Objects in IDRAC-MIB
OID records
| OID | Name | Description |
|---|---|---|
| 1.3.6.1.4.1.674.10892.5.4.2000.10.1.2 | fruIndex | 2000.0010.0001.0002 This attribute defines the index (one based) of the field replaceable unit. |
| 1.3.6.1.4.1.674.10892.5.4.2000.10.1.3 | fruInformationStatus | 2000.0010.0001.0003 This attribute defines the status of the field replaceable unit information. |
| 1.3.6.1.4.1.674.10892.5.4.2000.10.1.6 | fruManufacturerName | 2000.0010.0001.0006 This attribute defines the manufacturer of the field replaceable unit. |
| 1.3.6.1.4.1.674.10892.5.4.2000.10.1.7 | fruSerialNumberName | 2000.0010.0001.0007 This attribute defines the serial number of the field replaceable unit. |
| 1.3.6.1.4.1.674.10892.5.4.2000.10.1.8 | fruPartNumberName | 2000.0010.0001.0008 This attribute defines the part number of the field replaceable unit. |
| 1.3.6.1.4.1.674.10892.5.4.700.20.1.4 | temperatureProbeStateSettings | 0700.0020.0001.0004 This attribute defines the state settings of the temperature probe. |
| 1.3.6.1.4.1.674.10892.5.4.200.10.1.50 | systemStateProcessorDeviceStatusCombined | 0200.0010.0001.0050 This attribute defines the combined status of all processor devices of this system. |
| 1.3.6.1.4.1.674.10892.5.4.700.20.1.6 | temperatureProbeReading | 0700.0020.0001.0006 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete. When the value for temperature… |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.1 | enclosureManagementModuleNumber | Instance number of this enclosure management module. |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.11 | enclosureManagementModuleComponentStatus | The status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-… |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.16 | enclosureManagementModuleDisplayName | The enclosure management module's friendly FQDD as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.2 | enclosureManagementModuleName | The enclosure management module's name as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.4 | enclosureManagementModuleState | The current state of this enclosure management module. Possible states: 1: The current state could not be determined. 2: The enclosure management module is operat… |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.6 | enclosureManagementModulePartNumber | The part number of the enclosure management module. |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.8 | enclosureManagementModuleFWVersion | Firmware version of the enclosure management module. |
| 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10 | processorDeviceFamily | 1100.0030.0001.0010 This attribute defines the family of the processor device. |
| 1.3.6.1.4.1.674.10892.5.4.700.20 | temperatureProbeTable | 0700.0020 This object defines the Temperature Probe Table. |
| 1.3.6.1.4.1.674.10892.5.4.700 | thermalGroup | |
| 1.3.6.1.4.1.674.10892.5.4.700.20.1.13 | temperatureProbeLowerCriticalThreshold | 0700.0020.0001.0013 This attribute defines the lower critical threshold of the temperature probe. The value is an integer representing the temperature of the th… |
| 1.3.6.1.4.1.674.10892.5.4.200.10.1.2 | systemStateGlobalSystemStatus | 0200.0010.0001.0002 This attribute defines the global system status of all system chassis being monitored by the systems management software. |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.83 | controllerBootModeSupported | Indicates whether headless boot mode settings are supported on the controller. |
| 1.3.6.1.4.1.674.10892.5.3.2.4.0.8594 | alertDebugWarning | alertDebugWarning NOTIFICATION-TYPE OBJECTS { alertMessageID, alertMessage, alertCurrentStatus, alertSystemServiceTag, alertSystemFQDN, alertFQDD, alertDeviceD… |
| 1.3.6.1.4.1.674.10892.5.4.1200.10 | systemSlotTable | 1200.0010 This object defines the System Slot Table. |
| 1.3.6.1.4.1.674.10892.5.4.1200 | slotGroup | |
| 1.3.6.1.4.1.674.10892.5.4.200.10.1.54 | systemStateSDCardUnitStatusCombined | 0200.0010.0001.0054 This attribute defines the combined status of all SD Card units of this system. |
| 1.3.6.1.4.1.674.10892.5.4.300.10.1.29 | chassisIdentifyFlashControlSettings | 0300.0010.0001.0029 This attribute setting causes the system front panel LED to flash. |
| 1.3.6.1.4.1.674.10892.5.4.600.12.1.15 | powerSupplyFQDD | 0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power supply. |
| 1.3.6.1.4.1.674.10892.5.4.200.10.1.60 | systemStateIDSDMCardDeviceStatusCombined | 0200.0010.0001.0060 This attribute defines the combined status of all IDSDM Card devices of this system. |
| 1.3.6.1.4.1.674.10892.5.4.700.12.1.5 | coolingDeviceStatus | 0700.0012.0001.0005 This attribute defines the probe status of the cooling device. |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.3 | physicalDiskManufacturer | The name of the physical disk's manufacturer. |
| 1.3.6.1.4.1.674.10892.5.4.600.10.1.1 | powerUnitchassisIndex | 0600.0010.0001.0001 This attribute defines the index (one based) of the system chassis. |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.8 | enclosureTemperatureProbeMinCriticalValue | The minimum temperature that will force the probe into a error state. |
| 1.3.6.1.4.1.674.10892.5.1.1.6 | racURL | This attribute defines the out-of-band UI URL of a remote access card. |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.52 | physicalDiskSecurityStatus | The security/encryption status of the physical disk. Possible Values: 1: Not one of the following. 2: The physical disk does not support encryption 3: The physical… |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.20 | batteryFQDD | The battery's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. |
| 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.70 | controllerCheckConsistencyMode | The current check consistency mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Normal check co… |
| 1.3.6.1.4.1.674.10892.5.4.700.12.1.14 | coolingDeviceLowerNonRecoverableThreshold | 0700.0012.0001.0014 This attribute defines the lower nonrecoverable threshold of the cooling device. The value is an integer representing fan speed in revolutio… |
| 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 | processorDeviceIndex | 1100.0030.0001.0002 This attribute defines the index (one based) of the processor device. |
| 1.3.6.1.4.1.674.10892.5.4.300.60.1.8 | firmwareTypeName | 0300.0060.0001.0008 This attribute defines the type name of the firmware. |
| 1.3.6.1.4.1.674.10892.5.4.300.60.1.1 | firmwarechassisIndex | 0300.0060.0001.0001 This attribute defines the index (one based) of the associated system chassis. |
| 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9 | processorDeviceStatusState | 1100.0030.0001.0009 This attribute defines the status state of the processor device. |
| 1.3.6.1.4.1.674.10892.5.4.1100.50.1.10 | memoryDeviceBankLocationName | 1100.0050.0001.0010 This attribute defines the location of the bank for the memory device. |
| 1.3.6.1.4.1.674.10892.5.4.600.10 | powerUnitTable | 0600.0010 This object defines the Power Unit Table. |
| 1.3.6.1.4.1.674.10892.5.4.600.10.1.2 | powerUnitIndex | 0600.0010.0001.0002 This attribute defines the index (one based) of the power unit. |
| 1.3.6.1.4.1.674.10892.5.4.600.10.1.3 | powerUnitStateCapabilities | 0600.0010.0001.0003 This attribute defines the state capabilities of the power unit. |
| 1.3.6.1.4.1.674.10892.5.4.600.10.1.4 | powerUnitStateSettings | 0600.0010.0001.0004 This attribute defines the state settings of the power unit. |
| 1.3.6.1.4.1.674.10892.5.4.600.10.1.6 | powerSupplyCountForRedundancy | 0600.0010.0001.0006 This attribute defines the total number of power supplies required for this power unit to have full redundancy. |
| 1.3.6.1.4.1.674.10892.5.4.600.10.1.7 | powerUnitName | 0600.0010.0001.0007 This attribute defines the name of the power unit. |
| 1.3.6.1.4.1.674.10892.5.4.600.10.1.8 | powerUnitStatus | 0600.0010.0001.0008 This attribute defines the status of the power unit. |
| 1.3.6.1.4.1.674.10892.5.4.700.10.1.4 | coolingUnitStateSettings | 0700.0010.0001.0004 This attribute defines the state settings of the cooling unit. |