-- **************************************************************************** -- :CPQ,DEV: -- -- * POWER DEVICE SNMP MANAGEMENT CARD MIB DEFINITIONS -- -- * $Date: 2009/11/19 11:10:00 $ -- * $Revision: 1.62 $ -- Revised by Brian Vo -- Hewlett-Packard Company -- Confidential - Need To Know -- :CPQ,ENDDEV: -- **************************************************************************** -- -- Power Device SNMP Management Card -- Management Information Base for SNMP Network Management -- -- -- Copyright 2001,2005 Hewlett-Packard Development Company, L.P. -- -- Hewlett-Packard Company shall not be liable for technical or -- editorial errors or omissions contained herein. The information in -- this document is provided "as is" without warranty of any kind and -- is subject to change without notice. The warranties for HP products -- are set forth in the express limited warranty statements -- accompanying such products. Nothing herein should be construed as -- constituting an additional warranty. -- -- Confidential computer software. Valid license from HP required for -- possession, use or copying. Consistent with FAR 12.211 and 12.212, -- Commercial Computer Software, Computer Software Documentation, and -- Technical Data for Commercial Items are licensed to the U.S. -- Government under vendor's standard commercial license. -- -- Refer to the READMIB.RDM file for more information about the -- organization of the information in the Compaq Enterprise. -- -- The Compaq Enterprise number is 232. -- The ASN.1 prefix to, and including the Compaq Enterprise is: -- 1.3.6.1.4.1.232 -- -- -- MIB Version 1.0 -- -- ********************************************************************* -- :CPQ,DEV: -- Release History -- Date: October 25, 2005 (version 1.0) - Phi Nguyen -- Date: December 05, 2005 (version 1.2) - Phi Nguyen -- Date: Jan 17, 2008 (version 1.31) Add PDR - Brian Vo -- Date: Feb 25, 2008 (version 1.40) Add Type 19 and trigger TestTrap - Brian Vo -- Date: May 20, 2009 (version 1.61) Add new Modular PDU - Brian Vo -- Date: Nov 19, 2009 (version 1.62) Add Input Rating, Redundant Status -Brian Vo -- -- :CPQ,ENDDEV: -- ********************************************************************* -- -- VARIABLES REQUIRED FOR HP MANAGEMENT -- =================================================================================== -- -- =================================================================================== -- sysDescr (1.3.6.1.2.1.1.1) which is defined in RFC1213.MIB. -- sysContact (1.3.6.1.2.1.1.4) which is defined in RFC1213.MIB. -- sysName (1.3.6.1.2.1.1.5) is which is defined in RFC1213.MIB. -- sysLocation (1.3.6.1.2.1.1.6) which is defined in RFC1213.MIB. -- -- sysDescr OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..255)) -- ACCESS read-only -- STATUS mandatory -- -- -- DESCRIPTION -- "A textual description of the entity. This value -- should include the full name and version -- identification of the system's hardware type, -- software operating-system, and networking -- software. It is mandatory that this only contain -- printable ASCII characters." -- ::= { system 1 } -- -- sysContact OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..255)) -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "The textual identification of the contact person -- for this managed node, together with information -- on how to contact this person." -- ::= { system 4 } -- -- sysName OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..255)) -- -- -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "An administratively-assigned name for this -- managed node. By convention, this is the node's -- fully-qualified domain name." -- ::= { system 5 } -- -- sysLocation OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..255)) -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "The physical location of this node (e.g., -- `telephone closet, 3rd floor')." -- ::= { system 6 } -- =================================================================================== -- -- =================================================================================== -- cpqSiProductName (1.3.6.1.4.1.232.2.2.4.2) which is defined in CPQSINFO.MIB. -- This is the PDU/UPS management module product model name -- (Defined but not used by SIM) -- -- cpqSiProductName OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..255)) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "This device product name." -- ::= { cpqSiSystemBoard 2 } -- ==================================================================================== -- -- ==================================================================================== -- cpqSiSysSerialNum (1.3.6.1.4.1.232.2.2.2.1) which is defined in CPQSINFO.MIB. -- This is the PDU/UPS management module serial number -- (Defined but not used by SIM) -- -- cpqSiSysSerialNum OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..255)) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The serial number of the system unit. -- -- The string will be empty if the system does not report the -- serial number function." -- ::= { cpqSiAsset 1 } -- ==================================================================================== -- -- ==================================================================================== -- cpqHoGUID (1.3.6.1.4.1.232.11.2.10.3) which is defined in CPQHOST.MIB -- This field needs to be filled with the unique -- PDU/UPS management module serial number (16 bytes) -- -- cpqHoGUID OBJECT-TYPE -- SYNTAX OCTET STRING (SIZE (16)) -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "The globally unique identifier of this device." -- ::= { cpqHoSystemStatus 3 } -- ==================================================================================== -- -- ==================================================================================== -- cpqHoMibStatusArray (1.3.6.1.4.1.232.11.2.10.1) which is defined in CPQHOST.MIB -- Pretty complicated to decipher if you do not have the guide. We only use the first -- 4 octets. -- -- Octet 0 = 00000001 (always) -- Octet 1 = 00000000 through 00000100 depending on Device H/W Condition below -- Octet 2 = 00000001 (always) -- Octet 3 = 00010000 (always decimal 16 see table below) -- -- For example: With a UPS device with OK status, the values of the 4 octets would be: -- -- Octet 0 = 0x01 (fixed) -- Octet 1 = 0x02 (OK overall status) -- Octet 2 = 0x01 (fixed) -- Octet 3 = 0x10 (Device type = 16 for UPS) -- -- cpqHoMibStatusArray OBJECT-TYPE -- SYNTAX OCTET STRING (SIZE (4..256)) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "The MIB Status Array is an array of MIB status structures. Each -- structure is made up of 4 octets. -- -- Array element 0 is the status for all MIBs in the Compaq -- Enterprise. -- -- Device H/W Condition (Octet 1) -- 0 - Not available (e.g. Loss/lack of communication between card and device UPS/PDU) -- 1 - Other (unknown) (mapped to device unknown status) -- 2 - OK (mapped to device normal status/events) -- 3 - Degraded (UPS: device warning status/events -- PDU: overload warning, voltage out of tolerance) -- 4 - Failed (UPS: device critical status/events -- PDU: overload condition) -- -- Detailed Type (octet 3) -- Bits 0-7 Detailed Type, only used if bit 0 in octect 2 is 1. -- -- Type Values for Bits 0-4 (maps to CIM7 types) -- Unknown = 0 -- Server = 1 (yes a duplicate of the server flag) -- Desktop = 2 -- Workstation = 3 -- Portable = 4 -- Router = 5 -- Cluster = 6 -- Printer = 7 -- Switch = 8 (network switch) -- Repeater = 9 -- Remote Access Device = 10 -- Other = 11 -- Management Processor = 12 (rib, RILOE, iLo) -- Rack = 13 -- Enclosure = 14 -- KVM Switch = 15 (IP enabled keyboard video mouse switch). -- UPS = 16 -- Power Distribution Unit = 17 (PDU) -- Environmental Monitor = 18 (eg CMC) -- Power Distribution Rack = 19 (PDR)" -- ::= { cpqHoSystemStatus 1 } -- ==================================================================================== -- All Traps, Objects of CPQPOWER.MIB start with .1.3.6.1.4.1.232.165 CPQPOWER-MIB DEFINITIONS ::= BEGIN IMPORTS compaq FROM CPQHOST-MIB -- enterprises FROM RFC1155-SMI -- IpAddress FROM RFC1155-SMI TimeTicks FROM RFC1155-SMI Gauge FROM RFC1155-SMI Counter FROM RFC1155-SMI DisplayString FROM RFC1213-MIB ifIndex FROM RFC1213-MIB ifDescr FROM RFC1213-MIB sysName FROM RFC1213-MIB sysDescr FROM RFC1213-MIB sysContact FROM RFC1213-MIB sysLocation FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; -- compaq OBJECT IDENTIFIER ::= { enterprises 232 } cpqPower OBJECT IDENTIFIER ::= {compaq 165} -- -- Power device object identifiers -- powerDevice OBJECT IDENTIFIER ::= {cpqPower 1} trapInfo OBJECT IDENTIFIER ::= {powerDevice 1} managementModuleIdent OBJECT IDENTIFIER ::= {powerDevice 2} -- -- PDU object identifiers -- pdu OBJECT IDENTIFIER ::= {cpqPower 2} pduIdent OBJECT IDENTIFIER ::= { pdu 1 } pduInput OBJECT IDENTIFIER ::= { pdu 2 } pduOutput OBJECT IDENTIFIER ::= { pdu 3 } -- -- UPS object identifiers -- ups OBJECT IDENTIFIER ::= {cpqPower 3} upsIdent OBJECT IDENTIFIER ::= { ups 1 } upsBattery OBJECT IDENTIFIER ::= { ups 2 } upsInput OBJECT IDENTIFIER ::= { ups 3 } upsOutput OBJECT IDENTIFIER ::= { ups 4 } upsBypass OBJECT IDENTIFIER ::= { ups 5 } upsEnvironment OBJECT IDENTIFIER ::= { ups 6 } upsTest OBJECT IDENTIFIER ::= { ups 7 } upsControl OBJECT IDENTIFIER ::= { ups 8 } upsConfig OBJECT IDENTIFIER ::= { ups 9 } upsRecep OBJECT IDENTIFIER ::= { ups 10 } upsTopology OBJECT IDENTIFIER ::= { ups 11 } -- -- PDR object identifiers -- pdr OBJECT IDENTIFIER ::= {cpqPower 4} pdrIdent OBJECT IDENTIFIER ::= { pdr 1 } pdrPanel OBJECT IDENTIFIER ::= { pdr 2 } pdrBreaker OBJECT IDENTIFIER ::= { pdr 3 } -- -- MPDU object identifiers -- mpdu OBJECT IDENTIFIER ::= {cpqPower 5} mpduIdent OBJECT IDENTIFIER ::= { mpdu 1 } mpduOutput OBJECT IDENTIFIER ::= { mpdu 2 } mpduDeviceIdent OBJECT IDENTIFIER ::= { mpdu 3 } mpduSmExtBarOutlet OBJECT IDENTIFIER ::= { mpdu 4 } -- ==================================================================================== -- -- powerDevice OBJECT IDENTIFIER ::= {cpqPower 1} -- trapInfo OBJECT IDENTIFIER ::= {powerDevice 1} -- trap information group -- trapCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A number identifying the event for the trap that was sent. Mapped unique trap code per unique event to be used by ISEE's decoder ring." ::= { trapInfo 1 } trapDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A string identifying the event for that last trap that was sent." ::= { trapInfo 2 } trapDeviceMgmtUrl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A string contains the URL for the management software." ::= { trapInfo 3 } trapDeviceDetails OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A string details information about the device, including model, serial number, part number, etc...." ::= { trapInfo 4 } trapDeviceName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A string contains the name of the device." ::= { trapInfo 5 } -- -- Device Traps -- trapCritical TRAP-TYPE ENTERPRISE cpqPower VARIABLES { sysName, trapCode, trapDescription, trapDeviceName, trapDeviceDetails, trapDeviceMgmtUrl } DESCRIPTION "A critical alarm has occurred. Action: Check the Trap Details for more information." --#TYPE "Critical Alarm" --#SEVERITY CRITICAL --#CATEGORY "PowerDevice" ::= 1 trapWarning TRAP-TYPE ENTERPRISE cpqPower VARIABLES { sysName, trapCode, trapDescription, trapDeviceName, trapDeviceDetails, trapDeviceMgmtUrl } DESCRIPTION "A warning alarm has occurred. Action: Check the Trap Details for more information." --#TYPE "Warning Alarm" --#SEVERITY MINOR --#CATEGORY "PowerDevice" ::= 2 trapInformation TRAP-TYPE ENTERPRISE cpqPower VARIABLES { sysName, trapCode, trapDescription, trapDeviceName, trapDeviceDetails, trapDeviceMgmtUrl } DESCRIPTION "An informational alarm has occurred. Action: Check the Trap Details for more information." --#TYPE "Information Alarm" --#SEVERITY INFORMATIONAL --#CATEGORY "PowerDevice" ::= 3 trapCleared TRAP-TYPE ENTERPRISE cpqPower VARIABLES { sysName, trapCode, trapDescription, trapDeviceName, trapDeviceDetails, trapDeviceMgmtUrl } DESCRIPTION "An alarm has cleared. Action: Check the Trap Details for more information." --#TYPE "Cleared Alarm" --#SEVERITY INFORMATIONAL --#CATEGORY "PowerDevice" ::= 4 trapTest TRAP-TYPE ENTERPRISE cpqPower VARIABLES { sysName, trapCode, trapDescription, trapDeviceName, trapDeviceDetails, trapDeviceMgmtUrl } DESCRIPTION "Test trap sent to a trap receiver to check proper reception of traps" --#TYPE "Test Trap" --#SEVERITY INFORMATIONAL --#CATEGORY "PowerDevice" ::= 5 deviceTrapInitialization TRAP-TYPE ENTERPRISE cpqPower VARIABLES { sysName, deviceIdentName } DESCRIPTION "This trap is sent each time a power device is initialized." --#TYPE "Device Initialization" --#SEVERITY INFORMATIONAL --#CATEGORY "PowerDevice" ::= 6 -- ==================================================================================== -- -- powerDevice OBJECT IDENTIFIER ::= {cpqPower 1} -- managementModuleIdent OBJECT IDENTIFIER ::= {powerDevice 2} -- Management module identification group -- deviceManufacturer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The device manufacturer." ::= { managementModuleIdent 1 } deviceModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The device model." ::= { managementModuleIdent 2 } deviceFirmwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The device firmware version(s)." ::= { managementModuleIdent 3 } deviceHardwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The device hardware version." ::= { managementModuleIdent 4 } deviceIdentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A string identifying the device." ::= { managementModuleIdent 5 } devicePartNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The device part number." ::= { managementModuleIdent 6 } deviceSerialNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The device serial number." ::= { managementModuleIdent 7 } deviceMACAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The device MAC address." ::= { managementModuleIdent 8 } -- ==================================================================================== -- -- pdu OBJECT IDENTIFIER ::= {cpqPower 2} -- pduIdent OBJECT IDENTIFIER ::= { pdu 1 } -- PDU identification group -- numOfPdu OBJECT-TYPE SYNTAX INTEGER (0..63) ACCESS read-only STATUS mandatory DESCRIPTION "The number of PDUs." ::= { pduIdent 1 } pduIdentTable OBJECT-TYPE SYNTAX SEQUENCE OF PduIdentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Aggregate Object with number of entries equal to NumOfPdu and including the PduIdent group." ::= { pduIdent 2 } pduIdentEntry OBJECT-TYPE SYNTAX PduIdentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ident table entry containing the name, model, manufacturer, firmware version, part number, etc." INDEX { pduIdentIndex } ::= { pduIdentTable 1 } PduIdentEntry ::= SEQUENCE { pduIdentIndex INTEGER, pduName DisplayString, pduModel DisplayString, pduManufacturer DisplayString, pduFirmwareVersion DisplayString, pduPartNumber DisplayString, pduSerialNumber DisplayString, pduStatus INTEGER, pduControllable INTEGER } pduIdentIndex OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Index for the PduIdentEntry table." ::= { pduIdentEntry 1 } pduName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "The string identify the device." ::= { pduIdentEntry 2 } pduModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The Device Model." ::= { pduIdentEntry 3 } pduManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The Device Manufacturer Name (e.g. Hewlett-Packard)." ::= { pduIdentEntry 4 } pduFirmwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The firmware revision level of the device." ::= { pduIdentEntry 5 } pduPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The device part number." ::= { pduIdentEntry 6 } pduSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The deice serial number." ::= { pduIdentEntry 7 } pduStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- default ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The overall status of the device. A value of OK(2) indicates the device is operating normally. A value of degraded(3) indicates the device is operating with warning indicators. A value of failed(4) indicates the device is operating with critical indicators." ::= { pduIdentEntry 8 } pduControllable OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates whether or not the device is controllable." ::= { pduIdentEntry 9 } -- ==================================================================================== -- -- pdu OBJECT IDENTIFIER ::= {cpqPower 2} -- pduInput OBJECT IDENTIFIER ::= { pdu 2 } -- PDU input group -- pduInputTable OBJECT-TYPE SYNTAX SEQUENCE OF PduInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Aggregate Object with number of entries equal to NumOfPdu and including the PduInput group." ::= {pduInput 1} pduInputEntry OBJECT-TYPE SYNTAX PduInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The input table entry containing the voltage and current for the PDU" INDEX { pduInputIndex } ::= { pduInputTable 1 } PduInputEntry ::= SEQUENCE { pduInputIndex INTEGER, inputVoltage INTEGER, inputCurrent INTEGER } pduInputIndex OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Index for the PduInputEntry table." ::= { pduInputEntry 1} inputVoltage OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Volts ACCESS read-only STATUS mandatory DESCRIPTION "The measured input voltage from the PDU meters in volts." ::= {pduInputEntry 2} inputCurrent OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Amp ACCESS read-only STATUS mandatory DESCRIPTION "The measured input current from the PDU meters in amps." ::= {pduInputEntry 3} -- ==================================================================================== -- -- pdu OBJECT IDENTIFIER ::= {cpqPower 2} -- pduOutput OBJECT IDENTIFIER ::= { pdu 3 } -- PDU Output group -- pduOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF PduOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Aggregate Object with number of entries equal to NumOfPdu and including the PduInput group." ::= {pduOutput 1} pduOutputEntry OBJECT-TYPE SYNTAX PduOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The input table entry containing the name, heat load, current load, power load, firmware, etc." INDEX { pduOutputIndex } ::= { pduOutputTable 1 } PduOutputEntry ::= SEQUENCE { pduOutputIndex INTEGER, pduOutputLoad INTEGER, pduOutputHeat INTEGER, pduOutputPower INTEGER, pduOutputNumBreakers INTEGER } pduOutputIndex OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Index for the PduOutputEntry table." ::= { pduOutputEntry 1} pduOutputLoad OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "The device output load in percent of rated capacity. A value of -1 will be returned if the heat load is unable to be measured." ::= { pduOutputEntry 2 } pduOutputHeat OBJECT-TYPE SYNTAX INTEGER -- Units BTU ACCESS read-only STATUS mandatory DESCRIPTION "The total heat load measured on the PDU in BTUs. A value of -1 will be returned if the heat load is unable to be measured." ::= { pduOutputEntry 3 } pduOutputPower OBJECT-TYPE SYNTAX INTEGER -- Units Watts ACCESS read-only STATUS mandatory DESCRIPTION "The total power load measured on the PDU in watts. A value of -1 will be returned if the power load is unable to be measured." ::= { pduOutputEntry 4 } pduOutputNumBreakers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of breakers for the device. This variable indicates the number of rows in the breakers table." ::= { pduOutputEntry 5 } pduOutputBreakerTable OBJECT-TYPE SYNTAX SEQUENCE OF PduOutputBreakerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of breaker table entries. The number of entries is given by pduOutputNumBreakers ." ::= { pduOutput 2 } pduOutputBreakerEntry OBJECT-TYPE SYNTAX PduOutputBreakerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing information applicable to an breaker." INDEX { pduOutputIndex, breakerIndex } ::= { pduOutputBreakerTable 1 } PduOutputBreakerEntry ::= SEQUENCE { breakerIndex INTEGER, breakerVoltage INTEGER, breakerCurrent INTEGER, breakerPercentLoad INTEGER, breakerStatus INTEGER } breakerIndex OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "The breaker identifier." ::= { pduOutputBreakerEntry 1 } breakerVoltage OBJECT-TYPE SYNTAX INTEGER -- UNITS Volts ACCESS read-only STATUS mandatory DESCRIPTION "The breaker voltage in volts." ::= { pduOutputBreakerEntry 2 } breakerCurrent OBJECT-TYPE SYNTAX INTEGER -- UNITS Amps ACCESS read-only STATUS mandatory DESCRIPTION "The breaker current draw in Amps." ::= { pduOutputBreakerEntry 3 } breakerPercentLoad OBJECT-TYPE SYNTAX INTEGER -- UNITS Percent ACCESS read-only STATUS mandatory DESCRIPTION "The breaker load in percent." ::= { pduOutputBreakerEntry 4 } breakerStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), overloadWarning(2), overloadCritical(3), voltageRangeWarning(4), voltageRangeCritical(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the breaker. A value of normal(1) indicates the breaker is operating normally. A value of overloadWarning(2) indicates the breaker has an overload warning. A value of overloadCritical(3) indicates the breaker is overloaded. A value of voltageRangeWarning(4) indicates the breaker voltage is out of tolerance by 10-20%. A value of voltageRangeCritical(5) indicates the breaker voltage is out of tolerance by more than 20%. Note: Overload status has priority over voltage tolerance status." ::= { pduOutputBreakerEntry 5 } -- ==================================================================================== -- -- ups OBJECT IDENTIFIER ::= {cpqPower 3} -- upsIdent OBJECT IDENTIFIER ::= { ups 1 } -- UPS Identification group -- upsIdentManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "The UPS Manufacturer Name (e.g. Hewlett-Packard)." ::= { upsIdent 1 } upsIdentModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The UPS Model;Part number;Serial number (e.g. HP R5500 XR;204451-B21;B00123456W)." ::= { upsIdent 2 } upsIdentSoftwareVersions OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The firmware revision level(s) of the UPS microcontroller(s)." ::= { upsIdent 3 } upsIdentOemCode OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "A binary code indicating vendor. This should be a ?0x0c? for HP" ::= { upsIdent 4 } -- ==================================================================================== -- -- ups OBJECT IDENTIFIER ::= {cpqPower 3} -- upsBattery OBJECT IDENTIFIER ::= { ups 2 } -- UPS Battery group -- upsBatTimeRemaining OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS seconds ACCESS read-only STATUS mandatory DESCRIPTION "Battery run time in seconds before UPS turns off due to low battery." ::= { upsBattery 1 } upsBatVoltage OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS Volts DC ACCESS read-only STATUS mandatory DESCRIPTION "Battery voltage as reported by the UPS meters." ::= { upsBattery 2 } upsBatCurrent OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) -- UNITS Amp DC ACCESS read-only STATUS mandatory DESCRIPTION "Battery Current as reported by the UPS metering. Current is positive when discharging, negative when recharging the battery." ::= { upsBattery 3 } upsBatCapacity OBJECT-TYPE SYNTAX INTEGER (0..100) -- UNITS percent ACCESS read-only STATUS mandatory DESCRIPTION "Battery percent charge." ::= { upsBattery 4 } upsBatteryAbmStatus OBJECT-TYPE SYNTAX INTEGER { batteryCharging(1), batteryDischarging(2), batteryFloating(3), batteryResting(4), unknown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Gives the status of the Advanced Battery Management; batteryFloating(3) status means that the charger is temporarily charging the battery to its float voltage; batteryResting(4) is the state when the battery is fully charged and none of the other actions (charging/discharging/floating) is being done." ::= { upsBattery 5 } -- ==================================================================================== -- -- ups OBJECT IDENTIFIER ::= {cpqPower 3} -- upsInput OBJECT IDENTIFIER ::= { ups 3 } -- UPS Input group -- upsInputFrequency OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS 0.1 Hertz ACCESS read-only STATUS mandatory DESCRIPTION "The utility line frequency in tenths of Hz." ::= { upsInput 1 } upsInputLineBads OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the Input was out of tolerance in voltage or frequency." ::= { upsInput 2 } upsInputNumPhases OBJECT-TYPE SYNTAX INTEGER (0..6) ACCESS read-only STATUS mandatory ::= { upsInput 3 } upsInputTable OBJECT-TYPE SYNTAX SEQUENCE OF UpsInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Aggregate Object with number of entries equal to NumPhases and including the UpsInput group." ::= { upsInput 4 } upsInputEntry OBJECT-TYPE SYNTAX UpsInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The input table entry containing the current, voltage, etc." INDEX { upsInputPhase } ::= { upsInputTable 1 } UpsInputEntry ::= SEQUENCE { upsInputPhase INTEGER, upsInputVoltage INTEGER, upsInputCurrent INTEGER, upsInputWatts INTEGER } upsInputPhase OBJECT-TYPE SYNTAX INTEGER (0..6) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the phase. Serves as index for input table." ::= { upsInputEntry 1 } upsInputVoltage OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Volts ACCESS read-only STATUS mandatory DESCRIPTION "The measured input voltage from the UPS meters in volts." ::= { upsInputEntry 2 } upsInputCurrent OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Amp ACCESS read-only STATUS mandatory DESCRIPTION "The measured input current from the UPS meters in amps." ::= { upsInputEntry 3 } upsInputWatts OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS Watts ACCESS read-only STATUS mandatory DESCRIPTION "The measured input real power in watts." ::= { upsInputEntry 4 } upsInputSource OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), -- For example, Utility failure primaryUtility(3), -- Normal utility feed to the UPS bypassFeed(4), -- Bypass utility, separate from primaryUtility secondaryUtility(5), -- Secondary utility feed (on a dual AC input UPS) generator(6), -- Power provided by a generator flywheel(7), -- Power provided by a flywheel (not necessarily AC) fuelcell(8) -- Power provided by fuel cell(s) (not necessarily AC) } ACCESS read-only STATUS mandatory DESCRIPTION "The present external source of input power. The enumeration none(2) indicates that there is no external source of power, for example, the UPS is On Battery (an internal source). The bypassFeed(4) can only be used when the Bypass source is known to be a separate utility feed than the primaryUtility(3)." ::= { upsInput 5 } -- ==================================================================================== -- -- ups OBJECT IDENTIFIER ::= {cpqPower 3} -- upsOutput OBJECT IDENTIFIER ::= { ups 4 } -- UPS Output group -- upsOutputLoad OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "The UPS output load in percent of rated capacity." ::= { upsOutput 1 } upsOutputFrequency OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS 0.1 Hertz ACCESS read-only STATUS mandatory DESCRIPTION "The measured UPS output frequency in tenths of Hz." ::= { upsOutput 2 } upsOutputNumPhases OBJECT-TYPE SYNTAX INTEGER (0..6) ACCESS read-only STATUS mandatory DESCRIPTION "The number of metered output phases, serves as the table index." ::= { upsOutput 3 } upsOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF UpsOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Aggregate Object with number of entries equal to NumPhases and including the UpsOutput group." ::= { upsOutput 4 } upsOutputEntry OBJECT-TYPE SYNTAX UpsOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Output Table Entry containing voltage, current, etc." INDEX { upsOutputPhase } ::= { upsOutputTable 1 } UpsOutputEntry ::= SEQUENCE { upsOutputPhase INTEGER, upsOutputVoltage INTEGER, upsOutputCurrent INTEGER, upsOutputWatts INTEGER } upsOutputPhase OBJECT-TYPE SYNTAX INTEGER (0..6) ACCESS read-only STATUS mandatory DESCRIPTION "The number {1..3} of the output phase." ::= { upsOutputEntry 1 } upsOutputVoltage OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Volts ACCESS read-only STATUS mandatory DESCRIPTION "The measured output voltage from the UPS metering in volts." ::= { upsOutputEntry 2 } upsOutputCurrent OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Amp ACCESS read-only STATUS mandatory DESCRIPTION "The measured UPS output current in amps." ::= { upsOutputEntry 3 } upsOutputWatts OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS Watts ACCESS read-only STATUS mandatory DESCRIPTION "The measured real output power in watts." ::= { upsOutputEntry 4 } upsOutputSource OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), normal(3), -- normal, single UPS module output bypass(4), battery(5), booster(6), -- Single or Double Boost, line-interactive UPSs only reducer(7), -- Buck, line-interactive UPSs only parallelCapacity(8), -- normal enhanced by Parallel for Capacity operation parallelRedundant(9), -- normal enhanced by Redundant Parallel operation highEfficiencyMode(10) -- normal enhanced by High Efficiency mode } ACCESS read-only STATUS mandatory DESCRIPTION "The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker." ::= { upsOutput 5 } -- ==================================================================================== -- -- ups OBJECT IDENTIFIER ::= {cpqPower 3} -- upsBypass OBJECT IDENTIFIER ::= { ups 5 } -- UPS Bypass group -- upsBypassFrequency OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS 0.1 Hertz ACCESS read-only STATUS mandatory DESCRIPTION "The bypass frequency in tenths of Hz." ::= { upsBypass 1 } upsBypassNumPhases OBJECT-TYPE SYNTAX INTEGER (0..6) ACCESS read-only STATUS mandatory DESCRIPTION "The number of lines in the UPS bypass table." ::= { upsBypass 2 } upsBypassTable OBJECT-TYPE SYNTAX SEQUENCE OF UpsBypassEntry ACCESS not-accessible STATUS mandatory ::= { upsBypass 3 } upsBypassEntry OBJECT-TYPE SYNTAX UpsBypassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry in the UpsBypassTable." INDEX { upsBypassPhase } ::= { upsBypassTable 1 } UpsBypassEntry ::= SEQUENCE { upsBypassPhase INTEGER, upsBypassVoltage INTEGER } upsBypassPhase OBJECT-TYPE SYNTAX INTEGER (0..6) ACCESS read-only STATUS mandatory DESCRIPTION "The Bypass Phase, index for the table." ::= { upsBypassEntry 1 } upsBypassVoltage OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Volts ACCESS read-only STATUS mandatory DESCRIPTION "The measured UPS bypass voltage in volts." ::= { upsBypassEntry 2 } -- ==================================================================================== -- -- ups OBJECT IDENTIFIER ::= {cpqPower 3} -- upsEnvironment OBJECT IDENTIFIER ::= { ups 6 } -- UPS Environment group -- upsEnvAmbientTemp OBJECT-TYPE SYNTAX INTEGER (-100..200) -- UNITS Degrees Centigrade ACCESS read-only STATUS mandatory DESCRIPTION "The reading of the ambient temperature in the vicinity of the UPS or SNMP agent." ::= { upsEnvironment 1 } upsEnvAmbientLowerLimit OBJECT-TYPE SYNTAX INTEGER (-100..200) -- UNITS Degrees Centigrade ACCESS read-write STATUS mandatory DESCRIPTION "The Lower Limit of the ambient temperature; if UpsEnvAmbientTemp falls below this value, the UpsAmbientTempBad alarm will occur." ::= { upsEnvironment 2 } upsEnvAmbientUpperLimit OBJECT-TYPE SYNTAX INTEGER (-100..200) -- UNITS Degrees Centigrade ACCESS read-write STATUS mandatory DESCRIPTION "The Upper Limit of the ambient temperature; if UpsEnvAmbientTemp rises above this value, the UpsAmbientTempBad alarm will occur. This value should be greater than UpsEnvAmbientLowerLimit." ::= { upsEnvironment 3 } upsEnvAmbientHumidity OBJECT-TYPE SYNTAX INTEGER (0..100) -- UNITS % ACCESS read-only STATUS mandatory DESCRIPTION "The reading of the ambient humidity in the vicinity of the UPS or SNMP agent." ::= { upsEnvironment 4 } upsEnvRemoteTemp OBJECT-TYPE SYNTAX INTEGER (-100..200) -- UNITS Degrees Centigrade ACCESS read-only STATUS mandatory DESCRIPTION "The reading of a remote temperature sensor connected to the UPS or SNMP agent." ::= { upsEnvironment 5 } upsEnvRemoteHumidity OBJECT-TYPE SYNTAX INTEGER (0..100) -- UNITS % ACCESS read-only STATUS mandatory DESCRIPTION "The reading of a remote humidity sensor connected to the UPS or SNMP agent." ::= { upsEnvironment 6 } -- -- The Environmental Contact Sensing Table -- Contains the table for monitoring all contacts (digital -- inputs). -- upsEnvNumContacts OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "The number of Contacts in the UpsContactsTable. This object indicates the number of rows in the UpsContactsTable." ::= { upsEnvironment 7 } upsContactsTable OBJECT-TYPE SYNTAX SEQUENCE OF UpsContactsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of Contact Sensing table entries. The number of entries is given by the value of UpsEnvNumContacts." ::= { upsEnvironment 8 } upsContactsTableEntry OBJECT-TYPE SYNTAX UpsContactsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing information applicable to a particular Contact input." INDEX { upsContactIndex } ::= { upsContactsTable 1 } UpsContactsTableEntry ::= SEQUENCE { upsContactIndex INTEGER, upsContactType INTEGER, upsContactState INTEGER, upsContactDescr DisplayString } upsContactIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "The Contact identifier; identical to the Contact Number." ::= { upsContactsTableEntry 1 } upsContactType OBJECT-TYPE SYNTAX INTEGER { normallyOpen(1), -- or Input Normally High normallyClosed(2), -- or Input Normally Low anyChange(3), -- No normal Open/Closed state notUsed(4) -- Contact not in service } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state for this contact. The 'other' state is the Active state for generating the UpstdContactActiveNotice trap. If anyChange(3) is selected, then this trap is sent any time the contact changes to either Open or Closed. No traps are sent if the Contact is set to notUsed(4). In many cases, the configuration for Contacts may be done by other means, so this object may be read-only." ::= { upsContactsTableEntry 2 } upsContactState OBJECT-TYPE SYNTAX INTEGER { open(1), closed(2), openWithNotice(3), closedWithNotice(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the Contact input; the value is based on the open/closed input state and the setting for UpsContactType. When entering the openWithNotice(3) and closedWithNotice(4) states, no entries added to the UpsAlarmTable, but the UpstdContactActiveNotice trap is sent." ::= { upsContactsTableEntry 3 } upsContactDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "A label identifying the Contact. This object should be set by the administrator." ::= { upsContactsTableEntry 4 } upsEnvRemoteTempLowerLimit OBJECT-TYPE SYNTAX INTEGER (-100..200) -- UNITS Degrees Centigrade ACCESS read-write STATUS mandatory DESCRIPTION "The Lower Limit of the remote temperature; if UpsEnvRemoteTemp falls below this value, the UpsRemoteTempBad alarm will occur." ::= { upsEnvironment 9 } upsEnvRemoteTempUpperLimit OBJECT-TYPE SYNTAX INTEGER (-100..200) -- UNITS Degrees Centigrade ACCESS read-write STATUS mandatory DESCRIPTION "The Upper Limit of the remote temperature; if UpsEnvRemoteTemp rises above this value, the UpsRemoteTempBad alarm will occur. This value should be greater than UpsEnvRemoteTempLowerLimit." ::= { upsEnvironment 10 } upsEnvRemoteHumidityLowerLimit OBJECT-TYPE SYNTAX INTEGER (0..100) -- UNITS % ACCESS read-write STATUS mandatory DESCRIPTION "The Lower Limit of the remote humidity reading; if UpsEnvRemoteHumidity falls below this value, the UpsRemoteHumidityBad alarm will occur." ::= { upsEnvironment 11 } upsEnvRemoteHumidityUpperLimit OBJECT-TYPE SYNTAX INTEGER (0..100) -- UNITS % ACCESS read-write STATUS mandatory DESCRIPTION "The Upper Limit of the remote humidity reading; if UpsEnvRemoteHumidity rises above this value, the UpsRemoteHumidityBad alarm will occur. This value should be greater than UpsEnvRemoteHumidityLowerLimit." ::= { upsEnvironment 12 } -- ==================================================================================== -- -- ups OBJECT IDENTIFIER ::= {cpqPower 3} -- upsTest OBJECT IDENTIFIER ::= { ups 7 } -- UPS Test group -- upsTestBattery OBJECT-TYPE SYNTAX INTEGER { startTest (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to startTest initiates the battery test. All other set values are invalid." ::= { upsTest 1 } upsTestBatteryStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), passed (2), failed (3), inProgress (4), notSupported (5), inhibited (6), scheduled (7) } ACCESS read-only STATUS mandatory DESCRIPTION "Reading this enumerated value gives an indication of the UPS Battery test status." ::= { upsTest 2 } upsTestTrap OBJECT-TYPE SYNTAX INTEGER { startTestTrap (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to startTestTrap initiates a TrapTest is sent out from HPMM. All other set values are invalid." ::= { upsTest 3 } -- ==================================================================================== -- -- ups OBJECT IDENTIFIER ::= {cpqPower 3} -- upsControl OBJECT IDENTIFIER ::= { ups 8 } -- UPS Control group -- upsControlOutputOffDelay OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS seconds ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value to other than zero will cause the UPS output to turn off after the number of seconds. Setting it to 0 will cause an attempt to abort a pending shutdown." ::= { upsControl 1 } upsControlOutputOnDelay OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS seconds ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value to other than zero will cause the UPS output to turn on after the number of seconds. Setting it to 0 will cause an attempt to abort a pending startup." ::= { upsControl 2 } upsControlOutputOffTrapDelay OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS seconds ACCESS read-write STATUS mandatory DESCRIPTION "When UpsControlOutputOffDelay reaches this value, a trap will be sent." ::= { upsControl 3 } upsControlOutputOnTrapDelay OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS seconds ACCESS read-write STATUS deprecated DESCRIPTION "When UpsControlOutputOnDelay reaches this value, a UpsOutputOff trap will be sent." ::= { upsControl 4 } upsControlToBypassDelay OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS seconds ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value to other than zero will cause the UPS output to go to Bypass after the number of seconds. If the Bypass is unavailable, this may cause the UPS to not supply power to the load. Setting it to 0 will cause an attempt to abort a pending shutdown." ::= { upsControl 5 } upsLoadShedSecsWithRestart OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS seconds ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value will cause the UPS output to turn off after the set number of seconds, then restart (after a UPS-defined 'down time') when the utility is again available. Unlike UpsControlOutputOffDelay, which might or might not, this object always maps to the XCP 0x8A Load Dump & Restart command, so the desired shutdown and restart behavior is guaranteed to happen. Once set, this command cannot be aborted. This is the preferred Control object to use when performing an On Battery OS Shutdown." ::= { upsControl 6 } -- ==================================================================================== -- -- ups OBJECT IDENTIFIER ::= {cpqPower 3} -- upsConfig OBJECT IDENTIFIER ::= { ups 9 } -- UPS Config group -- upsConfigOutputVoltage OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Volts ACCESS read-only STATUS mandatory DESCRIPTION "The nominal UPS Output voltage per phase in volts." ::= { upsConfig 1 } upsConfigInputVoltage OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Volts ACCESS read-only STATUS mandatory DESCRIPTION "The nominal UPS Input voltage per phase in volts." ::= { upsConfig 2 } upsConfigOutputWatts OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS Watts ACCESS read-only STATUS mandatory DESCRIPTION "The nominal UPS available real power output in watts." ::= { upsConfig 3} upsConfigOutputFreq OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS 0.1 Hertz ACCESS read-only STATUS mandatory DESCRIPTION "The nominal output frequency in tenths of Hz." ::= { upsConfig 4 } upsConfigDateAndTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..22)) ACCESS read-write STATUS mandatory DESCRIPTION "Date and time information for the UPS. Setting this variable will initiate a set UPS date and time to this value. Reading this variable will return the UPS time and date. This value is not referenced to sysUpTime. It is simply the clock value from the UPS real time clock. Format is as follows: MM/DD/YYYY:HH:MM:SS." ::= { upsConfig 5 } upsConfigLowOutputVoltageLimit OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Volts ACCESS read-only STATUS mandatory DESCRIPTION "The Lower limit for acceptable Output Voltage, per the UPS specifications." ::= { upsConfig 6 } upsConfigHighOutputVoltageLimit OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Volts ACCESS read-only STATUS mandatory DESCRIPTION "The Upper limit for acceptable Output Voltage, per the UPS specifications." ::= { upsConfig 7 } -- ==================================================================================== -- -- ups OBJECT IDENTIFIER ::= {cpqPower 3} -- upsRecep OBJECT IDENTIFIER ::= { ups 10 } -- UPS Recep group -- -- (Note that the terms Receptacle, Outlet, and Load Group are used interchangeably -- here and all mean "one of a set of controllable, power-switched outputs") -- upsNumReceptacles OBJECT-TYPE SYNTAX INTEGER (0..64) ACCESS read-only STATUS mandatory DESCRIPTION "The number of independently controllable Receptacles, as described in the UpsRecepTable." ::= { upsRecep 1 } upsRecepTable OBJECT-TYPE SYNTAX SEQUENCE OF UpsRecepEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Aggregate Object with number of entries equal to NumReceptacles and including the UpsRecep group." ::={ upsRecep 2 } upsRecepEntry OBJECT-TYPE SYNTAX UpsRecepEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Recep table entry, etc." INDEX { upsRecepIndex } ::= { upsRecepTable 1 } UpsRecepEntry ::= SEQUENCE { upsRecepIndex INTEGER, upsRecepStatus INTEGER, upsRecepOffDelaySecs INTEGER, upsRecepOnDelaySecs INTEGER, upsRecepAutoOffDelay INTEGER, upsRecepAutoOnDelay INTEGER, upsRecepShedSecsWithRestart INTEGER } upsRecepIndex OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the Receptacle. Serves as index for Receptacle table." ::= { upsRecepEntry 1 } upsRecepStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), pendingOff(3), pendingOn(4), unknown(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The Recep Status 1=On/Close, 2=Off/Open, 3=On w/Pending Off, 4=Off w/Pending ON, 5=Unknown." ::={ upsRecepEntry 2 } upsRecepOffDelaySecs OBJECT-TYPE SYNTAX INTEGER (-1..2147483647) -- UNITS seconds ACCESS read-write STATUS mandatory DESCRIPTION "The Delay until the Receptacle is turned Off. Setting this value to other than -1 will cause the UPS output to turn off after the number of seconds (0 is immediately). Setting it to -1 will cause an attempt to abort a pending shutdown. When this object is set while the UPS is On Battery, it is not necessary to set UpsRecepOnDelaySecs, since the outlet will turn back on automatically when power is available again." ::= { upsRecepEntry 3 } upsRecepOnDelaySecs OBJECT-TYPE SYNTAX INTEGER (-1..2147483647) -- UNITS seconds ACCESS read-write STATUS mandatory DESCRIPTION " The Delay until the Receptacle is turned On. Setting this value to other than -1 will cause the UPS output to turn on after the number of seconds (0 is immediately). Setting it to -1 will cause an attempt to abort a pending restart." ::={ upsRecepEntry 4 } upsRecepAutoOffDelay OBJECT-TYPE SYNTAX INTEGER (-1..32767) -- UNITS seconds ACCESS read-write STATUS mandatory DESCRIPTION "The delay after going On Battery until the Receptacle is automatically turned Off. A value of -1 means that this Output should never be turned Off automatically, but must be turned Off only by command. Values from 0 to 30 are valid, but probably innappropriate. The AutoOffDelay can be used to prioritize loads in the event of a prolonged power outage; less critical loads will turn off earlier to extend battery time for the more critical loads. If the utility power is restored before the AutoOff delay counts down to 0 on an outlet, that outlet will not turn Off." ::= { upsRecepEntry 5 } upsRecepAutoOnDelay OBJECT-TYPE SYNTAX INTEGER (-1..32767) -- UNITS seconds ACCESS read-write STATUS mandatory DESCRIPTION "Seconds delay after the Outlet is signaled to turn On before the Output is Automatically turned ON. A value of -1 means that this Output should never be turned On automatically, but only when specifically commanded to do so. A value of 0 means that the Receptacle should come On immediately at power-up or for an On command." ::= { upsRecepEntry 6 } -- UpsRecepAutoOnDelay has three purposes: -- 1. To coordinate the automatic startup of various outlets, when the normal -- auto-sequencing of 1 second per outlet is not adequate. For example, they may -- be used to power up hard disk arrays before CPU units are started. -- 2. To force additional 'Down Time' during UpsRecepOffDelaySecs commands, for -- equipment to be reset, when the standard 'Down Time' is not long enough. -- 3. For the -1 value, to ensure that loads won?t be powered until commanded, -- following power-up or a UpsRecepOffDelaySecs command. upsRecepShedSecsWithRestart OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS seconds ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value will cause the UPS output to turn off after the set number of seconds, then restart (after a UPS-defined 'down time') when the utility is again available. Unlike UpsRecepOffDelaySecs, which might or might not, this object always maps to the XCP 0x8A Load Dump & Restart command, so the desired shutdown and restart behavior is guaranteed to happen. Once set, this command cannot be aborted." ::= { upsRecepEntry 7 } -- ==================================================================================== -- -- ups OBJECT IDENTIFIER ::= {cpqPower 3} -- upsTopology OBJECT IDENTIFIER ::= { ups 11 } -- UPS Topology group -- upsTopologyType OBJECT-TYPE SYNTAX INTEGER (0..32767) ACCESS read-only STATUS mandatory DESCRIPTION "Value which denotes the type of UPS by its power topology. Values are the same as those described in the XCP Topology block's Overall Topology field." ::= { upsTopology 1 } upsTopoMachineCode OBJECT-TYPE SYNTAX INTEGER (0..32767) ACCESS read-only STATUS mandatory DESCRIPTION "ID Value which denotes the Compaq/HP model of the UPS for software. Values are the same as those described in the XCP Configuration block's Machine Code field." ::= { upsTopology 2 } upsTopoUnitNumber OBJECT-TYPE SYNTAX INTEGER (0..64) ACCESS read-only STATUS mandatory DESCRIPTION "Identifies which unit and what type of data is being reported. A value of 0 means that this MIB information comes from the top-level system view (eg, manifold module or system bypass cabinet reporting total system output). Standalone units also use a value of 0, since they are the 'full system' view. A value of 1 or higher indicates the number of the module in the system which is reporting only its own data in the HP MIB objects." ::= { upsTopology 3 } upsTopoPowerStrategy OBJECT-TYPE SYNTAX INTEGER { highAlert(1), standard(2), enableHighEfficiency(3), immediateHighEfficiency(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Value which denotes which Power Strategy is currently set for the UPS. The values are: highAlert(1) - The UPS shall optimize its operating state to maximize its power-protection levels. This mode will be held for at most 24 hours. standard(2) - Balanced, normal power protection strategy. UPS will not enter HE operating mode from this setting. enableHighEfficiency(3) - The UPS is enabled to enter HE operating mode to optimize its operating state to maximize its efficiency, when conditions change to permit it (as determined by the UPS). forceHighEfficiency(4) - If this value is permitted to be Set for this UPS, and if conditions permit, requires the UPS to enter High Efficiency mode now, without delay (for as long as utility conditions permit). After successfully set to forceHighEfficiency(4), UpsTopoPowerStrategy changes to value enableHighEfficiency(3). UpsOutputSource will indicate if the UPS status is actually operating in High Efficiency mode." ::= { upsTopology 4 } -- ==================================================================================== -- -- pdr OBJECT IDENTIFIER ::= {cpqPower 4} -- pdrIdent OBJECT IDENTIFIER ::= { pdr 1 } -- PDR identification group -- pdrName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-write STATUS mandatory DESCRIPTION "The string identify the device." ::= { pdrIdent 1 } pdrModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The Device Model." ::= { pdrIdent 2 } pdrManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The Device Manufacturer Name (e.g. Hewlett-Packard)." ::= { pdrIdent 3 } pdrFirmwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The firmware revision level of the device." ::= { pdrIdent 4 } pdrPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The device part number." ::= { pdrIdent 5 } pdrSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The PDR's serial number." ::= { pdrIdent 6 } pdrVARating OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS Volts-amps ACCESS read-only STATUS mandatory DESCRIPTION "The VA Rating of this PDR (all phases)" ::= { pdrIdent 7 } pdrNominalOutputVoltage OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS Volts ACCESS read-only STATUS mandatory DESCRIPTION "The nominal Output Voltage may differ from the nominal Input Voltage if the PDR has an input transformer" ::= { pdrIdent 8 } pdrNumPhases OBJECT-TYPE SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION "The number of phases for this PDR" ::= { pdrIdent 9 } pdrNumPanels OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "The number of panels or subfeeds in this PDR" ::= { pdrIdent 10 } pdrNumBreakers OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "The number of breakers in this PDR" ::= { pdrIdent 11 } -- ==================================================================================== -- -- pdr OBJECT IDENTIFIER ::= {cpqPower 4} -- pdrPanel OBJECT IDENTIFIER ::= { pdr 2 } -- PDR Panel Meters -- pdrPanelTable OBJECT-TYPE SYNTAX SEQUENCE OF PdrPanelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Aggregate Object with number of entries equal to pdrNumPanels" ::= { pdrPanel 1 } pdrPanelEntry OBJECT-TYPE SYNTAX PdrPanelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The panel table entry containing all power parameters for each panel." INDEX { pdrPanelIndex } ::= { pdrPanelTable 1 } PdrPanelEntry ::= SEQUENCE { pdrPanelIndex INTEGER, pdrPanelFrequency INTEGER, pdrPanelPower INTEGER, pdrPanelRatedCurrent INTEGER, pdrPanelMonthlyKWH INTEGER, pdrPanelYearlyKWH INTEGER, pdrPanelTotalKWH INTEGER, pdrPanelVoltageA INTEGER, pdrPanelVoltageB INTEGER, pdrPanelVoltageC INTEGER, pdrPanelCurrentA INTEGER, pdrPanelCurrentB INTEGER, pdrPanelCurrentC INTEGER, pdrPanelLoadA INTEGER, pdrPanelLoadB INTEGER, pdrPanelLoadC INTEGER } pdrPanelIndex OBJECT-TYPE SYNTAX INTEGER (0..10) ACCESS read-only STATUS mandatory DESCRIPTION "Index for the pdrPanelEntry table." ::= { pdrPanelEntry 1} pdrPanelFrequency OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS 0.1 Hertz ACCESS read-only STATUS mandatory DESCRIPTION "The present frequency reading for the panel voltage." ::= { pdrPanelEntry 2 } pdrPanelPower OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- Units 0.1 KW ACCESS read-only STATUS mandatory DESCRIPTION "The present power of the panel." ::= { pdrPanelEntry 3 } pdrPanelRatedCurrent OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- Units 0.1 A ACCESS read-only STATUS mandatory DESCRIPTION "The present rated current of the panel." ::= { pdrPanelEntry 4 } pdrPanelMonthlyKWH OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- Units 0.01 KWH ACCESS read-only STATUS mandatory DESCRIPTION "The accumulated KWH for this panel since the beginning of this calendar month or since the last reset." ::= { pdrPanelEntry 5 } pdrPanelYearlyKWH OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- Units 0.01 KWH ACCESS read-only STATUS mandatory DESCRIPTION "The accumulated KWH for this panel since the beginning of this calendar year or since the last reset." ::= { pdrPanelEntry 6 } pdrPanelTotalKWH OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- Units 0.01 KWH ACCESS read-only STATUS mandatory DESCRIPTION "The accumulated KWH for this panel since it was put into service or since the last reset." ::= { pdrPanelEntry 7 } pdrPanelVoltageA OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS 0.1 V ACCESS read-only STATUS mandatory DESCRIPTION "The measured panel output voltage." ::= {pdrPanelEntry 8} pdrPanelVoltageB OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS 0.1 V ACCESS read-only STATUS mandatory DESCRIPTION "The measured panel output voltage." ::= {pdrPanelEntry 9} pdrPanelVoltageC OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS 0.1 V ACCESS read-only STATUS mandatory DESCRIPTION "The measured panel output voltage." ::= {pdrPanelEntry 10} pdrPanelCurrentA OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS 0.1 A ACCESS read-only STATUS mandatory DESCRIPTION "The measured panel output current." ::= {pdrPanelEntry 11} pdrPanelCurrentB OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS 0.1 A ACCESS read-only STATUS mandatory DESCRIPTION "The measured panel output current." ::= {pdrPanelEntry 12} pdrPanelCurrentC OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS 0.1 A ACCESS read-only STATUS mandatory DESCRIPTION "The measured panel output current." ::= {pdrPanelEntry 13} pdrPanelLoadA OBJECT-TYPE SYNTAX INTEGER (0..200) -- UNITS 0.1 percent ACCESS read-only STATUS mandatory DESCRIPTION "The percentage of load is the ratio of each output current to the rated output current to the panel." ::= {pdrPanelEntry 14} pdrPanelLoadB OBJECT-TYPE SYNTAX INTEGER (0..200) -- UNITS 0.1 percent ACCESS read-only STATUS mandatory DESCRIPTION "The percentage of load is the ratio of each output current to the rated output current to the panel." ::= {pdrPanelEntry 15} pdrPanelLoadC OBJECT-TYPE SYNTAX INTEGER (0..200) -- UNITS 0.1 percent ACCESS read-only STATUS mandatory DESCRIPTION "The percentage of load is the ratio of each output current to the rated output current to the panel." ::= {pdrPanelEntry 16} -- ==================================================================================== -- -- pdr OBJECT IDENTIFIER ::= {cpqPower 4} -- pdrBreaker OBJECT IDENTIFIER ::= { pdr 3 } -- Based on physical installed Breakers -- pdrBreakerTable OBJECT-TYPE SYNTAX SEQUENCE OF PdrBreakerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of breaker table entries. The number of entries is given by pdrNumBreakers for this panel." ::= { pdrBreaker 1 } pdrBreakerEntry OBJECT-TYPE SYNTAX PdrBreakerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing information applicable to a particular output breaker of a particular panel." INDEX { pdrPanelIndex, pdrBreakerIndex } ::= { pdrBreakerTable 1 } PdrBreakerEntry ::= SEQUENCE { pdrBreakerIndex INTEGER, pdrBreakerPanel INTEGER, pdrBreakerNumPosition INTEGER, pdrBreakerNumPhases INTEGER, pdrBreakerNumSequence INTEGER, pdrBreakerRatedCurrent INTEGER, pdrBreakerMonthlyKWH INTEGER, pdrBreakerYearlyKWH INTEGER, pdrBreakerTotalKWH INTEGER, pdrBreakerCurrent INTEGER, pdrBreakerCurrentPercent INTEGER, pdrBreakerPower INTEGER, pdrBreakerPercentWarning INTEGER, pdrBreakerPercentOverload INTEGER } pdrBreakerIndex OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "The index of breakers. 42 breakers in each panel, arranged in odd and even columns" ::= { pdrBreakerEntry 1 } pdrBreakerPanel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of panel that these breakers are installed on." ::= { pdrBreakerEntry 2 } pdrBreakerNumPosition OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The position of this breaker in the panel, 1-phase breaker or n-m breaker for 2-phase or n-m-k breaker for 3-phase." ::= { pdrBreakerEntry 3 } pdrBreakerNumPhases OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of phase for this particular breaker." ::= { pdrBreakerEntry 4 } pdrBreakerNumSequence OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The sequence of this breaker. i.e. 1 for single phase 1,2 for 2-phase or 1,2,3 for 3-phase." ::= { pdrBreakerEntry 5 } pdrBreakerRatedCurrent OBJECT-TYPE SYNTAX INTEGER -- UNITS 0.1 A ACCESS read-only STATUS mandatory DESCRIPTION "The rated current in Amps for this particular breaker." ::= { pdrBreakerEntry 6 } pdrBreakerMonthlyKWH OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- Units 0.01 KWH ACCESS read-only STATUS mandatory DESCRIPTION "The accumulated KWH for this breaker since the beginning of this calendar month or since the last reset." ::= { pdrBreakerEntry 7 } pdrBreakerYearlyKWH OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- Units 0.01 KWH ACCESS read-only STATUS mandatory DESCRIPTION "The accumulated KWH for this breaker since the beginning of this calendar year or since the last reset." ::= { pdrBreakerEntry 8 } pdrBreakerTotalKWH OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- Units 0.01 KWH ACCESS read-only STATUS mandatory DESCRIPTION "The accumulated KWH for this breaker since it was put into service or since the last reset." ::= { pdrBreakerEntry 9 } pdrBreakerCurrent OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS 0.1 A ACCESS read-only STATUS mandatory DESCRIPTION "The measured output current for this breaker Current." ::= { pdrBreakerEntry 10 } pdrBreakerCurrentPercent OBJECT-TYPE SYNTAX INTEGER (0..200) -- UNITS 0.1 Percent ACCESS read-only STATUS mandatory DESCRIPTION "The ratio of output current over rated current for each breaker." ::= { pdrBreakerEntry 11 } pdrBreakerPower OBJECT-TYPE SYNTAX INTEGER -- UNITS Watts ACCESS read-only STATUS mandatory DESCRIPTION "The power for this breaker in Watts." ::= { pdrBreakerEntry 12 } pdrBreakerPercentWarning OBJECT-TYPE SYNTAX INTEGER (0..200) -- UNITS 0.1 Percent ACCESS read-only STATUS mandatory DESCRIPTION "The percentage of Warning set for this breaker." ::= { pdrBreakerEntry 13 } pdrBreakerPercentOverload OBJECT-TYPE SYNTAX INTEGER -- UNITS 0.1 Percent ACCESS read-only STATUS mandatory DESCRIPTION "The percentage of Overload set for this breaker." ::= { pdrBreakerEntry 14 } -- ==================================================================================== -- -- mpdu OBJECT IDENTIFIER ::= {cpqPower 5} -- mpduIdent OBJECT IDENTIFIER ::= { mpdu 1 } -- MPDU identification group -- mpduNumMPDU OBJECT-TYPE SYNTAX INTEGER (0..63) ACCESS read-only STATUS mandatory DESCRIPTION "The number of Modular PDUs (Core) detected." ::= { mpduIdent 1 } mpduIdentTable OBJECT-TYPE SYNTAX SEQUENCE OF MpduIdentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indexed by mpduNumMPDU. So aggregate objects for each entry equal to mpduNumMPDU before go to the next entry. i.e if 4 MPDU detected, display 4 indexes, 4 Manufacturers, 4 Models..., start with 1." ::= { mpduIdent 2 } mpduIdentEntry OBJECT-TYPE SYNTAX MpduIdentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table entry containing the identifications of each MPDU as well as names of PDR panel, location of MPDU in a Data Center." INDEX { mpduIdentIndex } ::= { mpduIdentTable 1 } MpduIdentEntry ::= SEQUENCE { mpduIdentIndex INTEGER, mpduManufacturer DisplayString, mpduModel DisplayString, mpduName DisplayString, mpduFirmwareVersion DisplayString, mpduHardwareVersion DisplayString, mpduPartNumber DisplayString, mpduSerialNumber DisplayString, mpduUUID DisplayString, mpduIP DisplayString, mpduMACAddress DisplayString, mpduControlStatus DisplayString, mpduRegion DisplayString, mpduType DisplayString, mpduPowerRating DisplayString, mpduInputRating DisplayString, mpduInputPlug DisplayString, mpduNumBreakers INTEGER, mpduNumOutlet INTEGER, mpduUHeight INTEGER, mpduRedundantStatus DisplayString } mpduIdentIndex OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Index for the MpduIdentEntry table. Start with 1" ::= { mpduIdentEntry 1 } mpduManufacturer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Core PDU manufacturer." ::= { mpduIdentEntry 2 } mpduModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Core PDU model, marketing name." ::= { mpduIdentEntry 3 } mpduName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Core PDU name, descriptive name or hostname" ::= { mpduIdentEntry 4 } mpduFirmwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Core PDU firmware version(s)." ::= { mpduIdentEntry 5 } mpduHardwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Core PDU hardware version." ::= { mpduIdentEntry 6 } mpduPartNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Core PDU part number." ::= { mpduIdentEntry 7 } mpduSerialNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The PDU external serial number." ::= { mpduIdentEntry 8 } mpduUUID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The PDU's UUID equals PN add SN." ::= { mpduIdentEntry 9 } mpduIP OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The PDU's assigned IP." ::= { mpduIdentEntry 10 } mpduMACAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Core PDU MAC address." ::= { mpduIdentEntry 11 } mpduControlStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Core PDU Control Status: master or slave units." ::= { mpduIdentEntry 12 } mpduRegion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The PDU's Region: NA, Intl, Japan..." ::= { mpduIdentEntry 13 } mpduType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The PDU's Type: Delta, Wye, single, Wye+lowline." ::= { mpduIdentEntry 14 } mpduPowerRating OBJECT-TYPE SYNTAX DisplayString --UNITS 0.01 KVA ACCESS read-only STATUS mandatory DESCRIPTION "The PDU's Power Rating in KVA (Name Plate). Value is presented in 1/100 of the KVA. i.e. read 1750 means 17.50 KVA" ::= { mpduIdentEntry 15 } mpduInputRating OBJECT-TYPE SYNTAX DisplayString --UNITS A ACCESS read-only STATUS mandatory DESCRIPTION "The PDU's Input Current Rating in A (Name Plate)" ::= { mpduIdentEntry 16 } mpduInputPlug OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The PDU's Input Plug: IEC60309 516P6,NEMA L15-30P..." ::= { mpduIdentEntry 17 } mpduNumBreakers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of breakers used in each MPDU (6 by default)." ::= { mpduIdentEntry 18 } mpduNumOutlet OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of outlets of each MPDU (6 by default)." ::= { mpduIdentEntry 19 } mpduUHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The MPDU U Height (1U by default)." ::= { mpduIdentEntry 20 } mpduRedundantStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Status of Core PDU in paired or not: Stand-alone or Redundant." ::= { mpduIdentEntry 21 } -- ==================================================================================== -- -- mpdu OBJECT IDENTIFIER ::= {cpqPower 5} -- mpduOutput OBJECT IDENTIFIER ::= { mpdu 2 } -- MPDU Output Measurements (6 Load Segments by default) -- mpduOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF MpduOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indexed by mpduNumOutlet. So aggregate objects for each entry equal to (mpduNumMPDU multiplies mpduNumOutlet) before go to the next entry. i.e if 4 MPDU detected, display 6x4 indexes, 6x4 OutputStatus, 6x4 OutputBreakerRating...start with 1." ::= { mpduOutput 1 } mpduOutputEntry OBJECT-TYPE SYNTAX MpduOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The output table entry containing the voltage, current, PF, percent load, VA, Watts for the Modular PDU." INDEX { mpduIdentIndex, mpduOutputIndex } ::= { mpduOutputTable 1 } MpduOutputEntry ::= SEQUENCE { mpduOutputIndex INTEGER, mpduOutputStatus DisplayString, mpduOutputBreakerRating INTEGER, mpduOutputSmartDevice DisplayString, mpduOutputPercentLoad INTEGER, mpduOutputVoltage INTEGER, mpduOutputCurrent INTEGER, mpduOutputPowerVA INTEGER, mpduOutputPowerWatt INTEGER, mpduOutputPowerFactor INTEGER, mpduOutputWarningThreshold INTEGER, mpduOutputCriticalThreshold INTEGER } mpduOutputIndex OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Index for the MpduOutputEntry table." ::= { mpduOutputEntry 1 } mpduOutputStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The overall status of the device: off, on, problem." ::= { mpduOutputEntry 2 } mpduOutputBreakerRating OBJECT-TYPE SYNTAX INTEGER --UNITS A ACCESS read-only STATUS mandatory DESCRIPTION "The rating of each MPDU Output in Ampere." ::= { mpduOutputEntry 3 } mpduOutputSmartDevice OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A smart cord device detected: False, True." ::= { mpduOutputEntry 4 } mpduOutputPercentLoad OBJECT-TYPE SYNTAX INTEGER (0..200) --UNITS 0.1 Percents ACCESS read-only STATUS mandatory DESCRIPTION "The MPDU's each output load in percent of rated capacity. Value is presented in 1/10 of the percentage i.e. 125 is 12.5%. A value of -1 will be returned if the current is unable to be measured." ::= { mpduOutputEntry 5 } mpduOutputVoltage OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS 0.1 Volts ACCESS read-only STATUS mandatory DESCRIPTION "The measured output voltage from the PDU meters in volts. Value is presented in 1/10 of the Volt i.e. 2095 is 209.5 V. A value of -1 will be returned if the voltage is unable to be measured." ::= { mpduOutputEntry 6 } mpduOutputCurrent OBJECT-TYPE SYNTAX INTEGER (0..2147483647) -- UNITS RMS 0.01 Amp ACCESS read-only STATUS mandatory DESCRIPTION "The measured output current from the PDU meters in amps. Value is presented in 1/100 of the Ampere i.e. 175 is 1.75 A. A value of -1 will be returned if the current is unable to be measured." ::= { mpduOutputEntry 7 } mpduOutputPowerVA OBJECT-TYPE SYNTAX INTEGER -- Units VA ACCESS read-only STATUS mandatory DESCRIPTION "The total VA load (VI) measured on the PDU in VA. A value of -1 will be returned if the power is unable to be calculated." ::= { mpduOutputEntry 8 } mpduOutputPowerWatt OBJECT-TYPE SYNTAX INTEGER -- Units Watts ACCESS read-only STATUS mandatory DESCRIPTION "The total power load measured on the PDU in Watts. A value of -1 will be returned if the power is unable to be calculated." ::= { mpduOutputEntry 9 } mpduOutputPowerFactor OBJECT-TYPE SYNTAX INTEGER (0..100) -- 0.01 UNITS ACCESS read-only STATUS mandatory DESCRIPTION "The power factor is presented in 1/100 of the unit i.e. 98 is 0.98. A value of -1 will be returned if the power factor is unable to be measured." ::= { mpduOutputEntry 10 } mpduOutputWarningThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) -- Percents ACCESS read-only STATUS mandatory DESCRIPTION "Report the User-set threshhold limit for Warning in percentage" ::= { mpduOutputEntry 11 } mpduOutputCriticalThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) -- Percents ACCESS read-only STATUS mandatory DESCRIPTION "Report the User-set threshhold limit for Critical in percentage" ::= { mpduOutputEntry 12 } -- ==================================================================================== -- -- mpdu OBJECT IDENTIFIER ::= {cpqPower 5} -- mpduDeviceIdent OBJECT IDENTIFIER ::= { mpdu 3 } -- Identification of all Devices connected to MPDU's outlets -- Smart Devices are those blades/servers/storage encl with smart cord -- mpduDeviceIdentTable OBJECT-TYPE SYNTAX SEQUENCE OF MpduDeviceIdentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indexed by mpduNumOutlet. So aggregate objects for each entry equal to (mpduNumMPDU multiplies mpduNumOutlet) before go to the next entry. i.e if 4 MPDU detected, display 6x4 indexes, 6x4 mpduDeviceStatus, 6x4 DeviceUIDStatus...start with 1." ::= { mpduDeviceIdent 1 } mpduDeviceIdentEntry OBJECT-TYPE SYNTAX MpduDeviceIdentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The ident table entry containing the name, model, manufacturer, firmware version, part number... for each smart device, null value for unknown device." INDEX { mpduIdentIndex, mpduDeviceIdentIndex } ::= { mpduDeviceIdentTable 1 } MpduDeviceIdentEntry ::= SEQUENCE { mpduDeviceIdentIndex INTEGER, mpduDeviceStatus DisplayString, mpduDeviceUIDStatus DisplayString, mpduDeviceNumOutlet INTEGER, mpduDeviceUHeight INTEGER, mpduDevicePowerRating DisplayString, mpduDeviceManufacturer DisplayString, mpduDeviceType DisplayString, mpduDeviceModel DisplayString, mpduDeviceName DisplayString, mpduDeviceFirmwareVersion DisplayString, mpduDeviceHardwareVersion DisplayString, mpduDevicePartNumber DisplayString, mpduDeviceSerialNumber DisplayString, mpduDeviceUUID DisplayString } mpduDeviceIdentIndex OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Index is based on the total number of Smart Extension Bars plus smart devices (with smart cord i.e. blades) detected." ::= { mpduDeviceIdentEntry 1 } mpduDeviceStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The overall status of the device: off, on, problem." ::= { mpduDeviceIdentEntry 2 } mpduDeviceUIDStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The overall status of the device UID: off, on, blink." ::= { mpduDeviceIdentEntry 3 } mpduDeviceNumOutlet OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of outlets of detected the device. This variable indicates the number of rows in the breakers table. Default is 5" ::= { mpduDeviceIdentEntry 4 } mpduDeviceUHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The U height of ext bar or device." ::= { mpduDeviceIdentEntry 5 } mpduDevicePowerRating OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The device's Power Rating in VA. Enter null if not detected." ::= { mpduDeviceIdentEntry 6 } mpduDeviceManufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The Device Manufacturer Name (e.g. Hewlett-Packard). Enter null if not detected." ::= { mpduDeviceIdentEntry 7 } mpduDeviceType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The Device's Type: Ext Bar, server, or network device..." ::= { mpduDeviceIdentEntry 8 } mpduDeviceModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The Device Model is Managed or Non-managed Ext Bar. Enter null if not detected." ::= { mpduDeviceIdentEntry 9 } mpduDeviceName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The string identify the Device. i.e. 'BAR#1' (descriptive name) Enter null if not detected." ::= { mpduDeviceIdentEntry 10 } mpduDeviceFirmwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The firmware revision level of Sm Ext Bar. Enter null if not detected." ::= { mpduDeviceIdentEntry 11 } mpduDeviceHardwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The hardware version of Sm Ext Bar. Enter null if not detected." ::= { mpduDeviceIdentEntry 12 } mpduDevicePartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The device's part number. Enter null if not detected." ::= { mpduDeviceIdentEntry 13 } mpduDeviceSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The device's serial number. Enter null if not detected" ::= { mpduDeviceIdentEntry 14 } mpduDeviceUUID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The device's UUID. Enter null if not detected" ::= { mpduDeviceIdentEntry 15 } -- ==================================================================================== -- -- mpdu OBJECT IDENTIFIER ::= {cpqPower 5} -- mpduSmExtBarOutlet OBJECT IDENTIFIER ::= { mpdu 4 } -- Outputs measurements for each Smart Extension Bar's Outlet and -- Identification of Smart Device connected to Smart Extension Bar. -- mpduSmExtBarOutletTable OBJECT-TYPE SYNTAX SEQUENCE OF MpduSmExtBarOutletEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indexed by mpduDeviceNumOutlet. So aggregate objects for each entry equal to (mpduNumMPDU multiplies mpduNumOutlet multiplies mpduDeviceNumOutlet) before go to the next entry. i.e if 4 MPDU detected, display 5x6x4 indexes, 5x6x4 mpduSmExtBarOutletStatus, 5x6x4 mpduSmExtBarOutletUIDStatus...start with 1." ::= { mpduSmExtBarOutlet 1 } mpduSmExtBarOutletEntry OBJECT-TYPE SYNTAX MpduSmExtBarOutletEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries contain status, measurements for each outlet (no PowerVA) Display null if it can't be measured or no device detected." INDEX { mpduIdentIndex, mpduOutputIndex, mpduSmExtBarOutletIndex } ::= { mpduSmExtBarOutletTable 1 } MpduSmExtBarOutletEntry ::= SEQUENCE { mpduSmExtBarOutletIndex INTEGER, mpduSmExtBarOutletStatus DisplayString, mpduSmExtBarOutletUIDStatus DisplayString, mpduSmExtBarOutletRating INTEGER, mpduSmExtBarOutletVoltage INTEGER, mpduSmExtBarOutletCurrent INTEGER, mpduSmExtBarOutletPowerWatt INTEGER, mpduSmExtBarOutletPowerFactor INTEGER, mpduSmExtBarOutletDeviceName DisplayString, mpduSmExtBarOutletDeviceUUID DisplayString, mpduSmExtBarOutletDeviceProduct DisplayString, mpduSmExtBarOutletDeviceIP DisplayString, mpduSmExtBarOutletAutoDiscovered INTEGER } mpduSmExtBarOutletIndex OBJECT-TYPE SYNTAX INTEGER (0..300) ACCESS read-only STATUS mandatory DESCRIPTION "The Index of Smart Extension Bar." ::= { mpduSmExtBarOutletEntry 1 } mpduSmExtBarOutletStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The overall status of the Smart Extension Bar's outlet: off, on, problem..." ::= { mpduSmExtBarOutletEntry 2 } mpduSmExtBarOutletUIDStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The overall status of the Smart Extension Bar's UID: off, on, blink..." ::= { mpduSmExtBarOutletEntry 3 } mpduSmExtBarOutletRating OBJECT-TYPE SYNTAX INTEGER -- UNITS A ACCESS read-only STATUS mandatory DESCRIPTION "Sm Ext Bar Outlet's Rating in Amp. A value of -1 will be returned if the stick is unable to detect." ::= { mpduSmExtBarOutletEntry 4 } mpduSmExtBarOutletVoltage OBJECT-TYPE SYNTAX INTEGER -- UNITS 0.1 Volts ACCESS read-only STATUS mandatory DESCRIPTION "The SM Ext Bar voltage in volts. Value is presented 1/10 of the Volt i.e. 2098 is 209.8 V. A value of -1 will be returned if the voltage is unable to be measured." ::= { mpduSmExtBarOutletEntry 5 } mpduSmExtBarOutletCurrent OBJECT-TYPE SYNTAX INTEGER -- UNITS 0.01 Amps ACCESS read-only STATUS mandatory DESCRIPTION "The SM Ext Bar current draw in Amps. Value is presented in 1/100 of the Ampere i.e. 127 is 1.27 A. A value of -1 will be returned if the current is unable to be measured." ::= { mpduSmExtBarOutletEntry 6 } mpduSmExtBarOutletPowerWatt OBJECT-TYPE SYNTAX INTEGER -- UNITS Watts ACCESS read-only STATUS mandatory DESCRIPTION "The Sm Ext Bar's Power measured in Watts. A value of -1 will be returned if the power is unable to be measured." ::= { mpduSmExtBarOutletEntry 7 } mpduSmExtBarOutletPowerFactor OBJECT-TYPE SYNTAX INTEGER (0..100) -- 0.01 UNITS ACCESS read-only STATUS mandatory DESCRIPTION "The outlet's power factor in 0.01 unit. It is presented in 1/100 of the unit. i.e. 98 is 0.98. A value of -1 will be returned if the power factor is unable to be measured." ::= { mpduSmExtBarOutletEntry 8 } mpduSmExtBarOutletDeviceName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The Device (Blade/Server/Storage) Name that connects to this Sm Ext Bar. Enter null if not detected" ::= { mpduSmExtBarOutletEntry 9 } mpduSmExtBarOutletDeviceUUID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The Device (Blade/Server/Storage) UUID that connects to this Sm Ext Bar. Enter null if not detected" ::= { mpduSmExtBarOutletEntry 10 } mpduSmExtBarOutletDeviceProduct OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The Device (Blade/Server/Storage) Model that connects to this Sm Ext Bar. Enter null if not detected" ::= { mpduSmExtBarOutletEntry 11 } mpduSmExtBarOutletDeviceIP OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) ACCESS read-only STATUS mandatory DESCRIPTION "The Device (Blade/Server/Storage) IP of iLO that connects to this Sm Ext Bar. Enter null if not detected" ::= { mpduSmExtBarOutletEntry 12 } mpduSmExtBarOutletAutoDiscovered OBJECT-TYPE SYNTAX INTEGER (0..1) --1=able to detect a Blade with smart PS ACCESS read-only STATUS mandatory DESCRIPTION "Boolean values of 0 or 1. 1 means this Sm Ext Bar Outlet is able to get information from a blade with smart power supply (auto discovery is enabled)..." ::= { mpduSmExtBarOutletEntry 13 } END