Objects in INTERFACES-MIB

OID records

OIDNameDescription
1.3.6.1.4.1.425.8.12.1.1.2unitUtilitiesFarIndexSelects the far device.
1.3.6.1.4.1.425.8.12.1.1.3unitUtilitiesLocalPasswordThe password for local access to a device (VT100, front panel).
1.3.6.1.4.1.425.8.12.1.1.4unitUtilitiesTimeThis string is the current time as known to the device. The current time may be entered in this field using the HHMMSS format. For example, 3:45AM is entered…
1.3.6.1.4.1.425.8.12.1.1.5unitUtilitiesDateThis string is the current date as known to the device. The current date may be entered in this field using the MMDDYY format. For example, July 4, 1997 is e…
1.3.6.1.4.1.425.8.12.1.1.6unitUtilitiesMaintenanceResetThis field allows resetting the device to default values by reloading the start-up default configuration parameters.
1.3.6.1.4.1.425.8.12.1.1.7unitUtilitiesAlarmResetTimerThis field allows setting a timer which will cause all existing alarms on the device to be cleared upon expiration. The counter is in seconds.
1.3.6.1.4.1.425.8.12.1.1.8unitUtilitiesAlarmClearWriting a 2 to this field causes all existing alarms to be cleared immediatedly.
1.3.6.1.4.1.425.8.8.1.1.7bertElapsedTimeDisplays the amount of time elapsed since a timed test began in seconds.
1.3.6.1.4.1.425.8.8.1.1bertTableEntryAn entry in the BERT control table.
1.3.6.1.4.1.425.8.7.1.1.1connectionNearIndexSelects the near device.
1.3.6.1.4.1.425.8.7.1.1connectionTableEntryAn entry in the connection table.
1.3.6.1.4.1.425.8.9.2.1.7performance30SESThe number of Severely Errored Seconds for the 1-day period.
1.3.6.1.4.1.425.8.5.1.1.16serialDteDTRReports if DTR from the DTE device is false.
1.3.6.1.4.1.425.8.3.1.1.13t1e1ZeroSuppressDetermines whether ones density insertion is activated after 15 zeros . To ensure compliance with TR54016, this field must be enabled.
1.3.6.1.4.1.425.8.3.2.1.28t1e1BPVSThresholdSets the Bipolar Violation Error seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to…
1.3.6.1.4.1.425.8.3.2t1e1AlarmTableThe T1 and E1 Alarm Table.
1.3.6.1.4.1.425.8.3.2.1.10t1e1SESStatusReports if a Severely Errorred condition exists.
1.3.6.1.4.1.425.8.3.2.1.11t1e1SESCountThis count contains the number of consecutive seconds a Severely Errored condition has existed.
1.3.6.1.4.1.425.8.3.2.1.12t1e1SESThresholdSets the Severely Errored seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.425.8.3.2.1.13t1e1SESAlarmThis status indicates if the Severely Errors Seconds threshold is exceeded.
1.3.6.1.4.1.425.8.3.2.1.14t1e1LOSSStatusReports if a Loss of Signal condition exists.
1.3.6.1.4.1.425.8.3.2.1.15t1e1LOSSCountThis count contains the number of consecutive seconds a Loss of Signal condition has existed.
1.3.6.1.4.1.425.8.3.2.1.17t1e1LOSSAlarmThis status indicates if the Loss of Signal Seconds threshold is exceeded.
1.3.6.1.4.1.425.8.3.2.1.18t1e1UASStatusReports if an Unavailable condition exists.
1.3.6.1.4.1.425.8.3.2.1.19t1e1UASCountThis count contains the number of consecutive seconds an Unavailable condition has existed.
1.3.6.1.4.1.425.8.3.2.1.2t1e1AlarmFarIndexSelects the far device.
1.3.6.1.4.1.425.8.3.2.1.20t1e1UASThresholdSets the unavailable seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.425.8.3.2.1.21t1e1UASAlarmThis status indicates if the Unavailable Seconds threshold is exceeded.
1.3.6.1.4.1.425.8.3.2.1.22t1e1CSSStatusReports if a Controlled Slip condition exists.
1.3.6.1.4.1.425.8.3.2.1.23t1e1CSSCountThis count contains the number of consecutive seconds in which at least one Controlled Slip occurred.
1.3.6.1.4.1.425.8.3.2.1.24t1e1CSSThresholdSets the Controlled Slip seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.425.8.3.2.1.25t1e1CSSAlarmThis status indicates if the Controlled Slip seconds threshold is exceeded.
1.3.6.1.4.1.425.8.3.2.1.26t1e1BPVSStatusReports if a Bipolar Violation Error condition exists.
1.3.6.1.4.1.425.8.3.2.1.27t1e1BPVSCountThis count contains the number of consecutive seconds a Bipolar Violation Error condition has existed.
1.3.6.1.4.1.425.8.3.2.1.29t1e1BPVSAlarmThis status indicates if the Bipolar Violation Error seconds threshold is exceeded.
1.3.6.1.4.1.425.8.3.2.1.3t1e1AlarmIndexThis object is the index into the t1e1Table.
1.3.6.1.4.1.425.8.3.2.1.30t1e1OOFSStatusIndicates that the unit is unable to synchronize on the incoming framing pattern.
1.3.6.1.4.1.425.8.3.2.1.31t1e1OOFSCountThis count contains the number of consecutive seconds an OOF condition has existed.
1.3.6.1.4.1.425.8.3.2.1.32t1e1OOFSThresholdSets the OOF seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.425.8.3.2.1.33t1e1OOFSAlarmIndicates if an OOF seconds alarm condition exists.
1.3.6.1.4.1.425.8.3.2.1.34t1e1AISStatusIndicates that the unit is receiving an unframed all ones pattern.
1.3.6.1.4.1.425.8.3.2.1.35t1e1AISCountThis count contains the number of consecutive seconds an Unframed All Ones condition has existed.
1.3.6.1.4.1.425.8.3.2.1.36t1e1AISThresholdSets the AIS seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.425.8.3.2.1.37t1e1AISAlarmIndicates if an Unframed All Ones alarm condition exists.
1.3.6.1.4.1.425.8.3.2.1.38t1e1RASStatusReports if a Remote (Yellow) Alarm condition exists.
1.3.6.1.4.1.425.8.3.2.1.39t1e1RASCountThis count contains the number of consecutive seconds a Remote (Yellow) Alarm condition has existed.
1.3.6.1.4.1.425.8.3.2.1.4t1e1StatusSummaryThis object provides a summary of the port status.
1.3.6.1.4.1.425.8.3.2.1.40t1e1RASThresholdSets the RAS seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900.
1.3.6.1.4.1.425.8.3.2.1.41t1e1RASAlarmThis status indicates if a Remote (Yellow) Alarm exists.
1.3.6.1.4.1.425.8.3.2.1.42t1e1AlarmResetTimerSets the Alarm Reset Timer, this field can be set to any value in the range 0 to 900.