-- Do not edit this file. -- It is generated automatically by mib-expand -- from ascend.mib.in and *.mibdef. -- Ascend Enterprise MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1997 Ascend Communications, Inc. -- All rights reserved. -- -- CVS ID: $Id: ascend.mib.in,v 29.1.6.2 1999/08/09 21:59:59 ama Exp $ -- -- 01 Dec 93: Initial release -- 18 Aug 94: Added status and console groups -- 22 Mar 95: Added systemStatus, event, callStatus, and sessionStatus groups -- 13 Apr 95: Shortened some object names to under 32 chars. -- 15 Aug 95: rc Added eventDisconnectReason, eventConnectProgress, and -- baudRateChanged(6). -- 28 Aug 95: rc Added serviceModem(37) to hostStatusDataSvc. -- 07 Sep 95: rc Added sysMibVersionNum, sysMibMinorRevNum, and radiusGroup. -- 07 Nov 95: rc Added pppCloseNoNcpsOpened(47), pppCloseUnknownMpBundle(48), -- pppCloseMpAddChanFail(49). -- 16 Nov 95: rc Added prIPXNCPOpened(80). -- 18 Dec 95: rc Added virtualConnect(16), prModemOutdialCallUp(50), -- tsClosedVirtualConnect(29), tsVirtualConnectDestroyed(30). -- 29 Jan 95: Added additional enums to eventDisconnectReason -- 12 Jan 96: les Added eventCallCharge. -- 18 Jan 96: les Added eventCalledPartyID, eventCallingPartyID, -- eventInOctets, eventOutOctets. -- 14 Feb 96: rc Added requestByRadiusClient(150). -- 20 Apr 96: kh Added radAuthHostIPAddress, radAuthCurrentServerFlag, -- radAcctHostIPAddress and radAcctCurrentServerFlag. -- 23 Apr 96: kh changed radius CurrentServerFlag's to read-write in -- order to allow user to select current server. -- 13 Jun 96: cag Added sysConfigTftpCmd options 3, 4 & 5. -- 14 Jun 96: cag Added product subcategory information to define MAX/PIPE -- models returned by sysObjectID. -- 18 Sep 96: pj Added mCastGroup -- 27 Sep 96: cag Added sysConfigTftpCmd option 6: load code. -- 15 Oct 96: kh Added prBACPOpening and prBACPOpened -- 17 Oct 96: rm Added callStatusType in the callStatusTable -- 17 Oct 96: rm Added the lanModemGroup -- 25 Oct 96: rm Added eventCurrentActiveCalls, .... -- 29 Oct 96: rm Added eventMultiLinkID -- 06 Nov 96: rm Added busyLanModem, busyLanModemTable sub-group, suspectTrapState -- 05 Dec 96: rm Added call[Current|Total][Analog|Digital|FrameRelay][Outgoing|Incoming] -- 26 Dec 96: rm Added sysAbsoluteCurrentTime read-write variable -- 07 Jan 97: rm Added slotMdmItemStatus and slotMdmItemStatusChar -- 15 Jan 97: rm Added sessionActiveTable -- 16 Jan 97: rm Defined new slotType values for TNT -- 22 Jan 97: rm Added sysReset -- 28 Jan 97: rm Added callActiveTable -- 07 Feb 97: rm Added sysLoadName -- 22 Mar 97: jh Added sysAuthPreference -- 19 Feb 97: dl Added mppActiveStatsTable -- 20 Feb 97: rm Added mechanism to kill sessions -- 21 Feb 97: rm Commented ranges as SunNet Manager does not like it! -- 11 Mar 97: rm separated the eventGroup, callStatusGroup, sessionStatusGroup, -- lanModemGroup, radiusGroup, mCastGroup, slotMdmTable -- Refer to event.mib, call.mib, session.mib lmodem.mib, -- radius.mib mcast.mib -- 02 Apr 97: lcs Refer to firewall.mib, -- add firewallGroup ::= { ascend 16 } -- 16 Apr 97: dba Added additional enums to eventDisconnectReason -- 23 Apr 97: rm Added sysProm subgroup -- 07 Jul 97: rm Added wanDialoutPkt subgroup -- 01 Aug 97: rm Added powerSupply subgroup -- 04 Aug 97: rm Added multiShelf subgroup -- 28 Aug 97: rm Created advancedAgent -- 02 Oct 97: kn EOI-12553: Back out the changes made on 8/28/97 and -- rename wanInfo to adavancedAgent -- 21 Jan 98: rm Added sysLastRestartReason -- 02 Feb 98: kn Added sysOID for DSLPipe products -- 09 Feb 98: kn Added sysOID for dslTnt and Pipeline85 -- 11 Feb 98: kn Added sysOID for Pipeline50LS56 -- 07 Apr 98: kc Added additional enums to eventDisconnectReason -- 21 Apr 98: hcl Added 2 enums to sysConfigTftpCmd and created -- sysConfigTftpParameter -- 26 May 98 aq Added flashGroup -- 28 May 98 aq Added asgGroup per kn request. -- 12 Jun 98 aq Added configuration per kn request. -- 16 Jun 98 mb Added Call Logging Group -- 18 Jun 98 kn Added atmpGroup -- 19 Jun 98 mb Added new sysOID for pipe130 series. -- 19 Jun 98 aq Added srvcMgmt group for dnis management. -- 04 Sep 98 djl Added sysConfigChange. -- 04 Nov 98 se Added sysOID for DMT pipes -- 06 Nov 98 mk Transfer slot, item and slotIf MIBs to chassis.mib -- 20 Nov 98 kn Added resourceGroup. -- 20 Jan 98 kv Added sysConfigFlash -- 11 Mar 99 ane Added sysOID for AQ products and AQ300 -- 12 Mar 99 mk Corrected spell err in the sysConfigRadiusCmd. -- 18 Mar 99 rvg Added sysOID for spipe155 and spipe95. -- 26 Mar 99 ryu Added sysOID for ST100 platform: dslmax20 and terminator. -- 10 Jun 99 aks Added fatalLogTable. -- 25 Jul 99 ama Changed sysAbsoluteStartupTime, sysAbsoluteCurrentTime, -- sysSecsSinceStartup SYNTAX to TimeTicks ASCEND-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, TimeTicks FROM RFC1155-SMI IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- -- The Ascend Communications enterprise OID. -- ascend OBJECT IDENTIFIER ::= { enterprises 529 } -- -- Groups in the Ascend Enterprise mib -- products OBJECT IDENTIFIER ::= { ascend 1 } slots OBJECT IDENTIFIER ::= { ascend 2 } hostTypes OBJECT IDENTIFIER ::= { ascend 3 } advancedAgent OBJECT IDENTIFIER ::= { ascend 4 } lanTypes OBJECT IDENTIFIER ::= { ascend 5 } doGroup OBJECT IDENTIFIER ::= { ascend 6 } hostStatus OBJECT IDENTIFIER ::= { ascend 7 } console OBJECT IDENTIFIER ::= { ascend 8 } systemStatusGroup OBJECT IDENTIFIER ::= { ascend 9 } eventGroup OBJECT IDENTIFIER ::= { ascend 10 } callStatusGroup OBJECT IDENTIFIER ::= { ascend 11 } sessionStatusGroup OBJECT IDENTIFIER ::= { ascend 12 } radiusGroup OBJECT IDENTIFIER ::= { ascend 13 } mCastGroup OBJECT IDENTIFIER ::= { ascend 14 } lanModemGroup OBJECT IDENTIFIER ::= { ascend 15 } firewallGroup OBJECT IDENTIFIER ::= { ascend 16 } wanDialoutPkt OBJECT IDENTIFIER ::= { ascend 17 } powerSupply OBJECT IDENTIFIER ::= { ascend 18 } multiShelf OBJECT IDENTIFIER ::= { ascend 19 } miscGroup OBJECT IDENTIFIER ::= { ascend 20 } asgGroup OBJECT IDENTIFIER ::= { ascend 21 } flashGroup OBJECT IDENTIFIER ::= { ascend 22 } configuration OBJECT IDENTIFIER ::= { ascend 23 } atmpGroup OBJECT IDENTIFIER ::= { ascend 24 } callLoggingGroup OBJECT IDENTIFIER ::= { ascend 25 } srvcMgmtGroup OBJECT IDENTIFIER ::= { ascend 26 } resourcesGroup OBJECT IDENTIFIER ::= { ascend 27 } -- Ascend products. -- -- Each Ascend product family is Assigned an Object Identifier. -- This is the identifier stored in the MIB-II system group -- item sysObjectID to identify the product to a network manager. -- If product family specific items need to be defined they should -- be defined in the appropriate product family subtree multiband OBJECT IDENTIFIER ::= { products 1 } max OBJECT IDENTIFIER ::= { products 2 } pipeline OBJECT IDENTIFIER ::= { products 3 } max-tnt OBJECT IDENTIFIER ::= { products 4 } dslTnt OBJECT IDENTIFIER ::= { products 5 } aqueduct OBJECT IDENTIFIER ::= { products 6 } stinger-10 OBJECT IDENTIFIER ::= { products 7 } -- Ascend max product family. -- -- There are several products in the MAX family. This is the -- identifier that enumerates the individual products. max200 OBJECT IDENTIFIER ::= { max 1 } max1800 OBJECT IDENTIFIER ::= { max 2 } max2000 OBJECT IDENTIFIER ::= { max 3 } max4000 OBJECT IDENTIFIER ::= { max 4 } max4002 OBJECT IDENTIFIER ::= { max 5 } max4004 OBJECT IDENTIFIER ::= { max 6 } max6000 OBJECT IDENTIFIER ::= { max 7 } max800 OBJECT IDENTIFIER ::= { max 8 } max3000 OBJECT IDENTIFIER ::= { max 9 } dslmax20 OBJECT IDENTIFIER ::= { max 10 } terminator OBJECT IDENTIFIER ::= { max 11 } -- Ascend pipeline product family. -- -- There are several products in the PIPELINE family. This is -- the identifier that enumerates the individual products. pipe15 OBJECT IDENTIFIER ::= { pipeline 1 } pipe25 OBJECT IDENTIFIER ::= { pipeline 2 } pipe25Px OBJECT IDENTIFIER ::= { pipeline 3 } pipe25Fx OBJECT IDENTIFIER ::= { pipeline 4 } pipe50 OBJECT IDENTIFIER ::= { pipeline 5 } pipe75 OBJECT IDENTIFIER ::= { pipeline 6 } pipe130T1 OBJECT IDENTIFIER ::= { pipeline 7 } pipe400 OBJECT IDENTIFIER ::= { pipeline 8 } pipe220 OBJECT IDENTIFIER ::= { pipeline 9 } -- sysOID for DSLPipe CPE products in the PIPELINE family dslPipeAcap OBJECT IDENTIFIER ::= { pipeline 10 } dslPipeS OBJECT IDENTIFIER ::= { pipeline 11 } dslPipe2S OBJECT IDENTIFIER ::= { pipeline 12 } dslPipeAdmt OBJECT IDENTIFIER ::= { pipeline 21 } dslPipeAlctlDmt OBJECT IDENTIFIER ::= { pipeline 22 } -- sysOID for DSLPipe COE products in the PIPELINE family dslPipeAdslCoeC OBJECT IDENTIFIER ::= { pipeline 13 } dslPipeSdslCoe OBJECT IDENTIFIER ::= { pipeline 14 } dslPipeSdslCoe2S OBJECT IDENTIFIER ::= { pipeline 15 } dslPipeAdslCoeD OBJECT IDENTIFIER ::= { pipeline 20 } -- sysOID for more Pipeline Products pipe85 OBJECT IDENTIFIER ::= { pipeline 16 } pipe50LS56 OBJECT IDENTIFIER ::= { pipeline 17 } -- sysOID for more Pipeline Products -- Pipeline 130 with V35 interface pipe130V35 OBJECT IDENTIFIER ::= { pipeline 18 } -- Pipeline 130 with Switched 56 interface pipe130N56 OBJECT IDENTIFIER ::= { pipeline 19 } -- Super Pipeline 95 spipe95 OBJECT IDENTIFIER ::= { pipeline 23 } -- Super Pipeline 155 with T1 interface spipe155T1 OBJECT IDENTIFIER ::= { pipeline 24 } -- Ascend max-tnt product family. -- -- There is only a single product in the MAX-TNT family. -- As more products are added future qualification will -- be performed. -- Ascend aqueduct product family. -- -- There is currently only one product in the AQUEDUCT family. -- This is the identifier that enumerates the individual products. aq300 OBJECT IDENTIFIER ::= { aqueduct 1 } -- Ascend stinger-10 product family. -- -- There is only a single product in the stinger-10 family. -- As more products are added future qualification will -- be performed. -- Ascend Host types -- -- Each Ascend host type is assigned an object ID. These ids are -- the root of MIB subtrees containing host specific information. -- These subtrees, when required, are described in separate files. hostTypeAny OBJECT IDENTIFIER ::= { hostTypes 1 } hostTypeDual OBJECT IDENTIFIER ::= { hostTypes 2 } hostTypeQuad OBJECT IDENTIFIER ::= { hostTypes 3 } hostTypeAim2 OBJECT IDENTIFIER ::= { hostTypes 4 } hostTypeAim6 OBJECT IDENTIFIER ::= { hostTypes 5 } -- Ascend LAN types -- -- Each Ascend LAN type is assigned an object ID. These ids are -- the root of MIB subtrees containing LAN specific information. -- These subtrees, when required, are described in separate files. lanTypeAny OBJECT IDENTIFIER ::= { lanTypes 1 } lanTypeEthernet OBJECT IDENTIFIER ::= { lanTypes 2 } lanTypeEtherData OBJECT IDENTIFIER ::= { lanTypes 3 } -- Ascend Do Group -- -- This group implements the Ascend action commands. The action -- is performed on the indicated slot/item. To implement this -- the do commands are treated as a table indexed by slot and item. doTable OBJECT-TYPE SYNTAX SEQUENCE OF DoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of do entries." ::= { doGroup 1 } doEntry OBJECT-TYPE SYNTAX DoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing all of the action (do) commands and the slot and item index." INDEX { doSlotIndex, doItemIndex } ::= { doTable 1 } DoEntry ::= SEQUENCE { doSlotIndex INTEGER, doItemIndex INTEGER, doDial INTEGER, doHangUp INTEGER, doAnswer INTEGER, doExtendBW INTEGER, doContractBW INTEGER, doBegEndRemoteLB INTEGER, doBegEndBERT INTEGER, doResynchronize INTEGER } doSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the slot containing the item for which an action is desired. The valid range is 1 through the value slotNumber." ::= { doEntry 1 } doItemIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The item number on the indexed slot for which an action is desired. The valid range is 1 through the value slotItems in the slotTable when indexed by a value equal to doSlotIndex." ::= { doEntry 2 } doDial OBJECT-TYPE SYNTAX INTEGER { valid( 1 ), notValid( 2 ) } ACCESS read-write STATUS mandatory DESCRIPTION "When read returns valid if the indexed slot/item can dial a call. Writing any value will cause a call to be placed when valid, otherwise the write is ignored." ::= { doEntry 3 } doHangUp OBJECT-TYPE SYNTAX INTEGER { valid( 1 ), notValid( 2 ) } ACCESS read-write STATUS mandatory DESCRIPTION "When read returns valid if the indexed slot/item can terminate a call. Writing any value will cause the call to be terminated when valid, otherwise the write is ignored." ::= { doEntry 4 } doAnswer OBJECT-TYPE SYNTAX INTEGER { valid( 1 ), notValid( 2 ) } ACCESS read-write STATUS mandatory DESCRIPTION "When read returns valid if the indexed slot/item can answer a call. Writing any value will cause the call to be answered when valid, otherwise the write is ignored." ::= { doEntry 5 } doExtendBW OBJECT-TYPE SYNTAX INTEGER { valid( 1 ), notValid( 2 ) } ACCESS read-write STATUS mandatory DESCRIPTION "When read returns valid if the indexed slot/item can extend bandwidth. Writing any value will cause bandwidth to be extended when valid, otherwise the write is ignored." ::= { doEntry 6 } doContractBW OBJECT-TYPE SYNTAX INTEGER { valid( 1 ), notValid( 2 ) } ACCESS read-write STATUS mandatory DESCRIPTION "When read returns valid if the indexed slot/item can contract bandwidth. Writing any value will cause bandwidth to be contracted when valid, otherwise the write is ignored." ::= { doEntry 7 } doBegEndRemoteLB OBJECT-TYPE SYNTAX INTEGER { valid( 1 ), notValid( 2 ) } ACCESS read-write STATUS mandatory DESCRIPTION "When read returns valid if the indexed slot/item can enter or exit remote loopback. Writing any value will cause the current remote loopback state to be toggled when valid, otherwise the write is ignored." ::= { doEntry 8 } doBegEndBERT OBJECT-TYPE SYNTAX INTEGER { valid( 1 ), notValid( 2 ) } ACCESS read-write STATUS mandatory DESCRIPTION "When read returns valid if the indexed slot/item can enter or exit BERT test mode. Writing any value will cause the current BERT test state to be toggled when valid, otherwise the write is ignored." ::= { doEntry 9 } doResynchronize OBJECT-TYPE SYNTAX INTEGER { valid( 1 ), notValid( 2 ) } ACCESS read-write STATUS mandatory DESCRIPTION "When read returns valid if the indexed slot/item can issue a resynchronize command. Writing any value will cause a resynchronize command to be issued when valid, otherwise the write is ignored." ::= { doEntry 10 } -- Ascend Status Group -- -- This group displays the status of a session when indexed by -- slot and item. No such item is returned if the slot/item -- does not reference something that identifies a session. hostStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF HostStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of host port status entries. A host port status entry potentialy exists for every slot/item. Host port status entries are only meaningful for slot/items that reference a host port. When indexed by other slot/items NO SUCH NAME will be returned." ::= { hostStatus 1 } hostStatusEntry OBJECT-TYPE SYNTAX HostStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing the host port status of the indexed slot/item." INDEX { hostStatusSlotIndex, hostStatusItemIndex } ::= { hostStatusTable 1 } HostStatusEntry ::= SEQUENCE { hostStatusSlotIndex INTEGER, hostStatusItemIndex INTEGER, hostStatusLocalName OCTET STRING, hostStatusDialNum OCTET STRING, hostStatusCallType INTEGER, hostStatusCallMgm INTEGER, hostStatusDataSvc INTEGER, hostStatusCallState INTEGER, hostStatusRemName OCTET STRING, hostStatusChannels INTEGER, hostStatusDuration INTEGER } hostStatusSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each slot. The slot identified by a particular value of this index is the same slot as identified by the same value of slotIndex." ::= { hostStatusEntry 1 } hostStatusItemIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index to each item defined for each slot. Since entries in this table are only valid for host ports an item number is a port number within the indexed slot." ::= { hostStatusEntry 2 } hostStatusLocalName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The name from the current call profile of the indexed host slot and port." ::= { hostStatusEntry 3 } hostStatusDialNum OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The phone number from the current call profile of the indexed host slot and port." ::= { hostStatusEntry 4 } hostStatusCallType OBJECT-TYPE SYNTAX INTEGER { aim( 1 ), bonding( 2 ), one-channel( 3 ), two-channel( 4 ), ft1( 5 ), ft1Aim( 6 ), ft1BandO( 7 ) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of call from the current call profile of the indexed host slot and port." ::= { hostStatusEntry 5 } hostStatusCallMgm OBJECT-TYPE SYNTAX INTEGER { none( 1 ), manual( 2 ), static( 3 ), dynamic( 4 ), delta( 5 ), one-of-8( 6 ), one-of-40( 7 ), mode1( 8 ), mode2( 9 ), mode3( 10 ), mode0( 11 ) } ACCESS read-only STATUS mandatory DESCRIPTION "The call management protocol from the current call profile for the indexed host slot and port. Call management is only meaningful for calls using an inverse multiplexing protocol." ::= { hostStatusEntry 6 } hostStatusDataSvc OBJECT-TYPE SYNTAX INTEGER { serviceVoice( 1 ), service56KR( 2 ), service56K( 3 ), service64K( 4 ), service384KR( 5 ), service384K-H0( 6 ), service1536K( 7 ), service1536KR( 8 ), service128K( 9 ), service192K( 10 ), service256K( 11 ), service320K( 12 ), service384K( 13 ), service448K( 14 ), service512K( 15 ), service576K( 16 ), service640K( 17 ), service704K( 18 ), service768K( 19 ), service832K( 20 ), service896K( 21 ), service960K( 22 ), service1024K( 23 ), service1088K( 24 ), service1152K( 25 ), service1216K( 26 ), service1280K( 27 ), service1344K( 28 ), service1408K( 29 ), service1472K( 30 ), service1600K( 31 ), service1664K( 32 ), service1728K( 33 ), service1792K( 34 ), service1856K( 35 ), service1920K( 36 ), serviceModem( 37 ), serviceV110-24-56K( 38 ), serviceV110-48-56K( 39 ), serviceV110-96-56K( 40 ), serviceV110-192-56K( 41 ), serviceV110-384-56K( 42 ), serviceV110-24-56KR( 43 ), serviceV110-48-56KR( 44 ), serviceV110-96-56KR( 45 ), serviceV110-192-56KR( 46 ), serviceV110-384-56KR( 47 ), serviceV110-24-64K( 48 ), serviceV110-48-64K( 49 ), serviceV110-96-64K( 50 ), serviceV110-192-64K( 51 ), serviceV110-384-64K( 52 ), serviceV110-24-64KR( 53 ), serviceV110-48-64KR( 54 ), serviceV110-96-64KR( 55 ), serviceV110-192-64KR( 56 ), serviceV110-384-64KR( 57 ) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of service from the current call profile for the indexed host slot and port." ::= { hostStatusEntry 7 } hostStatusCallState OBJECT-TYPE SYNTAX INTEGER { other( 1 ), answering( 2 ), calling( 3 ), clearing( 4 ), localLoop( 5 ), handshake( 6 ), idle( 7 ), online( 8 ), loopMast( 9 ), loopSlav( 10 ), bertMast( 11 ), bertSlav( 12 ), remoteMg( 13 ), ringing ( 14 ), setupAdd( 15 ), setupHnd( 16 ), setupRem( 17 ) } ACCESS read-only STATUS mandatory DESCRIPTION "Shows the current state of the current call for the indexed host slot and port. The returned value will indicates the same state displayed in a call status window for the port." ::= { hostStatusEntry 8 } hostStatusRemName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The value displayed on the 4th line of the call status menu. When the hostStatusCallType is aim( 1 ) this value is the name of the host port on the far end of a connection, or the far-end system name if the host port has not been named. An empty string is returned when there is no call active or when aim( 1 ) is not being used." ::= { hostStatusEntry 9 } hostStatusChannels OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of channels in use by the call as displayed on the third line of the call status menu for the indexed slot and port." ::= { hostStatusEntry 10 } hostStatusDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The duration of the call associated with the indexed host slot and port, measured in seconds." ::= { hostStatusEntry 11 } -- Ascend Console Group -- -- This group maps the console interfaces to their SNMP interface -- number and points to the appropriate management MIB object -- for the console type. Multiple consoles may exist, e.g -- a palmtop port is a console port. consoleNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of consoles supported by this device." ::= { console 1 } -- The console table -- -- This table contains consoleNumber entries describing each -- console port. consoleTable OBJECT-TYPE SYNTAX SEQUENCE OF ConsoleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of console entries." ::= { console 2 } consoleEntry OBJECT-TYPE SYNTAX ConsoleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects that describe the indexed console port." INDEX { consoleIndex } ::= { consoleTable 1 } ConsoleEntry ::= SEQUENCE { consoleIndex INTEGER, consoleIf INTEGER, consoleType INTEGER, consoleSecurity INTEGER, consoleSpecific OBJECT IDENTIFIER } consoleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each console. It's value ranges between 1 and the value consoleNumber. This is the index into the console table to identify a particular console." ::= { consoleEntry 1 } consoleIf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The interface number associated with the indexed console. This number can be used to index into the interface (and other) tables to obtain detailed console status." ::= { consoleEntry 2 } consoleType OBJECT-TYPE SYNTAX INTEGER { other( 1 ), -- none of the following primary( 2 ), -- Primary VT100 console secondary( 3 ), -- VT100 console in palmtop port palmtop( 4 ), -- palmtop console inactive( 5 ), -- inactive/unused session remote( 6 ) -- active remote session } ACCESS read-only STATUS mandatory DESCRIPTION "The type of console in the indexed entry. When no console is plugged into a console port the value inactive(5) is returned. The value remote(6) indicates a console initiated via remote management or TELNET session." ::= { consoleEntry 3 } consoleSecurity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The security profile, in the range of 1 through the number of profiles supported by the unit, of the indexed console. The default security profile is profile number 1." ::= { consoleEntry 4 } consoleSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "A reference to MIB definitions specific to the console port. Contains the object identifier { 0 0 } if there is no console specific information for the indexed console." ::= { consoleEntry 5 } -- -- Ascend System Status group -- -- This group contains general information regarding the system -- as a whole. This information provided by this group can be -- viewed as an extension of the system group under MIB-II. -- sysAbsoluteStartupTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time system startup up in seconds since January 1, 1990. This value in concert with 'sysSecsSinceStartup' below can be used to compute the current time in seconds since 1/1/90." ::= { systemStatusGroup 1 } sysSecsSinceStartup OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds since system startup." ::= { systemStatusGroup 2 } sysMibVersionNum OBJECT-TYPE -- SYNTAX INTEGER (1..'7fffffff'h) SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Version number of this private MIB. Versions numbers start at 1 and increment by 1 for every major revision. Major revisions are additions/deletions to this MIB." ::= { systemStatusGroup 3 } sysMibMinorRevNum OBJECT-TYPE -- SYNTAX INTEGER (1..'7fffffff'h) SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Value represents the minor revision number of this MIB. Minor revision numbers start at 0 and increment by 1 for each revision. Minor revisions are textual or comment changes." ::= { systemStatusGroup 4 } sysConfigTftp OBJECT IDENTIFIER ::= { systemStatusGroup 5 } sysConfigTftpCmd OBJECT-TYPE SYNTAX INTEGER { save( 1 ), -- save configuration restore( 2 ), -- restore configuration saveAll( 3 ), -- save ALL config options saveMib( 4 ), -- save config w/MIB numbers saveAllMib( 5 ), -- save ALL config w/MIB numbers loadCode( 6 ), -- load a code image saveIncProf( 7 ), -- save specified config saveExcProf( 8 ) -- save All except specified config } ACCESS read-write STATUS mandatory DESCRIPTION "This variable instructs the system to perform the specified tftp operation. Note: loadCode( 6 ) is not supported on TNT platform." ::= { sysConfigTftp 1 } sysConfigTftpStatus OBJECT-TYPE SYNTAX INTEGER { ok( 1 ), -- tftp operation succeeded notFound( 2 ), -- file not found access( 3 ), -- access violation noSpace( 4 ), -- no disk space to write file badOp( 5 ), -- bad tftp operation badTid( 6 ), -- unknown transfer ID exists( 7 ), -- file already exists noSuchUser( 8 ), -- no such user parameter( 9 ), -- parameter error busy( 10 ), -- tftp server cannot handle request noResources( 11 ), -- no memory for request timeout( 12 ), -- timed out unrecoverable( 13 ), -- unrecoverable error tooManyRetries( 14 ), -- too many retries createFile( 15 ), -- create file openFile( 16 ), -- open file inProgress( 17 ) -- get/put request in progress } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the status of a save or restore operation through tftp." ::= { sysConfigTftp 2 } sysConfigTftpHostAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This variable indicates the host address where the configuration file is saved to or restored from through tftp." ::= { sysConfigTftp 3 } sysConfigTftpFilename OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This variable indicates the file name of the configuration file to save to or restore from a SNMP host through tftp." ::= { sysConfigTftp 4 } sysConfigTftpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This variable indicates the port # to use when starting a TSAVE TRESTORE command. Normally this would be port 69, but we need to allow the Java Console to override this in case the Console workstation has a TFTP server already running." ::= { sysConfigTftp 5 } sysConfigTftpParameter OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This variable indicates the list of profiles to be included or excluded during the save operation through tftp." ::= { sysConfigTftp 6 } sysConfigRadius OBJECT IDENTIFIER ::= { systemStatusGroup 6 } sysConfigRadiusCmd OBJECT-TYPE SYNTAX INTEGER { all( 1 ), -- all configuration routes( 2 ), -- bridge/ip/ipx routes configuration pools( 3 ), -- ip address pool configuration nailed( 4 ), -- permanent and nailed configuration termsrv( 5 ) -- term server banners } ACCESS read-write STATUS mandatory DESCRIPTION "This variable instructs the system to re-read its RADIUS configuration. This variable will return a general error if RADIUS is not configured or if sysConfigRadiusStatus has a value of processing(2)." ::= { sysConfigRadius 1 } sysConfigRadiusStatus OBJECT-TYPE SYNTAX INTEGER { init( 1 ), -- configuration has not started processing( 2 ), -- configuration is in progress timeout( 3 ), -- configuration request timed-out error( 4 ), -- configuration received other error complete( 5 ) -- configuration complete sucessfully } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the status of the last RADIUS configuration retrieval. This includes the boot time retrieval." ::= { sysConfigRadius 2 } sysAbsoluteCurrentTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "The current system time in seconds since January 1, 1990. Changing this value may result in a change of sysAbsoluteStartupTime and not of sysSecsSinceStartup. The following relationship holds: sysAbsoluteCurrentTime - sysAbsoluteStartupTime = sysSecsSinceStartup." ::= { systemStatusGroup 7 } sysReset OBJECT-TYPE SYNTAX INTEGER { no-op( 1 ), reset( 2 ) } ACCESS read-write STATUS mandatory DESCRIPTION "The reset takes effect after 1 minute." ::= { systemStatusGroup 8 } sysLoadName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name of the load which is currently running." ::= { systemStatusGroup 9 } sysAuthPreference OBJECT-TYPE SYNTAX INTEGER { no-op(1), local-first(2), remote-first(3), remote-no(4) } ACCESS read-write STATUS mandatory DESCRIPTION "An incoming call can be authenticated using a local profile or one from an authentication server such as RADIUS or TACACS. local-first means authenticate from a local profile first, and if that fails, try the authentication server. remote-first means get a profile from the authentication server and authenticate from that and if that fails, try to authenticate from a local profile. remote-no is the same as remote-first except if the external authentication server NACKs the request, then the connection will be denied, i.e. no search of the local profiles will be made." ::= { systemStatusGroup 10 } -- -- system security PROM subgroup of systemStatusGroup -- sysSPROM OBJECT IDENTIFIER ::= { systemStatusGroup 11 } sysSPROMSerialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number as stored in the security PROM. The same value is also returned as part of sysName." ::= { sysSPROM 1 } sysSPROMOptions1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The various bit positions are: (2 ** 0) - rs366Enabled (2 ** 1) - dChannelEnabled (2 ** 2) - autoDBAEnabled (2 ** 3) - bondingEnabled (2 ** 4) - aimEnabled (2 ** 5) - v25bisEnabled (2 ** 6) - x21Enabled (2 ** 7) - switchedEnabled (2 ** 8) - mrateEnabled (2 ** 9) - pbxEnabled (2 ** 10) - pcbusEnabled (2 ** 11) - bridgingEnabled (2 ** 12) - pipeHxEnabled (2 ** 13) - frameRelayEnabled (2 ** 14) - maxLinkClientEnabled (2 ** 15) - dataCallEnabled (2 ** 16) - dualSlotT1Enabled (2 ** 17) - r2SignalingEnabled (2 ** 18) - domesticEnabled (2 ** 19) - modemTSDialoutEnabled (2 ** 20) - pipePxEnabled (2 ** 21) - firewallsEnabled (2 ** 22) - serialPortT1_CSU_Enabled (2 ** 23) - pipePotsEnabled (2 ** 24) - forceMultibandPlatformSimulationEnabled (2 ** 25) - k56SlotCardOnlyEnabled (2 ** 26) - networkManagementEnabled (2 ** 27) - advancedAgentEnabled (DEPRECATED) (2 ** 28) - phsSupportEnabled (2 ** 29) - selectoolsEnabled (2 ** 30) - routingProtocolsDisabled (2 ** 31) - tunnelProtocolsDisabled (DEPRECATED)." ::= { sysSPROM 2 } sysSPROMOptions2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The various bit positions are: (2 ** 0) - atmpEnabled (2 ** 1) - l2tpEnabled (2 ** 2) - pptpEnabled (2 ** 3) - l2fEnabled (2 ** 4) - ipinipEnabled (2 ** 5) - vRouterEnabled (2 ** 6) - aodiEnabled (2 ** 7) - maddModemEnabled (2 ** 8) - madd96DevicesEnabled (2 ** 9) - maddHdlcEnabled (2 ** 10) - v110Enabled (2 ** 11) - sdtnEnabled (2 ** 12) - restrictDSLTermEnabled (2 ** 13) - megamaxEnabled (2 ** 14) = maxtapEnabled (2 ** 15) - phs21Enabled." ::= { sysSPROM 3 } sysSPROMCountries1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The various bit positions are: (2 ** 0) - FranceIsdn (2 ** 1) - UKIsdn (2 ** 2) - BelgiumIsdn (2 ** 3) - JapanIsdn (2 ** 4) - AustraliaIsdn (2 ** 5) - GermanIsdn (2 ** 6) - UKDpnss (2 ** 7) - SwissIsdn (2 ** 8) - GloBandIsdn " ::= { sysSPROM 4 } resetStat OBJECT IDENTIFIER ::= { systemStatusGroup 12 } resetStatEther OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Clear Ethernet statistics." ::= { resetStat 1 } resetStatWAN OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Clear specified interface's WAN statistics." ::= { resetStat 2 } resetStatAll OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Clear all WAN statistics." ::= { resetStat 3 } sysLastRestartReason OBJECT-TYPE SYNTAX INTEGER { fatalAssert(1), fatalPoolsNoBuffer(2), fatalProfileBad(3), fatalSwitchTypeBad(4), fatalLif(5), fatalLcdError(6), fatalIsacTimeout(7), fatalSCCSpuriousInterrupt(8), -- 8 is a.k.a. PROCESSOR EXCEPTION!! fatalExecInvalidSwitch(9), fatalExecNoMailDesc(10), fatalExecNoMailPoll(11), fatalExecNoTask(12), fatalExecNoTimer(13), fataExecNoTimerPool(14), fatalExecWaitInCtricalSection(15), fatalDspDead(16), fatalDspProtocolError(17), fatalDspInternalError(18), fatalDspLossOfSync(19), fatalDspUnUsed(20), fatalDDDDead(21), fatalDDDProtocolError(22), fatalX25Buffers(23), fatalX25Init(24), fatalX25Stack(25), fatalZeroMemoryAlloc(27), fatalNegativeMemoryAllocate(28), fatalTaskLoop(29), fatalMemcpyTooLarge(30), fatalMemcpyNoMagic(31), fatalMemcpyWrongMagic(32), fatalMemcoyBadStart(33), fatalIDECTimeout(34), fatalExecRestricted(35), fatalStackOverflow(36), fatalDRAMCard(37), fatalMbufPanic(38), fatalNoPriority2Task(39), fatalProtectionFault(40), fatalClipping(41), -- clipping (may indicate memory leak) fatalReadyHangFault(42), fatalExcessPostCompl(43), fatalWriteProtect(44), fatalPureVirtual(45), -- C++ pure virtual call attempted fatalATMSVC(46), fatalFRSVC(47), fatalLinkedListCorruption(55), fatalCardBounced(96), fatalCardDown(97), fatalPrimarySelected(98), fatalOperatorReset(99), fatalSystemUp(100), warningBufferInUse(101), warningBufferWrongPool(102), warningBufferWrongHeap(103), warningBufferNotMemAlloc(104), warningBufferBadMemAlloc(105), warningBufferBogusPool(106), warningBufferBogusHeap(107), warningBufferNegativeMemalloc(108), warningBufferZeroMemalloc(109), warningBufferBoundary(110), warningBufferTooBig(111), warningBufferNull(112), warningBufferSegmentCountZero(113), warningBufferTrailerMagic(114), warningBufferTrailerBuffer(115), warningBufferTrailerLength(116), warningBufferTrailerUserMagic(117), warningBufferWriteAfterFree(118), warningBufferNotInUse(119), warningBufferMemcpyMagic(120), warningBufferMemcpyMagicNext(121), warningBufferNoExtraDRAM(129), -- V2P75 only: no xtra DRAM detected, or memtest on xtra DRAM failed errprPPPAsuncBufferInUse(130), -- PPP errors warningIpcpIpLookup(131), -- PPP errors warningBadChunk(135), -- wandata (& wansess) errors warningUnexpectedIF(136), -- wandata (& wansess) errors warningNoTimers(140), -- timer errors warningLCDAllocFailure(145), -- getBuff failure in lcd warningLCDNonSense(146), -- From lcdlogin.c; which should not be in this state warningMemcpyTooLarge(150), -- memcpy was called with too large a length warningMemcpyNoMagic(151), -- memcpy was called with too large a length warningMemcpyWrongMagic(152), -- memcpy was called with too large a length warningMemcpyBadStart(153), -- memcpy was called with too large a length warningWANBufferLeak(154), -- wandrv errors warningTermSrvState(160), -- termsrv debugging warningTermSrvSemaphore(161), -- termsrv debugging warningTelnetFreeDrv(165), -- telnet debugging warningSTACTimeout(170), -- stacdrv/compress debugging warningSTACDataNotOwned(171), -- stacdrv/compress debugging warningExecFailure(175), -- misc debugging warningExecRestricted(176), -- misc debugging warningExecNoMailbox(177), -- misc debugging sendMsg called w/NULL mbox warningExecNoResources(178), -- misc debugging sendMsg called w/NULL mbox warningUnexpected(179), -- an unexpected error warningChannelMapStuck(180), -- t1 missing channel debugging warningChannelDisplayStuck(181), -- t1 missing channel debugging warningNewCallNoDiscRequest(182), -- t1 missing channel debugging warningNewCallNoDiscResp(183), -- t1 missing channel debugging warningDisconnectRequestDropped(184), -- t1 missing channel debugging warningSpyderBuffer(185), -- spyder debugging warningSpyderDesc(186), -- spyder debugging warningSpyderLoseChannel(187), -- spyder debugging warningHscxSlowRelay(188), -- HSCX post problem on the 6000 warningTcpSbcontTooBig(190), -- TCP Error conditions warningTcpSequenceGap(191), -- TCP Error conditions warningTcpTooMuchData(192), -- TCP Error conditions warningTcpTooMuchWrite(193), -- TCP Error conditions warningTcpBadOptions(194), -- TCP Error conditions warningLmodSlotDown(195), warningLmodDspDown(196), warningLmodDspmodemDown(197), warningTcpXmitLooping(198), warningOspfFatal(200), -- OSPF's error messages. warningOspfWarn(201), -- OSPF's error messages. warningTacacsplusBase(300), -- TACACS+ error messages. warningTacacsplusPointerInconsistency(301), -- TACACS+ error messages. warningTacacsplusIndexInconsistency(302), -- TACACS+ error messages. warningTacacsplusTcpInconsistency(303), -- TACACS+ error messages. warningTacacsplusTcpOutofrangesocket(304), -- TACACS+ error messages. warningTacacsplusSocketMismatch(305), -- TACACS+ error messages. warningTacacsplusUnexpectedAuthState(306), -- TACACS+ error messages. warningTacacsplusMax(309), -- TACACS+ error messages. warningCidrWrongTree(310), -- CIDR Routing table warning messages. warningCidrNoMem(311), -- CIDR Routing table warning messages. warningCidrBusy(312), -- CIDR Routing table warning messages. warningCidrNonempty(313), -- CIDR Routing table warning messages. warningCidrDupDelete(314), -- CIDR Routing table warning messages. warningSauthWrongInfo(320), -- Source Auth (source-based CIDR) warning messages. warningSauthBadAddr(321), -- Source Auth (source-based CIDR) warning messages. warningGdbProtectionFault(330), -- GDB Errors warningInFilterList(381), -- Misc Errors warningNoCountInFilterList(382), -- Misc Errors warningMismatchCountFilterList(383), -- Misc Errors warningBadPowerSupply(400), -- Power supply failure in MAX 6000 redundant units warningEthernetNoTxBuf(550), -- Warning ran out of ethernet TX bufs warningDspCrashMin(512), -- Errors accompanied by a crash code in the lower 0xFF. warningDspCrashMax(767), -- (512 + 255) warningDspWrongSlot(768), warningUnalignedAccess(800), -- This is a MIPS only error currently warningH323NoResources(801), -- H.323 warnings warningEthernetCuBusy(1001), -- i82596/i82507 ethernet warnings warningEthernetAckFailure(1002), -- i82596/i82507 ethernet warnings warningEthernetReset(1003), -- i82596/i82507 ethernet warnings warningEthernetCuActive(1005), -- i82596/i82507 ethernet warnings warningEthernetWaitScb(1006), -- i82596/i82507 ethernet warnings warningEthernetNoMACAddress(1007), -- ethernet MAC address warning warningBaeepromChange(2001), -- EEPROM driver warnings warningBaeepromImageMismatch(2002), -- EEPROM driver warnings warningFlashTypeBad(2010), -- Flash used for SecPROM is the wrong type warningMaxiopLoadFailure(2022), -- MAX IOP failed to load warningIpxsapFilterMagic(3001), -- IPX SAP filter warnings warningIpxsapFilterCountZero(3002), -- IPX SAP filter warnings warningIpxsapFilterCountMismatch(3003), -- IPX SAP filter warnings warningModemTxChannelStuck(4000), -- stuck csmx transmit modem queue problem warningModemTxChannelRecovered(4100), -- stuck csmx transmit modem queue problem notApplicable(9998), unknown(9999) } ACCESS read-only STATUS mandatory DESCRIPTION "The error code for the previous box restart. The error codes are identical to ones obtained via fatal-history from the debug monitor screen." ::= { systemStatusGroup 13 } sysConfigChange OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name and security index (if available) of the user who changed the configuration." ::= { systemStatusGroup 14 } sysConfigFlash OBJECT IDENTIFIER ::= { systemStatusGroup 15 } fatalLogTable OBJECT-TYPE SYNTAX SEQUENCE OF FatalLogTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of the most recent Fatal Log entries of the system as well as the included slot cards" ::= { systemStatusGroup 16 } -- Table Definations fatalLogTableEntry OBJECT-TYPE SYNTAX FatalLogTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Definition of the row entries in the Fatal Log Table" INDEX { fatalLogIndex } ::= { fatalLogTable 1 } FatalLogTableEntry ::= SEQUENCE { fatalLogIndex INTEGER, fatalLogSlotIndex INTEGER, fatalLogSoftwareVerion DisplayString, fatalLogUserprofile DisplayString, fatalLogLoadName DisplayString, fatalLogLocation DisplayString, fatalLogReason INTEGER, fatalLogAbsouluteTime INTEGER } fatalLogIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Dynamic index that reflects the index used in the Fatal LOG table, starting with the most oldest event." ::= { fatalLogTableEntry 1 } fatalLogSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index into the slotTable This has the same value as slotIndex, it is set to 0 for systems with one logical slot card." ::= { fatalLogTableEntry 2 } fatalLogSoftwareVerion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The version of the software running, when this entry was created by the system." ::= { fatalLogTableEntry 3 } fatalLogUserprofile OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The user responsible for reseting the card. This will be set to the empty string if unknown." ::= { fatalLogTableEntry 4 } fatalLogLoadName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name of the Load executing on the card, it gives a textual description of the software code that was running on the system when the entry was created." ::= { fatalLogTableEntry 5 } fatalLogLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The IP address from which a manual system reset was triggered." ::= { fatalLogTableEntry 6 } fatalLogReason OBJECT-TYPE SYNTAX INTEGER { fatalAssert(1), fatalPoolsNoBuffer(2), fatalProfileBad(3), fatalSwitchTypeBad(4), fatalLif(5), fatalLcdError(6), fatalIsacTimeout(7), fatalSCCSpuriousInterrupt(8), -- 8 is a.k.a. PROCESSOR EXCEPTION!! fatalExecInvalidSwitch(9), fatalExecNoMailDesc(10), fatalExecNoMailPoll(11), fatalExecNoTask(12), fatalExecNoTimer(13), fataExecNoTimerPool(14), fatalExecWaitInCtricalSection(15), fatalDspDead(16), fatalDspProtocolError(17), fatalDspInternalError(18), fatalDspLossOfSync(19), fatalDspUnUsed(20), fatalDDDDead(21), fatalDDDProtocolError(22), fatalX25Buffers(23), fatalX25Init(24), fatalX25Stack(25), fatalZeroMemoryAlloc(27), fatalNegativeMemoryAllocate(28), fatalTaskLoop(29), fatalMemcpyTooLarge(30), fatalMemcpyNoMagic(31), fatalMemcpyWrongMagic(32), fatalMemcoyBadStart(33), fatalIDECTimeout(34), fatalExecRestricted(35), fatalStackOverflow(36), fatalDRAMCard(37), fatalMbufPanic(38), fatalNoPriority2Task(39), fatalProtectionFault(40), fatalClipping(41), -- clipping (may indicate memory leak) fatalReadyHangFault(42), fatalExcessPostCompl(43), fatalWriteProtect(44), fatalPureVirtual(45), -- C++ pure virtual call attempted fatalATMSVC(46), fatalFRSVC(47), fatalLinkedListCorruption(55), fatalCardBounced(96), fatalCardDown(97), fatalPrimarySelected(98), fatalOperatorReset(99), fatalSystemUp(100), warningBufferInUse(101), warningBufferWrongPool(102), warningBufferWrongHeap(103), warningBufferNotMemAlloc(104), warningBufferBadMemAlloc(105), warningBufferBogusPool(106), warningBufferBogusHeap(107), warningBufferNegativeMemalloc(108), warningBufferZeroMemalloc(109), warningBufferBoundary(110), warningBufferTooBig(111), warningBufferNull(112), warningBufferSegmentCountZero(113), warningBufferTrailerMagic(114), warningBufferTrailerBuffer(115), warningBufferTrailerLength(116), warningBufferTrailerUserMagic(117), warningBufferWriteAfterFree(118), warningBufferNotInUse(119), warningBufferMemcpyMagic(120), warningBufferMemcpyMagicNext(121), warningBufferNoExtraDRAM(129), -- V2P75 only: no xtra DRAM detected, or memtest on xtra DRAM failed errprPPPAsuncBufferInUse(130), -- PPP errors warningIpcpIpLookup(131), -- PPP errors warningBadChunk(135), -- wandata (& wansess) errors warningUnexpectedIF(136), -- wandata (& wansess) errors warningNoTimers(140), -- timer errors warningLCDAllocFailure(145), -- getBuff failure in lcd warningLCDNonSense(146), -- From lcdlogin.c; which should not be in this state warningMemcpyTooLarge(150), -- memcpy was called with too large a length warningMemcpyNoMagic(151), -- memcpy was called with too large a length warningMemcpyWrongMagic(152), -- memcpy was called with too large a length warningMemcpyBadStart(153), -- memcpy was called with too large a length warningWANBufferLeak(154), -- wandrv errors warningTermSrvState(160), -- termsrv debugging warningTermSrvSemaphore(161), -- termsrv debugging warningTelnetFreeDrv(165), -- telnet debugging warningSTACTimeout(170), -- stacdrv/compress debugging warningSTACDataNotOwned(171), -- stacdrv/compress debugging warningExecFailure(175), -- misc debugging warningExecRestricted(176), -- misc debugging warningExecNoMailbox(177), -- misc debugging sendMsg called w/NULL mbox warningExecNoResources(178), -- misc debugging sendMsg called w/NULL mbox warningUnexpected(179), -- an unexpected error warningChannelMapStuck(180), -- t1 missing channel debugging warningChannelDisplayStuck(181), -- t1 missing channel debugging warningNewCallNoDiscRequest(182), -- t1 missing channel debugging warningNewCallNoDiscResp(183), -- t1 missing channel debugging warningDisconnectRequestDropped(184), -- t1 missing channel debugging warningSpyderBuffer(185), -- spyder debugging warningSpyderDesc(186), -- spyder debugging warningSpyderLoseChannel(187), -- spyder debugging warningHscxSlowRelay(188), -- HSCX post problem on the 6000 warningTcpSbcontTooBig(190), -- TCP Error conditions warningTcpSequenceGap(191), -- TCP Error conditions warningTcpTooMuchData(192), -- TCP Error conditions warningTcpTooMuchWrite(193), -- TCP Error conditions warningTcpBadOptions(194), -- TCP Error conditions warningLmodSlotDown(195), warningLmodDspDown(196), warningLmodDspmodemDown(197), warningTcpXmitLooping(198), warningOspfFatal(200), -- OSPF's error messages. warningOspfWarn(201), -- OSPF's error messages. warningTacacsplusBase(300), -- TACACS+ error messages. warningTacacsplusPointerInconsistency(301), -- TACACS+ error messages. warningTacacsplusIndexInconsistency(302), -- TACACS+ error messages. warningTacacsplusTcpInconsistency(303), -- TACACS+ error messages. warningTacacsplusTcpOutofrangesocket(304), -- TACACS+ error messages. warningTacacsplusSocketMismatch(305), -- TACACS+ error messages. warningTacacsplusUnexpectedAuthState(306), -- TACACS+ error messages. warningTacacsplusMax(309), -- TACACS+ error messages. warningCidrWrongTree(310), -- CIDR Routing table warning messages. warningCidrNoMem(311), -- CIDR Routing table warning messages. warningCidrBusy(312), -- CIDR Routing table warning messages. warningCidrNonempty(313), -- CIDR Routing table warning messages. warningCidrDupDelete(314), -- CIDR Routing table warning messages. warningSauthWrongInfo(320), -- Source Auth (source-based CIDR) warning messages. warningSauthBadAddr(321), -- Source Auth (source-based CIDR) warning messages. warningGdbProtectionFault(330), -- GDB Errors warningInFilterList(381), -- Misc Errors warningNoCountInFilterList(382), -- Misc Errors warningMismatchCountFilterList(383), -- Misc Errors warningBadPowerSupply(400), -- Power supply failure in MAX 6000 redundant units warningEthernetNoTxBuf(550), -- Warning ran out of ethernet TX bufs warningDspCrashMin(512), -- Errors accompanied by a crash code in the lower 0xFF. warningDspCrashMax(767), -- (512 + 255) warningDspWrongSlot(768), warningUnalignedAccess(800), -- This is a MIPS only error currently warningH323NoResources(801), -- H.323 warnings warningEthernetCuBusy(1001), -- i82596/i82507 ethernet warnings warningEthernetAckFailure(1002), -- i82596/i82507 ethernet warnings warningEthernetReset(1003), -- i82596/i82507 ethernet warnings warningEthernetCuActive(1005), -- i82596/i82507 ethernet warnings warningEthernetWaitScb(1006), -- i82596/i82507 ethernet warnings warningEthernetNoMACAddress(1007), -- ethernet MAC address warning warningBaeepromChange(2001), -- EEPROM driver warnings warningBaeepromImageMismatch(2002), -- EEPROM driver warnings warningFlashTypeBad(2010), -- Flash used for SecPROM is the wrong type warningMaxiopLoadFailure(2022), -- MAX IOP failed to load warningIpxsapFilterMagic(3001), -- IPX SAP filter warnings warningIpxsapFilterCountZero(3002), -- IPX SAP filter warnings warningIpxsapFilterCountMismatch(3003), -- IPX SAP filter warnings warningModemTxChannelStuck(4000), -- stuck csmx transmit modem queue problem warningModemTxChannelRecovered(4100), -- stuck csmx transmit modem queue problem notApplicable(9998), unknown(9999) } ACCESS read-only STATUS mandatory DESCRIPTION "The reason for reset as reported by the system. For a more detailed description consult the user manual." ::= { fatalLogTableEntry 7 } fatalLogAbsouluteTime OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) ACCESS read-only STATUS mandatory DESCRIPTION "The time at which the system was reset." ::= { fatalLogTableEntry 8 } sysConfigFlashCmd OBJECT-TYPE SYNTAX INTEGER { copyPCMCIAtoInternal( 1 ), -- copy image from PCMCIA copyInternalToPCMCIA( 2 ) -- copy image from internal } ACCESS read-write STATUS mandatory DESCRIPTION "This variable instructs the system to copy the stored code image from PCMCIA flash to internal flash or vice versa." ::= { sysConfigFlash 1 } sysConfigFlashCopyStatus OBJECT-TYPE SYNTAX INTEGER { ok( 1 ), -- flash copy succeeded inProgress( 2 ), -- flash copy in progress failed( 3 ) -- flash copy failed } ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the status of a flash image copy." ::= { sysConfigFlash 2 } sysConfigInternalFlashImageVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The code version stored on the internal flash." ::= { sysConfigFlash 3 } sysConfigPCMCIAFlashImageVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The code version stored on the PCMCIA flash." ::= { sysConfigFlash 4 } -- Ascend configuration group -- -- Each profile is assigned an object ID. These ids are -- the root of MIB subtrees containing profile specific information. -- These subtrees, when required, are described in separate files. mibinternetProfile OBJECT IDENTIFIER ::= { configuration 1 } mibframeRelayProfile OBJECT IDENTIFIER ::= { configuration 2 } mibanswerProfile OBJECT IDENTIFIER ::= { configuration 3 } mibdS3NetworkProfile OBJECT IDENTIFIER ::= { configuration 4 } mibuds3NetworkProfile OBJECT IDENTIFIER ::= { configuration 5 } mibcadslNetworkProfile OBJECT IDENTIFIER ::= { configuration 6 } mibdadslNetworkProfile OBJECT IDENTIFIER ::= { configuration 7 } mibsdslNetworkProfile OBJECT IDENTIFIER ::= { configuration 8 } mibvdslNetworkProfile OBJECT IDENTIFIER ::= { configuration 9 } mibdmtAlDslNetworkProfile OBJECT IDENTIFIER ::= { configuration 10 } miboc3AtmNetworkProfile OBJECT IDENTIFIER ::= { configuration 11 } END