OID reference

ieee8021MstpCistPortAutoEdgePort

2.49.0.2.111.2.802.1.1.6.1.8.1.1

Description

The administrative value of the Auto Edge Port parameter. A value of true(1) indicates if the Bridge detection state machine (BDM, 13.31) is to detect other Bridges attached to the LAN, and set ieee8021SpanningTreeRstpPortOperEdgePort automatically. The default value is true(1) This is optional and provided only by im…

Full description and source information

Identification

Identifier and names

Parent
2.49.0.2.111.2.802.1.1.6.1.8.1 (ieee8021MstpCistPortExtensionEntry)
Node code
1
Node name
ieee8021MstpCistPortAutoEdgePort
Numeric OID
2.49.0.2.111.2.802.1.1.6.1.8.1.1
URN notation
urn:oid:2.49.0.2.111.2.802.1.1.6.1.8.1.1
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{2 49 0 2 111 2 802 1 1 6 1 8 1 1}

  • {joint-iso-itu-t(2) alerting(49) wmo(0) org(2) 111 2 802 1 ieee802dot1mibs(1) ieee8021MstpMib(6) ieee8021MstpObjects(1) ieee8021MstpCistPortExtensionTable(8) ieee8021MstpCistPortExtensionEntry(1) ieee8021MstpCistPortAutoEdgePort(1)}
  • {joint-iso-ccitt(2) alerting(49) wmo(0) org(2) 111 2 802 1 ieee802dot1mibs(1) ieee8021MstpMib(6) ieee8021MstpObjects(1) ieee8021MstpCistPortExtensionTable(8) ieee8021MstpCistPortExtensionEntry(1) ieee8021MstpCistPortAutoEdgePort(1)}
OID-IRI notation
  • /2/49/0/2/111/2/802/1/1/6/1/8/1/1
  • /Alerting/WMO/2/111/2/802/1/1/6/1/8/1/1
  • /Alerting/0/2/111/2/802/1/1/6/1/8/1/1
  • /Joint-ISO-ITU-T/49/0/2/111/2/802/1/1/6/1/8/1/1
Named path variants
  • /joint-iso-itu-t/alerting/wmo/org/111/2/802/1/ieee802dot1mibs/ieee8021MstpMib/ieee8021MstpObjects/ieee8021MstpCistPortExtensionTable/ieee8021MstpCistPortExtensionEntry/ieee8021MstpCistPortAutoEdgePort
  • /joint-iso-ccitt/alerting/wmo/org/111/2/802/1/ieee802dot1mibs/ieee8021MstpMib/ieee8021MstpObjects/ieee8021MstpCistPortExtensionTable/ieee8021MstpCistPortExtensionEntry/ieee8021MstpCistPortAutoEdgePort

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The administrative value of the Auto Edge Port parameter.
A value of true(1) indicates if the Bridge detection state
machine (BDM, 13.31) is to detect other Bridges
attached to the LAN, and set
ieee8021SpanningTreeRstpPortOperEdgePort automatically.
The default value is true(1)

This is optional and provided only by implementations
that support the automatic identification of edge ports.

The value of this object MUST be retained across
reinitializations of the management system.
Sources for this description

IEEE 802

Historical records

Additional source information

Information from IEEE 802
ieee8021MstpCistPortAutoEdgePort OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The administrative value of the Auto Edge Port parameter.
         A value of true(1) indicates if the Bridge detection state 
         machine (BDM, 13.31) is to detect other Bridges
         attached to the LAN, and set 
         ieee8021SpanningTreeRstpPortOperEdgePort automatically.
         The default value is true(1)

         This is optional and provided only by implementations 
         that support the automatic identification of edge ports.

         The value of this object MUST be retained across
         reinitializations of the management system."
    REFERENCE   "12.8.2.1.3 )"
    ::= { ieee8021MstpCistPortExtensionEntry 1 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 2.49.0.2)

Ms. Haleh Kootval

Current Registration Authority (inferred from ancestor 2.49.0)

Ms. Haleh Kootval

Siblings (1)

OIDNameDirect childrenDescendantsDescription
2.49.0.2.111.2.802.1.1.6.1.8.1.2 ieee8021MstpCistPortAutoIsolatePort00 The operational value of the Isolate Port parameter.

A value of true(1) indicates a Designated Port will
transition to discarding…