-- ***************************************************************** -- MY-PING-MIB.mib: My Ping MIB file -- -- $Copyright$ -- -- ***************************************************************** -- MY-PING-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Counter32 FROM SNMPv2-SMI TruthValue, DisplayString, RowStatus FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF IfIndex FROM MY-TC myMgmt FROM MY-SMI; myPingMIB MODULE-IDENTITY LAST-UPDATED "200203200000Z" ORGANIZATION "$Company$" CONTACT-INFO " Tel: $Telephone$ E-mail: $E-mail$" DESCRIPTION "This module defines my ping mibs." REVISION "200203200000Z" DESCRIPTION "Initial version of this MIB module." ::= { myMgmt 3} myPingMIBObjects OBJECT IDENTIFIER ::= { myPingMIB 1 } myPingTable OBJECT-TYPE SYNTAX SEQUENCE OF MyPingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of ping request entries." ::= { myPingMIBObjects 1 } myPingEntry OBJECT-TYPE SYNTAX MyPingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains ping parameters and results. A management station wishing to create an entry should first generate a pseudo-random serial number to be used as the index to a ping entry. The station should then create the associated entry. We must set all specifies valid values for the non-defaulted configuration objects, certainly, it should also modify the default values for the other configuration objects if the defaults are not appropriate. Once the appropriate instance of all the configuration objects have been created or set,the row status should be set to active to initiate the request. Once the ping sequence has been activated, it cannot be stopped -- it will run until the configured number of packets have been sent. Once the sequence completes, the management station should retrieve the values of the status objects of interest, and should then delete the entry. In order to prevent old entries from clogging the table, entries will be aged out, but an entry will never be deleted within 5 minutes of completing." INDEX { myPingIndex } ::= { myPingTable 1 } MyPingEntry ::= SEQUENCE { myPingIndex Integer32, myPingAddress IpAddress, myPingDataLength Unsigned32, myPingTimes Unsigned32, myPingTimeOuts Unsigned32, myPingReturns Unsigned32, myPingMaxTime Unsigned32, myPingAvTime Unsigned32, myPingMinTime Integer32, myPingCompleted TruthValue, myPingEntryStauts RowStatus, myPingSourceIp IpAddress, myPingSourceInterfaceIndex IfIndex, myPingTypeOfService Unsigned32 } myPingIndex OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Object which specifies a unique entry in the myPingTable. A management station wishing to initiate a ping operation should use a pseudo-random value for this object when creating or modifying an instance of a myPingEntry. The RowStatus semantics of the myPingEntryStatus object will prevent access conflicts." ::= { myPingEntry 1 } myPingAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Pinged host ip address." ::= { myPingEntry 2 } myPingDataLength OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Pinged ICMP echo datagram's data length." DEFVAL { 100 } ::= { myPingEntry 3 } myPingTimes OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Pimes the ICMP echo datagrams will be sent." DEFVAL { 5 } ::= { myPingEntry 4 } myPingTimeOuts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Ping but no echo from required address, the time last for time out, in milliseconds." DEFVAL { 2000 } ::= { myPingEntry 5 } myPingReturns OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "How many echo request has been return by a echo reply." ::= { myPingEntry 6 } myPingMaxTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max return time of the echo reply." ::= { myPingEntry 7 } myPingAvTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average returned time of the echo reply of that reply but not time out." ::= { myPingEntry 8 } myPingMinTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min returned time of the echo reply." ::= { myPingEntry 9 } myPingCompleted OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "While the ping process has completed the value of this field will be true(1), else false(2)." ::= { myPingEntry 10 } myPingEntryStauts OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "entry status for this list." ::= { myPingEntry 11 } myPingSourceIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "the address of source interface." ::= { myPingEntry 12 } myPingSourceInterfaceIndex OBJECT-TYPE SYNTAX IfIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex value of this source interface." ::= { myPingEntry 13 } myPingTypeOfService OBJECT-TYPE SYNTAX Unsigned32(0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "the value of type of service." ::= { myPingEntry 14 } -- conformance information myPingMIBConformance OBJECT IDENTIFIER ::= { myPingMIB 2 } myPingMIBCompliances OBJECT IDENTIFIER ::= { myPingMIBConformance 1 } myPingMIBGroups OBJECT IDENTIFIER ::= { myPingMIBConformance 2 } -- compliance statements myPingMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the My Ping MIB" MODULE -- this module MANDATORY-GROUPS { myPingMIBGroup } ::= { myPingMIBCompliances 1 } -- units of conformance myPingMIBGroup OBJECT-GROUP OBJECTS { myPingIndex , myPingAddress , myPingDataLength , myPingTimes , myPingTimeOuts , myPingReturns , myPingMaxTime , myPingAvTime , myPingMinTime , myPingCompleted , myPingEntryStauts, myPingSourceIp , myPingSourceInterfaceIndex , myPingTypeOfService } STATUS current DESCRIPTION "A collection of objects providing ping (echo) ability to a My agent." ::= { myPingMIBGroups 1 } -- hcb add traceRouteMIBObjects OBJECT IDENTIFIER ::= { myPingMIB 3 } -- traceRouteTable traceRouteTable OBJECT-TYPE SYNTAX SEQUENCE OF TraceRouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of trace route request entries. The traceRouteTable will contain a set of trace route requests that need to be executed at the agent." ::= { traceRouteMIBObjects 1 } -- traceRouteEntry traceRouteEntry OBJECT-TYPE SYNTAX TraceRouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A trace route request entry." INDEX { traceRouteIndex } ::= { traceRouteTable 1 } TraceRouteEntry ::= SEQUENCE { traceRouteIndex Unsigned32, traceRouteTargetAddr IpAddress, traceRouteHopCount Unsigned32, traceRoutePingCount Unsigned32, traceRoutePingTimeout Unsigned32, traceRouteRowStatus RowStatus } traceRouteIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of a trace route entry. " ::= { traceRouteEntry 1 } traceRouteTargetAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The address of the device to which the route is to be traced." ::= { traceRouteEntry 2 } traceRouteHopCount OBJECT-TYPE SYNTAX Unsigned32(1..100) MAX-ACCESS read-create STATUS current DESCRIPTION "Wait timeout milliseconds for each reply." DEFVAL { 30 } ::= { traceRouteEntry 3 } traceRoutePingCount OBJECT-TYPE SYNTAX Unsigned32(1..6) MAX-ACCESS read-create STATUS current DESCRIPTION "Repeat count for each echo." DEFVAL { 3 } ::= { traceRouteEntry 4 } traceRoutePingTimeout OBJECT-TYPE SYNTAX Unsigned32(1..60000) MAX-ACCESS read-create STATUS current DESCRIPTION "Wait timeout milliseconds for each reply." DEFVAL { 2000 } ::= { traceRouteEntry 5 } traceRouteRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "entry status for this list." ::= { traceRouteEntry 6 } -- traceRouteHopsTable traceRouteHopsTable OBJECT-TYPE SYNTAX SEQUENCE OF TraceRouteHopsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of trace route hop results. This table contains the hop-by-hop result of a trace route test performed for an entry in the traceRouteTable." ::= { traceRouteMIBObjects 2 } traceRouteHopsEntry OBJECT-TYPE SYNTAX TraceRouteHopsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A trace route hop entry." INDEX { traceRouteIndex, traceRouteHopIndex } ::= { traceRouteHopsTable 1 } TraceRouteHopsEntry ::= SEQUENCE { traceRouteHopIndex Unsigned32, traceRouteHopPingIndex Unsigned32, traceRouteHopPingCompleted TruthValue, traceRouteHopPingResult TruthValue, traceRouteHopPingReturnTime Unsigned32, traceRouteHopAddr IpAddress } traceRouteHopIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the hop index for a traceroute hop. Values for this object with respect to the same traceRouteIndex MUST start at 1 and increase monotonically. All hops (traceRouteHopsTable entries) in a trace route path MUST be updated at the same time when a trace route test completes." ::= { traceRouteHopsEntry 1 } traceRouteHopPingIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the hop index for a Icmp echo. Values for this object with respect to the same traceRouteIndex and the same traceRouteHopIndex MUST start at 1 and increase monotonically. " ::= { traceRouteHopsEntry 2 } traceRouteHopPingCompleted OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "While the ping process has completed the value of this field will be true(1), else false(2)." ::= { traceRouteHopsEntry 3 } traceRouteHopPingResult OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "While the ping process has completed and the Icmp echo reply or Icmp ttl expiration has received, the value of this field will be true(1), else false(2)." ::= { traceRouteHopsEntry 4 } traceRouteHopPingReturnTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returned time of the echo reply of that reply but not time out." ::= { traceRouteHopsEntry 5 } traceRouteHopAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the WWN of the device associated with this hop." ::= { traceRouteHopsEntry 6 } END