Objects in IDRAC-MIB

OID records

OIDNameDescription
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2controllerNameThe controller's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.3alertGroup
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.50controllerBGIRateThe background initialization (BGI) rate is the percentage of the
controller’s resources dedicated to performing the background
initialization of a redundant vir…
1.3.6.1.4.1.674.10892.5.4.200.10.1.24systemStateTemperatureStatusCombined0200.0010.0001.0024 This attribute defines the combined status of all
temperature probes of this system.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.19networkDevicePCIFunctionNumber1100.0090.0001.0019 This attribute defines the PCI function number of the
network device.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4physicalDiskTableA table of managed physical disks. The number of entries is
related to number of physical Disks discovered in the system.
The maximum number of entries is implem…
1.3.6.1.4.1.674.10892.5.3.1.4alertSystemServiceTagService tag of the system.
1.3.6.1.4.1.674.10892.5.4.700.12.1.13coolingDeviceLowerCriticalThreshold0700.0012.0001.0013 This attribute defines the lower critical threshold
of the cooling device. The value is an integer representing fan speed
in revolutions per…
1.3.6.1.4.1.674.10892.5.4.300.10.1.35chassiswatchDogControlExpiryTimeCapabilitiesUnique0300.0010.0001.0035 This attribute defines the capabilities of the
watchdog control expiry timer function.
1.3.6.1.4.1.674.10892.5.4.600.12.1.14powerSupplyRatedInputWattage0600.0012.0001.0014 This attribute defines the rated input wattage of the
power supply (in tenths of Watts).
1.3.6.1.4.1.674.10892.5.4.300.10.1.4chassisStatus0300.0010.0001.0004 This attribute defines the status of the system chassis.
1.3.6.1.4.1.674.10892.5.4.700.10coolingUnitTable0700.0010 This object defines the Cooling Unit Table.
1.3.6.1.4.1.674.10892.5.4.700.12coolingDeviceTable0700.0012 This object defines the Cooling Device Table.
1.3.6.1.4.1.674.10892.5.4.600.12.1.9powerSupplyInputVoltage, powerSupplyMaximumInputVoltage0600.0012.0001.0009 This attribute defines the input voltage to the power
supply (in Volts).
1.3.6.1.4.1.674.10892.5.4.700.12.1.12coolingDeviceLowerNonCriticalThreshold0700.0012.0001.0012 This attribute defines the lower noncritical threshold
of the cooling device. The value is an integer representing fan speed
in revolutions …
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.82controllerEnhancedAutoImportForeignConfigModeIndicates the status of enhanced auto-import of foreign configuration property of the controller. 1: Not one of the following. 2: Not Supported. 3: Disabled. 4…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79controllerDisplayNameThe controller's friendly FQDD as represented in Storage
Management.
1.3.6.1.4.1.674.10892.5.4.600.30.1.13amperageProbeLowerCriticalThreshold0600.0030.0001.0013 This attribute defines the lower critical threshold
of the amperage probe. The value is an integer representing the amperage
of the threshol…
1.3.6.1.4.1.674.10892.5.4.300.40.1.6eventLogFormat0300.0040.0001.0006 This attribute defines the format of the event log record.
1.3.6.1.4.1.674.10892.5.4.200.10.1.15systemStateAmperageStatusCombined0200.0010.0001.0015 This attribute defines the combined status of all
amperage probes of this system.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.84controllerBootModeIndicates the boot mode of the controller. Possible values: 1: Not applicable for this controller. 2: User mode: User interaction required for all boot message…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.8controllerFWVersionThe controller's current firmware version.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.53controllerPatrolReadStateThis property displays the current state of the patrol read process.
Possible values:
1: Not one of the following.
1: Patrol read is not running.
2: Patrol read is…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.60controllerSpinDownUnconfiguredDrivesIndicates whether un-configured drives would be put in power
save mode by the controller.
1.3.6.1.4.1.674.10892.5.4.200.10.1.18systemStateCoolingUnitStatusRedundancy0200.0010.0001.0018 This attribute defines the combined redundancy status
of all cooling units of this system.
1.3.6.1.4.1.674.10892.5.4.700.20.1.14temperatureProbeLowerNonRecoverableThreshold0700.0020.0001.0014 This attribute defines the lower nonrecoverable threshold
of the temperature probe. The value is an integer representing the temperature
of …
1.3.6.1.4.1.674.10892.5.5.1.20.130.1controllerTableA table of managed RAID controllers. The number of entries
is related to number of RAID controllers discovered in the
system. The maximum number of entries is im…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.1controllerNumberInstance number of this controller entry.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.41controllerDriverVersionCurrently installed driver version for this controller on the host.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.42controllerPCISlotThe PCI slot on the server where the controller is seated. This
data is not reported for embedded or integrated controllers,
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.48controllerReconstructRateThe reconstruct rate is the percentage of the controller’s resources
dedicated to reconstructing a disk group after adding a physical disk
or changing the RAID l…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.49controllerPatrolReadRateThe patrol read rate is the percentage of the controller’s
resources dedicated to perform a patrol read on disks participating
in a virtual disk or hot spares.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.52controllerPatrolReadModeIdentifies the patrol read mode setting for the controller.
Possible values:
1: Not one of the following.
2: Not Supported on this controller.
3: Disabled.
4: Autom…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.61controllerSpinDownHotSpareDrivesIndicates whether hot spare drives would be put in power
save mode by the controller.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.62controllerSpinDownTimeIntervalThe duration in minutes after which, the unconfigured or hot
spare drives will be spun down to power save mode.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.69controllerPreservedCacheIndicates whether preserved cache or pinned cache is
present on the controller.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.72controllerSecurityStatusThe controller's current security/encryption status..
Possible values:
1: The current status could not be determined.
2: Controller is not operating in an encrypt…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.74controllerEncryptionCapabilityThe type of encryption supported by the controller.
Possible values:
1: Not one of the following.
2: No encryption supported,
3: Local Key Management,
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.75controllerLoadBalanceSettingThe ability of the controller to automatically use both
controller ports (or connectors) connected to the same enclosure in
order to route I/O requests.
Possible …
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.76controllerMaxCapSpeedThe maximum speed of the controller.in
Gigbits per second (Gbps).
Possible values:
1: The speed could not be determined.
2. 1.5Gbs
3: 3.0Gbs
4: 6.0Gbs
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.78controllerFQDDThe controller's Fully Qualified Device Descriptor (FQDD) as
represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.80controllerT10PICapabilityIndicates whether the controller supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible value…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.81controllerRAID10UnevenSpansSupportedIndicates whether uneven spans for RAID 10 virtual disk is supported on the controller.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.9controllerCacheSizeInMBThe controller's current amount of cache memory in megabytes.
1.3.6.1.4.1.674.10892.5.4.1.3mIBMaintenanceVersionNumber0001.0003 This attribute defines the maintenance version number for
the version of this MIB supported by the iDRAC.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.26processorDeviceFQDD1100.0030.0001.0026 Fully qualified device descriptor (FQDD) of the
processor device.
1.3.6.1.4.1.674.10892.5.4.200.10.1.9systemStatePowerSupplyStatusCombined0200.0010.0001.0009 This attribute defines the combined status of all
power supplies of this system.
1.3.6.1.4.1.674.10892.5.4.1100.50memoryDeviceTable1100.0050 This object defines the Memory Device Table.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.1memoryDevicechassisIndex1100.0050.0001.0001 This attribute defines the index (one based) of the
associated system chassis.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.15memoryDeviceSpeed1100.0050.0001.0015 This attribute defines the speed in nanoseconds
of the memory device. Zero indicates an unknown speed.