Objects in INTERFACES-MIB

OID records

OIDNameDescription
1.3.6.1.4.1.425.8.11.1.1.6traplogTimeStampTime the SNMP was generated.
1.3.6.1.4.1.425.8.11.1.1.7traplogDeviceTypeSpecifies the device type for the trap.
1.3.6.1.4.1.425.8.8.1.1.8bertBitErrorsDisplays the total number of bit errors detected since the test began.
1.3.6.1.4.1.425.8.10.1.1.8iStatusStatus of the interface.
1.3.6.1.4.1.425.8.4.2.1.9ddsNetLOSAlarmThis status indicates if the Loss of Signal Seconds threshold is exceeded.
1.3.6.1.4.1.425.8.4.2.1.15ddsNetOOSCountThis count contains the number of consecutive seconds the unit has received the out of service code.
1.3.6.1.4.1.425.8.5.1.1.3serialDteConfigIndexIndex into the DteTable.
1.3.6.1.4.1.425.8.3.1.1.8t1e1LineBuildOutSelects the line build out for the network interface. The options are:
t1e1LineBuildOut0db indicates a line build out of 0db
t1e1LineBuildOut75db indicate…
1.3.6.1.4.1.425.8.5.1.1.18serialDteV54Specifies if the unit should respond to inband V.54 loop commands.
1.3.6.1.4.1.425.8.3.1.1.6t1e1FrameTypeSelects the framing for the network side of the DSU/CSU.
1.3.6.1.4.1.425.8.5.2.1.10serialDteASCThresholdThe number of ASC seconds that must be received before an alarm is declared.
1.3.6.1.4.1.425.8.8.1.1.9bertErroredSecondsDisplays the number of asynchronous errored seconds that have been detected since the test began.
1.3.6.1.4.1.425.8.2.1.1.8dbuNumberThis string is the currently programmed number
for the dial backup unit to call
1.3.6.1.4.1.425.8.4.2.1.5ddsNetAlarmSummaryThis object provides a summary of the port alarms.
1.3.6.1.4.1.425.8.10.1iTableThe interface table.
1.3.6.1.4.1.425.8.10itable
1.3.6.1.4.1.425.8.2.1.1.9dbuStatusThis object is the identifier of the current
Dial Backup Unit operating status.
The values mean:
dbuStatusDisabled
The dial backup unit is either not
installed or d…
1.3.6.1.4.1.425.8.8.3.1.2testFarIndexSelects the far device.
1.3.6.1.4.1.425.8.8.3.1.3testTableIndexThe index into the testTable, one entry for each interface.
1.3.6.1.4.1.425.8.8.3.1.4testTypeIdentifies the test type for the interface.
1.3.6.1.4.1.425.8.8.3.1.6testFarLLBFramingThis setting, for Far LLB tests on T1 lines, must match the far end unit loop code framing.
1.3.6.1.4.1.425.8.10.1.1.1iTableNearIndexSelects the near device.
1.3.6.1.4.1.425.8.5.2.1.7serialDteAlarmSummaryThis object provides a summary of the port alarms.
1.3.6.1.4.1.425.8.5.2.1.1serialDteAlarmNearIndexSelects the near device.
1.3.6.1.4.1.425.8.5.2.1.15serialDteFDLAlarmThis status indicates if the FDL Errored Seconds threshold is exceeded.
1.3.6.1.4.1.425.8.5.2.1.18serialDteLOSThresholdThe number of LOS seconds that must be received before an alarm is declared.
1.3.6.1.4.1.425.8.5.2.1.19serialDteLOSAlarmThis status indicates if the LOS Seconds threshold is exceeded.
1.3.6.1.4.1.425.8.5.2.1.4serialDteDTRAlarmControlSpecifies if the unit should alarm on loss of DTR.
1.3.6.1.4.1.425.8.5.2.1.5serialDteDTRAlarmStatusThis status indicates a DTR Loss alarm is active.
1.3.6.1.4.1.425.8.5.2.1.8serialDteASCStatusReports if an ASC condition exists on the interface.
1.3.6.1.4.1.425.8.5.2.1.9serialDteASCCountThis count contains the number of ASC seconds received by the interface.
1.3.6.1.4.1.425.1companyinfo
1.3.6.1.4.1.425.8.2.1.1.19dbuISDNSwitchTypedbuISDNSwitchtype
1.3.6.1.4.1.425.8.9.2.1.1performance30NearIndexSelects the near device.
1.3.6.1.4.1.425.8.2.3.1.6dbuStopThis object is the end of an allowable window for Dial Backup Activation.
1.3.6.1.4.1.425.8.7.2.1.7channelInterfaceChannelDisplays the corresponding channel of the interface channel connection.
1.3.6.1.4.1.425.8.9.2.1.11performance30CRCESThe number of CRC Errored Seconds for the 1-day period.
1.3.6.1.4.1.425.8.2.1.1.13dbuDialStrThis string is the dial string sent to the dial backup unit during every connection attempt
1.3.6.1.4.1.425.8.3.1.1.14t1e1NationalBitSelects a national bit to create a 4-kpbs datalink between the endpoint units.
1.3.6.1.4.1.425.8.2.2dbuResetStringsTableA table of COLD START reprogramming strings for the dial backup unit.
1.3.6.1.4.1.425.8.9.2.1.3performance30InterfaceIndexSelects the interface.
1.3.6.1.4.1.425.8.5.1.1.8serialDteFormatThis variable describes the current operations format
of the DTE interface. The values mean:
serialDteFormatSync
The DTE interface is currently set to operate
in S…
1.3.6.1.4.1.425.8.9.2.1.2performance30FarIndexSelects the far device.
1.3.6.1.4.1.425.8.2.3dbuStartStopTableThe Dial Backup StartStop Table.
1.3.6.1.4.1.425.8.9.1.1.12performance24OOFSThe number of Out of Frame Seconds for the 15-minute period.
1.3.6.1.4.1.425.8.5.1.1.4serialDteDescriptionContains a textual description of the port.
1.3.6.1.4.1.425.7utilities
1.3.6.1.4.1.425.8.9.2.1.9performance30LOFCThe number of Loss of Frame Counts for the 1-day period.
1.3.6.1.4.1.425.8.5.1.1.12serialDteDSRSelects DSR behavior.
1.3.6.1.4.1.425.8.5.1.1.23serialDteTxClockSpecifies how the interface derives its transmit clock.