490Status 8 } -- 1.3.6.1.4.1.16557.3.3.2.9 irt4490PktSize OBJECT-TYPE SYNTAX INTEGER { pkt204(1), pkt188(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the number of bytes in a packet." ::= { irt4490Status 9 } -- 1.3.6.1.4.1.16557.3.3.2.10 irt4490PktMode OBJECT-TYPE SYNTAX INTEGER { burstMode(1), distributedMode(2) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication that the Packet is Burst mode or Distributed Mode." ::= { irt4490Status 10 } -- 1.3.6.1.4.1.16557.3.3.3 irt4490Config OBJECT IDENTIFIER ::= { irt4490MDD 3 } -- -- 1.3.6.1.4.1.16557.3.3.3.1 irt4490SIDswitch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The setting of the switches to which the incoming Stream ID will be compared." ::= { irt4490Config 1 } -- -- 1.3.6.1.4.1.16557.3.3.3.2 irt4490PGMswitch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The setting of the switches to which the Program Number will be compared." ::= { irt4490Config 2 } -- -- 1.3.6.1.4.1.16557.3.3.3.3 irt4490URGswitch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The monitored states that can cause an Urgent Alarm to be raised.There are eight conditions and each is assigned a value as follows : 1 PAT Program Association Table Error 2 SID Stream Identification Error 4 PMT Program Map Table Error 8 PGM Program Number Missing 16 PCR Program Clock Reference missing 32 204 Packet Byte Count 64 ASI Input Signal Failure 128 CNT Continuity Counter Violation The number transmitted is the sum of all the values that are selected." ::= { irt4490Config 3 } -- 1.3.6.1.4.1.16557.3.3.3.4 irt4490NURGswitch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The monitored states that can cause a Non Urgent Alarm to be raised.There are eight conditions and each is assigned a value as follows : 1 PAT Program Association Table Error 2 SID Stream Identification Error 4 PMT Program Map Table Error 8 PGM Program Number Missing 16 PCR Program Clock Reference missing 32 204 Packet Byte Count 64 ASI Input Signal Failure 128 CNT Continuity Counter Violation The number transmitted is the sum of all the values that are selected." ::= { irt4490Config 4 } -- 1.3.6.1.4.1.16557.3.3.3.5 irt4490Trap OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If enabled, Traps will be sent when an Urgent or NonUrgent Alarm occurs." ::= { irt4490Config 5 } -- 1.3.6.1.4.1.16557.3.3.3.6 irt4490Reset OBJECT-TYPE SYNTAX INTEGER { reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Writing a 2 to this object will cause the agent to reset." ::= { irt4490Config 6 } -- 1.3.6.1.4.1.16557.3.3.4 irt4490FpgaVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The software version of the FPGA in the format 'x.y', where x is the major revision number and y is the minor revision." ::= { irt4490MDD 4 } -- 1.3.6.1.4.1.16557.3.3.5 irt4490AlarmSource OBJECT-TYPE SYNTAX INTEGER { pat(1), streamID(2), pmt(4), programNo(8), pcr(16), packet204byte(32), inputLoss(64), continuityCount(127) } ACCESS read-only STATUS mandatory DESCRIPTION "The source of the alarm that has caused the trap." ::= { irt4490MDD 5 } -- 1.3.6.1.4.1.16557.3.3.6 irt4490TrapSeqNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A number that increases by one for every trap sent." ::= { irt4490MDD 6 } -- -- Trap definitions -- irt4490UrgAlarmOnTrap TRAP-TYPE ENTERPRISE irt VARIABLES { sysObjectID, sysName, irt4490AlarmSource, irt4490TrapSeqNo } DESCRIPTION "If enabled, traps will be sent when an Urgent alarm occurs." ::= 3 irt4490UrgAlarmOffTrap TRAP-TYPE ENTERPRISE irt VARIABLES { sysObjectID, sysName, irt4490AlarmSource, irt4490TrapSeqNo } DESCRIPTION "If enabled, an trap will be sent when an Urgent Alarm restores." ::= 131 irt4490NonUrgAlarmOnTrap TRAP-TYPE ENTERPRISE irt VARIABLES { sysObjectID, sysName, irt4490AlarmSource, irt4490TrapSeqNo } DESCRIPTION "If enabled, traps will be sent when an Non Urgent alarm occurs." ::= 259 irt4490NonUrgAlarmOffTrap TRAP-TYPE ENTERPRISE irt VARIABLES { sysObjectID, sysName, irt4490AlarmSource, irt4490TrapSeqNo } DESCRIPTION "If enabled, an trap will be sent when a Non Urgent Alarm restores." ::= 387 END -- -- IRT4490MDD-MIB.my --