Objects in IDRAC-MIB

OID records

OIDNameDescription
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.2enclosureFanNameThe fan's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.20enclosureFanFQDDThe fan's Fully Qualified Device Descriptor (FQDD)
as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.21enclosureFanDisplayNameThe fan's friendly FQDD as represented in
Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.4enclosureFanStateThe current state of this fan.
Possible states:
1: The current state could not be determined.
2: The fan is operating normally.
3: The fan has encountered a hardwa…
1.3.6.1.4.1.674.10892.5.4.1100.80.1.1pCIDevicechassisIndex1100.0080.0001.0001 This attribute defines the index (one based) of the
associated system chassis.
1.3.6.1.4.1.674.10892.5.4.1100.80.1.9pCIDeviceDescriptionName1100.0080.0001.0009 This attribute defines the description of the PCI device.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10771alertNetworkConfigurationInformationalertNetworkConfigurationInformation NOTIFICATION-TYPE
OBJECTS { alertMessageID,
alertMessage,
alertCurrentStatus,
alertSystemServiceTag,
alertSystemFQDN,
aler…
1.3.6.1.4.1.674.10892.5.4.600.12.1.12powerSupplyConfigurationErrorType0600.0012.0001.0012 This attribute defines the type of configuration error
reported by the power supply sensor. When the configurationError bit is on
in the val…
1.3.6.1.4.1.674.10892.5.4.600.12.1powerSupplyTableEntry0600.0012.0001 This object defines the Power Supply Table Entry.
1.3.6.1.4.1.674.10892.5.4.700.10.1.6coolingDeviceCountForRedundancy0700.0010.0001.0006 This attribute defines the total number of cooling devices
required for this cooling unit to have full redundancy.
1.3.6.1.4.1.674.10892.5.4.700.10.1coolingUnitTableEntry0700.0010.0001 This object defines the Cooling Unit Table Entry.
1.3.6.1.4.1.674.10892.5.4.300.40.1.2eventLogRecordIndex0300.0040.0001.0002 This attribute defines the index (one based) of the
event log record.
1.3.6.1.4.1.674.10892.5.4.300.40.1eventLogTableEntry0300.0040.0001 This object defines the Event (ESM) Log Table Entry.
1.3.6.1.4.1.674.10892.5.4.300.60firmwareTable0300.0060 This object defines the Firmware Table.
1.3.6.1.4.1.674.10892.5.4.300.10chassisInformationTable0300.0010 This object defines the Chassis Information Table.
1.3.6.1.4.1.674.10892.5.2.4systemPowerStateThis attribute defines the power state of the system.
1.3.6.1.4.1.674.10892.5.2statusGroup
1.3.6.1.4.1.674.10892.5.3.2.1.0.2090alertNetworkWarningalertNetworkWarning NOTIFICATION-TYPE
OBJECTS { alertMessageID,
alertMessage,
alertCurrentStatus,
alertSystemServiceTag,
alertSystemFQDN,
alertFQDD,
alertDevic…
1.3.6.1.4.1.674.10892.5.1.1.3racDescriptionThis attribute defines the product description of a remote access
card.
1.3.6.1.4.1.674.10892.5.1.1racInfoGroup
1.3.6.1.4.1.674.10892.5.4.1100.30.1.18processorDeviceCoreEnabledCount1100.0030.0001.0018 This attribute defines the number of processor cores
enabled for the processor device.
1.3.6.1.4.1.674.10892.5.4.2000.10.1.12fruFQDD2000.0010.0001.0012 Fully qualified device descriptor (FQDD) of the
field replaceable unit.
1.3.6.1.4.1.674.10892.5.4.2000.10.1fruTableEntry2000.0010.0001 This object defines the Field Replaceable Unit table entry.
1.3.6.1.4.1.674.10892.5.4.600.50.1.4systemBatteryStateSettings0600.0050.0001.0004 This attribute defines the state settings of the battery.
1.3.6.1.4.1.674.10892.5.4.600.50.1systemBatteryTableEntry0600.0050.0001 This object defines the System Battery Table Entry.
1.3.6.1.4.1.674.10892.5.4.200.10.1.16systemStateAmperageStatusDetails0200.0010.0001.0016 This attribute lists the status of each amperage probe
of this system. The results are returned as a binary octet string where
each byte of …
1.3.6.1.4.1.674.10892.5.3.2.1systemAlertTrapGroup
1.3.6.1.4.1.674.10892.5.3.2alertTrapGroup
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1enclosurePowerSupplyTableEntryAn entry in the power supply unit table. A row in this table cannot
be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9enclosurePowerSupplyTableA table of managed Power Supply Units(PSU) in the external
storage enclosure(s). The number of entries is related to number
of power supply unit(s) discovered in…
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1enclosurePowerSupplyNumberInstance number of this power supply unit.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.15enclosurePowerSupplyFQDDThe power supply unit's Fully Qualified Device Descriptor (FQDD)
as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.16enclosurePowerSupplyDisplayNameThe power supply unit's friendly FQDD as represented in
Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2enclosurePowerSupplyNameThe power supply unit's name as represented in
Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4enclosurePowerSupplyStateThe current state of this power supply unit.
Possible states:
1: The current state could not be determined.
2: The power supply unit is operating normally.
3: The …
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.7enclosurePowerSupplyPartNumberThe part number of the power supply unit.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9enclosurePowerSupplyComponentStatusThe status of the power supply unit itself without the
propagation of any contained component status.
Possible values:
1: Other.
2: Unknown.
3: OK.
4: Non-critical .
…
1.3.6.1.4.1.674.10892.5.5.1software
1.3.6.1.4.1.674.10892.5.5storageDetailsGroup
1.3.6.1.4.1.674.10892.5.5.1.20storageManagement
1.3.6.1.4.1.674.10892.5.4.200.10.1.26systemStateMemoryDeviceStateDetails0200.0010.0001.0026 This attribute lists the state settings of each
memory device of this system. The results are returned as a binary octet
string where each b…
1.3.6.1.4.1.674.10892.5.4.2000.10.1.9fruRevisionName2000.0010.0001.0009 This attribute defines the revision of the
field replaceable unit.
1.3.6.1.4.1.674dell, dellEnterpriseDell Computer Corporation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2379alertSystemEventLogInformationalertSystemEventLogInformation NOTIFICATION-TYPE
OBJECTS { alertMessageID,
alertMessage,
alertCurrentStatus,
alertSystemServiceTag,
alertSystemFQDN,
alertFQDD,
…
1.3.6.1.4.1.674.10892.5.4.1100.90.1.3networkDeviceStatus1100.0090.0001.0003 This attribute defines the status of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.22processorDeviceExtendedSettings1100.0030.0001.0022 This attribute defines extended settings of the
processor device. This attribute is a bit field where a bit has the meaning
defined below wh…
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.9enclosureTemperatureProbeMaxWarningValueThe maximum temperature that will force the probe into
a warning state.
1.3.6.1.4.1.674.10892.5.4.200.10.1.58systemStateIDSDMCardUnitStatusCombined0200.0010.0001.0058 This attribute defines the combined status
of all IDSDM Card units of this system.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4331alertStorageControllerInformationalertStorageControllerInformation NOTIFICATION-TYPE
OBJECTS { alertMessageID,
alertMessage,
alertCurrentStatus,
alertSystemServiceTag,
alertSystemFQDN,
alertFQ…
1.3.6.1.4.1.674.10892.5.5.1.20.130.13enclosureManagementModuleTableA table of managed Enclosure Management Modules (EMM)
in the external storage enclosure(s). The number of
entries is related to number of enclosure management mo…