Description 1
This measurement provides the number of unsuccessful intra CELL Handovers, i.e. an attempt was made to move a call from the occupied channel of the CELL to another free channel of the same CELL, on a per BSC basis. Collection method: CC. Counting trigger or measurement procedure: Receipt of "ASSIGNMENT FAILURE" Message for the attempted handover (GSM 04.08 [2]). Result: A single integer value. Measurement function: BSC Measurement Function. Applicability: Valid for circuit switching.