-- Ascend miboc3AtmNetworkProfile MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 7.11-104.0 or newer. -- ASCEND-MIBOC3ATMNETWORKPROFILE-MIB DEFINITIONS ::= BEGIN IMPORTS miboc3AtmNetworkProfile FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- The miboc3AtmNetworkProfile table -- -- This table contains parameters for the miboc3AtmNetworkProfile profile -- miboc3AtmNetworkProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF Miboc3AtmNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of miboc3AtmNetworkProfile profile entries." ::= { miboc3AtmNetworkProfile 1 } miboc3AtmNetworkProfileEntry OBJECT-TYPE SYNTAX Miboc3AtmNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A miboc3AtmNetworkProfile entry containing objects that maps to the parameters of miboc3AtmNetworkProfile profile." INDEX { oc3AtmNetworkProfile__shelf__, oc3AtmNetworkProfile__slot__, oc3AtmNetworkProfile__item__ } ::= { miboc3AtmNetworkProfileTable 1 } Miboc3AtmNetworkProfileEntry ::= SEQUENCE { oc3AtmNetworkProfile__shelf__ INTEGER, oc3AtmNetworkProfile__slot__ INTEGER, oc3AtmNetworkProfile__item__ INTEGER, oc3AtmNetworkProfile__name DisplayString, oc3AtmNetworkProfile__physical_address__shelf INTEGER, oc3AtmNetworkProfile__physical_address__slot INTEGER, oc3AtmNetworkProfile__physical_address__item_number INTEGER, oc3AtmNetworkProfile__enabled INTEGER, oc3AtmNetworkProfile__spare_physical_address__shelf INTEGER, oc3AtmNetworkProfile__spare_physical_address__slot INTEGER, oc3AtmNetworkProfile__spare_physical_address__item_number INTEGER, oc3AtmNetworkProfile__sparing_mode INTEGER, oc3AtmNetworkProfile__profile_number INTEGER, oc3AtmNetworkProfile__line_config__trunk_group INTEGER, oc3AtmNetworkProfile__line_config__nailed_group INTEGER, oc3AtmNetworkProfile__line_config__call_route_info__shelf INTEGER, oc3AtmNetworkProfile__line_config__call_route_info__slot INTEGER, oc3AtmNetworkProfile__line_config__call_route_info__item_number INTEGER, oc3AtmNetworkProfile__line_config__loopback INTEGER, oc3AtmNetworkProfile__line_config__framer_mode INTEGER, oc3AtmNetworkProfile__line_config__framer_rate INTEGER, oc3AtmNetworkProfile__line_config__rx_descramble_disabled INTEGER, oc3AtmNetworkProfile__line_config__tx_scramble_disabled INTEGER, oc3AtmNetworkProfile__line_config__rx_cell_payload_descramble_disabled INTEGER, oc3AtmNetworkProfile__line_config__tx_cell_payload_scramble_disabled INTEGER, oc3AtmNetworkProfile__line_config__loop_timing INTEGER, oc3AtmNetworkProfile__line_config__vpi_vci_range INTEGER, oc3AtmNetworkProfile__line_config__clock_source INTEGER, oc3AtmNetworkProfile__line_config__clock_priority INTEGER, oc3AtmNetworkProfile__action__ INTEGER } oc3AtmNetworkProfile__shelf__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfileEntry 1 } oc3AtmNetworkProfile__slot__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfileEntry 2 } oc3AtmNetworkProfile__item__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfileEntry 3 } oc3AtmNetworkProfile__name OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "For future use. The current design does not use the name field but instead references Oc3Atm lines by the physical address; we may in the future support referencing Oc3Atm lines by name as well as by address. The name consists of a null terminated ascii string supplied by the user; it defaults to the ascii form of the Oc3Atm line physical address." ::= { miboc3AtmNetworkProfileEntry 4 } oc3AtmNetworkProfile__physical_address__shelf OBJECT-TYPE SYNTAX INTEGER { any_shelf (1), shelf_1 (2), shelf_2 (3), shelf_3 (4), shelf_4 (5), shelf_5 (6), shelf_6 (7), shelf_7 (8), shelf_8 (9), shelf_9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { miboc3AtmNetworkProfileEntry 5 } oc3AtmNetworkProfile__physical_address__slot OBJECT-TYPE SYNTAX INTEGER { any_slot (1), slot_1 (2), slot_2 (3), slot_3 (4), slot_4 (5), slot_5 (6), slot_6 (7), slot_7 (8), slot_8 (9), slot_9 (10), slot_10 (11), slot_11 (12), slot_12 (13), slot_13 (14), slot_14 (15), slot_15 (16), slot_16 (17), slot_17 (18), slot_18 (19), slot_19 (20), slot_20 (21), slot_21 (22), slot_22 (23), slot_23 (24), slot_24 (25), slot_25 (26), slot_26 (27), slot_27 (28), slot_28 (29), slot_29 (30), slot_30 (31), slot_31 (32), slot_32 (33), slot_33 (34), slot_34 (35), slot_35 (36), slot_36 (37), slot_37 (38), slot_38 (39), slot_39 (40), slot_40 (41), controller (42), controller2 (43), trunk_module_1 (45), trunk_module_2 (46), slot_forward (44) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { miboc3AtmNetworkProfileEntry 6 } oc3AtmNetworkProfile__physical_address__item_number OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { miboc3AtmNetworkProfileEntry 7 } oc3AtmNetworkProfile__enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the line is enabled, otherwise FALSE." ::= { miboc3AtmNetworkProfileEntry 8 } oc3AtmNetworkProfile__spare_physical_address__shelf OBJECT-TYPE SYNTAX INTEGER { any_shelf (1), shelf_1 (2), shelf_2 (3), shelf_3 (4), shelf_4 (5), shelf_5 (6), shelf_6 (7), shelf_7 (8), shelf_8 (9), shelf_9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { miboc3AtmNetworkProfileEntry 9 } oc3AtmNetworkProfile__spare_physical_address__slot OBJECT-TYPE SYNTAX INTEGER { any_slot (1), slot_1 (2), slot_2 (3), slot_3 (4), slot_4 (5), slot_5 (6), slot_6 (7), slot_7 (8), slot_8 (9), slot_9 (10), slot_10 (11), slot_11 (12), slot_12 (13), slot_13 (14), slot_14 (15), slot_15 (16), slot_16 (17), slot_17 (18), slot_18 (19), slot_19 (20), slot_20 (21), slot_21 (22), slot_22 (23), slot_23 (24), slot_24 (25), slot_25 (26), slot_26 (27), slot_27 (28), slot_28 (29), slot_29 (30), slot_30 (31), slot_31 (32), slot_32 (33), slot_33 (34), slot_34 (35), slot_35 (36), slot_36 (37), slot_37 (38), slot_38 (39), slot_39 (40), slot_40 (41), controller (42), controller2 (43), trunk_module_1 (45), trunk_module_2 (46), slot_forward (44) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { miboc3AtmNetworkProfileEntry 10 } oc3AtmNetworkProfile__spare_physical_address__item_number OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { miboc3AtmNetworkProfileEntry 11 } oc3AtmNetworkProfile__sparing_mode OBJECT-TYPE SYNTAX INTEGER { inactive (1), manual (2), automatic (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Trunk port sparing operational mode for this port." ::= { miboc3AtmNetworkProfileEntry 12 } oc3AtmNetworkProfile__profile_number OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "For potential backwards compatibility. The current design consists of one line profile numbered 0." ::= { miboc3AtmNetworkProfileEntry 13 } oc3AtmNetworkProfile__line_config__trunk_group OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The trunk group to which this line is assigned. 0 means this line is not part of a trunk group." ::= { miboc3AtmNetworkProfileEntry 14 } oc3AtmNetworkProfile__line_config__nailed_group OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that identifies the set of lines that makes up a nailed group. 0 means this line is not part of a nailed group." ::= { miboc3AtmNetworkProfileEntry 15 } oc3AtmNetworkProfile__line_config__call_route_info__shelf OBJECT-TYPE SYNTAX INTEGER { any_shelf (1), shelf_1 (2), shelf_2 (3), shelf_3 (4), shelf_4 (5), shelf_5 (6), shelf_6 (7), shelf_7 (8), shelf_8 (9), shelf_9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { miboc3AtmNetworkProfileEntry 16 } oc3AtmNetworkProfile__line_config__call_route_info__slot OBJECT-TYPE SYNTAX INTEGER { any_slot (1), slot_1 (2), slot_2 (3), slot_3 (4), slot_4 (5), slot_5 (6), slot_6 (7), slot_7 (8), slot_8 (9), slot_9 (10), slot_10 (11), slot_11 (12), slot_12 (13), slot_13 (14), slot_14 (15), slot_15 (16), slot_16 (17), slot_17 (18), slot_18 (19), slot_19 (20), slot_20 (21), slot_21 (22), slot_22 (23), slot_23 (24), slot_24 (25), slot_25 (26), slot_26 (27), slot_27 (28), slot_28 (29), slot_29 (30), slot_30 (31), slot_31 (32), slot_32 (33), slot_33 (34), slot_34 (35), slot_35 (36), slot_36 (37), slot_37 (38), slot_38 (39), slot_39 (40), slot_40 (41), controller (42), controller2 (43), trunk_module_1 (45), trunk_module_2 (46), slot_forward (44) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { miboc3AtmNetworkProfileEntry 17 } oc3AtmNetworkProfile__line_config__call_route_info__item_number OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { miboc3AtmNetworkProfileEntry 18 } oc3AtmNetworkProfile__line_config__loopback OBJECT-TYPE SYNTAX INTEGER { no_loopback (1), facility_loopback (2), local_loopback (3), atm_layer_loopback (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Loopback mode." ::= { miboc3AtmNetworkProfileEntry 19 } oc3AtmNetworkProfile__line_config__framer_mode OBJECT-TYPE SYNTAX INTEGER { sonet (1), sdh (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The Sonet Framer mode." ::= { miboc3AtmNetworkProfileEntry 30 } oc3AtmNetworkProfile__line_config__framer_rate OBJECT-TYPE SYNTAX INTEGER { sTS_3c (1), sTS_1 (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The OC3 ATM framer rate." ::= { miboc3AtmNetworkProfileEntry 20 } oc3AtmNetworkProfile__line_config__rx_descramble_disabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the RX side descrambling is disabled, otherwise FALSE." ::= { miboc3AtmNetworkProfileEntry 21 } oc3AtmNetworkProfile__line_config__tx_scramble_disabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the TX side scrambling is disabled, otherwise FALSE." ::= { miboc3AtmNetworkProfileEntry 22 } oc3AtmNetworkProfile__line_config__rx_cell_payload_descramble_disabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the RX side cell payload descrambling is disabled, otherwise FALSE." ::= { miboc3AtmNetworkProfileEntry 23 } oc3AtmNetworkProfile__line_config__tx_cell_payload_scramble_disabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the TX side cell payload scrambling is disabled, otherwise FALSE." ::= { miboc3AtmNetworkProfileEntry 24 } oc3AtmNetworkProfile__line_config__loop_timing OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the TX timing is derived from the receiver inputs. FALSE if the TX timing is derived from reference clock." ::= { miboc3AtmNetworkProfileEntry 25 } oc3AtmNetworkProfile__line_config__vpi_vci_range OBJECT-TYPE SYNTAX INTEGER { n-0_1-32_32767 (1), n-0_3-32_16383 (2), n-0_7-32_8191 (3), n-0_15-32_4095 (4), n-0_31-32_2047 (5), n-0_63-32_1023 (6), n-0_127-32_511 (7), n-0_255-32_255 (8), vpi_0_255_vci_32_255 (9), vpi_0_255_vci_32_511 (10), vpi_0_255_vci_32_1023 (11), vpi_0_255_vci_32_2047 (12), vpi_0_255_vci_32_4095 (13), vpi_0_255_vci_32_8191 (14), vpi_0_255_vci_32_16383 (15) } ACCESS read-write STATUS mandatory DESCRIPTION "The OC3 ATM valid VPI/VCI value range." ::= { miboc3AtmNetworkProfileEntry 26 } oc3AtmNetworkProfile__line_config__clock_source OBJECT-TYPE SYNTAX INTEGER { eligible (1), not_eligible (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determine whether the 8KHz clock from the OC3-ATM board is eligible to be used as the system-wide TDM clock source." ::= { miboc3AtmNetworkProfileEntry 27 } oc3AtmNetworkProfile__line_config__clock_priority OBJECT-TYPE SYNTAX INTEGER { high_priority (2), middle_priority (3), low_priority (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Clock priority assigned to the OC3-ATM line. Used to select a particular OC3 line as clock source." ::= { miboc3AtmNetworkProfileEntry 28 } oc3AtmNetworkProfile__action__ OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfileEntry 29 } miboc3AtmNetworkProfile__line_config__incomingVCCsTable OBJECT-TYPE SYNTAX SEQUENCE OF Miboc3AtmNetworkProfile__line_config__incomingVCCsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of miboc3AtmNetworkProfile__line_config__incomingVCCs profile entries." ::= { miboc3AtmNetworkProfile 2 } miboc3AtmNetworkProfile__line_config__incomingVCCsEntry OBJECT-TYPE SYNTAX Miboc3AtmNetworkProfile__line_config__incomingVCCsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A miboc3AtmNetworkProfile__line_config__incomingVCCs entry containing objects that maps to the parameters of miboc3AtmNetworkProfile__line_config__incomingVCCs profile." INDEX { oc3AtmNetworkProfile__line_config__incomingVCCs__shelf__, oc3AtmNetworkProfile__line_config__incomingVCCs__slot__, oc3AtmNetworkProfile__line_config__incomingVCCs__item__, oc3AtmNetworkProfile__line_config__incomingVCCs__index__ } ::= { miboc3AtmNetworkProfile__line_config__incomingVCCsTable 1 } Miboc3AtmNetworkProfile__line_config__incomingVCCsEntry ::= SEQUENCE { oc3AtmNetworkProfile__line_config__incomingVCCs__shelf__ INTEGER, oc3AtmNetworkProfile__line_config__incomingVCCs__slot__ INTEGER, oc3AtmNetworkProfile__line_config__incomingVCCs__item__ INTEGER, oc3AtmNetworkProfile__line_config__incomingVCCs__index__ INTEGER, oc3AtmNetworkProfile__line_config__incomingVCCs__enabled INTEGER, oc3AtmNetworkProfile__line_config__incomingVCCs__vpi INTEGER, oc3AtmNetworkProfile__line_config__incomingVCCs__start_vci INTEGER, oc3AtmNetworkProfile__line_config__incomingVCCs__end_vci INTEGER } oc3AtmNetworkProfile__line_config__incomingVCCs__shelf__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__incomingVCCsEntry 1 } oc3AtmNetworkProfile__line_config__incomingVCCs__slot__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__incomingVCCsEntry 2 } oc3AtmNetworkProfile__line_config__incomingVCCs__item__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__incomingVCCsEntry 3 } oc3AtmNetworkProfile__line_config__incomingVCCs__index__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__incomingVCCsEntry 4 } oc3AtmNetworkProfile__line_config__incomingVCCs__enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the item is enabled, otherwise FALSE." ::= { miboc3AtmNetworkProfile__line_config__incomingVCCsEntry 5 } oc3AtmNetworkProfile__line_config__incomingVCCs__vpi OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that identifies the Virtual Path Identifier of this item." ::= { miboc3AtmNetworkProfile__line_config__incomingVCCsEntry 6 } oc3AtmNetworkProfile__line_config__incomingVCCs__start_vci OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that identifies the starting Virtual Channel Identifier of this item." ::= { miboc3AtmNetworkProfile__line_config__incomingVCCsEntry 7 } oc3AtmNetworkProfile__line_config__incomingVCCs__end_vci OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that identifies the ending Virtual Channel Identifier of this item." ::= { miboc3AtmNetworkProfile__line_config__incomingVCCsEntry 8 } miboc3AtmNetworkProfile__line_config__traffic_shapersTable OBJECT-TYPE SYNTAX SEQUENCE OF Miboc3AtmNetworkProfile__line_config__traffic_shapersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of miboc3AtmNetworkProfile__line_config__traffic_shapers profile entries." ::= { miboc3AtmNetworkProfile 3 } miboc3AtmNetworkProfile__line_config__traffic_shapersEntry OBJECT-TYPE SYNTAX Miboc3AtmNetworkProfile__line_config__traffic_shapersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A miboc3AtmNetworkProfile__line_config__traffic_shapers entry containing objects that maps to the parameters of miboc3AtmNetworkProfile__line_config__traffic_shapers profile." INDEX { oc3AtmNetworkProfile__line_config__traffic_shapers__shelf__, oc3AtmNetworkProfile__line_config__traffic_shapers__slot__, oc3AtmNetworkProfile__line_config__traffic_shapers__item__, oc3AtmNetworkProfile__line_config__traffic_shapers__index__ } ::= { miboc3AtmNetworkProfile__line_config__traffic_shapersTable 1 } Miboc3AtmNetworkProfile__line_config__traffic_shapersEntry ::= SEQUENCE { oc3AtmNetworkProfile__line_config__traffic_shapers__shelf__ INTEGER, oc3AtmNetworkProfile__line_config__traffic_shapers__slot__ INTEGER, oc3AtmNetworkProfile__line_config__traffic_shapers__item__ INTEGER, oc3AtmNetworkProfile__line_config__traffic_shapers__index__ INTEGER, oc3AtmNetworkProfile__line_config__traffic_shapers__enabled INTEGER, oc3AtmNetworkProfile__line_config__traffic_shapers__bit_rate INTEGER, oc3AtmNetworkProfile__line_config__traffic_shapers__peak_rate INTEGER, oc3AtmNetworkProfile__line_config__traffic_shapers__max_burst_size INTEGER, oc3AtmNetworkProfile__line_config__traffic_shapers__aggregate INTEGER, oc3AtmNetworkProfile__line_config__traffic_shapers__priority INTEGER } oc3AtmNetworkProfile__line_config__traffic_shapers__shelf__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__traffic_shapersEntry 1 } oc3AtmNetworkProfile__line_config__traffic_shapers__slot__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__traffic_shapersEntry 2 } oc3AtmNetworkProfile__line_config__traffic_shapers__item__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__traffic_shapersEntry 3 } oc3AtmNetworkProfile__line_config__traffic_shapers__index__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__traffic_shapersEntry 4 } oc3AtmNetworkProfile__line_config__traffic_shapers__enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the shaper is enabled, otherwise FALSE." ::= { miboc3AtmNetworkProfile__line_config__traffic_shapersEntry 5 } oc3AtmNetworkProfile__line_config__traffic_shapers__bit_rate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "What is the sustained rate in Kilobits per second that can be transmitted by the VC(s) when using this shaper. Limited by the framer mode and the interface type." ::= { miboc3AtmNetworkProfile__line_config__traffic_shapersEntry 6 } oc3AtmNetworkProfile__line_config__traffic_shapers__peak_rate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "What is the peak rate in Kilobits per second that can be transmitted by the VC(s) when using this shaper. Limited by the framer mode and the interface type." ::= { miboc3AtmNetworkProfile__line_config__traffic_shapersEntry 7 } oc3AtmNetworkProfile__line_config__traffic_shapers__max_burst_size OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "What is the maximum burst size in cell that can be transmitted during the peak rate by the VC(s) when using this shaper." ::= { miboc3AtmNetworkProfile__line_config__traffic_shapersEntry 8 } oc3AtmNetworkProfile__line_config__traffic_shapers__aggregate OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "If FALSE the bit rate that this shaper occupies depends on the number of VCs that are attached to it. If TRUE the VCs share the bit rate that is assigned to this shaper equally." ::= { miboc3AtmNetworkProfile__line_config__traffic_shapersEntry 9 } oc3AtmNetworkProfile__line_config__traffic_shapers__priority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that represent the prioriy of the shaper in respect to other shapers. 0 is the highest priority and 15 is the lowest." ::= { miboc3AtmNetworkProfile__line_config__traffic_shapersEntry 10 } miboc3AtmNetworkProfile__line_config__vc_switching_vpiTable OBJECT-TYPE SYNTAX SEQUENCE OF Miboc3AtmNetworkProfile__line_config__vc_switching_vpiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of miboc3AtmNetworkProfile__line_config__vc_switching_vpi profile entries." ::= { miboc3AtmNetworkProfile 4 } miboc3AtmNetworkProfile__line_config__vc_switching_vpiEntry OBJECT-TYPE SYNTAX Miboc3AtmNetworkProfile__line_config__vc_switching_vpiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A miboc3AtmNetworkProfile__line_config__vc_switching_vpi entry containing objects that maps to the parameters of miboc3AtmNetworkProfile__line_config__vc_switching_vpi profile." INDEX { oc3AtmNetworkProfile__line_config__vc_switching_vpi__shelf__, oc3AtmNetworkProfile__line_config__vc_switching_vpi__slot__, oc3AtmNetworkProfile__line_config__vc_switching_vpi__item__, oc3AtmNetworkProfile__line_config__vc_switching_vpi__index__ } ::= { miboc3AtmNetworkProfile__line_config__vc_switching_vpiTable 1 } Miboc3AtmNetworkProfile__line_config__vc_switching_vpiEntry ::= SEQUENCE { oc3AtmNetworkProfile__line_config__vc_switching_vpi__shelf__ INTEGER, oc3AtmNetworkProfile__line_config__vc_switching_vpi__slot__ INTEGER, oc3AtmNetworkProfile__line_config__vc_switching_vpi__item__ INTEGER, oc3AtmNetworkProfile__line_config__vc_switching_vpi__index__ INTEGER, oc3AtmNetworkProfile__line_config__vc_switching_vpi INTEGER } oc3AtmNetworkProfile__line_config__vc_switching_vpi__shelf__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__vc_switching_vpiEntry 1 } oc3AtmNetworkProfile__line_config__vc_switching_vpi__slot__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__vc_switching_vpiEntry 2 } oc3AtmNetworkProfile__line_config__vc_switching_vpi__item__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__vc_switching_vpiEntry 3 } oc3AtmNetworkProfile__line_config__vc_switching_vpi__index__ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { miboc3AtmNetworkProfile__line_config__vc_switching_vpiEntry 4 } oc3AtmNetworkProfile__line_config__vc_switching_vpi OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "VPI(s) to be used for the VC switching (VCC) on top of VPI 0 which is always used for VC switching. All VC switching VPI have similar valid VCI range which is determined by 'vpi-vci-range' attribute. Rest of the VPIs will be used for the VP switching. The user needs to understand that adding a VPI in a list of VC switching VPI will allocate more VCCs for this port. The user needs to make sure that VCCs for the other ports have been reduced to accomodate increase in VCC for this port because system can support only 32k VCCs on all trunk ports combined. If vci-range is 4k and VPI 0 is the only VPI doing VC switching for this port than this port occupies 4k VCCs. If user adds VPI 1 to the list of VPIs to do VCC then total 8k VCCs are occupied for this port. System will reject the confiugration if user tries to use more than 32k VCCs for all trunk ports combined. ANY CHANGES IN A LIST OF VPIs WILL BE EFFECTIVE IMMEDIATLY. IN ORDER TO DO THAT ALL CONNECTIONS WITHIN THIS SYSTEM WILL BE DROPPED AND REESTABLISHED." ::= { miboc3AtmNetworkProfile__line_config__vc_switching_vpiEntry 5 } END